Rashid Bashir
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rashid Bashir has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Demir Akin
Bio-Acoustic MEMS in Medicine (BAMM) Lab, Canary Center at Stanford University, Department of Radiology, School of Medicine, Stanford University,{Citation} California, CA, 94304, United States
7 shared publications Liju Yang
Birck Nanotechnology Center, School of Electrical Engineering and Computer Engineering, Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN 47907, USA
4 shared publicationsKwan Seop Lim
Birck Nanotechnology Center and Bindley Bioscience Center, Purdue University, West Lafayette, IN, USA
2 shared publicationsWoo-Jin Chang
ERC for Advanced Bioseparation Technology, Inha University, Incheon, Korea
2 shared publicationsYi-Shao Liu
Birck Nanotechnology Center, School of Electrical Engineering and Computer Engineering, Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN 47907, USA
2 shared publicationsA. Aronson
Department of Biological Sciences, Purdue University, West Lafayette, Indiana, USA
1 shared publication
Latest Publications
- 3 July 2007
- Published by Springer Nature in Biomedical Microdevices
- Vol. 9 (6) , 877-883
Electrical capture and lysis of vaccinia virus particles using silicon nano-scale probe array
A probe array with nano-scale tips, integrated into a micro-fluidic channel was developed for the capture and lysing of small number of vaccinia virus particles using dielectrophoresis. The nano-scale probe array was fabricated in Silicon on Insulator (SOI) wafers, and sharpened with repeated oxidation steps. The gap between each probe ranged from 100 nm to 1.5 μm depending on fabrication parameters. The probe array was used to capture vaccinia virus using positive dielectrophoresis (DEP) from a flow within the microfluidic channel, and then the same probe array was used to apply high electric field to lyse the virus particles. It was shown that under electric field strengths of about 107 V/m, the permeability of ethidium bromide into the vaccinia virus particles was increased. Upon SEM analysis, the particles were found to be damaged and exhibited tubules networks, indicating disintegration of the virus outer layer. In addition, elongated strands of DNA were clearly observed on the chip surface after the application of the high electric field, demonstrating the possibility of electrical lysis of virus particles.
- 3 July 2007
- Published by Springer Nature in Biomedical Microdevices
- Vol. 9 (6) , 877-883
Electrical capture and lysis of vaccinia virus particles using silicon nano-scale probe array
A probe array with nano-scale tips, integrated into a micro-fluidic channel was developed for the capture and lysing of small number of vaccinia virus particles using dielectrophoresis. The nano-scale probe array was fabricated in Silicon on Insulator (SOI) wafers, and sharpened with repeated oxidation steps. The gap between each probe ranged from 100 nm to 1.5 μm depending on fabrication parameters. The probe array was used to capture vaccinia virus using positive dielectrophoresis (DEP) from a flow within the microfluidic channel, and then the same probe array was used to apply high electric field to lyse the virus particles. It was shown that under electric field strengths of about 107 V/m, the permeability of ethidium bromide into the vaccinia virus particles was increased. Upon SEM analysis, the particles were found to be damaged and exhibited tubules networks, indicating disintegration of the virus outer layer. In addition, elongated strands of DNA were clearly observed on the chip surface after the application of the high electric field, demonstrating the possibility of electrical lysis of virus particles.
- 25 May 2007
- Published by Springer Nature in Biomedical Microdevices
- Vol. 9 (6) , 787-794
Ultrananocrystalline diamond film as an optimal cell interface for biomedical applications
Surfaces of materials that promote cell adhesion, proliferation, and growth are critical for new generation of implantable biomedical devices. These films should be able to coat complex geometrical shapes very conformally, with smooth surfaces to produce hermetic bioinert protective coatings, or to provide surfaces for cell grafting through appropriate functionalization. Upon performing a survey of desirable properties such as chemical inertness, low friction coefficient, high wear resistance, and a high Young’s modulus, diamond films emerge as very attractive candidates for coatings for biomedical devices. A promising novel material is ultrananocrystalline diamond (UNCD®) in thin film form, since UNCD possesses the desirable properties of diamond and can be deposited as a very smooth, conformal coating using chemical vapor deposition. In this paper, we compared cell adhesion, proliferation, and growth on UNCD films, silicon, and platinum films substrates using different cell lines. Our results showed that UNCD films exhibited superior characteristics including cell number, total cell area, and cell spreading. The results could be attributed to the nanostructured nature or a combination of nanostructure/surface chemistry of UNCD, which provides a high surface energy, hence promoting adhesion between the receptors on the cell surface and the UNCD films.
- 25 May 2007
- Published by Springer Nature in Biomedical Microdevices
- Vol. 9 (6) , 787-794
Ultrananocrystalline diamond film as an optimal cell interface for biomedical applications
Surfaces of materials that promote cell adhesion, proliferation, and growth are critical for new generation of implantable biomedical devices. These films should be able to coat complex geometrical shapes very conformally, with smooth surfaces to produce hermetic bioinert protective coatings, or to provide surfaces for cell grafting through appropriate functionalization. Upon performing a survey of desirable properties such as chemical inertness, low friction coefficient, high wear resistance, and a high Young’s modulus, diamond films emerge as very attractive candidates for coatings for biomedical devices. A promising novel material is ultrananocrystalline diamond (UNCD®) in thin film form, since UNCD possesses the desirable properties of diamond and can be deposited as a very smooth, conformal coating using chemical vapor deposition. In this paper, we compared cell adhesion, proliferation, and growth on UNCD films, silicon, and platinum films substrates using different cell lines. Our results showed that UNCD films exhibited superior characteristics including cell number, total cell area, and cell spreading. The results could be attributed to the nanostructured nature or a combination of nanostructure/surface chemistry of UNCD, which provides a high surface energy, hence promoting adhesion between the receptors on the cell surface and the UNCD films.
- 11 May 2007
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 7 (6) , 746-755
Cell detection and counting through cell lysate impedance spectroscopy in microfluidic devices
Cell-based microfluidic devices have attracted interest for a wide range of applications. While optical cell counting and flow cytometry-type devices have been reported extensively, sensitive and efficient non-optical methods to detect and quantify cells attached over large surface areas within microdevices are generally lacking. We describe an electrical method for counting cells based on the measurement of changes in conductivity of the surrounding medium due to ions released from surface-immobilized cells within a microfluidic channel. Immobilized cells are lysed using a low conductivity, hypotonic media and the resulting change in impedance is measured using surface patterned electrodes to detect and quantify the number of cells. We found that the bulk solution conductance increases linearly with the number of isolated cells contributing to solution ion concentration. The method of cell lysate impedance spectroscopy is sensitive enough to detect 20 cells µL–1, and offers a simple and efficient method for detecting and enumerating cells within microfluidic devices for many applications including measurement of CD4 cell counts in HIV patients in resource-limited settings. To our knowledge, this is the most sensitive approach using non-optical setups to enumerate immobilized cells. The microfluidic device, capable of isolating specific cell types from a complex bio-fluidic and quantifying cell number, can serve as a single use cartridge for a hand-held instrument to provide simple, fast and affordable cell counting in point-of-care settings.
- 11 May 2007
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 7 (6) , 746-755
Cell detection and counting through cell lysate impedance spectroscopy in microfluidic devices
Cell-based microfluidic devices have attracted interest for a wide range of applications. While optical cell counting and flow cytometry-type devices have been reported extensively, sensitive and efficient non-optical methods to detect and quantify cells attached over large surface areas within microdevices are generally lacking. We describe an electrical method for counting cells based on the measurement of changes in conductivity of the surrounding medium due to ions released from surface-immobilized cells within a microfluidic channel. Immobilized cells are lysed using a low conductivity, hypotonic media and the resulting change in impedance is measured using surface patterned electrodes to detect and quantify the number of cells. We found that the bulk solution conductance increases linearly with the number of isolated cells contributing to solution ion concentration. The method of cell lysate impedance spectroscopy is sensitive enough to detect 20 cells µL–1, and offers a simple and efficient method for detecting and enumerating cells within microfluidic devices for many applications including measurement of CD4 cell counts in HIV patients in resource-limited settings. To our knowledge, this is the most sensitive approach using non-optical setups to enumerate immobilized cells. The microfluidic device, capable of isolating specific cell types from a complex bio-fluidic and quantifying cell number, can serve as a single use cartridge for a hand-held instrument to provide simple, fast and affordable cell counting in point-of-care settings.
- 5 April 2007
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 7 (5) , 603-610
Electrical detection of germination of viable model Bacillus anthracis spores in microfluidic biochips
In this paper, we present a new impedance-based method to detect viable spores by electrically detecting their germination in real time within microfluidic biochips. We used Bacillus anthracis Sterne spores as the model organism. During germination, the spores release polar and ionic chemicals, such as dipicolinic acid (DPA), calcium ions, phosphate ions, and amino acids, which correspondingly increase the electrical conductivity of the medium in which the spores are suspended. We first present macro-scale measurements demonstrating that the germination of spores can be electrically detected at a concentration of 109 spores ml−1 in sample volumes of 5 ml, by monitoring changes in the solution conductivity. Germination was induced by introducing an optimized germinant solution consisting of 10 mM L-alanine and 2 mM inosine. We then translated these results to a micro-fluidic biochip, which was a three-layer device: one layer of polydimethylsiloxane (PDMS) with valves, a second layer of PDMS with micro-fluidic channels and chambers, and the third layer with metal electrodes deposited on a pyrex substrate. Dielectrophoresis (DEP) was used to trap and concentrate the spores at the electrodes with greater than 90% efficiency, at a solution flow rate of 0.2 μl min−1 with concentration factors between 107–109 spores ml−1, from sample volumes of 1–5 μl. The spores were captured by DEP in deionized water within 1 min (total volume used ranged from 0.02 μl to 0.2 μl), and then germinant solution was introduced to the flow stream. The detection sensitivity was demonstrated to be as low as about a hundred spores in 0.1 nl, which is equivalent to a macroscale detection limit of approximately 109 spores ml−1. We believe that this is the first demonstration of this application in microfluidic and BioMEMS devices.
- 5 April 2007
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 7 (5) , 603-610
Electrical detection of germination of viable model Bacillus anthracis spores in microfluidic biochips
In this paper, we present a new impedance-based method to detect viable spores by electrically detecting their germination in real time within microfluidic biochips. We used Bacillus anthracis Sterne spores as the model organism. During germination, the spores release polar and ionic chemicals, such as dipicolinic acid (DPA), calcium ions, phosphate ions, and amino acids, which correspondingly increase the electrical conductivity of the medium in which the spores are suspended. We first present macro-scale measurements demonstrating that the germination of spores can be electrically detected at a concentration of 109 spores ml−1 in sample volumes of 5 ml, by monitoring changes in the solution conductivity. Germination was induced by introducing an optimized germinant solution consisting of 10 mM L-alanine and 2 mM inosine. We then translated these results to a micro-fluidic biochip, which was a three-layer device: one layer of polydimethylsiloxane (PDMS) with valves, a second layer of PDMS with micro-fluidic channels and chambers, and the third layer with metal electrodes deposited on a pyrex substrate. Dielectrophoresis (DEP) was used to trap and concentrate the spores at the electrodes with greater than 90% efficiency, at a solution flow rate of 0.2 μl min−1 with concentration factors between 107–109 spores ml−1, from sample volumes of 1–5 μl. The spores were captured by DEP in deionized water within 1 min (total volume used ranged from 0.02 μl to 0.2 μl), and then germinant solution was introduced to the flow stream. The detection sensitivity was demonstrated to be as low as about a hundred spores in 0.1 nl, which is equivalent to a macroscale detection limit of approximately 109 spores ml−1. We believe that this is the first demonstration of this application in microfluidic and BioMEMS devices.
- 1 March 2007
- Published by Wiley in Journal of Rapid Methods and Automation in Microbiology
- Vol. 15 (1) , 1-32
BIOMEMS AND NANOTECHNOLOGY‐BASED APPROACHES FOR RAPID DETECTION OF BIOLOGICAL ENTITIES
In recent years, the areas of Bio‐Microelectromechanical Systems (BioMEMS) and nanotechnology have gained a high level of prominence and have become almost inseparable with biological applications including detection, diagnostics, therapeutics and tissue engineering. This article reviews some of the current state‐of‐the‐art interdisciplinary research from these fields, especially focusing on rapid detection of pathogens and microorganisms, a critical area of importance to food safety, clinical diagnostics and related applications.
- 1 March 2007
- Published by Wiley in Journal of Rapid Methods and Automation in Microbiology
- Vol. 15 (1) , 1-32
BIOMEMS AND NANOTECHNOLOGY‐BASED APPROACHES FOR RAPID DETECTION OF BIOLOGICAL ENTITIES
In recent years, the areas of Bio‐Microelectromechanical Systems (BioMEMS) and nanotechnology have gained a high level of prominence and have become almost inseparable with biological applications including detection, diagnostics, therapeutics and tissue engineering. This article reviews some of the current state‐of‐the‐art interdisciplinary research from these fields, especially focusing on rapid detection of pathogens and microorganisms, a critical area of importance to food safety, clinical diagnostics and related applications.
- 5 September 2006
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 103 (36) , 13362-13367
Anomalous resonance in a nanomechanical biosensor
The decrease in resonant frequency (−Δω r ) of a classical cantilever provides a sensitive measure of the mass of entities attached on its surface. This elementary phenomenon has been the basis of a new class of bio-nanomechanical devices as sensing components of integrated microsystems that can perform rapid, sensitive, and selective detection of biological and biochemical entities. Based on classical analysis, there is a widespread perception that smaller sensors are more sensitive (sensitivity ≈ −0.5ω r / m C , where m C is the mass of the cantilever), and this notion has motivated scaling of biosensors to nanoscale dimensions. In this work, we show that the response of a nanomechanical biosensor is far more complex than previously anticipated. Indeed, in contrast to classical microscale sensors, the resonant frequencies of the nanosensor may actually decrease or increase after attachment of protein molecules. We demonstrate theoretically and experimentally that the direction of the frequency change arises from a size-specific modification of diffusion and attachment kinetics of biomolecules on the cantilevers. This work may have broad impact on microscale and nanoscale biosensor design, especially when predicting the characteristics of bio-nanoelectromechanical sensors functionalized with biological capture molecules.
- 5 September 2006
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 103 (36) , 13362-13367
Anomalous resonance in a nanomechanical biosensor
The decrease in resonant frequency (−Δω r ) of a classical cantilever provides a sensitive measure of the mass of entities attached on its surface. This elementary phenomenon has been the basis of a new class of bio-nanomechanical devices as sensing components of integrated microsystems that can perform rapid, sensitive, and selective detection of biological and biochemical entities. Based on classical analysis, there is a widespread perception that smaller sensors are more sensitive (sensitivity ≈ −0.5ω r / m C , where m C is the mass of the cantilever), and this notion has motivated scaling of biosensors to nanoscale dimensions. In this work, we show that the response of a nanomechanical biosensor is far more complex than previously anticipated. Indeed, in contrast to classical microscale sensors, the resonant frequencies of the nanosensor may actually decrease or increase after attachment of protein molecules. We demonstrate theoretically and experimentally that the direction of the frequency change arises from a size-specific modification of diffusion and attachment kinetics of biomolecules on the cantilevers. This work may have broad impact on microscale and nanoscale biosensor design, especially when predicting the characteristics of bio-nanoelectromechanical sensors functionalized with biological capture molecules.
- 23 June 2006
- Published by Springer Nature in Biomedical Microdevices
- Vol. 8 (3) , 263-269
DNA counterion current and saturation examined by a MEMS-based solid state nanopore sensor
Reports of DNA translocation measurements have been increasing rapidly in recent years due to advancements in pore fabrication and these measurements continue to provide insight into the physics of DNA translocations through MEMS based solid state nanopores. Specifically, it has recently been demonstrated that in addition to typically observed current blockages, enhancements in current can also be measured under certain conditions. Here, we further demonstrate the power of these nanopores for examining single DNA molecules by measuring these ionic currents as a function of the applied electric field and show that the direction of the resulting current pulse can provide fundamental insight into the physics of condensed counterions and the dipole saturation in single DNA molecules. Expanding on earlier work by Manning and others, we propose a model of DNA counterion ionic current and saturation of this current based on our experimental results. The work can have broad impact in understanding DNA sensing, DNA delivery into cells, DNA conductivity, and molecular electronics.
- 23 June 2006
- Published by Springer Nature in Biomedical Microdevices
- Vol. 8 (3) , 263-269
DNA counterion current and saturation examined by a MEMS-based solid state nanopore sensor
Reports of DNA translocation measurements have been increasing rapidly in recent years due to advancements in pore fabrication and these measurements continue to provide insight into the physics of DNA translocations through MEMS based solid state nanopores. Specifically, it has recently been demonstrated that in addition to typically observed current blockages, enhancements in current can also be measured under certain conditions. Here, we further demonstrate the power of these nanopores for examining single DNA molecules by measuring these ionic currents as a function of the applied electric field and show that the direction of the resulting current pulse can provide fundamental insight into the physics of condensed counterions and the dipole saturation in single DNA molecules. Expanding on earlier work by Manning and others, we propose a model of DNA counterion ionic current and saturation of this current based on our experimental results. The work can have broad impact in understanding DNA sensing, DNA delivery into cells, DNA conductivity, and molecular electronics.
- 7 June 2006
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 6 (7) , 896-905
A multifunctional micro-fluidic system for dielectrophoretic concentration coupled with immuno-capture of low numbers of Listeria monocytogenes
In this study, we demonstrated a micro-fluidic system with multiple functions, including concentration of bacteria using dielectrophoresis (DEP) and selective capture using antibody recognition, resulting in a high capture efficiency of bacterial cells. The device consisted of an array of oxide covered interdigitated electrodes on a flat silicon substrate and a ∼16 µm high and ∼260 µm wide micro-channel within a PDMS cover. For selective capture of Listeria monocytogenes from the samples, the channel surface was functionalized with a biotinylated BSA–streptavidin–biotinylated monoclonal antibody sandwich structure. Positive DEP (at 20 Vpp and 1 MHz) was used to concentrate bacterial cells from the fluid flow. DEP could collect ∼90% of the cells in a continuous flow at a flow rate of 0.2 µl min−1 into the micro-channel with concentration factors between 102–103, in sample volumes of 5–20 µl. A high flow rate of 0.6 µl min−1 reduced the DEP capture efficiency to ∼65%. Positive DEP attracts cells to the edges of the electrodes where the field gradient is the highest. Cells concentrated by DEP were captured by the antibodies immobilized on the channel surface with efficiencies of 18 to 27% with bacterial cell numbers ranging from 101 to 103 cells. It was found that DEP operation in our experiments did not cause any irreversible damage to bacterial cells in terms of cell viability. In addition, increased antigen expression (antigens to C11E9 monoclonal antibody) on cell membranes was observed following the exposure to DEP.
- 7 June 2006
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 6 (7) , 896-905
A multifunctional micro-fluidic system for dielectrophoretic concentration coupled with immuno-capture of low numbers of Listeria monocytogenes
In this study, we demonstrated a micro-fluidic system with multiple functions, including concentration of bacteria using dielectrophoresis (DEP) and selective capture using antibody recognition, resulting in a high capture efficiency of bacterial cells. The device consisted of an array of oxide covered interdigitated electrodes on a flat silicon substrate and a ∼16 µm high and ∼260 µm wide micro-channel within a PDMS cover. For selective capture of Listeria monocytogenes from the samples, the channel surface was functionalized with a biotinylated BSA–streptavidin–biotinylated monoclonal antibody sandwich structure. Positive DEP (at 20 Vpp and 1 MHz) was used to concentrate bacterial cells from the fluid flow. DEP could collect ∼90% of the cells in a continuous flow at a flow rate of 0.2 µl min−1 into the micro-channel with concentration factors between 102–103, in sample volumes of 5–20 µl. A high flow rate of 0.6 µl min−1 reduced the DEP capture efficiency to ∼65%. Positive DEP attracts cells to the edges of the electrodes where the field gradient is the highest. Cells concentrated by DEP were captured by the antibodies immobilized on the channel surface with efficiencies of 18 to 27% with bacterial cell numbers ranging from 101 to 103 cells. It was found that DEP operation in our experiments did not cause any irreversible damage to bacterial cells in terms of cell viability. In addition, increased antigen expression (antigens to C11E9 monoclonal antibody) on cell membranes was observed following the exposure to DEP.
- 10 March 2006
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 6 (4) , 578-580
Reliable fabrication method of transferable micron scale metal pattern for poly(dimethylsiloxane) metallization
We have developed a reliable fabrication method of forming micron scale metal patterns on poly(dimethylsiloxane) (PDMS) using a pattern transfer process. A metal stack layer consisting of Au–Ti–Au layers, providing a weak but reliable adhesion, was deposited on a silicon wafer. The metal stack layer was then transferred to a PDMS substrate using serial and selective etching. We demonstrate that features as small as 2 µm were reliably transferred on to the PDMS substrate for use as interconnects and electrodes for biosensors and flexible electronics application.
- 10 March 2006
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 6 (4) , 578-580
Reliable fabrication method of transferable micron scale metal pattern for poly(dimethylsiloxane) metallization
We have developed a reliable fabrication method of forming micron scale metal patterns on poly(dimethylsiloxane) (PDMS) using a pattern transfer process. A metal stack layer consisting of Au–Ti–Au layers, providing a weak but reliable adhesion, was deposited on a silicon wafer. The metal stack layer was then transferred to a PDMS substrate using serial and selective etching. We demonstrate that features as small as 2 µm were reliably transferred on to the PDMS substrate for use as interconnects and electrodes for biosensors and flexible electronics application.
- 1 December 2005
- Published by Springer Nature in NanoBiotechnology
- Vol. 1 (4) , 337-345
Delocalization of vaccinia virus components observed by atomic force and fluorescence microscopy
- 1 December 2005
- Published by Springer Nature in NanoBiotechnology
- Vol. 1 (4) , 337-345
Delocalization of vaccinia virus components observed by atomic force and fluorescence microscopy