David A. Elliott
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
David A. Elliott has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Gina Zhang
Department of Cell Biology and Anatomy, University of Arizona College of Medicine, Tucson, AZ 85724; and
1 shared publicationH. Dean Hosgood
Epidemiology and Public Health, and
1 shared publication- Jeffrey J. Rodriguez
Department of Electrical and Computer Engineering, The University of Arizona, Tucson, AZ 85721, USA
1 shared publication - Keith A. Joiner
University of Arizona, USA
1 shared publication Michael T. McIntosh
Departments of ‡Internal Medicine
1 shared publicationPavlina Baevova
Laboratory Medicine, Yale University School of Medicine, New Haven, CT 06520
1 shared publication
Latest Publications
- 1 March 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 117-120
Automated 3-D Segmentation of Internal Hemoglobin in TEM Images
Active contour models or snakes are widely used for medical image segmentation, due to their robustness to images with weak borders and poor contrast, and their ability to provide smooth contours. However, initialization is a serious problem for active contours and they tend to be attracted towards inappropriate image features if the initialization is not proper. In this paper, we propose a method that combines region growing and active contours for segmenting internal hemoglobin in transmission electron micrograph images of malaria parasites. Region growing is used in each image slice to provide the initial contour for the snake, which then determines the final contour based on the gradient vector field. Experimental results demonstrate the effectiveness of the proposed scheme in terms of segmentation quality and accuracy.
- 1 March 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 117-120
Automated 3-D Segmentation of Internal Hemoglobin in TEM Images
Active contour models or snakes are widely used for medical image segmentation, due to their robustness to images with weak borders and poor contrast, and their ability to provide smooth contours. However, initialization is a serious problem for active contours and they tend to be attracted towards inappropriate image features if the initialization is not proper. In this paper, we propose a method that combines region growing and active contours for segmenting internal hemoglobin in transmission electron micrograph images of malaria parasites. Region growing is used in each image slice to provide the initial contour for the snake, which then determines the final contour based on the gradient vector field. Experimental results demonstrate the effectiveness of the proposed scheme in terms of segmentation quality and accuracy.
- 19 February 2008
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 105 (7) , 2463-2468
Four distinct pathways of hemoglobin uptake in the malaria parasite Plasmodium falciparum
During the bloodstage of malaria infection, the parasite internalizes and degrades massive amounts of hemoglobin from the host red blood cell. Using serial thin-section electron microscopy and three-dimensional reconstruction, we demonstrate four independent, but partially overlapping, hemoglobin-uptake processes distinguishable temporally, morphologically, and pharmacologically. Early ring-stage parasites undergo a profound morphological transformation in which they fold, like a cup, onto themselves and in so doing take a large first gulp of host cell cytoplasm. This event, which we term the “Big Gulp,” appears to be independent of actin polymerization and marks the first step in biogenesis of the parasite's lysosomal compartment—the food vacuole. A second, previously identified uptake process, uses the cytostome, a well characterized and morphologically distinct structure at the surface of the parasite. This process is more akin to classical endocytosis, giving rise to small (Plasmodium , thus opening avenues to antimalarial therapy.
- 19 February 2008
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 105 (7) , 2463-2468
Four distinct pathways of hemoglobin uptake in the malaria parasite Plasmodium falciparum
During the bloodstage of malaria infection, the parasite internalizes and degrades massive amounts of hemoglobin from the host red blood cell. Using serial thin-section electron microscopy and three-dimensional reconstruction, we demonstrate four independent, but partially overlapping, hemoglobin-uptake processes distinguishable temporally, morphologically, and pharmacologically. Early ring-stage parasites undergo a profound morphological transformation in which they fold, like a cup, onto themselves and in so doing take a large first gulp of host cell cytoplasm. This event, which we term the “Big Gulp,” appears to be independent of actin polymerization and marks the first step in biogenesis of the parasite's lysosomal compartment—the food vacuole. A second, previously identified uptake process, uses the cytostome, a well characterized and morphologically distinct structure at the surface of the parasite. This process is more akin to classical endocytosis, giving rise to small (Plasmodium , thus opening avenues to antimalarial therapy.
- 1 January 2007
- Published by Oxford University Press (OUP) in Microscopy Today
- Vol. 15 (1) , 30-33
Serial Sectioning via Microtomy (or, How To Get Over 100 Consecutive Serial Sections On One TEM Gird)
Serial sectioning of TEM blocks is a common technique. The more sections that are desired, the more complex the procedure becomes. Some of the problems faced are staining without losing or obscuring sections, appropriate block trimming, finding the area of interest in the next section, transferring sections to the grid. Here, I relate a set of techniques that permit the microtomist to regularly get over 100 consecutive serial sections on a single slot grid. Much of what is discussed below is not new, but by putting all of these techniques together I believe that a powerful tool for TEM is presented. The first issue that must be addressed is how to stain the sections on the grid without losing sections or obscuring sections with staining artifacts (e.g. lead pepper). The simplest solution is to stain the sample with both uranium and lead prior to embedding and not stain the sections on the grid.
- 1 January 2007
- Published by Oxford University Press (OUP) in Microscopy Today
- Vol. 15 (1) , 30-33
Serial Sectioning via Microtomy (or, How To Get Over 100 Consecutive Serial Sections On One TEM Gird)
Serial sectioning of TEM blocks is a common technique. The more sections that are desired, the more complex the procedure becomes. Some of the problems faced are staining without losing or obscuring sections, appropriate block trimming, finding the area of interest in the next section, transferring sections to the grid. Here, I relate a set of techniques that permit the microtomist to regularly get over 100 consecutive serial sections on a single slot grid. Much of what is discussed below is not new, but by putting all of these techniques together I believe that a powerful tool for TEM is presented. The first issue that must be addressed is how to stain the sections on the grid without losing sections or obscuring sections with staining artifacts (e.g. lead pepper). The simplest solution is to stain the sample with both uranium and lead prior to embedding and not stain the sections on the grid.