Hur Koser
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Hur Koser has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Leidong Mao
Faculty of Engineering, Nanoscale Science and Engineering Center, University of Georgia, Athens, GA 30602
2 shared publicationsMuhammet Uncuer
Yale Univ, Sch Engn & Appl Sci, New Haven, CT 06520 USA
2 shared publicationsAyse R. Kose
Department of Electrical Engineering, School of Engineering and Applied Sciences, Yale University, New Haven, CT 06520-8284, USA
1 shared publication- Ayse Rezzan Kose
School of Engineering and Applied Science, Yale University, 15 Prospect St., Becton Center, Room 608, New Haven, CT 06520-8267, USA
1 shared publication B Marinkovic
Yale Univ, Sch Engn & Appl Sci, New Haven, CT 06520 USA
1 shared publicationBirgit Fischer
Hamburger Synchrotronstrahlungslabor, Deutsches Elektronen Synchrotron, Notkestrasse 85, 22607 Hamburg, Germany; and
1 shared publication
Latest Publications
- 9 November 2012
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 22 (12)
Investigation of electroless Au/Cu for microswitches and its contact behavior
- 9 November 2012
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 22 (12)
Investigation of electroless Au/Cu for microswitches and its contact behavior
- 11 May 2012
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 21 (6)
Demonstration of wide bandwidth energy harvesting from vibrations
- 11 May 2012
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 21 (6)
Demonstration of wide bandwidth energy harvesting from vibrations
- 8 December 2011
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 22 (1)
Characterization and application of selective all-wet metallization of silicon
- 8 December 2011
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 22 (1)
Characterization and application of selective all-wet metallization of silicon
- 11 November 2011
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 12 (1) , 190-196
Ferrofluid mediated nanocytometry
We present a low-cost, flow-through nanocytometer that utilizes a colloidal suspension of non-functionalized magnetic nanoparticles for label-free manipulation and separation of microparticles. Our size-based separation is mediated by angular momentum transfer from magnetically excited ferrofluid particles to microparticles. The nanocytometer is capable of rapidly sorting and focusing two or more species, with up to 99% separation efficiency and a throughput of 3 × 104 particles/s per mm2 of channel cross-section. The device is readily scalable and applicable to live cell sorting with biocompatible ferrofluids, offering competitive cytometer performance in a simple and inexpensive package.
- 11 November 2011
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 12 (1) , 190-196
Ferrofluid mediated nanocytometry
We present a low-cost, flow-through nanocytometer that utilizes a colloidal suspension of non-functionalized magnetic nanoparticles for label-free manipulation and separation of microparticles. Our size-based separation is mediated by angular momentum transfer from magnetically excited ferrofluid particles to microparticles. The nanocytometer is capable of rapidly sorting and focusing two or more species, with up to 99% separation efficiency and a throughput of 3 × 104 particles/s per mm2 of channel cross-section. The device is readily scalable and applicable to live cell sorting with biocompatible ferrofluids, offering competitive cytometer performance in a simple and inexpensive package.
- Open Access
- 15 September 2011
- Published by American Physical Society (APS) in Physical Review B
- Vol. 84 (10) , 104431
Direct observation of closed-loop ferrohydrodynamic pumping under traveling magnetic fields
Ferrofluid-based liquid manipulation schemes typically actuate an immiscible liquid via a ferrofluid plug, using high magnetic flux (∼1 T) densities and strong field gradients created with bulky permanent magnets. They rely on surface tension effects to maintain the cohesion of the ferrofluid plug, necessitating miniature channels and slow (∼1 μl/min) flow speeds. Here, we demonstrate direct ferrohydrodynamic pumping using traveling magnetic fields at controllable speeds in a simple, closed-loop geometry without any mechanically actuated components. The pumping approach is compact, scalable, and practical. Using moderate field amplitudes (∼10 mT), we obtained a maximum volumetric flow rate of 0.69 ml/s using a readily available commercial ferrofluid. Our closed-loop pumping approach could lead to integrated and efficient liquid manipulation and cooling schemes based on ferrofluids.
- 15 September 2011
- Published by American Physical Society (APS) in Physical Review B
- Vol. 84 (10) , 104431
Open AccessDirect observation of closed-loop ferrohydrodynamic pumping under traveling magnetic fields
Ferrofluid-based liquid manipulation schemes typically actuate an immiscible liquid via a ferrofluid plug, using high magnetic flux (∼1 T) densities and strong field gradients created with bulky permanent magnets. They rely on surface tension effects to maintain the cohesion of the ferrofluid plug, necessitating miniature channels and slow (∼1 μl/min) flow speeds. Here, we demonstrate direct ferrohydrodynamic pumping using traveling magnetic fields at controllable speeds in a simple, closed-loop geometry without any mechanically actuated components. The pumping approach is compact, scalable, and practical. Using moderate field amplitudes (∼10 mT), we obtained a maximum volumetric flow rate of 0.69 ml/s using a readily available commercial ferrofluid. Our closed-loop pumping approach could lead to integrated and efficient liquid manipulation and cooling schemes based on ferrofluids.
- 1 January 2010
- Published by Springer Nature in Science-Business eXchange
- Vol. 3 (1) , 33
Microfluidics-based cell sorting for diagnostic platforms or sensors
- 1 January 2010
- Published by Springer Nature in Science-Business eXchange
- Vol. 3 (1) , 33
Microfluidics-based cell sorting for diagnostic platforms or sensors
- 22 December 2009
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 106 (51) , 21478-21483
Label-free cellular manipulation and sorting via biocompatible ferrofluids
We present a simple microfluidic platform that uses biocompatible ferrofluids for the controlled manipulation and rapid separation of both microparticles and live cells. This low-cost platform exploits differences in particle size, shape, and elasticity to achieve rapid and efficient separation. Using microspheres, we demonstrate size-based separation with 99% separation efficiency and sub-10-μm resolution in <45 s. We also show continuous manipulation and shape-based separation of live red blood cells from sickle cells and bacteria. These initial demonstrations reveal the potential of ferromicrofluidics in significantly reducing incubation times and increasing diagnostic sensitivity in cellular assays through rapid separation and delivery of target cells to sensor arrays.
- 22 December 2009
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 106 (51) , 21478-21483
Label-free cellular manipulation and sorting via biocompatible ferrofluids
We present a simple microfluidic platform that uses biocompatible ferrofluids for the controlled manipulation and rapid separation of both microparticles and live cells. This low-cost platform exploits differences in particle size, shape, and elasticity to achieve rapid and efficient separation. Using microspheres, we demonstrate size-based separation with 99% separation efficiency and sub-10-μm resolution in <45 s. We also show continuous manipulation and shape-based separation of live red blood cells from sickle cells and bacteria. These initial demonstrations reveal the potential of ferromicrofluidics in significantly reducing incubation times and increasing diagnostic sensitivity in cellular assays through rapid separation and delivery of target cells to sensor arrays.
- 9 March 2009
- Published by AIP Publishing in Applied Physics Letters
- Vol. 94 (10) , 103505
Smart Sand—a wide bandwidth vibration energy harvesting platform
We propose a concept for true wide bandwidth vibration energy harvesting. Our approach exploits nonlinear stretching of fixed-fixed beams in an off-resonance mode, effectively expanding the operational frequency range well beyond the narrow bandwidth of linear resonators. Our initial prototype demonstrates operation between 160–400 Hz, without the need for frequency tuning. A simple dynamic model shows good agreement with measurements. Optimized device geometry will allow for even lower frequency operation (starting at 60 Hz) at strain levels above 1e-3 (ideal for piezoelectric transduction).
- 9 March 2009
- Published by AIP Publishing in Applied Physics Letters
- Vol. 94 (10) , 103505
Smart Sand—a wide bandwidth vibration energy harvesting platform
We propose a concept for true wide bandwidth vibration energy harvesting. Our approach exploits nonlinear stretching of fixed-fixed beams in an off-resonance mode, effectively expanding the operational frequency range well beyond the narrow bandwidth of linear resonators. Our initial prototype demonstrates operation between 160–400 Hz, without the need for frequency tuning. A simple dynamic model shows good agreement with measurements. Optimized device geometry will allow for even lower frequency operation (starting at 60 Hz) at strain levels above 1e-3 (ideal for piezoelectric transduction).
- 1 September 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A New Batteryless Active RFID System: Smart RFID
Since RFID systems start to share the supply chain market with the barcodes, new application areas have become attractive where the wireless radio-frequency communication and identification is possible. Unlike the passive systems, active RFID systems can be used as sensor nodes and they can monitor and store environment data, such as acceleration or temperature. However, the need of external battery limits their applications to where battery replacements are only possible. In this paper, a new batteryless active RFID transponder system has been proposed based on a MEMS (Micro-Electro Mechanical Systems) energy scavenger. The mechanical part of the system has been designed and fabricated. The circuit level simulations have been performed. In this context, a new modulation scheme has been proposed and a magnetic random access memory (MRAM) has been used for the data storage.
- 1 September 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A New Batteryless Active RFID System: Smart RFID
Since RFID systems start to share the supply chain market with the barcodes, new application areas have become attractive where the wireless radio-frequency communication and identification is possible. Unlike the passive systems, active RFID systems can be used as sensor nodes and they can monitor and store environment data, such as acceleration or temperature. However, the need of external battery limits their applications to where battery replacements are only possible. In this paper, a new batteryless active RFID transponder system has been proposed based on a MEMS (Micro-Electro Mechanical Systems) energy scavenger. The mechanical part of the system has been designed and fabricated. The circuit level simulations have been performed. In this context, a new modulation scheme has been proposed and a magnetic random access memory (MRAM) has been used for the data storage.
- 1 January 2007
- Published by Springer Nature in MRS Proceedings
- Vol. 1032
Biomedical Engineered Ferrofluids
The characteristic of combining liquid behavior with and magnetic properties makes ferrofluids unique and it provides them a variety of applications, in particular in the medial field. For medical application ferrofluids are required to be stable at neutral pH and against high salt concentration. Here we present a new approach to stabilize water-based ferrofluids by using genetically engineered peptides for inorganics (GEPI's). Such GEPI's selected for specific and strong binding to the surface of nanoparticles not only increase colloidal stability by acting as a thin surfactant, but they also enable an efficient route for rendering the ferrofluid bio-functional and bio-compatible. The stability of a ferrofluid was characterized by the ac-susceptibility and by using it in a ferro-microfluidic device. This chip actuates the ferrofluid directly via magnetic fields alone, and the pumping spectrum as a function of frequency reveals information about the size of the magnetic nanoparticles. An ideal ferrofluid with monodisperse particles displays a single and clear pumping peak. Agglomeration can directly be observed as a broadening of the pumping spectrum.
- 1 January 2007
- Published by Springer Nature in MRS Proceedings
- Vol. 1032
Biomedical Engineered Ferrofluids
The characteristic of combining liquid behavior with and magnetic properties makes ferrofluids unique and it provides them a variety of applications, in particular in the medial field. For medical application ferrofluids are required to be stable at neutral pH and against high salt concentration. Here we present a new approach to stabilize water-based ferrofluids by using genetically engineered peptides for inorganics (GEPI's). Such GEPI's selected for specific and strong binding to the surface of nanoparticles not only increase colloidal stability by acting as a thin surfactant, but they also enable an efficient route for rendering the ferrofluid bio-functional and bio-compatible. The stability of a ferrofluid was characterized by the ac-susceptibility and by using it in a ferro-microfluidic device. This chip actuates the ferrofluid directly via magnetic fields alone, and the pumping spectrum as a function of frequency reveals information about the size of the magnetic nanoparticles. An ideal ferrofluid with monodisperse particles displays a single and clear pumping peak. Agglomeration can directly be observed as a broadening of the pumping spectrum.