ATArne Tapfer

Arne Tapfer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Arne Tapfer has a total of 38 co-authors. Here are the top co-authors by number of shared publications:

  • Franz Pfeiffer

    Department of Physics and Institute of Medical Engineering, Technische Universität München, Garching, Germany

    2 shared publications
  • Martin Bech

    Department of Physics and Institute of Medical Engineering, Technische Universität München, Garching, Germany

    2 shared publications
  • A Sasov

    Microworks, Karlsruhe, DE

    1 shared publication
  • Alexander Sasov

    Bruker microCT, Kartuizersweg 3B, 2550 Kontich, Belgium

    1 shared publication
  • Astrid Velroyen

    Department of Physics and Institute of Medical Engineering, Technische Universität München, James-Franck-Straße, 85748 Garching, Germany

    1 shared publication
  • Axel Walch

    Research Unit Analytical Pathology, Institute of Pathology, Helmholtz Zentrum München, Oberschleißheim, Germany

    1 shared publication

Latest Publications

  • Three-dimensional imaging of whole mouse models: comparing nondestructive X-ray phase-contrast micro-CT with cryotome-based planar epi-illumination imaging

    by A. Tapfer, M. Bech, I. Zanette, P. Symvoulidis, S. Stangl, G. Multhoff, M. Molls, V. Ntziachristos, F. Pfeiffer

    In this study, we compare two evolving techniques for obtaining high-resolution 3D anatomical data of a mouse specimen. On the one hand, we investigate cryotome-based planar epi-illumination imaging (cryo-imaging). On the other hand, we examine X-ray phase-contrast micro-computed tomography (micro-CT) using synchrotron radiation. Cryo-imaging is a technique in which an electron multiplying charge coupled camera takes images of a cryo-frozen specimen during the sectioning process. Subsequent image alignment and virtual stacking result in volumetric data. X-ray phase-contrast imaging is based on the minute refraction of X-rays inside the specimen and features higher soft-tissue contrast than conventional, attenuation-based micro-CT. To explore the potential of both techniques for studying whole mouse disease models, one mouse specimen was imaged using both techniques. Obtained data are compared visually and quantitatively, specifically with regard to the visibility of fine anatomical details. Internal structure of the mouse specimen is visible in great detail with both techniques and the study shows in particular that soft-tissue contrast is strongly enhanced in the X-ray phase images compared to the attenuation-based images. This identifies phase-contrast micro-CT as a powerful tool for the study of small animal disease models.


  • Open Access

    X-Ray Phase-Contrast CT of a Pancreatic Ductal Adenocarcinoma Mouse Model

    by Arne Tapfer, Rickmer Braren, Martin Bech, Marian Willner, Irene Zanette, Timm Weitkamp, Marija Trajkovic-Arsic, Jens T. Siveke, Marcus Settles, Michaela Aichler, et al.

    To explore the potential of grating-based x-ray phase-contrast computed tomography (CT) for preclinical research, a genetically engineered mouse model of pancreatic ductal adenocarcinoma (PDAC) was investigated. One ex-vivo mouse specimen was scanned with different grating-based phase-contrast CT imaging setups covering two different settings: i) high-resolution synchrotron radiation (SR) imaging and ii) dose-reduced imaging using either synchrotron radiation or a conventional x-ray tube source. These experimental settings were chosen to assess the potential of phase-contrast imaging for two different types of application: i) high-performance imaging for virtual microscopy applications and ii) biomedical imaging with increased soft-tissue contrast for in-vivo applications. For validation and as a reference, histological slicing and magnetic resonance imaging (MRI) were performed on the same mouse specimen. For each x-ray imaging setup, attenuation and phase-contrast images were compared visually with regard to contrast in general, and specifically concerning the recognizability of lesions and cancerous tissue. To quantitatively assess contrast, the contrast-to-noise ratios (CNR) of selected regions of interest (ROI) in the attenuation images and the phase images were analyzed and compared. It was found that both for virtual microscopy and for in-vivo applications, there is great potential for phase-contrast imaging: in the SR-based benchmarking data, fine details about tissue composition are accessible in the phase images and the visibility of solid tumor tissue under dose-reduced conditions is markedly superior in the phase images. The present study hence demonstrates improved diagnostic value with phase-contrast CT in a mouse model of a complex endogenous cancer, promoting the use and further development of grating-based phase-contrast CT for biomedical imaging applications.


  • Experimental results from a preclinical X-ray phase-contrast CT scanner

    by Arne Tapfer, Martin Bech, Astrid Velroyen, Jan Meiser, Jürgen Mohr, Marco Walter, Joachim Schulz, Bart Pauwels, Peter Bruyndonckx, Xuan Liu, et al.

    To explore the future clinical potential of improved soft-tissue visibility with grating-based X-ray phase contrast (PC), we have developed a first preclinical computed tomography (CT) scanner featuring a rotating gantry. The main challenge in the transition from previous bench-top systems to a preclinical scanner are phase artifacts that are caused by minimal changes in the grating alignment during gantry rotation. In this paper, we present the first experimental results from the system together with an adaptive phase recovery method that corrects for these phase artifacts. Using this method, we show that the scanner can recover quantitatively accurate Hounsfield units in attenuation and phase. Moreover, we present a first tomography scan of biological tissue with complementary information in attenuation and phase contrast. The present study hence demonstrates the feasibility of grating-based phase contrast with a rotating gantry for the first time and paves the way for future in vivo studies on small animal disease models (in the mid-term future) and human diagnostics applications (in the long-term future).


  • SU-C-211-01: First Results from a Preclinical X-Ray Phase-Contrast CT Scanner

    by A Tapfer, M Bech, B Pauwels, X Liu, P Bruyndonckx, A Sasov, J Kenntner, J Mohr, M Walter, J Schulz, et al.