MTMartin P. Tornai

Martin P. Tornai

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Martin P. Tornai has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Development of Fully-3D CT in a Hybrid SPECT-CT Breast Imaging System

    by Martin P. Tornai, Jainil P. Shah, Steve D. Mann, Randolph L. McKinley


  • Towards Quantification of Functional Breast Images Using Dedicated SPECT With Non-Traditional Acquisition Trajectories

    by Kristy L. Perez, Spencer J. Cutler, Priti Madhav, Martin P. Tornai

    Quantification of radiotracer uptake in breast lesions can provide valuable information to physicians in deciding patient care or determining treatment efficacy. Physical processes (e.g., scatter, attenuation), detector/collimator characteristics, sampling and acquisition trajectories, and reconstruction artifacts contribute to an incorrect measurement of absolute tracer activity and distribution. For these experiments, a cylinder with three syringes of varying radioactivity concentration, and a fillable 800 mL breast with two lesion phantoms containing aqueous 99m Tc pertechnetate were imaged using the SPECT sub-system of the dual-modality SPECT-CT dedicated breast scanner. SPECT images were collected using a compact CZT camera with various 3D acquisitions including vertical axis of rotation, 30° tilted, and complex sinusoidal trajectories. Different energy windows around the photopeak were quantitatively compared, along with appropriate scatter energy windows, to determine the best quantification accuracy after attenuation and dual-window scatter correction. Measured activity concentrations in the reconstructed images for syringes with greater than 10 μCi/mL corresponded to within 10% of the actual dose calibrator measured activity concentration for ±4% and ±8% photopeak energy windows. The same energy windows yielded lesion quantification results within 10% in the breast phantom as well. Results for the more complete complex sinsusoidal trajectory are similar to the simple vertical axis acquisition, and additionally allows both anterior chest wall sampling, no image distortion, and reasonably accurate quantification.


  • Performance of dedicated emission mammotomography for various breast shapes and sizes

    by C N Brzymialkiewicz, M P Tornai, R L McKinley, S J Cutler, J E Bowsher

    We evaluate the effect of breast shape and size and lesion location on a dedicated emission mammotomography system developed in our lab. The hemispherical positioning gantry allows ample flexibility in sampling a pendant, uncompressed breast. Realistic anthropomorphic torso (which includes the upper portion of the arm) and breast phantoms draw attention to the necessity of using unique camera trajectories (orbits) rather than simple circular camera trajectories. We have implemented several novel three-dimensional (3D) orbits with fully contoured radius-of-rotation capability for compensating for the positioning demands that emerge from different breast shapes and sizes. While a general orbit design may remain the same between two different breasts, the absolute polar tilt range and radius-of-rotation range may vary. We have demonstrated that using 3D orbits with increased polar camera tilt, lesions near the chest wall can be visualized for both large and small sized breasts (325 ml to 1060 ml), for a range of intrinsic contrasts (three to ten times higher activity concentration in the lesion than breast background). Overall, nearly complete 3D acquisition schemes yield image data with relatively high lesion SNRs and contrasts and with minimal distortion of the uncompressed breast shape.


  • Experimental spectral measurements of heavy K-edge filtered beams for x-ray computed mammotomography

    by Dominic J. Crotty, Randolph L. McKinley, Martin P. Tornai

    A compact, dual modality computed mammotomography (CmT) and single photon emission computed tomography (SPECT) system for dedicated 3D breast imaging is in development. The CmT component utilizes novel, heavy K-edge filtration to practicably narrow the energy spectrum of the cone-shaped x-ray beam incident on the patient's pendant, uncompressed breast. This quasi-monochromatic beam in CmT is expected to improve discrimination of tissue with very similar attenuation coefficients while restraining dose levels to below that of existing dual view mammography. Our previous extensive simulation studies showed the optimal energy range that provides maximum dose efficiency for a 50/50 adipose/glandular breast is in the 35-40keV range. This current study aims to experimentally validate previous simulation results. Here, experimental pre-breast and post-breast collimated x-ray beam spectral measurements are made under tube operating voltages between 40-100kVp using filter materials from Z=13-74, with K-edge values spanning that of Ce (K=40.4keV), and using different attenuating thicknesses of filter material, approximately equivalent to the 200th and 500th attenuating value layer (VL) thickness. Ce-filtered post breast spectra for 8cm to 18cm breasts are measured for a range of breast adipose/glandular compositions. Evaluated figures of merit include mean beam energy, spectral full-width at tenth-maximum, beam hardening and dose for the range of breast sizes. Measurements are shown to corroborate the simulations, and both indicate that for a given dose a 200th VL of Ce filtration may have the most optimal performance in the dedicated mammotomography paradigm.


  • Development and Characterization of Novel Volumetric Acquisition Orbits With an Application Specific Emission Tomograph for Improved Breast Cancer Detection

    by Caryl N. Brzymialkiewicz, Martin P. Tornai

    The overall goal of this work is to develop, implement, and evaluate novel three-dimensional acquisition orbits used in conjunction with a dedicated emission mammotomography system, to be used as a potential secondary diagnostic tool. This novel nuclear medicine based molecular imaging technique utilizes camera trajectories that sample a pendant, uncompressed breast, which are evaluated with respect to various breast shapes and sizes. Phantom measurements have demonstrated that lesions near the chest wall can be visualized for both large and small sized breasts, and furthermore, that axillary imaging is possible even with minimal system tilt. The use of additional bed shielding, simulated here with a lead sheet, was also investigated. Preliminary results suggest the lead shield may hinder lesion detectability. Future work includes the addition of a patient bed, which is expected to further complicate positioning, and which may or may not include lead lining pending further studies.

  • Erratum: “Simulation study of a quasi-monochromatic beam for x-ray computed mammotomography” [Med. Phys. 31, 800-813 (2004)]

    by Randolph L. McKinley, Martin P. Tornai, Ehsan Samei, Marques L. Bradshaw


  • Development and Characterization of Novel Olumetric Acquisition Orbits With an Application Specific Emission Tomograph for Improved Breast Cancer Detection

    by Martin P. Tornai, Caryl N. Brzymialkiewicz

    Nuclear medicine based molecular imaging techniques can be used as an adjunct tool in the diagnosis of breast cancer, particularly for women with dense breast tissue. The dedicated emission mammotomograph is now fully functional; the tomographic gantry was enhanced by including an automated radius-of-rotation capability, to allow for fully 3D imaging of a pendant, uncompressed breast. As a result, novel 3D acquisition orbits have been developed to contour various sized breasts. Initial phantom measurements with a l6x20 sq cm field-of-view cadmium zinc telluride detector show the capability of the system to acquire data about concentric hemispheres of the breast, minimizing distance-dependent spatial resolution effects, maximizing the viewable breast volume while more-nearly- completely sampling the breast, and minimizing background contamination from the heart and liver. Results indicate 3D mamnotomography, incorporating a compact CZT detector and unique 3D camera trajectories, is a promising dedicated breast imaging technique for visualization of tumors less than 1cm in diameter. Future work includes evaluation of: patient bed shielding, sampling schemes for various shaped breasts, and axillary imaging.

    • 1 April 2003
      • Vol. 44  (4) , 583-93

    Mammotomography with pinhole incomplete circular orbit SPECT.

    by Martin P Tornai, James E Bowsher, Ronald J Jaszczak, Brett C Pieper, Kim L Greer, Patricia H Hardenbergh, R Edward Coleman

    Dedicated mammotomography with pinhole incomplete circular orbit (PICO) SPECT imaging of an uncompressed pendant breast was evaluated with small, very-high-stopping-power pinhole apertures. Comparisons were made with planar pinhole scintimammography. Enhanced 3-dimensional imaging performance with very-high-stopping-power apertures is thought to ultimately yield improved sensitivities for lesion detection and identification in breast disease. Pinhole collimators made of high-density and high atomic number (184)W or depleted (238)U, with aperture diameters from 1 to 4 mm, were used to image 0.6- and 1.0-cm-diameter spherical lesions in a pendulous, uncompressed breast phantom in planar and PICO-SPECT modes. The breast was centered on the horizontal axis of rotation of an incomplete circular orbit. Lesion, breast and body, and myocardial activities (L:B:M) were included in the phantoms to simulate clinical imaging conditions with (99m)Tc (140 keV). Lesion contrasts and signal-to-noise ratios (SNRs) for all apertures were determined for near clinical acquisition times for L:B:M ratios of 12:1:20 and 7:1:25. A set of minidisks inserted in the breast phantom was scanned to determine sampling limitations at depth from the nipple. In an initial study, a patient with biopsy-confirmed breast carcinoma was injected with 960 MBq (99m)Tc-tetrofosmin and scanned 2 h later with planar pinhole and PICO-SPECT techniques. Overall, for PICO-SPECT imaging there were small differences in measured counting rate sensitivity (4.9%) and lesion contrast (8.8%) with larger SNR differences (20.8%) between tungsten and depleted uranium pinhole materials at this energy and these lesion sizes. Backgrounds from simulated myocardial uptake had minor contributions in all reconstructed image volumes because of the rapid sensitivity fall-off for pinhole apertures. An optimal aperture diameter between 2 and 3 mm was determined from peak SNR, indicating that these aperture sizes may have the best performance for lesions as small as 0.6 cm in diameter with activity concentration ratios of (99m)Tc similar to those currently seen in patients. Both lesions were visualized with PICO-SPECT better than with planar pinhole imaging, with respective contrast improvements >20 times the values obtained from planar imaging for the same pinholes. In the patient study, higher contrast (>6) visualization of the active tumor periphery was obtained with PICO-SPECT than with planar imaging. These results indicate that the enhanced spatial resolution of smaller apertures outweighs the loss in sensitivity in small lesion identification with PICO-SPECT. Although the imaging differences between investigated aperture types are small and some limitations to this imaging approach exist, dedicated PICO-SPECT of the breast appears to be an improved technique compared with conventional planar pinhole scintimammography. This technique provides enhanced contrast and SNR for imaging small lesions with the high-resolution pinhole apertures along with 3-dimensional localization of the lesions.


  • A novel silicon array designed for intraoperative charged particle imaging

    by Martin P. Tornai, Bradley E. Patt, Jan S. Iwanczyk, Carolyn R. Tull, Lawrence R. MacDonald, Edward J. Hoffman

    A novel Si‐PIN imaging array is under investigation for a charged particle (beta, positron, or alpha) sensitive intraoperative camera to be used for (residual) tumor identification during surgery. This class of collimator‐less nuclear imaging device has a higher signal response for direct interactions than its scintillator‐optical detector‐based counterparts. Monte Carlo simulations with 635 keV betas were performed, yielding maximum and projected ranges of 1.64 and 0.55 mm in Si. Up to 90% of these betas were completely absorbed in the first 0.30 mm. Based on these results, 300 μm thick prototype Si detector arrays were designed in a 16×16 crossed‐grid arrangement with 0.8 mm wide orthogonal strips on 1.0 mm pitch. A NIM‐ and CAMAC‐based high‐density data acquisition and processing system was used to collect the list mode data. The system was calibrated by comparisons of measured spectra to energy deposition simulations or by direct measurement of various >100 keV conversion electron or beta emitters. Mean electronic noise per strip was in situimages of clinical relevance.