Lars Hegenbart
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lars Hegenbart has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Bastian Breustedt
Federal Office for Radiation Protection, Ingolstaedter Landstrasse 1, 85764, Oberschleissheim, Germany
2 shared publications J Y Zhang
Nuclear Engineering and Engineering Physics, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
1 shared publicationM Urban
Institut für Strahlenforschung, Forschungszentrum—Karlsruhe Institute of Technology, Karlsruhe, Germany
1 shared publicationM. Urban
Institut fuer Strahlenforschung—Karlsruher Institut fuer Technologie (KIT) , Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Karlsruhe , Germany
1 shared publicationO. Marzocchi
Institut fuer Strahlenforschung—Karlsruher Institut fuer Technologie (KIT) , Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Karlsruhe , Germany 2 DIEM Department , Faculty of Engineering of the University of Bologna , Bologna , Italy
1 shared publicationX George Xu
Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
1 shared publication
Latest Publications
- 25 November 2010
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 144 (1-4) , 389-392
A new position recording system for the partial-body counter at KIT
The position of detectors used for partial-body counters relative to a measured person has considerable influence on the counting efficiency of low-energy photon emitters. To minimise reading errors and enhance reproducibility of position data, an electronic position recording system was installed in the partial-body counter chamber at KIT. Phoswich detectors have been equipped with electronic sensors to determine the position and axes of the detectors. Additionally, a laser measurement system determines the position of arbitrary landmarks, e.g. point sources, anatomical features of phantoms and test persons. A network interface enables the reading of the position data on any connected computer. The system was successfully used to validate Monte Carlo simulations of partial-body counting scenarios for the numerical determination of counting efficiencies.
- 25 November 2010
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 144 (1-4) , 389-392
A new position recording system for the partial-body counter at KIT
The position of detectors used for partial-body counters relative to a measured person has considerable influence on the counting efficiency of low-energy photon emitters. To minimise reading errors and enhance reproducibility of position data, an electronic position recording system was installed in the partial-body counter chamber at KIT. Phoswich detectors have been equipped with electronic sensors to determine the position and axes of the detectors. Additionally, a laser measurement system determines the position of arbitrary landmarks, e.g. point sources, anatomical features of phantoms and test persons. A network interface enables the reading of the position data on any connected computer. The system was successfully used to validate Monte Carlo simulations of partial-body counting scenarios for the numerical determination of counting efficiencies.
- 20 March 2009
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 133 (3) , 158-164
Validation of a Monte Carlo efficiency calibration procedure for a partial body counter system with a voxel model of the LLNL torso phantom
Virtual models of real phantoms used with Monte Carlo methods facilitate the calibration and other studies associated with whole-body and partial-body counting systems. In this investigation, a voxel model of an LLNL torso phantom, available physically in the in vivo laboratory at KIT, was created from computed tomography scans. Series of measurements with a high-purity germanium detector and the real torso phantom, loaded with different radioactive organs, have been carried out. Computer simulations of these measurement setups were performed with the aid of MCNPX, using a coarsened voxel phantom and a validated model of the germanium detector. The results of simulations were compared with data from the measurements and an agreement within the uncertainties was found. The voxel model could therefore be validated. The results of the simulations were then used to quantify the activity of 241Am impurities detected in the liver loaded with 239Pu.
- 20 March 2009
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 133 (3) , 158-164
Validation of a Monte Carlo efficiency calibration procedure for a partial body counter system with a voxel model of the LLNL torso phantom
Virtual models of real phantoms used with Monte Carlo methods facilitate the calibration and other studies associated with whole-body and partial-body counting systems. In this investigation, a voxel model of an LLNL torso phantom, available physically in the in vivo laboratory at KIT, was created from computed tomography scans. Series of measurements with a high-purity germanium detector and the real torso phantom, loaded with different radioactive organs, have been carried out. Computer simulations of these measurement setups were performed with the aid of MCNPX, using a coarsened voxel phantom and a validated model of the germanium detector. The results of simulations were compared with data from the measurements and an agreement within the uncertainties was found. The voxel model could therefore be validated. The results of the simulations were then used to quantify the activity of 241Am impurities detected in the liver loaded with 239Pu.
- 9 September 2008
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 53 (19) , 5527-5538
A Monte Carlo study of lung counting efficiency for female workers of different breast sizes using deformable phantoms
There are currently no physical phantoms available for calibrating in vivo counting devices that represent women with different breast sizes because such phantoms are difficult, time consuming and expensive to fabricate. In this work, a feasible alternative involving computational phantoms was explored. A series of new female voxel phantoms with different breast sizes were developed and ported into a Monte Carlo radiation transport code for performing virtual lung counting efficiency calibrations. The phantoms are based on the RPI adult female phantom, a boundary representation (BREP) model. They were created with novel deformation techniques and then voxelized for the Monte Carlo simulations. Eight models have been selected with cup sizes ranging from AA to G according to brassiere industry standards. Monte Carlo simulations of a lung counting system were performed with these phantoms to study the effect of breast size on lung counting efficiencies, which are needed to determine the activity of a radionuclide deposited in the lung and hence to estimate the resulting dose to the worker. Contamination scenarios involving three different radionuclides, namely Am-241, Cs-137 and Co-60, were considered. The results show that detector efficiencies considerably decrease with increasing breast size, especially for low energy photon emitting radionuclides. When the counting efficiencies of models with cup size AA were compared to those with cup size G, a difference of up to 50% was observed. The detector efficiencies for each radionuclide can be approximated by curve fitting in the total breast mass (polynomial of second order) or the cup size (power).
- 9 September 2008
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 53 (19) , 5527-5538
A Monte Carlo study of lung counting efficiency for female workers of different breast sizes using deformable phantoms
There are currently no physical phantoms available for calibrating in vivo counting devices that represent women with different breast sizes because such phantoms are difficult, time consuming and expensive to fabricate. In this work, a feasible alternative involving computational phantoms was explored. A series of new female voxel phantoms with different breast sizes were developed and ported into a Monte Carlo radiation transport code for performing virtual lung counting efficiency calibrations. The phantoms are based on the RPI adult female phantom, a boundary representation (BREP) model. They were created with novel deformation techniques and then voxelized for the Monte Carlo simulations. Eight models have been selected with cup sizes ranging from AA to G according to brassiere industry standards. Monte Carlo simulations of a lung counting system were performed with these phantoms to study the effect of breast size on lung counting efficiencies, which are needed to determine the activity of a radionuclide deposited in the lung and hence to estimate the resulting dose to the worker. Contamination scenarios involving three different radionuclides, namely Am-241, Cs-137 and Co-60, were considered. The results show that detector efficiencies considerably decrease with increasing breast size, especially for low energy photon emitting radionuclides. When the counting efficiencies of models with cup size AA were compared to those with cup size G, a difference of up to 50% was observed. The detector efficiencies for each radionuclide can be approximated by curve fitting in the total breast mass (polynomial of second order) or the cup size (power).