XLXinming Liu

Xinming Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xinming Liu has a total of 19 co-authors. Here are the top co-authors by number of shared publications:

  • Chris C. Shaw

    Univ Texas Houston, MD Anderson Canc Ctr, Dept Imaging Phys, Digital Imaging Res Lab, 1515 Holcombe Blvd, Houston, TX 77030 USA

    3 shared publications
  • Chao-Jen Lai

    Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Digital Imaging Res Lab, Houston, TX 77030 USA

    2 shared publications
  • Lingyun Chen

    Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Digital Imaging Res Lab, Houston, TX 77030 USA

    2 shared publications
  • Tao Han

    Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Digital Imaging Res Lab, Houston, TX 77030 USA

    2 shared publications
  • Tianpeng Wang

    Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Digital Imaging Res Lab, Houston, TX 77030 USA

    2 shared publications
  • C.C. Shaw

    Department of Imaging Physics, University of Texas M.D. Anderson Cancer Center, Houston, TX, USA

    1 shared publication

Latest Publications

  • Scan equalization digital radiography (SEDR) implemented with an amorphous selenium flat-panel detector: initial experience

    by Xinming Liu, Chao-Jen Lai, Lingyun Chen, Tao Han, Yuncheng Zhong, Youtao Shen, Tianpeng Wang, Chris C Shaw

    It is well recognized in projection radiography that low-contrast detectability suffers in heavily attenuating regions due to excessively low x-ray fluence to the image receptor and higher noise levels. Exposure equalization can improve image quality by increasing the x-ray exposure to heavily attenuating regions, resulting in a more uniform distribution of exposure to the detector. Image quality is also expected to be improved by using the slot-scan geometry to reject scattered radiation effectively without degrading primary x-rays. This paper describes the design of a prototype scan equalization digital radiography (SEDR) system implemented with an amorphous silicon (a-Si) thin-film transistor (TFT) array-based flat-panel detector. With this system, slot-scan geometry with alternate line erasure and readout (ALER) technique was used to achieve scatter rejection. A seven-segment beam height modulator assembly was mounted onto the fore collimator to regulate exposure regionally for chest radiography. The beam modulator assembly, consisting of micro linear motors, lead screw cartridge with lead (Pb) beam blockers attached, position feedback sensors and motor driver circuitry, has been tested and found to have an acceptable response for exposure equalization in chest radiography. An anthropomorphic chest phantom was imaged in the posterior-anterior (PA) view under clinical conditions. Scatter component, primary x-rays, scatterto-primary ratios (SPRs) and primary signal-to-noise ratios (PSNRs) were measured in the SEDR images to evaluate the rejection and redistribution of scattered radiation, and compared with those for conventional full-field imaging with and without anti-scatter grid methods. SPR reduction ratios (SPRRRs, defined as the differences between the non-grid full-field SPRs and the reduced SPRs divided by the former) yielded approximately 59% for the full-field imaging with grid and 82% for the SEDR technique in the lungs, and 77% for the full-field imaging with grid and 95% for the SEDR technique in the subdiaphragm. The SEDR technique demonstrated a substantial improvement in PSNRs over the anti-scatter grid technique. The improvements of PSNRs varied with the regions and are more pronounced in heavily attenuating regions.


  • Scatter rejection and low-contrast performance of a slot-scan digital chest radiography system with electronic aft-collimation: A chest phantom study

    by Xinming Liu, Chris C. Shaw, Chao-Jen Lai, Mustafa C. Altunbas, Lingyun Chen, Tao Han, Tianpeng Wang

    Anti-scatter grids have been widely used to reject scatter and increase the perceptibility of low-contrast object in chest radiography; however they also attenuate the primary x-rays, resulting in a substantial degradation of primary information. Compensation for this degradation requires the use of higher exposure technique hence higher dose to the patient. A more efficient approach to reject scatter is the slot-scan imaging technique which employs a narrow scanning x-ray fan beam in conjunction with a slit or slot shaped solid state detector or an area detector used with an aft-collimator. With this approach, scatter can be rejected effectively without the need to attenuate primary x-rays. This paper demonstrates an electronic aft-collimation method, referred to as the alternate line erasure and readout (ALER) technique, for implementing the slot-scan digital radiography with a modern flat-panel detector. With this technique, instead of first exposing the detector and then reading the image line by line, the image line on the leading edge of the scanning fan beam is reset to erase the scatter accumulated prior to the arrival of the fan beam x-rays, while the image line on the trailing edge of the scanning fan beam is read out to acquire the image signals following the fan-beam exposure. These reset and readout processes are alternated and repeated as the x-ray fan beam scans across the detector. An anthropomorphic chest phantom was imaged to evaluate the scatter rejection ability and the low-contrast performance for the ALER technique and compare them with those for the anti-scatter grid method in full-field chest imaging. With a projected beam width of 16 mm, the slot-scan/ALER technique resulted in an average reduction of the scatter-toprimary ratios by 81%, 84%, 82%, and 86% versus 65%, 73%, 74%, and 73% with the anti-scatter grid method in the lungs, mediastinum, retrocardium, and subdiaphragm, respectively. The average CNR for the slot-scan/ALER technique was found to improve by 135%, 133%, 176%, and 87% versus 15%, 15%, 38%, and -11% with the anti-scatter grid method in the mediastinum, retrocardium, subdiaphragm, and lungs, respectively. These results demonstrated that the slot-scan/ALER technique can be used to achieve equally effective scatter rejection but substantially higher lowcontrast performance than the anti-scatter grid method. (C) 2008 American Association of Physicists in Medicine.


  • Rejection and redistribution of scattered radiation in scan equalization digital radiography (SEDR): Simulation with spot images

    by Xinming Liu, Chris C. Shaw

    The anti-scatter grid has been widely used to reject scatter and increase the perceptibility of a low-contrast object in chest radiography; however, it also attenuated the primary x-rays, resulting in a substantial loss of information and an increased relative noise level in heavily attenuated regions. A more dose efficient approach to scatter rejection is the slot-scan imaging technique. Another problem in chest radiography is the low transmitted x-ray intensity in heavily attenuating regions. It results in a higher relative noise level, thus limiting the contrast sensitivity. A solution to this problem is through the exposure equalization technique, with which the incident x-ray intensity is regionally modulated to compensate for the differences of x-ray attenuation due to the anatomic variation. We are in the process of implementing the scan equalization digital radiography (SEDR) technique, which combines the advantages of slot-scan imaging and exposure equalization. However, associated with the use of exposure equalization is a redistribution of scattered radiation at the detector, which may impact on the benefit of using exposure equalization in conjunction with the slot-scan imaging geometry. In order to understand the scatter properties and their impact in SEDR, we have used spot collimated digital radiographic images to synthesize simulated SEDR images with which scatter components, primary signals, and scatter-to-primary ratios (SPRs) were measured. It was shown that the anti-scatter grid rejected approximately 70% and 80% of scattered radiation in lightly and heavily attenuated regions, respectively, while the slot-scan method can reject as high as 95% (with 1 cm slot width) of scattered radiation without attenuation of the primary x-rays. Using a simple model for scatter effects, we have also estimated and compared the contrast-to-noise ratio degradation factors (CNRDFs, i.e., the fraction by which CNR is reduced). It was found that for quantum limited situations, the slot-scan technique has resulted in a substantial improvement of the image quality, as indicated by higher estimated CNRDFs (less scatter). An estimated improvement of 40%-50% in the lungs, 50%-90% in the mediastinum, and 60%-110% in the subdiaphragm was achieved with the slot-scan over the anti-scatter grid method. Compared to slot-scan imaging, SEDR resulted in higher SPRs in the lungs and lower SPRs in the mediastinum. In the subdiaphragmatic regions, the SPRs remain about the same. This corresponds to lower CNRDFs in the lungs, higher CNRDFs in the mediastinum, and about the same CNRDFs in the subdiaphragmatic regions. It was shown that although SEDR has resulted in minimum improvement over slot-scan imaging in reducing the SPRs, it could improve the contrast sensitivity by raising the primary signal levels in heavily attenuating regions. This advantage needs to be further investigated in our continuing study of the SEDR technique.


  • Open Access

    An alternate line erasure and readout (ALER) method for implementing slot-scan imaging technique with a flat-panel detector-initial experiences

    by Xinming Liu, C.C. Shaw, M.C. Altunbas, Tianpeng Wang

    This paper describes and demonstrates an electronic collimation method, referred to as the alternate line erasure and readout (ALER) technique, for implementing slot-scan digital radiography technique with an amorphous silicon (a-Si) thin-film transistor (TFT) array based flat-panel detector. An amorphus selenium (a-Se) flat-panel detector was modified to implement the ALER technique for slot-scan imaging. A stepping-motor driven fore-collimator was mounted in front of an X-ray tube to generate a scanning X-ray fan beam. The scanning speed and magnification were adjusted to synchronize the fan beam motion with the image line readout rate. The image lines on the leading and trailing edges of the fan beam were tracked and alternately reset and read out, respectively. The former operation resulted in the erasure of the scatter signals accumulated in the leading edge image line prior to the arrival of the fan beam. The latter operation resulted in the acquisition of fan beam exposure data integrated in the trailing edge image line right after the fan beam passed. To demonstrate the scatter rejection capability of this technique, an anthropomorphic chest phantom was placed in PA position and scanned at a speed of 576 lines (8.0 cm)/s at 117 kVp and 32 mA. A tungsten bar is placed at the entrance side of the chest phantom to measure the scatter-to-primary ratio (SPR), scatter reduction factor (SRF), and contrast-to-noise ratio degradation factor (CNRDF) in the slot-scan images to evaluate the effectiveness of scatter rejection and the resultant improvement of image quality. SPR and CNRDF in the open-field images were also measured and used as the reference for comparison. A scatter reduction by 86.4 to 95.4% across lower lung and heart regions has been observed with slot-scan imaging. The CNRs have been found to be improved by a factor of 2 in the mediastinum areas over the open-field image as well.


  • a−Si:H/CsI(Tl) flat-panel versus computed radiography for chest imaging applications: image quality metrics measurement

    by Xinming Liu, Chris C. Shaw

    Amorphous silicon (a-Si:H) flat-panel (FP) imaging systems have recently become commercially available for both chest and mammographic imaging applications. It has been shown that this new detector technology offers better image quality and various operational advantages over the computed radiography (CR) which to date has been the most widely implemented and used digital radiography technique. However, most image quality measurements reported on flat-panel systems have been performed on prototype systems in laboratories while those for CR systems were typically independently performed and reported on in separate studies. To directly compare the two technologies, we have measured the image properties for a commercial amorphous silicon/cesium iodide [a-Si:H/CsI(Tl)] flat-panel based digital chest system and a commercial CR system under clinical imaging conditions. In this paper, measurements of image quality metrics, including the modulation transfer functions (MTFs), noise power spectra (NPSs), and detective quantum efficiencies (DQEs), for the FP and CR systems are presented and compared. Methods and issues related to these measurements are discussed. The results show that the flat-panel system has slightly lower MTF but significantly higher DQEs than the CR system. The DQEs of the flat-panel system were found to increase with the exposure while those of the CR system decrease slightly with the exposure.


  • Comparison of a-Si:H CsI flat-panel digital imaging systems with a CCD-based system, CR systems, and conventional screen-film systems: a contrast-detail phantom study

    by John X. Rong, Chris C. Shaw, Dennis A. Johnston, Michael R. Lemacks, Xinming Liu, Gary J. Whitman, Stephen K. Thompson, Kerry T. Krugh

    Low-contrast detail detectability was evaluated and compared for a flat-panel digital chest system, a computed radiography (CR) system and a conventional screen/film (SF) system. Images of a contrast-detail phantom were acquired using these three systems under identical conditions. Additional images were acquired at varied exposures to study the potential for reduction of patient exposure using the flat-panel system. The results demonstrated that in chest imaging, the flat-panel system performed significantly better than the CR and the SF systems while the latter two performed about the same. Alternatively, an exposure reduction of at least 50% is possible if the same performance is maintained. For mammographic imaging, detectability for microcalcifications ((mu) Cs) was evaluated and compared for a flat-panel based full-field digital mammography (FFDM) system, a charge-coupled device (CCD) -based small-field system, a high resolution CR system and a conventional SF system. Images of simulated calcifications of three size ranges were acquired and evaluated by readers for detectability of the (mu) Cs. A Receiver Operating Characteristics (ROC) analysis was also performed to compare the overall detection accuracy for these four mammographic imaging systems. Our results show that in both the detectability analysis and the ROC analysis, the flat-panel systems performed the best followed by the screen/film system. The CCD based system showed better detection accuracy compared to the CR system in the ROC analysis. However, there was no significant difference between the CCD and the CR systems in the detectability analysis.