Youcef El-Mohri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Youcef El-Mohri has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Larry E. Antonuk
University of Michigan
13 shared publications Qihua Zhao
Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan 48109
13 shared publicationsYi Wang
Department of Radiation Oncology, University of Michigan, Ann Arbor Michigan 48109, USA
7 shared publications- Amit Sawant
Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD 21201, USA
5 shared publications Yixin Li
Department of Radiation Oncology, University of Michigan Medical Center, Ann Arbor, Michigan 48109
5 shared publicationsHao Jiang
Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan 48109
4 shared publications
Latest Publications
- 31 March 2015
- Published by Wiley in Medical Physics
- Vol. 42 (4) , 2072-2084
Theoretical investigation of the design and performance of a dual energy (kV and MV) radiotherapy imager
In modern radiotherapy treatment rooms, megavoltage (MV) portal imaging and kilovoltage (kV) cone-beam CT (CBCT) imaging are performed using various active matrix flat-panel imager (AMFPI) designs. To expand the clinical utility of MV and kV imaging, MV AMFPIs incorporating thick, segmented scintillators and, separately, kV imaging using a beam's eye view geometry have been investigated by a number of groups. Motivated by these previous studies, it is of interest to explore to what extent it is possible to preserve the benefits of kV and MV imaging using a single AMFPI design, given the considerably different x ray energy spectra used for kV and MV imaging. In this paper, considerations for the design of such a dual energy imager are explored through examination of the performance of a variety of hypothetical AMFPIs based on x ray converters employing segmented scintillators.
- 31 March 2015
- Published by Wiley in Medical Physics
- Vol. 42 (4) , 2072-2084
Theoretical investigation of the design and performance of a dual energy (kV and MV) radiotherapy imager
In modern radiotherapy treatment rooms, megavoltage (MV) portal imaging and kilovoltage (kV) cone-beam CT (CBCT) imaging are performed using various active matrix flat-panel imager (AMFPI) designs. To expand the clinical utility of MV and kV imaging, MV AMFPIs incorporating thick, segmented scintillators and, separately, kV imaging using a beam's eye view geometry have been investigated by a number of groups. Motivated by these previous studies, it is of interest to explore to what extent it is possible to preserve the benefits of kV and MV imaging using a single AMFPI design, given the considerably different x ray energy spectra used for kV and MV imaging. In this paper, considerations for the design of such a dual energy imager are explored through examination of the performance of a variety of hypothetical AMFPIs based on x ray converters employing segmented scintillators.
- 3 February 2014
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 59 (4) , 797-818
Optimization of the performance of segmented scintillators for radiotherapy imaging through novel binning techniques
Thick, segmented crystalline scintillators have shown increasing promise as replacement x-ray converters for the phosphor screens currently used in active matrix flat-panel imagers (AMFPIs) in radiotherapy, by virtue of providing over an order of magnitude improvement in the detective quantum efficiency (DQE). However, element-to-element misalignment in current segmented scintillator prototypes creates a challenge for optimal registration with underlying AMFPI arrays, resulting in degradation of spatial resolution. To overcome this challenge, a methodology involving the use of a relatively high resolution AMFPI array in combination with novel binning techniques is presented. The array, which has a pixel pitch of 0.127 mm, was coupled to prototype segmented scintillators based on BGO, LYSO and CsI:Tl materials, each having a nominal element-to-element pitch of 1.016 mm and thickness of ∼ 1 cm. The AMFPI systems incorporating these prototypes were characterized at a radiotherapy energy of 6 MV in terms of modulation transfer function, noise power spectrum, DQE, and reconstructed images of a resolution phantom acquired using a cone-beam CT geometry. For each prototype, the application of 8 × 8 pixel binning to achieve a sampling pitch of 1.016 mm was optimized through use of an alignment metric which minimized misregistration and thereby improved spatial resolution. In addition, the application of alternative binning techniques that exclude the collection of signal near septal walls resulted in further significant improvement in spatial resolution for the BGO and LYSO prototypes, though not for the CsI:Tl prototype due to the large amount of optical cross-talk resulting from significant light spread between scintillator elements in that device. The efficacy of these techniques for improving spatial resolution appears to be enhanced for scintillator materials that exhibit mechanical hardness, high density and high refractive index, such as BGO. Moreover, materials that exhibit these properties as well as offer significantly higher light output than BGO, such as CdWO4, should provide the additional benefit of preserving DQE performance.
- 3 February 2014
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 59 (4) , 797-818
Optimization of the performance of segmented scintillators for radiotherapy imaging through novel binning techniques
Thick, segmented crystalline scintillators have shown increasing promise as replacement x-ray converters for the phosphor screens currently used in active matrix flat-panel imagers (AMFPIs) in radiotherapy, by virtue of providing over an order of magnitude improvement in the detective quantum efficiency (DQE). However, element-to-element misalignment in current segmented scintillator prototypes creates a challenge for optimal registration with underlying AMFPI arrays, resulting in degradation of spatial resolution. To overcome this challenge, a methodology involving the use of a relatively high resolution AMFPI array in combination with novel binning techniques is presented. The array, which has a pixel pitch of 0.127 mm, was coupled to prototype segmented scintillators based on BGO, LYSO and CsI:Tl materials, each having a nominal element-to-element pitch of 1.016 mm and thickness of ∼ 1 cm. The AMFPI systems incorporating these prototypes were characterized at a radiotherapy energy of 6 MV in terms of modulation transfer function, noise power spectrum, DQE, and reconstructed images of a resolution phantom acquired using a cone-beam CT geometry. For each prototype, the application of 8 × 8 pixel binning to achieve a sampling pitch of 1.016 mm was optimized through use of an alignment metric which minimized misregistration and thereby improved spatial resolution. In addition, the application of alternative binning techniques that exclude the collection of signal near septal walls resulted in further significant improvement in spatial resolution for the BGO and LYSO prototypes, though not for the CsI:Tl prototype due to the large amount of optical cross-talk resulting from significant light spread between scintillator elements in that device. The efficacy of these techniques for improving spatial resolution appears to be enhanced for scintillator materials that exhibit mechanical hardness, high density and high refractive index, such as BGO. Moreover, materials that exhibit these properties as well as offer significantly higher light output than BGO, such as CdWO4, should provide the additional benefit of preserving DQE performance.
- 3 April 2013
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (8) , 2733
Corrigendum: Development of active matrix flat panel imagers incorporating thin layers of polycrystalline HgI2 for mammographic x-ray imaging
- 3 April 2013
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (8) , 2733
Corrigendum: Development of active matrix flat panel imagers incorporating thin layers of polycrystalline HgI2 for mammographic x-ray imaging
- 16 February 2011
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (6) , 1509-1527
Low-dose megavoltage cone-beam CT imaging using thick, segmented scintillators
Megavoltage, cone-beam computed tomography (MV CBCT) employing an electronic portal imaging device (EPID) is a highly promising technique for providing soft-tissue visualization in image-guided radiotherapy. However, current EPIDs based on active matrix flat-panel imagers (AMFPIs), which are regarded as the gold standard for portal imaging and referred to as conventional MV AMFPIs, require high radiation doses to achieve this goal due to poor x-ray detection efficiency (∼2% at 6 MV). To overcome this limitation, the incorporation of thick, segmented, crystalline scintillators, as a replacement for the phosphor screens used in these AMFPIs, has been shown to significantly improve the detective quantum efficiency (DQE) performance, leading to improved image quality for projection imaging at low dose. Toward the realization of practical AMFPIs capable of low dose, soft-tissue visualization using MV CBCT imaging, two prototype AMFPIs incorporating segmented scintillators with ∼11 mm thick CsI:Tl and Bi(4)Ge(3)O(12) (BGO) crystals were evaluated. Each scintillator consists of 120 × 60 crystalline elements separated by reflective septal walls, with an element-to-element pitch of 1.016 mm. The prototypes were evaluated using a bench-top CBCT system, allowing the acquisition of 180 projection, 360° tomographic scans with a 6 MV radiotherapy photon beam. Reconstructed images of a spatial resolution phantom, as well as of a water-equivalent phantom, embedded with tissue equivalent objects having electron densities (relative to water) varying from ∼0.28 to ∼1.70, were obtained down to one beam pulse per projection image, corresponding to a scan dose of ∼4 cGy--a dose similar to that required for a single portal image obtained from a conventional MV AMFPI. By virtue of their significantly improved DQE, the prototypes provided low contrast visualization, allowing clear delineation of an object with an electron density difference of ∼2.76%. Results of contrast, noise and contrast-to-noise ratio are presented as a function of dose and compared to those from a conventional MV AMFPI.
- 16 February 2011
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (6) , 1509-1527
Low-dose megavoltage cone-beam CT imaging using thick, segmented scintillators
Megavoltage, cone-beam computed tomography (MV CBCT) employing an electronic portal imaging device (EPID) is a highly promising technique for providing soft-tissue visualization in image-guided radiotherapy. However, current EPIDs based on active matrix flat-panel imagers (AMFPIs), which are regarded as the gold standard for portal imaging and referred to as conventional MV AMFPIs, require high radiation doses to achieve this goal due to poor x-ray detection efficiency (∼2% at 6 MV). To overcome this limitation, the incorporation of thick, segmented, crystalline scintillators, as a replacement for the phosphor screens used in these AMFPIs, has been shown to significantly improve the detective quantum efficiency (DQE) performance, leading to improved image quality for projection imaging at low dose. Toward the realization of practical AMFPIs capable of low dose, soft-tissue visualization using MV CBCT imaging, two prototype AMFPIs incorporating segmented scintillators with ∼11 mm thick CsI:Tl and Bi(4)Ge(3)O(12) (BGO) crystals were evaluated. Each scintillator consists of 120 × 60 crystalline elements separated by reflective septal walls, with an element-to-element pitch of 1.016 mm. The prototypes were evaluated using a bench-top CBCT system, allowing the acquisition of 180 projection, 360° tomographic scans with a 6 MV radiotherapy photon beam. Reconstructed images of a spatial resolution phantom, as well as of a water-equivalent phantom, embedded with tissue equivalent objects having electron densities (relative to water) varying from ∼0.28 to ∼1.70, were obtained down to one beam pulse per projection image, corresponding to a scan dose of ∼4 cGy--a dose similar to that required for a single portal image obtained from a conventional MV AMFPI. By virtue of their significantly improved DQE, the prototypes provided low contrast visualization, allowing clear delineation of an object with an electron density difference of ∼2.76%. Results of contrast, noise and contrast-to-noise ratio are presented as a function of dose and compared to those from a conventional MV AMFPI.
- Open Access
- 4 June 2010
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (13) , 3659-3673
Monte Carlo investigations of the effect of beam divergence on thick, segmented crystalline scintillators for radiotherapy imaging
The use of thick, segmented scintillators in electronic portal imagers offers the potential for significant improvement in x-ray detection efficiency compared to conventional phosphor screens. Such improvement substantially increases the detective quantum efficiency (DQE), leading to the possibility of achieving soft-tissue visualization at clinically practical (i.e. low) doses using megavoltage (MV) cone-beam computed tomography. While these DQE increases are greatest at zero spatial frequency, they are diminished at higher frequencies as a result of degradation of spatial resolution due to lateral spreading of secondary radiation within the scintillator--an effect that is more pronounced for thicker scintillators. The extent of this spreading is even more accentuated for radiation impinging the scintillator at oblique angles of incidence due to beam divergence. In this paper, Monte Carlo simulations of radiation transport, performed to investigate and quantify the effects of beam divergence on the imaging performance of MV imagers based on two promising scintillators (BGO and CsI:Tl), are reported. In these studies, 10-40 mm thick scintillators, incorporating low-density polymer, or high-density tungsten septal walls, were examined for incident angles corresponding to that encountered at locations up to approximately 15 cm from the central beam axis (for an imager located 130 cm from a radiotherapy x-ray source). The simulations demonstrate progressively more severe spatial resolution degradation (quantified in terms of the effect on the modulation transfer function) as a function of increasing angle of incidence (as well as of the scintillator thickness). Since the noise power behavior was found to be largely independent of the incident angle, the dependence of the DQE on the incident angle is therefore primarily determined by the spatial resolution. The observed DQE degradation suggests that 10 mm thick scintillators are not strongly affected by beam divergence for detector areas up to approximately 30x30 cm2. For thicker scintillators, the area that is relatively unaffected is significantly reduced, requiring a focused scintillator geometry in order to preserve spatial resolution, and thus DQE.
- 4 June 2010
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (13) , 3659-3673
Open AccessMonte Carlo investigations of the effect of beam divergence on thick, segmented crystalline scintillators for radiotherapy imaging
The use of thick, segmented scintillators in electronic portal imagers offers the potential for significant improvement in x-ray detection efficiency compared to conventional phosphor screens. Such improvement substantially increases the detective quantum efficiency (DQE), leading to the possibility of achieving soft-tissue visualization at clinically practical (i.e. low) doses using megavoltage (MV) cone-beam computed tomography. While these DQE increases are greatest at zero spatial frequency, they are diminished at higher frequencies as a result of degradation of spatial resolution due to lateral spreading of secondary radiation within the scintillator--an effect that is more pronounced for thicker scintillators. The extent of this spreading is even more accentuated for radiation impinging the scintillator at oblique angles of incidence due to beam divergence. In this paper, Monte Carlo simulations of radiation transport, performed to investigate and quantify the effects of beam divergence on the imaging performance of MV imagers based on two promising scintillators (BGO and CsI:Tl), are reported. In these studies, 10-40 mm thick scintillators, incorporating low-density polymer, or high-density tungsten septal walls, were examined for incident angles corresponding to that encountered at locations up to approximately 15 cm from the central beam axis (for an imager located 130 cm from a radiotherapy x-ray source). The simulations demonstrate progressively more severe spatial resolution degradation (quantified in terms of the effect on the modulation transfer function) as a function of increasing angle of incidence (as well as of the scintillator thickness). Since the noise power behavior was found to be largely independent of the incident angle, the dependence of the DQE on the incident angle is therefore primarily determined by the spatial resolution. The observed DQE degradation suggests that 10 mm thick scintillators are not strongly affected by beam divergence for detector areas up to approximately 30x30 cm2. For thicker scintillators, the area that is relatively unaffected is significantly reduced, requiring a focused scintillator geometry in order to preserve spatial resolution, and thus DQE.
- 24 November 2009
- Published by Wiley in Medical Physics
- Vol. 36 (12) , 5707-5718
High‐DQE EPIDs based on thick, segmented BGO and CsI:Tl scintillators: Performance evaluation at extremely low dose
Purpose: Electronic portal imaging devices (EPIDs) based on active matrix, flat‐panel imagers (AMFPIs) have become the gold standard for portal imaging and are currently being investigated for megavoltage cone‐beam computed tomography (CBCT) and cone‐beam digital tomosynthesis (CBDT). However, the practical realization of such volumetric imaging techniques is constrained by the relatively low detective quantum efficiency (DQE) of AMFPI‐based EPIDs at radiotherapy energies, at 6 MV. In order to significantly improve DQE, the authors are investigating thick, segmented scintillators, consisting of 2D matrices of scintillating crystals separated by septal walls.Methods: A newly constructed segmented BGO scintillator (11.3 mm thick) and three segmented CsI:Tl scintillators (11.4, 25.6, and 40.0 mm thick) were evaluated using a 6 MV photon beam. X‐ray sensitivity, modulation transfer function, noise power spectrum, DQE, and phantom images were obtained using prototype EPIDs based on the four scintillators.Results: The BGO and CsI:Tl prototypes were found to exhibit improvement in DQE ranging from to 25 times that of a conventional AMFPI‐based EPID at zero spatial frequency. All four prototype EPIDs provide significantly improved contrast resolution at extremely low doses, extending down to a single beam pulse. In particular, the BGO prototype provides contrast resolution comparable to that of the conventional EPID, but at 20 times less dose, with spatial resolution sufficient for identifying the boundaries of low‐contrast objects. For this prototype, however, the BGO scintillator exhibited an undesirable radiation‐induced variation in x‐ray sensitivity.Conclusions: Prototype EPIDs based on thick, segmented BGO and CsI:Tl scintillators provide significantly improved portal imaging performance at extremely low dose (i.e., down to 1 beam pulse corresponding to), creating the possibility of soft‐tissue visualization using MV CBCT and CBDT at clinically practical dose.
- 24 November 2009
- Published by Wiley in Medical Physics
- Vol. 36 (12) , 5707-5718
High‐DQE EPIDs based on thick, segmented BGO and CsI:Tl scintillators: Performance evaluation at extremely low dose
Purpose: Electronic portal imaging devices (EPIDs) based on active matrix, flat‐panel imagers (AMFPIs) have become the gold standard for portal imaging and are currently being investigated for megavoltage cone‐beam computed tomography (CBCT) and cone‐beam digital tomosynthesis (CBDT). However, the practical realization of such volumetric imaging techniques is constrained by the relatively low detective quantum efficiency (DQE) of AMFPI‐based EPIDs at radiotherapy energies, at 6 MV. In order to significantly improve DQE, the authors are investigating thick, segmented scintillators, consisting of 2D matrices of scintillating crystals separated by septal walls.Methods: A newly constructed segmented BGO scintillator (11.3 mm thick) and three segmented CsI:Tl scintillators (11.4, 25.6, and 40.0 mm thick) were evaluated using a 6 MV photon beam. X‐ray sensitivity, modulation transfer function, noise power spectrum, DQE, and phantom images were obtained using prototype EPIDs based on the four scintillators.Results: The BGO and CsI:Tl prototypes were found to exhibit improvement in DQE ranging from to 25 times that of a conventional AMFPI‐based EPID at zero spatial frequency. All four prototype EPIDs provide significantly improved contrast resolution at extremely low doses, extending down to a single beam pulse. In particular, the BGO prototype provides contrast resolution comparable to that of the conventional EPID, but at 20 times less dose, with spatial resolution sufficient for identifying the boundaries of low‐contrast objects. For this prototype, however, the BGO scintillator exhibited an undesirable radiation‐induced variation in x‐ray sensitivity.Conclusions: Prototype EPIDs based on thick, segmented BGO and CsI:Tl scintillators provide significantly improved portal imaging performance at extremely low dose (i.e., down to 1 beam pulse corresponding to), creating the possibility of soft‐tissue visualization using MV CBCT and CBDT at clinically practical dose.
- 23 June 2009
- Published by Wiley in Medical Physics
- Vol. 36 (7) , 3340-3355
Active pixel imagers incorporating pixel‐level amplifiers based on polycrystalline‐silicon thin‐film transistors
Active matrix, flat‐panel imagers (AMFPIs) employing a 2D matrix of ‐Si addressing TFTs have become ubiquitous in many x‐ray imaging applications due to their numerous advantages. However, under conditions of low exposures and/or high spatial resolution, their signal‐to‐noise performance is constrained by the modest system gain relative to the electronic additive noise. In this article, a strategy for overcoming this limitation through the incorporation of in‐pixel amplification circuits, referred to as active pixel (AP) architectures, using polycrystalline‐silicon (poly‐Si) TFTs is reported. Compared to ‐Si, poly‐Si offers substantially higher mobilities, enabling higher TFT currents and the possibility of sophisticated AP designs based on both ‐ and ‐channel TFTs. Three prototype indirect detection arrays employing poly‐Si TFTs and a continuous ‐Si photodiode structure were characterized. The prototypes consist of an array (PSI‐1) that employs a pixel architecture with a single TFT, as well as two arrays (PSI‐2 and PSI‐3) that employ AP architectures based on three and five TFTs, respectively. While PSI‐1 serves as a reference with a design similar to that of conventional AMFPI arrays, PSI‐2 and PSI‐3 incorporate additional in‐pixel amplification circuitry. Compared to PSI‐1, results of x‐ray sensitivity demonstrate signal gains of and 20.9 for PSI‐2 and PSI‐3, respectively. These values are in reasonable agreement with design expectations, demonstrating that poly‐Si AP circuits can be tailored to provide a desired level of signal gain. PSI‐2 exhibits the same high levels of charge trapping as those observed for PSI‐1 and other conventional arrays employing a continuous photodiode structure. For PSI‐3, charge trapping was found to be significantly lower and largely independent of the bias voltage applied across the photodiode. MTF results indicate that the use of a continuous photodiode structure in PSI‐1, PSI‐2, and PSI‐3 results in optical fill factors that are close to unity. In addition, the greater complexity of PSI‐2 and PSI‐3 pixel circuits, compared to that of PSI‐1, has no observable effect on spatial resolution. Both PSI‐2 and PSI‐3 exhibit high levels of additive noise, resulting in no net improvement in the signal‐to‐noise performance of these early prototypes compared to conventional AMFPIs. However, faster readout rates, coupled with implementation of multiple sampling protocols allowed by the nondestructive nature of pixel readout, resulted in a significantly lower noise level of (rms) for PSI‐3.
- 23 June 2009
- Published by Wiley in Medical Physics
- Vol. 36 (7) , 3340-3355
Active pixel imagers incorporating pixel‐level amplifiers based on polycrystalline‐silicon thin‐film transistors
Active matrix, flat‐panel imagers (AMFPIs) employing a 2D matrix of ‐Si addressing TFTs have become ubiquitous in many x‐ray imaging applications due to their numerous advantages. However, under conditions of low exposures and/or high spatial resolution, their signal‐to‐noise performance is constrained by the modest system gain relative to the electronic additive noise. In this article, a strategy for overcoming this limitation through the incorporation of in‐pixel amplification circuits, referred to as active pixel (AP) architectures, using polycrystalline‐silicon (poly‐Si) TFTs is reported. Compared to ‐Si, poly‐Si offers substantially higher mobilities, enabling higher TFT currents and the possibility of sophisticated AP designs based on both ‐ and ‐channel TFTs. Three prototype indirect detection arrays employing poly‐Si TFTs and a continuous ‐Si photodiode structure were characterized. The prototypes consist of an array (PSI‐1) that employs a pixel architecture with a single TFT, as well as two arrays (PSI‐2 and PSI‐3) that employ AP architectures based on three and five TFTs, respectively. While PSI‐1 serves as a reference with a design similar to that of conventional AMFPI arrays, PSI‐2 and PSI‐3 incorporate additional in‐pixel amplification circuitry. Compared to PSI‐1, results of x‐ray sensitivity demonstrate signal gains of and 20.9 for PSI‐2 and PSI‐3, respectively. These values are in reasonable agreement with design expectations, demonstrating that poly‐Si AP circuits can be tailored to provide a desired level of signal gain. PSI‐2 exhibits the same high levels of charge trapping as those observed for PSI‐1 and other conventional arrays employing a continuous photodiode structure. For PSI‐3, charge trapping was found to be significantly lower and largely independent of the bias voltage applied across the photodiode. MTF results indicate that the use of a continuous photodiode structure in PSI‐1, PSI‐2, and PSI‐3 results in optical fill factors that are close to unity. In addition, the greater complexity of PSI‐2 and PSI‐3 pixel circuits, compared to that of PSI‐1, has no observable effect on spatial resolution. Both PSI‐2 and PSI‐3 exhibit high levels of additive noise, resulting in no net improvement in the signal‐to‐noise performance of these early prototypes compared to conventional AMFPIs. However, faster readout rates, coupled with implementation of multiple sampling protocols allowed by the nondestructive nature of pixel readout, resulted in a significantly lower noise level of (rms) for PSI‐3.
- 1 June 2008
- Published by Wiley in Medical Physics
- Vol. 35 (6Part18) , 2853
SU-HH-AUD C-01: Empirical Investigation of Flat-Panel Imagers Incorporating High-Efficiency, Segmented BGO and CsI:Tl Detectors for Radiotherapy Imaging
- 1 June 2008
- Published by Wiley in Medical Physics
- Vol. 35 (6Part18) , 2853
SU-HH-AUD C-01: Empirical Investigation of Flat-Panel Imagers Incorporating High-Efficiency, Segmented BGO and CsI:Tl Detectors for Radiotherapy Imaging
- Open Access
- 1 January 2008
- Published by Springer Nature in MRS Proceedings
- Vol. 1066, 457-462
Noise Characterization of Polycrystalline Silicon Thin Film Transistors for X-ray Imagers Based on Active Pixel Architectures
An examination of the noise of polycrystalline silicon thin film transistors, in the context of flat panel x-ray imager development, is reported. The study was conducted in the spirit of exploring how the 1/f, shot and thermal noise components of poly-Si TFTs, determined from current noise power spectral density measurements, as well as through calculation, can be used to assist in the development of imagers incorporating pixel amplification circuits based on such transistors.
- 1 January 2008
- Published by Springer Nature in MRS Proceedings
- Vol. 1066, 457-462
Open AccessNoise Characterization of Polycrystalline Silicon Thin Film Transistors for X-ray Imagers Based on Active Pixel Architectures
An examination of the noise of polycrystalline silicon thin film transistors, in the context of flat panel x-ray imager development, is reported. The study was conducted in the spirit of exploring how the 1/f, shot and thermal noise components of poly-Si TFTs, determined from current noise power spectral density measurements, as well as through calculation, can be used to assist in the development of imagers incorporating pixel amplification circuits based on such transistors.
- 28 November 2007
- Published by Wiley in Medical Physics
- Vol. 34 (12) , 4911-4922
Performance of a direct-detection active matrix flat panel dosimeter (AMFPD) for IMRT measurements
The dosimetric performance of a direct-detection active matrix flat panel dosimeter (AMFPD) is reported for intensity modulated radiation therapy (IMRT) measurements. The AMFPD consists of a-Si : H photodiodes and thin-film transistors deposited on a glass substrate with no overlying scintillator screen or metal plate. The device is operated at 0.8 frames per second in a continuous acquisition or fluoroscopic mode. The effect of the applied bias voltage across the photodiodes on the response of the AMFPD was evaluated because this parameter affects dark signal, lag contributions, and pixel sensitivity. In addition, the AMPFD response was evaluated as a function of dose, dose rate, and energy, for static fields at 10 cm depth. In continuous acquisition mode, the AMFPD maintained a linear dose response (r2 > 0.99999) up to at least 1040 cGy. In order to obtain reliable integrated dose results for IMRT fields, the effects of lag on the radiation signal were minimized by operating the system at the highest frame rate and at an appropriate reverse bias voltage. Segmental MLC and dynamic MLC IMRT fields were measured with the AMFPD, and the results were compared to film, using standard methods for reliable film dosimetry. Both AMFPD and film measurements were independently converted to dose in cGy. Gamma and chi values were calculated as indices of agreement. The results from the AMFPD were in excellent agreement with those from film. When 2% of D(max) and 2 mm of distance to agreement were used as the criteria, 98% of the region of interest (defined as the region where dose is greater than 5% of D(max)) satisfied [chi] < or = 1 on average across the cases that were tested.
- 28 November 2007
- Published by Wiley in Medical Physics
- Vol. 34 (12) , 4911-4922
Performance of a direct-detection active matrix flat panel dosimeter (AMFPD) for IMRT measurements
The dosimetric performance of a direct-detection active matrix flat panel dosimeter (AMFPD) is reported for intensity modulated radiation therapy (IMRT) measurements. The AMFPD consists of a-Si : H photodiodes and thin-film transistors deposited on a glass substrate with no overlying scintillator screen or metal plate. The device is operated at 0.8 frames per second in a continuous acquisition or fluoroscopic mode. The effect of the applied bias voltage across the photodiodes on the response of the AMFPD was evaluated because this parameter affects dark signal, lag contributions, and pixel sensitivity. In addition, the AMPFD response was evaluated as a function of dose, dose rate, and energy, for static fields at 10 cm depth. In continuous acquisition mode, the AMFPD maintained a linear dose response (r2 > 0.99999) up to at least 1040 cGy. In order to obtain reliable integrated dose results for IMRT fields, the effects of lag on the radiation signal were minimized by operating the system at the highest frame rate and at an appropriate reverse bias voltage. Segmental MLC and dynamic MLC IMRT fields were measured with the AMFPD, and the results were compared to film, using standard methods for reliable film dosimetry. Both AMFPD and film measurements were independently converted to dose in cGy. Gamma and chi values were calculated as indices of agreement. The results from the AMFPD were in excellent agreement with those from film. When 2% of D(max) and 2 mm of distance to agreement were used as the criteria, 98% of the region of interest (defined as the region where dose is greater than 5% of D(max)) satisfied [chi] < or = 1 on average across the cases that were tested.