Omid Sayadi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Omid Sayadi has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Mohammad B. Shamsollahi
Sch. of Electr. Eng., Sharif Univ. of Technol., Tehran, Iran
3 shared publications- Mohammad Bagher Shamsollahi
Department of Electrical Engineering, Sharif University of Technology, Tehran, Iran
3 shared publications - Gari D. Clifford
Emory University
2 shared publications Mohammad Bagher Shamsollahi
Sch. of Electr. Eng., Sharif Univ. of Technol., Tehran
2 shared publicationsM B Shamsollahi
1 shared publication- Reza Sameni
Emory University School of Medicine
1 shared publication
Latest Publications
- 1 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 58 (10) , 2748-2757
Life-Threatening Arrhythmia Verification in ICU Patients Using the Joint Cardiovascular Dynamical Model and a Bayesian Filter
In this paper, a novel nonlinear joint dynamical model is presented, which is based on a set of coupled ordinary differential equations of motion and a Gaussian mixture model representation of pulsatile cardiovascular (CV) signals. In the proposed framework, the joint interdependences of CV signals are incorporated by assuming a unique angular frequency that controls the limit cycle of the heart rate. Moreover, the time consequence of CV signals is controlled by the same phase parameter that results in the space dimensionality reduction. These joint equations together with linear assignments to observation are further used in the Kalman filter structure for estimation and tracking. Moreover, we propose a measure of signal fidelity by monitoring the covariance matrix of the innovation signals throughout the filtering procedure. Five categories of life-threatening arrhythmias were verified by simultaneously tracking the signal fidelity and the polar representation of the CV signal estimations. We analyzed data from Physiobank multiparameter databases (MIMIC I and II). Performance evaluation results demonstrated that the sensitivity of the detection ranges over 93.50% and 100.00%. In particular, the addition of more CV signals improved the positive predictivity of the proposed method to 99.27% for the total arrhythmic types. The method was also used for false arrhythmia suppression issued by ICU monitors, with an overall false suppression rate reduced from 42.3% to 9.9%. In addition, false critical ECG arrhythmia alarm rates were found to be, on average, 42.3%, with individual rates varying between 16.7% and 86.5%. The results illustrate that the method can contribute to, and enhance the performance of clinical life-threatening arrhythmia detection.
- 1 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 58 (10) , 2748-2757
Life-Threatening Arrhythmia Verification in ICU Patients Using the Joint Cardiovascular Dynamical Model and a Bayesian Filter
In this paper, a novel nonlinear joint dynamical model is presented, which is based on a set of coupled ordinary differential equations of motion and a Gaussian mixture model representation of pulsatile cardiovascular (CV) signals. In the proposed framework, the joint interdependences of CV signals are incorporated by assuming a unique angular frequency that controls the limit cycle of the heart rate. Moreover, the time consequence of CV signals is controlled by the same phase parameter that results in the space dimensionality reduction. These joint equations together with linear assignments to observation are further used in the Kalman filter structure for estimation and tracking. Moreover, we propose a measure of signal fidelity by monitoring the covariance matrix of the innovation signals throughout the filtering procedure. Five categories of life-threatening arrhythmias were verified by simultaneously tracking the signal fidelity and the polar representation of the CV signal estimations. We analyzed data from Physiobank multiparameter databases (MIMIC I and II). Performance evaluation results demonstrated that the sensitivity of the detection ranges over 93.50% and 100.00%. In particular, the addition of more CV signals improved the positive predictivity of the proposed method to 99.27% for the total arrhythmic types. The method was also used for false arrhythmia suppression issued by ICU monitors, with an overall false suppression rate reduced from 42.3% to 9.9%. In addition, false critical ECG arrhythmia alarm rates were found to be, on average, 42.3%, with individual rates varying between 16.7% and 86.5%. The results illustrate that the method can contribute to, and enhance the performance of clinical life-threatening arrhythmia detection.
- 18 August 2010
- Published by IOP Publishing in Physiological Measurement
- Vol. 31 (10) , 1309-1329
Synthetic ECG generation and Bayesian filtering using a Gaussian wave-based dynamical model
In this paper, we describe a Gaussian wave-based state space to model the temporal dynamics of electrocardiogram (ECG) signals. It is shown that this model may be effectively used for generating synthetic ECGs as well as separate characteristic waves (CWs) such as the atrial and ventricular complexes. The model uses separate state variables for each CW, i.e. P, QRS and T, and hence is capable of generating individual synthetic CWs as well as realistic ECG signals. The model is therefore useful for generating arrhythmias. Simulations of sinus bradycardia, sinus tachycardia, ventricular flutter, atrial fibrillation and ventricular tachycardia are presented. In addition, discrete versions of the equations are presented for a model-based Bayesian framework for denoising. This framework, together with an extended Kalman filter and extended Kalman smoother, was used for denoising the ECG for both normal rhythms and arrhythmias. For evaluating the denoising performance, the signal-to-noise ratio (SNR) improvement of the filter outputs and clinical parameter stability were studied. The results demonstrate superiority over a wide range of input SNRs, achieving a maximum 12.7 dB improvement. Results indicate that preventing clinically relevant distortion of the ECG is sensitive to the number of model parameters. Models are presented which do not exhibit such distortions. The approach presented in this paper may therefore serve as an effective framework for synthetic ECG generation and model-based filtering of noisy ECG recordings.
- 18 August 2010
- Published by IOP Publishing in Physiological Measurement
- Vol. 31 (10) , 1309-1329
Synthetic ECG generation and Bayesian filtering using a Gaussian wave-based dynamical model
In this paper, we describe a Gaussian wave-based state space to model the temporal dynamics of electrocardiogram (ECG) signals. It is shown that this model may be effectively used for generating synthetic ECGs as well as separate characteristic waves (CWs) such as the atrial and ventricular complexes. The model uses separate state variables for each CW, i.e. P, QRS and T, and hence is capable of generating individual synthetic CWs as well as realistic ECG signals. The model is therefore useful for generating arrhythmias. Simulations of sinus bradycardia, sinus tachycardia, ventricular flutter, atrial fibrillation and ventricular tachycardia are presented. In addition, discrete versions of the equations are presented for a model-based Bayesian framework for denoising. This framework, together with an extended Kalman filter and extended Kalman smoother, was used for denoising the ECG for both normal rhythms and arrhythmias. For evaluating the denoising performance, the signal-to-noise ratio (SNR) improvement of the filter outputs and clinical parameter stability were studied. The results demonstrate superiority over a wide range of input SNRs, achieving a maximum 12.7 dB improvement. Results indicate that preventing clinically relevant distortion of the ECG is sensitive to the number of model parameters. Models are presented which do not exhibit such distortions. The approach presented in this paper may therefore serve as an effective framework for synthetic ECG generation and model-based filtering of noisy ECG recordings.
- 15 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 57 (2) , 353-362
Robust Detection of Premature Ventricular Contractions Using a Wave-Based Bayesian Framework
Detection and classification of ventricular complexes from the ECG is of considerable importance in Holter and critical care patient monitoring, being essential for the timely diagnosis of dangerous heart conditions. Accurate detection of premature ventricular contractions (PVCs) is particularly important in relation to life-threatening arrhythmias. In this paper, we introduce a model-based dynamic algorithm for tracking the ECG characteristic waveforms using an extended Kalman filter. The algorithm can work on single or multiple leads. A "polargram''-a polar representation of the signal-is introduced, which is constructed using the Bayesian estimations of the state variables. The polargram allows the specification of a polar envelope for normal rhythms. Moreover, we propose a novel measure of signal fidelity by monitoring the covariance matrix of the innovation signals throughout the filtering procedure. PVCs are detected by simultaneous tracking the signal fidelity and the polar envelope. Five databases, including 40 records from MIT-BIH arrhythmia database, are used for differentiating normal, PVC, and other beats. Performance evaluation results show that the proposed method has an average detection accuracy of 99.10%, aggregate sensitivity of 98.77%, and aggregate positive predictivity of 97.47%. Furthermore, the method is capable of 100% accuracy for records that contain only PVCs and normal sinus beats. The results illustrate that the method can contribute to, and enhance the performance of clinical PVC detection.
- 15 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 57 (2) , 353-362
Robust Detection of Premature Ventricular Contractions Using a Wave-Based Bayesian Framework
Detection and classification of ventricular complexes from the ECG is of considerable importance in Holter and critical care patient monitoring, being essential for the timely diagnosis of dangerous heart conditions. Accurate detection of premature ventricular contractions (PVCs) is particularly important in relation to life-threatening arrhythmias. In this paper, we introduce a model-based dynamic algorithm for tracking the ECG characteristic waveforms using an extended Kalman filter. The algorithm can work on single or multiple leads. A "polargram''-a polar representation of the signal-is introduced, which is constructed using the Bayesian estimations of the state variables. The polargram allows the specification of a polar envelope for normal rhythms. Moreover, we propose a novel measure of signal fidelity by monitoring the covariance matrix of the innovation signals throughout the filtering procedure. PVCs are detected by simultaneous tracking the signal fidelity and the polar envelope. Five databases, including 40 records from MIT-BIH arrhythmia database, are used for differentiating normal, PVC, and other beats. Performance evaluation results show that the proposed method has an average detection accuracy of 99.10%, aggregate sensitivity of 98.77%, and aggregate positive predictivity of 97.47%. Furthermore, the method is capable of 100% accuracy for records that contain only PVCs and normal sinus beats. The results illustrate that the method can contribute to, and enhance the performance of clinical PVC detection.
- 25 February 2009
- Published by IOP Publishing in Physiological Measurement
- Vol. 30 (3) , 335-352
A model-based Bayesian framework for ECG beat segmentation
The study of electrocardiogram (ECG) waveform amplitudes, timings and patterns has been the subject of intense research, for it provides a deep insight into the diagnostic features of the heart's functionality. In some recent works, a Bayesian filtering paradigm has been proposed for denoising and compression of ECG signals. In this paper, it is shown that this framework may be effectively used for ECG beat segmentation and extraction of fiducial points. Analytic expressions for the determination of points and intervals are derived and evaluated on various real ECG signals. Simulation results show that the method can contribute to and enhance the clinical ECG beat segmentation performance.
- 25 February 2009
- Published by IOP Publishing in Physiological Measurement
- Vol. 30 (3) , 335-352
A model-based Bayesian framework for ECG beat segmentation
The study of electrocardiogram (ECG) waveform amplitudes, timings and patterns has been the subject of intense research, for it provides a deep insight into the diagnostic features of the heart's functionality. In some recent works, a Bayesian filtering paradigm has been proposed for denoising and compression of ECG signals. In this paper, it is shown that this framework may be effectively used for ECG beat segmentation and extraction of fiducial points. Analytic expressions for the determination of points and intervals are derived and evaluated on various real ECG signals. Simulation results show that the method can contribute to and enhance the clinical ECG beat segmentation performance.
- 21 March 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 55 (9) , 2240-2248
ECG Denoising and Compression Using a Modified Extended Kalman Filter Structure
This paper presents efficient denoising and lossy compression schemes for electrocardiogram (ECG) signals based on a modified extended Kalman filter (EKF) structure. We have used a previously introduced two-dimensional EKF structure and modified its governing equations to be extended to a 17-dimensional case. The new EKF structure is used not only for denoising, but also for compression, since it provides estimation for each of the new 15 model parameters. Using these specific parameters, the signal is reconstructed with regard to the dynamical equations of the model. The performances of the proposed method are evaluated using standard denoising and compression efficiency measures. For denosing, the SNR improvement criterion is used, while for compression, we have considered the compression ratio (CR), the percentage area difference (PAD), and the weighted diagnostic distortion (WDD) measure. Several Massachusetts Institute of Technology-Beth Israel Deaconess Medical Center (MIT-BIH) ECG databases are used for performance evaluation. Simulation results illustrate that both applications can contribute to and enhance the clinical ECG data denoising and compression performance. For denoising, an average SNR improvement of 10.16 dB was achieved, which is 1.8 dB more than the next benchmark methods such as MAB WT or EKF2. For compression, the algorithm was extended to include more than five Gaussian kernels. Results show a typical average CR of 11.37:1 with WDD < 1.73 %. Consequently, the proposed framework is suitable for a hybrid system that integrates these algorithmic approaches for clean ECG data storage or transmission scenarios with high output SNRs, high CRs, and low distortions.
- 21 March 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 55 (9) , 2240-2248
ECG Denoising and Compression Using a Modified Extended Kalman Filter Structure
This paper presents efficient denoising and lossy compression schemes for electrocardiogram (ECG) signals based on a modified extended Kalman filter (EKF) structure. We have used a previously introduced two-dimensional EKF structure and modified its governing equations to be extended to a 17-dimensional case. The new EKF structure is used not only for denoising, but also for compression, since it provides estimation for each of the new 15 model parameters. Using these specific parameters, the signal is reconstructed with regard to the dynamical equations of the model. The performances of the proposed method are evaluated using standard denoising and compression efficiency measures. For denosing, the SNR improvement criterion is used, while for compression, we have considered the compression ratio (CR), the percentage area difference (PAD), and the weighted diagnostic distortion (WDD) measure. Several Massachusetts Institute of Technology-Beth Israel Deaconess Medical Center (MIT-BIH) ECG databases are used for performance evaluation. Simulation results illustrate that both applications can contribute to and enhance the clinical ECG data denoising and compression performance. For denoising, an average SNR improvement of 10.16 dB was achieved, which is 1.8 dB more than the next benchmark methods such as MAB WT or EKF2. For compression, the algorithm was extended to include more than five Gaussian kernels. Results show a typical average CR of 11.37:1 with WDD < 1.73 %. Consequently, the proposed framework is suitable for a hybrid system that integrates these algorithmic approaches for clean ECG data storage or transmission scenarios with high output SNRs, high CRs, and low distortions.
- 17 December 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 55 (1) , 347-351
Model-Based Fiducial Points Extraction for Baseline Wandered Electrocardiograms
A fast algorithm based on the nonlinear dynamical model for the electrocardiogram (ECG) is presented for the precise extraction of the characteristic points of these signals with baseline drift. Using the adaptive bionic wavelet transform, the baseline wander is removed efficiently. In fact by the means of the bionic wavelet transform, the resolution in the time-frequency domain can be adaptively adjusted not only by the signal frequency but also by the signal instantaneous amplitude and its first-order differential, which results in a better baseline wander cancellation. At the next step the parameters of the model are chosen to have the least square error with the original ECG. Determining the precise position of the waveforms of an ECG signal with baseline wander is complicated due to the varying amplitudes of its waveforms, the ambiguous and changing form of the complex and the unknown drift. A model-based approach handles these complications, therefore a method based on this concept has been developed and the fiducial points are accurately detected using the center and spread parameters of Gaussian-functions of the model. Simulation results show that the proposed method has an average sensitivity of 99.58%, average detection accuracy of 99.64%, and specificity of 100%.
- 17 December 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 55 (1) , 347-351
Model-Based Fiducial Points Extraction for Baseline Wandered Electrocardiograms
A fast algorithm based on the nonlinear dynamical model for the electrocardiogram (ECG) is presented for the precise extraction of the characteristic points of these signals with baseline drift. Using the adaptive bionic wavelet transform, the baseline wander is removed efficiently. In fact by the means of the bionic wavelet transform, the resolution in the time-frequency domain can be adaptively adjusted not only by the signal frequency but also by the signal instantaneous amplitude and its first-order differential, which results in a better baseline wander cancellation. At the next step the parameters of the model are chosen to have the least square error with the original ECG. Determining the precise position of the waveforms of an ECG signal with baseline wander is complicated due to the varying amplitudes of its waveforms, the ambiguous and changing form of the complex and the unknown drift. A model-based approach handles these complications, therefore a method based on this concept has been developed and the fiducial points are accurately detected using the center and spread parameters of Gaussian-functions of the model. Simulation results show that the proposed method has an average sensitivity of 99.58%, average detection accuracy of 99.64%, and specificity of 100%.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2007 (1094687X) , 2548-2551
ECG Denoising Using Parameters of ECG Dynamical Model as the States of an Extended Kalman Filter
In this paper an efficient filtering procedure based on the extended Kalman filter (EKF) has been proposed. The method is based on a modified nonlinear dynamic model, previously introduced for the generation of synthetic ECG signals. We have suggested simple dynamics as the governing equations for the model parameters. Since we have not any observation for these new state variables, they are considered as hidden states. Quantitative evaluation of the proposed algorithm on the MIT-BIH signals shows that an average SNR improvement of 12 dB is achieved for a signal of -5 dB. The results show improved output SNRs compared to the EKF outputs in the absence of these new dynamics.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2007 (1094687X) , 2548-2551
ECG Denoising Using Parameters of ECG Dynamical Model as the States of an Extended Kalman Filter
In this paper an efficient filtering procedure based on the extended Kalman filter (EKF) has been proposed. The method is based on a modified nonlinear dynamic model, previously introduced for the generation of synthetic ECG signals. We have suggested simple dynamics as the governing equations for the model parameters. Since we have not any observation for these new state variables, they are considered as hidden states. Quantitative evaluation of the proposed algorithm on the MIT-BIH signals shows that an average SNR improvement of 12 dB is achieved for a signal of -5 dB. The results show improved output SNRs compared to the EKF outputs in the absence of these new dynamics.
- Open Access
- 19 March 2007
- Published by Springer Nature in EURASIP Journal on Advances in Signal Processing
- Vol. 2007 (1) , 041274
Multiadaptive Bionic Wavelet Transform: Application to ECG Denoising and Baseline Wandering Reduction
- 19 March 2007
- Published by Springer Nature in EURASIP Journal on Advances in Signal Processing
- Vol. 2007 (1) , 041274
Open AccessMultiadaptive Bionic Wavelet Transform: Application to ECG Denoising and Baseline Wandering Reduction
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. Supplement (1557170X) , 6597-6600
ECG Denoising with Adaptive Bionic Wavelet Transform
In this paper a new ECG denoising scheme is proposed using a novel adaptive wavelet transform, named bionic wavelet transform (BWT), which had been first developed based on a model of the active auditory system. There has been some outstanding features with the BWT such as nonlinearity, high sensitivity and frequency selectivity, concentrated energy distribution and its ability to reconstruct signal via inverse transform but the most distinguishing characteristic of BWT is that its resolution in the time–frequency domain can be adaptively adjusted not only by the signal frequency but also by the signal instantaneous amplitude and its first-order differential. Besides by optimizing the BWT parameters parallel to modifying a new threshold value, one can handle ECG denoising with results comparing to those of wavelet transform (WT). Preliminary tests of BWT application to ECG denoising were constructed on the signals of MIT-BIH
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. Supplement (1557170X) , 6597-6600
ECG Denoising with Adaptive Bionic Wavelet Transform
In this paper a new ECG denoising scheme is proposed using a novel adaptive wavelet transform, named bionic wavelet transform (BWT), which had been first developed based on a model of the active auditory system. There has been some outstanding features with the BWT such as nonlinearity, high sensitivity and frequency selectivity, concentrated energy distribution and its ability to reconstruct signal via inverse transform but the most distinguishing characteristic of BWT is that its resolution in the time–frequency domain can be adaptively adjusted not only by the signal frequency but also by the signal instantaneous amplitude and its first-order differential. Besides by optimizing the BWT parameters parallel to modifying a new threshold value, one can handle ECG denoising with results comparing to those of wavelet transform (WT). Preliminary tests of BWT application to ECG denoising were constructed on the signals of MIT-BIH