SGSatish K. Garg

Satish K. Garg

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Satish K. Garg has a total of 132 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Vitamin D Metabolites and Binding Protein Predict Preeclampsia in Women with Type 1 Diabetes

    by Clare B. Kelly, Carol L. Wagner, Judith R. Shary, Misti J. Leyva, Jeremy Y. Yu, Alicia J. Jenkins, Alison J. Nankervis, Kristian F. Hanssen, Satish K. Garg, James A. Scardo, et al.

    The risk for preeclampsia (PE) is enhanced ~4-fold by the presence of maternal type 1 diabetes (T1DM). Vitamin D is essential for healthy pregnancy. We assessed the total, bioavailable, and free concentrations of plasma 25-hydroxyvitamin D (25(OH)D), 1,25-dihydroxyvitamin D (1,25(OH)2D), and vitamin D binding protein (VDBP) at ~12, ~22, and ~32 weeks’ gestation (“Visits” (V) 1, 2, and 3, respectively) in 23 T1DM women who developed PE, 24 who remained normotensive, and 19 non-diabetic, normotensive women (reference controls). 25(OH)D deficiency was more frequent in diabetic than non-diabetic women (69% vs. 22%, p < 0.05), but no measure of 25(OH)D predicted PE. By contrast, higher 1,25(OH)2D concentrations at V2 (total, bioavailable, and free: p < 0.01) and V3 (bioavailable: p < 0.05; free: p < 0.01), lower concentrations of VDBP at V3 (p < 0.05), and elevated ratios of 1,25(OH)2D/VDBP (V2, V3: p < 0.01) and 1,25(OH)2D/25(OH)D (V3, p < 0.05) were all associated with PE, and significance persisted in multivariate analyses. In summary, in women with T1DM, concentrations of 1,25(OH)2D were higher, and VDBP lower, in the second and third trimesters in women who later developed PE than in those who did not. 1,25(OH)2D may serve as a new marker for PE risk and could be implicated in pathogenesis.


  • Open Access

    Improved Postprandial Glucose with Inhaled Technosphere Insulin Compared with Insulin Aspart in Patients with Type 1 Diabetes on Multiple Daily Injections: The STAT Study

    by Halis Kaan Akturk, Janet K. Snell-Bergeon, Amanda Rewers, Leslie J. Klaff, Bruce W. Bode, Anne L. Peters, Timothy S. Bailey, Satish K. Garg

    Background: The majority of therapies have generally targeted fasting glucose control, and current mealtime insulin therapies have longer time action profiles than that of endogenously secreted insulin. The primary purpose of this study was to assess both glucose time-in-range (TIR: 70–180 mg/dL) and postprandial glucose excursions (PPGE) in 1–4 h using a real-time continuous glucose monitor (CGM) with Technosphere insulin (TI) versus insulin aspart in patients with type 1 diabetes (T1DM) on multiple daily injections (MDI). Research Design and Methods: This pilot, investigator-led, collaborative, open-label, multicenter, clinical research trial enrolled 60 patients with T1DM with HbA1c levels ≥6.5% and ≤10%. Individuals were randomized to treatment with titrated TI ( n = 26) or titrated insulin aspart ( n = 34), stratified by baseline HbA1c levels (≤8% or >8%). All were required to wear a real-time CGM throughout the trial. All patients in the TI group were advised to take supplemental inhalations at 1 and 2 h after meals if indicated based on postprandial glucose (PPG) values. The coprimary outcomes were assessed both in the full intent-to-treat population and in those individuals randomized to TI who were compliant with supplemental doses ≥90% of the time ( n = 15). The CGM data were analyzed using linear regression models. Results: Overall, those treated with TI versus aspart achieved comparable TIR, but less time spent in hypoglycemia (P < 0.05). In the TI-compliant group ( n = 15), TIR was significantly greater (62.5% ± 2.6% vs. 53.8% ± 1.7%, P = 0.009) and time in hyperglycemia >180 mg/dL was lower (34.2% ± 2.7% vs. 41.0% ± 1.7%, P = 0.045) as compared with the aspart group. PPG was also significantly lower in the TI cohort at 60 and 90 min postmeal, and PPGE were lower in the TI-compliant group as compared with the aspart group over 1–4-h postmeal ( P < 0.05). In addition, there was weight gain in the aspart group compared with weight loss in the TI group ( P = 0.006) despite higher prandial TI insulin dose. Conclusions: We conclude that using TI appropriately at mealtimes with supplemental dosing improves prandial glucose (TIR and 1–4 h) control without any increase in time in hypoglycemia or weight gain in patients with T1DM on MDI. The study results support a larger study using a treat-to-target design to confirm these findings. Clinical trial reg. no. NCT03143816, clinicaltrials.gov .


  • Strategy for Mitigating DKA Risk in Patients with Type 1 Diabetes on Adjunctive Treatment with SGLT Inhibitors: A STICH Protocol

    by Satish K. Garg, Anne L. Peters, John B. Buse, Thomas Danne

    The only peer-reviewed journal focused on the rapidly moving field of 3D printing and related technologies, providing comprehensive coverage of academic research and industrial and commercial developments that have applications in medicine, education, food, and architecture.


  • Accuracy of a Factory-Calibrated, Real-Time Continuous Glucose Monitoring System During 10 Days of Use in Youth and Adults with Diabetes

    by R. Paul Wadwa, Lori M. Laffel, Viral N. Shah, Satish K. Garg

    Background: Frequent use of continuous glucose monitoring (CGM) systems is associated with improved glycemic outcomes in persons with diabetes, but the need for calibrations and sensor insertions are often barriers to adoption. In this study, we evaluated the performance of G6, a sixth-generation, factory-calibrated CGM system specified for 10-day wear. Methods: The study enrolled participants of ages 6 years and up with type 1 diabetes or insulin-treated type 2 diabetes at 11 sites in the United States. Participation involved one sensor wear period of up to 10 days. Adults wore the system on the abdomen; youth of ages 6–17 years could choose to wear it on the abdomen or upper buttocks. Clinic sessions for frequent comparison with reference blood glucose measurements took place on days 1, 4–5, 7, and/or 10. Participants of ages 13 years and up underwent purposeful supervised glucose manipulation during in-clinic sessions. During the study, participants calibrated the systems once daily. However, analysis was performed on glucose values that were derived from reprocessed raw sensor data, independently of self-monitored blood glucose values used for calibration. Reprocessing used assigned sensor codes and a factory-calibration algorithm. Performance evaluation included the proportion of CGM values that were within ±20% of reference glucose values >100 mg/dL or within ±20 mg/dL of reference glucose values ≤100 mg/dL (%20/20), the analogous %15/15, and the mean absolute relative difference (MARD, expressed as a percentage) between temporally matched CGM and reference values. Results: Data from 262 study participants (21,569 matched CGM reference pairs) were analyzed. The overall %15/15, %20/20, and MARD were 82.4%, 92.3%, and 10.0%, respectively. Matched pairs from 134 adults and 128 youth of ages 6–17 years were similar with respect to %20/20 (92.4% and 91.9%) and MARD (9.9% and 10.1%). Overall %20/20 values on days 1 and 10 of sensor wear were 88.6% and 90.6%, respectively. The system's “Urgent Low Soon” (predictive of hypoglycemia within 20 min) hypoglycemia alert was correctly provided 84% of the time within 30 min before impending biochemical hypoglycemia (Conclusion: The new factory-calibrated G6 real-time CGM system provides accurate readings for 10 days and removes several clinical barriers to broader CGM adoption.


  • Open Access

    Methyldopa blocks MHC class II binding to disease-specific antigens in autoimmune diabetes

    by David A. Ostrov, Aimon Alkanani, Kristen A. McDaniel, Stephanie Case, Erin E. Baschal, Laura Pyle, Sam Ellis, Bernadette Pöllinger, Katherine J. Seidl, Viral N. Shah, et al.

    Major histocompatibility (MHC) class II molecules are strongly associated with many autoimmune disorders. In type 1 diabetes (T1D), the DQ8 molecule is common, confers significant disease risk, and is involved in disease pathogenesis. We hypothesized that blocking DQ8 antigen presentation would provide therapeutic benefit by preventing recognition of self-peptides by pathogenic T cells. We used the crystal structure of DQ8 to select drug-like small molecules predicted to bind structural pockets in the MHC antigen–binding cleft. A limited number of the predicted compounds inhibited DQ8 antigen presentation in vitro, with 1 compound preventing insulin autoantibody production and delaying diabetes onset in an animal model of spontaneous autoimmune diabetes. An existing drug with a similar structure, methyldopa, specifically blocked DQ8 in patients with recent-onset T1D and reduced inflammatory T cell responses to insulin, highlighting the relevance of blocking disease-specific MHC class II antigen presentation to treat autoimmunity.


  • Continuous glucose monitoring in pregnant women with type 1 diabetes

    by Satish K Garg, Sarit Polsky


  • Open Access

    The Future of Continuous Glucose Monitoring

    by Satish K. Garg, Halis K. Akturk


  • Open Access

    Role of Mobile Technology to Improve Diabetes Care in Adults with Type 1 Diabetes: The Remote-T1D Study iBGStar® in Type 1 Diabetes Management

    by Satish K. Garg, Viral N. Shah, Halis K. Akturk, Christie Beatson, Janet K. Snell-Bergeon

    Introduction The role of mobile technology in patient-reported outcomes (PRO) and glycemic control in adults with type 1 diabetes (T1D) needs further evaluation. Methods The single-center, prospective, 6-month, open-label, investigator-initiated study randomized 100 subjects with T1D in a 1:1 fashion to a control group using self-monitoring of blood glucose (SMBG) with Accu-Chek Nano® and an intervention group using SMBG with iPhone plus glucose meter (iBGStar®). The primary endpoint was the change in PRO (hypoglycemia fear score, behavior and worry subscores). Secondary outcomes were the improvement in glycemic variability indices and the reduction in A1c values. Results Baseline demographics and glycosylated hemoglobin (A1c) values were similar in the two groups. There was a significant decrease in A1c value at 6 months in iBGStar® group compared to the control group (−0.16 vs. −0.51, p = 0.04). The total insulin dose increased significantly in the iBGStar® group at 3 months but did not change at 6 months. The hypoglycemia fear scale (PRO) improved in both groups at 6 months (−1.4 ± 10.0 vs. −3.9 ± 12.5, p = 0.32). Conclusion The use of iBGStar® resulted in better glycemic control and improvement in some PRO (hypoglycemia fear and behavior scores) compared to the control group at 6 months with no increased risk of hypoglycemia. Clinical trial registration ClinicalTrials.gov: NCT01825382. Funding Sanofi.