Martin Reaney
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Martin Reaney has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Colleen Christensen
Canadian Light Source Inc., 110 North Road, Saskatoon, SK, CanadaS7N 5C6
1 shared publicationDerek Lydiate
Agriculture and Agri-Food Canada, 107 Science Place, Saskatoon, SK, CanadaS7N 0X2
1 shared publicationJeff Terry
Department of Physics, Life Sciences Building, 3101 S. Dearborn, Illinois Institute of Technology, Chicago, IL 60616, USA
1 shared publicationLester Young
Agriculture and Agri-Food Canada, 107 Science Place, Saskatoon, SK, Canada S7N 0X2
1 shared publicationNeil Westcott
Agriculture and Agri-Food Canada, 107 Science Place, Saskatoon, SK, CanadaS7N 0X2
1 shared publication
Latest Publications
- Open Access
- 19 September 2007
- Published by Oxford University Press (OUP) in Annals of Botany
- Vol. 100 (6) , 1357-1365
Inferring the Geometry of Fourth-Period Metallic Elements in Arabidopsis thaliana Seeds using Synchrotron-Based Multi-Angle X-ray Fluorescence Mapping
Improving our knowledge of plant metal metabolism is facilitated by the use of analytical techniques to map the distribution of elements in tissues. One such technique is X-ray fluorescence (XRF), which has been used previously to map metal distribution in both two and three dimensions. One of the difficulties of mapping metal distribution in two dimensions is that it can be difficult to normalize for tissue thickness. When mapping metal distribution in three dimensions, the time required to collect the data can become a major constraint. In this article a compromise is suggested between two- and three-dimensional mapping using multi-angle XRF imaging. A synchrotron-based XRF microprobe was used to map the distribution of K, Ca, Mn, Fe, Ni, Cu and Zn in whole Arabidopsis thaliana seeds. Relative concentrations of each element were determined by measuring fluorescence emitted from a 10 µm excitation beam at 13 keV. XRF spectra were collected from an array of points with 25 or 30 µm steps. Maps were recorded at 0 and 90°, or at 0, 60 and 120° for each seed. Using these data, circular or ellipsoidal cross-sections were modelled, and from these an apparent pathlength for the excitation beam was calculated to normalize the data. Elemental distribution was mapped in seeds from ecotype Columbia-4 plants, as well as the metal accumulation mutants manganese accumulator 1 (man1) and nicotianamine synthetase (nasx). Multi-angle XRF imaging will be useful for mapping elemental distribution in plant tissues. It offers a compromise between two- and three-dimensional XRF mapping, as far as collection times, image resolution and ease of visualization. It is also complementary to other metal-mapping techniques. Mn, Fe and Cu had tissue-specific accumulation patterns. Metal accumulation patterns were different between seeds of the Col-4, man1 and nasx genotypes.
- 19 September 2007
- Published by Oxford University Press (OUP) in Annals of Botany
- Vol. 100 (6) , 1357-1365
Open AccessInferring the Geometry of Fourth-Period Metallic Elements in Arabidopsis thaliana Seeds using Synchrotron-Based Multi-Angle X-ray Fluorescence Mapping
Improving our knowledge of plant metal metabolism is facilitated by the use of analytical techniques to map the distribution of elements in tissues. One such technique is X-ray fluorescence (XRF), which has been used previously to map metal distribution in both two and three dimensions. One of the difficulties of mapping metal distribution in two dimensions is that it can be difficult to normalize for tissue thickness. When mapping metal distribution in three dimensions, the time required to collect the data can become a major constraint. In this article a compromise is suggested between two- and three-dimensional mapping using multi-angle XRF imaging. A synchrotron-based XRF microprobe was used to map the distribution of K, Ca, Mn, Fe, Ni, Cu and Zn in whole Arabidopsis thaliana seeds. Relative concentrations of each element were determined by measuring fluorescence emitted from a 10 µm excitation beam at 13 keV. XRF spectra were collected from an array of points with 25 or 30 µm steps. Maps were recorded at 0 and 90°, or at 0, 60 and 120° for each seed. Using these data, circular or ellipsoidal cross-sections were modelled, and from these an apparent pathlength for the excitation beam was calculated to normalize the data. Elemental distribution was mapped in seeds from ecotype Columbia-4 plants, as well as the metal accumulation mutants manganese accumulator 1 (man1) and nicotianamine synthetase (nasx). Multi-angle XRF imaging will be useful for mapping elemental distribution in plant tissues. It offers a compromise between two- and three-dimensional XRF mapping, as far as collection times, image resolution and ease of visualization. It is also complementary to other metal-mapping techniques. Mn, Fe and Cu had tissue-specific accumulation patterns. Metal accumulation patterns were different between seeds of the Col-4, man1 and nasx genotypes.