Jean C. Krause
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jean C. Krause has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
Louis D. Braida
Massachusetts Institute of Technology Research Laboratory of Electronics Cambridge, Massachusetts 02139
3 shared publicationsB. Schick
1 shared publicationJ. A. Kegl
1 shared publication
Latest Publications
- 1 May 2009
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 125 (5) , 3346-3357
Evaluating the role of spectral and envelope characteristics in the intelligibility advantage of clear speech
In adverse listening conditions, talkers can increase their intelligibility by speaking clearly [Picheny, M.A., et al. (1985). J. Speech Hear. Res.28, 96–103; Payton, K. L., et al. (1994). J. Acoust. Soc. Am.95, 1581–1592]. This modified speaking style, known as clear speech, is typically spoken more slowly than conversational speech [Picheny, M. A., et al. (1986). J. Speech Hear. Res.29, 434–446; Uchanski, R. M., et al. (1996). J. Speech Hear. Res.39, 494–509]. However, talkers can produce clear speech at normal rates (clear/normal speech) with training [Krause, J. C., and Braida, L. D. (2002). J. Acoust. Soc. Am.112, 2165–2172] suggesting that clear speech has some inherent acoustic properties, independent of rate, that contribute to its improved intelligibility. Identifying these acoustic properties could lead to improved signal processing schemes for hearing aids. Two global-level properties of clear/normal speech that appear likely to be associated with improved intelligibility are increased energy in the 1000 – 3000 - Hz range of long-term spectra and increased modulation depth of low-frequency modulations of the intensity envelope [Krause, J. C., and Braida, L. D. (2004). J. Acoust. Soc. Am.115, 362–378]. In an attempt to isolate the contributions of these two properties to intelligibility, signal processing transformations were developed to manipulate each of these aspects of conversational speech independently. Results of intelligibility testing with hearing-impaired listeners and normal-hearing listeners in noise suggest that (1) increasing energy between 1000 and 3000 Hz does not fully account for the intelligibility benefit of clear/normal speech, and (2) simple filtering of the intensity envelope is generally detrimental to intelligibility. While other manipulations of the intensity envelope are required to determine conclusively the role of this factor in intelligibility, it is also likely that additional properties important for highly intelligible speech at normal speech at normal rates remain to be identified.
- 1 May 2009
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 125 (5) , 3346-3357
Evaluating the role of spectral and envelope characteristics in the intelligibility advantage of clear speech
In adverse listening conditions, talkers can increase their intelligibility by speaking clearly [Picheny, M.A., et al. (1985). J. Speech Hear. Res.28, 96–103; Payton, K. L., et al. (1994). J. Acoust. Soc. Am.95, 1581–1592]. This modified speaking style, known as clear speech, is typically spoken more slowly than conversational speech [Picheny, M. A., et al. (1986). J. Speech Hear. Res.29, 434–446; Uchanski, R. M., et al. (1996). J. Speech Hear. Res.39, 494–509]. However, talkers can produce clear speech at normal rates (clear/normal speech) with training [Krause, J. C., and Braida, L. D. (2002). J. Acoust. Soc. Am.112, 2165–2172] suggesting that clear speech has some inherent acoustic properties, independent of rate, that contribute to its improved intelligibility. Identifying these acoustic properties could lead to improved signal processing schemes for hearing aids. Two global-level properties of clear/normal speech that appear likely to be associated with improved intelligibility are increased energy in the 1000 – 3000 - Hz range of long-term spectra and increased modulation depth of low-frequency modulations of the intensity envelope [Krause, J. C., and Braida, L. D. (2004). J. Acoust. Soc. Am.115, 362–378]. In an attempt to isolate the contributions of these two properties to intelligibility, signal processing transformations were developed to manipulate each of these aspects of conversational speech independently. Results of intelligibility testing with hearing-impaired listeners and normal-hearing listeners in noise suggest that (1) increasing energy between 1000 and 3000 Hz does not fully account for the intelligibility benefit of clear/normal speech, and (2) simple filtering of the intensity envelope is generally detrimental to intelligibility. While other manipulations of the intensity envelope are required to determine conclusively the role of this factor in intelligibility, it is also likely that additional properties important for highly intelligible speech at normal speech at normal rates remain to be identified.
- Open Access
- 27 November 2007
- Published by Oxford University Press (OUP) in Journal of Deaf Studies and Deaf Education
- Vol. 13 (3) , 432-450
Toward Extending the Educational Interpreter Performance Assessment to Cued Speech
The Educational Interpreter Performance Assessment (EIPA) is as an important research tool for examining the quality of interpreters who use American Sign Language or a sign system in classroom settings, but it is not currently applicable to educational interpreters who use Cued Speech (CS). In order to determine the feasibility of extending the EIPA to include CS, a pilot EIPA test was developed and administered to 24 educational CS interpreters. Fifteen of the interpreters' performances were evaluated two to three times in order to assess reliability. Results show that the instrument has good construct validity and test-retest reliability. Although more interrater reliability data are needed, intrarater reliability was quite high (0.9), suggesting that the pilot test can be rated as reliably as signing versions of the EIPA. Notably, only 48% of interpreters who formally participated in pilot testing performed at a level that could be considered minimally acceptable. In light of similar performance levels previously reported for interpreters who sign (e.g., Schick, Williams, & Kupermintz, 2006), these results suggest that interpreting services for deaf and hard-of hearing students, regardless of the communication option used, are often inadequate and could seriously hinder access to the classroom environment.
- 27 November 2007
- Published by Oxford University Press (OUP) in Journal of Deaf Studies and Deaf Education
- Vol. 13 (3) , 432-450
Open AccessToward Extending the Educational Interpreter Performance Assessment to Cued Speech
The Educational Interpreter Performance Assessment (EIPA) is as an important research tool for examining the quality of interpreters who use American Sign Language or a sign system in classroom settings, but it is not currently applicable to educational interpreters who use Cued Speech (CS). In order to determine the feasibility of extending the EIPA to include CS, a pilot EIPA test was developed and administered to 24 educational CS interpreters. Fifteen of the interpreters' performances were evaluated two to three times in order to assess reliability. Results show that the instrument has good construct validity and test-retest reliability. Although more interrater reliability data are needed, intrarater reliability was quite high (0.9), suggesting that the pilot test can be rated as reliably as signing versions of the EIPA. Notably, only 48% of interpreters who formally participated in pilot testing performed at a level that could be considered minimally acceptable. In light of similar performance levels previously reported for interpreters who sign (e.g., Schick, Williams, & Kupermintz, 2006), these results suggest that interpreting services for deaf and hard-of hearing students, regardless of the communication option used, are often inadequate and could seriously hinder access to the classroom environment.
- 31 December 2003
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 115 (1) , 362-378
Acoustic properties of naturally produced clear speech at normal speaking rates
Sentences spoken “clearly” are significantly more intelligible than those spoken “conversationally” for hearing-impaired listeners in a variety of backgrounds [Picheny et al., J. Speech Hear. Res. 28, 96–103 (1985); Uchanski et al., ibid. 39, 494–509 (1996); Payton et al., J. Acoust. Soc. Am. 95, 1581–1592 (1994)]. While producing clear speech, however, talkers often reduce their speaking rate significantly [Picheny et al., J. Speech Hear. Res. 29, 434–446 (1986); Uchanski et al., ibid. 39, 494–509 (1996)]. Yet speaking slowly is not solely responsible for the intelligibility benefit of clear speech (over conversational speech), since a recent study [Krause and Braida, J. Acoust. Soc. Am. 112, 2165–2172 (2002)] showed that talkers can produce clear speech at normal rates with training. This finding suggests that clear speech has inherent acoustic properties, independent of rate, that contribute to improved intelligibility. Identifying these acoustic properties could lead to improved signal processing schemes for hearing aids. To gain insight into these acoustical properties, conversational and clear speech produced at normal speaking rates were analyzed at three levels of detail (global, phonological, and phonetic). Although results suggest that talkers may have employed different strategies to achieve clear speech at normal rates, two global-level properties were identified that appear likely to be linked to the improvements in intelligibility provided by clear/normal speech: increased energy in the 1000–3000-Hz range of long-term spectra and increased modulation depth of low frequency modulations of the intensity envelope. Other phonological and phonetic differences associated with clear/normal speech include changes in (1) frequency of stop burst releases, (2) VOT of word-initial voiceless stop consonants, and (3) short-term vowel spectra.
- 31 December 2003
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 115 (1) , 362-378
Acoustic properties of naturally produced clear speech at normal speaking rates
Sentences spoken “clearly” are significantly more intelligible than those spoken “conversationally” for hearing-impaired listeners in a variety of backgrounds [Picheny et al., J. Speech Hear. Res. 28, 96–103 (1985); Uchanski et al., ibid. 39, 494–509 (1996); Payton et al., J. Acoust. Soc. Am. 95, 1581–1592 (1994)]. While producing clear speech, however, talkers often reduce their speaking rate significantly [Picheny et al., J. Speech Hear. Res. 29, 434–446 (1986); Uchanski et al., ibid. 39, 494–509 (1996)]. Yet speaking slowly is not solely responsible for the intelligibility benefit of clear speech (over conversational speech), since a recent study [Krause and Braida, J. Acoust. Soc. Am. 112, 2165–2172 (2002)] showed that talkers can produce clear speech at normal rates with training. This finding suggests that clear speech has inherent acoustic properties, independent of rate, that contribute to improved intelligibility. Identifying these acoustic properties could lead to improved signal processing schemes for hearing aids. To gain insight into these acoustical properties, conversational and clear speech produced at normal speaking rates were analyzed at three levels of detail (global, phonological, and phonetic). Although results suggest that talkers may have employed different strategies to achieve clear speech at normal rates, two global-level properties were identified that appear likely to be linked to the improvements in intelligibility provided by clear/normal speech: increased energy in the 1000–3000-Hz range of long-term spectra and increased modulation depth of low frequency modulations of the intensity envelope. Other phonological and phonetic differences associated with clear/normal speech include changes in (1) frequency of stop burst releases, (2) VOT of word-initial voiceless stop consonants, and (3) short-term vowel spectra.
- 1 October 1996
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 100 (4_Suppleme) , 2828
Properties of naturally produced clear speech at normal speaking rates
- 1 October 1996
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 100 (4_Suppleme) , 2828
Properties of naturally produced clear speech at normal speaking rates