Jean-Louis Bourgain
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jean-Louis Bourgain has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
P Ravussin
3 shared publicationsA M Cros
2 shared publicationsG. Gueret
Service d’anesthésie-réanimation, institut Gustave-Roussy, rue Camille-Desmoulins, 94800 Villejuif, France
2 shared publicationsM. Fischler
Service d’anesthésie-réanimation, institut Gustave-Roussy, rue Camille-Desmoulins, 94800 Villejuif, France
2 shared publicationsV. Billard
Service d'Anesthésie, Institut Gustave Roussy 39 rue C Desmoulins, 94805 Villejuif, France
2 shared publicationsA. Laplanche
1 shared publication
Latest Publications
- 1 October 2010
- Published by Elsevier in Annales Françaises d'Anesthésie et de Réanimation
- Vol. 29 (10) , 720-727
Guide d’utilisation de la jet-ventilation en chirurgie ORL, trachéale et maxillo-faciale
- 1 October 2010
- Published by Elsevier in Annales Françaises d'Anesthésie et de Réanimation
- Vol. 29 (10) , 720-727
Guide d’utilisation de la jet-ventilation en chirurgie ORL, trachéale et maxillo-faciale
- Open Access
- 1 October 2008
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 101 (4) , 573-574
Safety and jet ventilation
Editor—Cook and Alexander1 confirm that the practice of jet ventilation may be dangerous when applied without control of the driving pressure and tracheal pressure. However, we would like first to point out that we are not the authors of the following sentence ‘caution against use of TTJV when ventilation from supraglottic or subglottic catheters can be used, as risk of iatrogenic injury is too high’.2 In fact, our opinion is the exact opposite: laryngeal surgery, and especially laryngeal endoscopy, is optimally performed under transtracheal high-frequency jet ventilation. The reason is, as stated by Cook and Alexander, ‘the main advantage of transtracheal techniques is that it provides the surgeon with operating conditions unhindered by anaesthetic equipment or the need for the surgeon to maintain ventilation’.1 In a nationwide survey on anaesthetic management of laryngeal laser surgery, Cozine and colleagues3 did not show any difference between jet ventilation and tracheal intubation, but demonstrated that rate of complications was directly related to the number of surgeries performed under jet ventilation each year. In other words, we do well what we do often! Most laryngeal invasive endoscopic procedures are planned and simply cannot be performed without adequate equipment, particularly a jet ventilator which automatically cuts off ventilation when end-expiratory pressure exceeds a preset level.
- 1 October 2008
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 101 (4) , 573-574
Open AccessSafety and jet ventilation
Editor—Cook and Alexander1 confirm that the practice of jet ventilation may be dangerous when applied without control of the driving pressure and tracheal pressure. However, we would like first to point out that we are not the authors of the following sentence ‘caution against use of TTJV when ventilation from supraglottic or subglottic catheters can be used, as risk of iatrogenic injury is too high’.2 In fact, our opinion is the exact opposite: laryngeal surgery, and especially laryngeal endoscopy, is optimally performed under transtracheal high-frequency jet ventilation. The reason is, as stated by Cook and Alexander, ‘the main advantage of transtracheal techniques is that it provides the surgeon with operating conditions unhindered by anaesthetic equipment or the need for the surgeon to maintain ventilation’.1 In a nationwide survey on anaesthetic management of laryngeal laser surgery, Cozine and colleagues3 did not show any difference between jet ventilation and tracheal intubation, but demonstrated that rate of complications was directly related to the number of surgeries performed under jet ventilation each year. In other words, we do well what we do often! Most laryngeal invasive endoscopic procedures are planned and simply cannot be performed without adequate equipment, particularly a jet ventilator which automatically cuts off ventilation when end-expiratory pressure exceeds a preset level.
- 1 January 2008
- Published by Elsevier in Annales Françaises d'Anesthésie et de Réanimation
- Vol. 27 (1) , 15-25
Désaturation artérielle en oxygène et maintien de l’oxygénation pendant l’intubation
- 1 January 2008
- Published by Elsevier in Annales Françaises d'Anesthésie et de Réanimation
- Vol. 27 (1) , 15-25
Désaturation artérielle en oxygène et maintien de l’oxygénation pendant l’intubation
- Open Access
- 2 December 2006
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 98 (1) , 136-140
Pressure support ventilation during fibreoptic intubation under propofol anaesthesia
Goal of the study. To assess the benefit of pressure support ventilation during fibreoptic intubation performed under propofol anaesthesia in patients having an anticipated difficult intubation. Procedures. Thirty-two patients with ENT cancer, and having at least two criteria for anticipated difficult intubation were prospectively included. All patients received topical lidocaine 2% and propofol by plasma target control infusion (initial target concentration 3 μg ml−1, then adjusted to maintain loss of consciousness without apnoea). They were randomly assigned between two groups: spontaneous breathing (SB) or pressure support ventilation (with a support level set at 10 cm H2O) both using Fi o2=1. Conditions for fibreoptic intubation, respiratory parameters (pulse oxymetry, ventilatory frequency, tidal volume and after intubation) and haemodynamic parameters were recorded. Results. Patient characteristic data and intubation conditions were similar between both groups. All patients had a successful fibreoptic intubation and none needed a rescue procedure because of desaturation. In spite of a longer duration of intubation, after intubation was lower and tidal volume during intubation was higher with pressure support ventilation than in SB patients [38.1 (4.2) vs 42.3 (4.7) mm Hg and 371 (139) vs 165 (98) ml, respectively]. Desaturation episodes were observed in two SB patients conversely to no episode during pressure support ventilation, probably because of the higher minute ventilation. Conclusion. Pressure support represents a useful method to improve ventilation during fibreoptic intubation under propofol anaesthesia in patients with an anticipated difficult intubation.- 2 December 2006
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 98 (1) , 136-140
Open AccessPressure support ventilation during fibreoptic intubation under propofol anaesthesia
Goal of the study. To assess the benefit of pressure support ventilation during fibreoptic intubation performed under propofol anaesthesia in patients having an anticipated difficult intubation. Procedures. Thirty-two patients with ENT cancer, and having at least two criteria for anticipated difficult intubation were prospectively included. All patients received topical lidocaine 2% and propofol by plasma target control infusion (initial target concentration 3 μg ml−1, then adjusted to maintain loss of consciousness without apnoea). They were randomly assigned between two groups: spontaneous breathing (SB) or pressure support ventilation (with a support level set at 10 cm H2O) both using Fi o2=1. Conditions for fibreoptic intubation, respiratory parameters (pulse oxymetry, ventilatory frequency, tidal volume and after intubation) and haemodynamic parameters were recorded. Results. Patient characteristic data and intubation conditions were similar between both groups. All patients had a successful fibreoptic intubation and none needed a rescue procedure because of desaturation. In spite of a longer duration of intubation, after intubation was lower and tidal volume during intubation was higher with pressure support ventilation than in SB patients [38.1 (4.2) vs 42.3 (4.7) mm Hg and 371 (139) vs 165 (98) ml, respectively]. Desaturation episodes were observed in two SB patients conversely to no episode during pressure support ventilation, probably because of the higher minute ventilation. Conclusion. Pressure support represents a useful method to improve ventilation during fibreoptic intubation under propofol anaesthesia in patients with an anticipated difficult intubation. - 1 September 2004
- Published by Elsevier in Annales Françaises d'Anesthésie et de Réanimation
- Vol. 23 (9) , 900-904
Morbidité de la chirurgie carcinologique cervicofaciale
- 1 September 2004
- Published by Elsevier in Annales Françaises d'Anesthésie et de Réanimation
- Vol. 23 (9) , 900-904
Morbidité de la chirurgie carcinologique cervicofaciale
- 1 November 1999
- Vol. 119 (11) , 857-60
[Control of the respiratory tract in anesthesia and resuscitation].
- 1 November 1999
- Vol. 119 (11) , 857-60
[Control of the respiratory tract in anesthesia and resuscitation].
- 1 November 1999
- Vol. 119 (11) , 865-70
[Specificity of difficult intubation in cervico-facial oncology].
- 1 November 1999
- Vol. 119 (11) , 865-70
[Specificity of difficult intubation in cervico-facial oncology].
- 1 June 1996
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 76
A.51 Prevention of postoperative sore throat during use of the laryngeal mask airway
- 1 June 1996
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 76
A.51 Prevention of postoperative sore throat during use of the laryngeal mask airway
- 1 June 1996
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 76
A.7 Early mortality after neck dissection
- 1 June 1996
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 76
A.7 Early mortality after neck dissection