CSCristina Solomon

Cristina Solomon

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Cristina Solomon has a total of 68 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    In search for in vivo methods to visualize clot forming in cut vessels and interrupted flow

    by C. Solomon, N. J. White, G. Hochleitner, M. Hermann, D. Fries

    Editor—A key aspect of improving care for patients suffering from life-threatening haemorrhage as a result of trauma or major perioperative bleeding, is a better understanding of mechanisms involved in coagulation and haemostasis around the injury site. Prevailing models of coagulation, like the cascade or waterfall model, 1 are limited, describing haemostasis as a set of complex interactions between coagulation factors and other blood components, but not taking into account the context in which haemostasis takes place at the injury site. However, decades ago it was established that other mechanisms, such as vasoconstriction and the formation of extraluminal soft clots, are key mechanisms involved in the initiation of haemostasis in ruptured vessels (see Table 1 for a selection of evidence from relevant studies). 2–5


  • Open Access

    Validation of viscoelastic coagulation tests during cardiopulmonary bypass: comment

    by C. Solomon, K. Fickenscher, L. Ormonde, M. Ranucci


  • Fibrinogen concentrate as first-line therapy in aortic surgery reduces transfusion requirements in patients with platelet counts over or under 100x109/L

    by Cristina Solomon, Niels Rahe-Meyer

    Administration of fibrinogen concentrate, targeting improved maximum clot firmness (MCF) of the thromboelastometric fibrin-based clot quality test (FIBTEM) is effective as first-line haemostatic therapy in aortic surgery. We performed a post-hoc analysis of data from a randomised, placebo-controlled trial of fibrinogen concentrate, to investigate whether fibrinogen concentrate reduced transfusion requirements for patients with platelet counts over or under 100×10(9)/L.Aortic surgery patients with coagulopathic bleeding after cardiopulmonary bypass were randomised to receive either fibrinogen concentrate (n=29) or placebo (n=32). Platelet count was measured upon removal of the aortic clamp, and coagulation and haematology parameters were measured peri-operatively. Transfusion of allogeneic blood components was recorded and compared between groups.After cardiopulmonary bypass, haemostatic and coagulation parameters worsened in all groups; plasma fibrinogen level (determined by the Clauss method) decreased by 43-58%, platelet count by 53-64%, FIBTEM maximum clot firmness (MCF) by 38-49%, FIBTEM maximum clot elasticity (MCE) by 43-54%, extrinsically activated test (EXTEM) MCF by 11-22%, EXTEM MCE by 25-41% and the platelet component of the clot by 23-39%. Treatment with fibrinogen concentrate (mean dose 7-9 g in the 4 groups) significantly reduced post-operative allogeneic blood component transfusion requirements when compared to placebo both for patients with a platelet count≥100×10(9)/L and for patients with a platelet count<100×10(9)/L.FIBTEM-guided administration of fibrinogen concentrate reduced transfusion requirements when used as a first-line haemostatic therapy during aortic surgery in patients with platelet counts over or under 100×10(9)/L.


  • Open Access

    Reply from the authors

    by C. Solomon, N. Rahe-Meyer


  • Open Access

    Time course of haemostatic effects of fibrinogen concentrate administration in aortic surgery

    by C. Solomon, C. Hagl, N. Rahe-Meyer

    There is currently a contrast between the demonstrated benefits of fibrinogen concentrate in correcting bleeding and reducing transfusion, and its perceived thrombogenic potential. This analysis evaluates the effects of fibrinogen concentrate on coagulation up to 12 days after administration during aortic surgery. We performed a post hoc analysis of a prospective, randomized, double-blind, controlled trial of fibrinogen concentrate as first-line haemostatic therapy in aortic surgery. After cardiopulmonary bypass (CPB) and protamine administration, subjects with coagulopathic bleeding received fibrinogen concentrate or placebo. The placebo group received allogeneic blood products, including fresh-frozen plasma (FFP; n=32); the fibrinogen concentrate group received fibrinogen concentrate alone (FC; n=14), or fibrinogen concentrate followed by allogeneic blood products (FC+FFP; n=15). Plasma fibrinogen, fibrin-based clotting (ROTEM(®)-based FIBTEM assay), and peri- and postoperative haematological and coagulation parameters were compared. Plasma fibrinogen and FIBTEM maximum clot firmness (MCF) decreased ∼50% during CPB but were corrected by FC or FC+FFP. At last suture, the highest values for plasma fibrinogen (360 mg dl(-1)) and FIBTEM MCF (22 mm) were within normal ranges--below the acute phase increases observed after surgery. In patients receiving only FFP as a source of fibrinogen, these parameters recovered marginally by last suture (P<0.001 vs FC and FC+FFP). All groups displayed comparable haemostasis at 24 h post-surgery. Fibrinogen concentrate did not cause alterations of other haemostasis parameters. Fibrinogen concentrate provided specific, significant, short-lived increases in plasma fibrinogen and fibrin-based clot firmness after aortic surgery.


  • In reply

    by Cristina Solomon, Niels Rahe-Meyer


  • Effect of haematocrit on fibrin-based clot firmness in the FIBTEM test

    by Cristina Solomon, Niels Rahe-Meyer, Herbert Schöchl, Marco Ranucci, Klaus Görlinger

    Point-of-care thromboelastometry (ROTEM(®)) can be used to assess coagulation in whole blood. In the ROTEM(®) FIBTEM test, cytochalasin D eliminates the contribution of platelets to the whole blood clot; hence, only the remaining elements, including fibrinogen/fibrin, red blood cells and factor XIII, contribute to clot strength. We investigated the relationships between FIBTEM maximum clot firmness (MCF), whole blood fibrinogen concentration and plasma fibrinogen concentration to determine the impact of haematocrit on these parameters during cardiac surgery. The relationships between FIBTEM MCF and both whole blood fibrinogen concentration and plasma fibrinogen concentration (Clauss assay) were evaluated pre-operatively and after cardiopulmonary bypass/protamine administration in haematocrit-based subgroups. The study included 157 patients. The correlation coefficient rho between FIBTEM MCF and plasma fibrinogen concentration was 0.68 at baseline and 0.70 after protamine, while that between FIBTEM MCF and whole blood fibrinogen concentration was 0.74 at baseline and 0.72 after protamine (all P <0.001). In subgroup analyses based on haematocrit levels, pre-operative FIBTEM MCF and whole blood fibrinogen concentration were both significantly higher (P <0.05) for the lowest haematocrit subgroup, but plasma fibrinogen concentration was similar in all groups. After protamine, no significant differences were observed between the lowest haematocrit group and the other groups for any of the three parameters. The effect of haematocrit on blood clotting is not reflected by plasma fibrinogen concentration, in contrast to FIBTEM MCF which incorporates the contribution of haematocrit to whole blood clot firmness. This effect does, however, appear to be negligible in haemodiluted patients.


  • Open Access

    Haemostatic monitoring during postpartum haemorrhage and implications for management

    by C. Solomon, R.E. Collis, P.W. Collins

    Postpartum haemorrhage (PPH) is a major risk factor for maternal morbidity and mortality. PPH has numerous causative factors, which makes its occurrence and severity difficult to predict. Underlying haemostatic imbalances such as consumptive and dilutional coagulopathies may develop during PPH, and can exacerbate bleeding and lead to progression to severe PPH. Monitoring coagulation status in patients with PPH may be crucial for effective haemostatic management, goal-directed therapy, and improved outcomes. However, current PPH management guidelines do not account for the altered baseline coagulation status observed in pregnant patients, and the appropriate transfusion triggers to use in PPH are unknown, due to a lack of high-quality studies specific to this area. In this review, we consider the evidence for the use of standard laboratory-based coagulation tests and point-of-care viscoelastic coagulation monitoring in PPH. Many laboratory-based tests are unsuitable for emergency use due to their long turnaround times, so have limited value for the management of PPH. Emerging evidence suggests that viscoelastic monitoring, using thrombelastography- or thromboelastometry-based tests, may be useful for rapid assessment and for guiding haemostatic therapy during PPH. However, further studies are needed to define the ranges of reference values that should be considered 'normal' in this setting. Improving awareness of the correct application and interpretation of viscoelastic coagulation monitoring techniques may be critical in realizing their emergency diagnostic potential.


  • Severe Pediatric Blunt Trauma—Successful ROTEM-Guided Hemostatic Therapy With Fibrinogen Concentrate and No Administration of Fresh Frozen Plasma or Platelets

    by Bernhard Ziegler, Christa Schimke, Peter Marchet, Birgit Stögermüller, Herbert Schöchl, Cristina Solomon

    Use of allogeneic blood products to treat pediatric trauma may be challenged, particularly in relation to safety. We report successful treatment of a child with severe abdominal and pelvic injuries with preemptive fibrinogen supplementation followed by rotational thromboelastometry (ROTEM)-guided, goal-directed hemostatic therapy. Fibrinogen concentrate was administered (total dose: 2 g), while transfusion of fresh frozen plasma and platelet concentrate was avoided. Activated partial thromboplastin time was prolonged and Quick values were low but ROTEM clotting time values remained normal, therefore, no thrombin-generating drugs were considered necessary. This case shows the potential for hemostatic treatment with coagulation factor concentrates to be applied to pediatric trauma.


  • Comparison of Whole Blood Fibrin-Based Clot Tests in Thrombelastography and Thromboelastometry

    by Cristina Solomon, Benny Sørensen, Gerald Hochleitner, Jeffry Kashuk, Marco Ranucci, Herbert Schöchl

    Fibrin-based clot firmness is measured as maximum amplitude (MA) in the functional fibrinogen (FF) thrombelastographic assay and maximum clot firmness (MCF) in the FIBTEM thromboelastometric assay. Differences between the assays/devices may be clinically significant. Our objective was to compare clot firmness parameters through standard (FF on a thrombelastography device [TEG®]; FIBTEM on a thromboelastometry device [ROTEM®]) and crossover (FF on ROTEM®; FIBTEM on TEG®) analyses. Whole-blood samples from healthy volunteers were subjected to thrombelastography and thromboelastometry analyses. Samples were investigated native and following stepwise dilution with sodium chloride solution (20%, 40%, and 60% dilution). Samples were also assessed after in vitro addition of medications (heparin, protamine, tranexamic acid) and 50% dilution with hydroxyethyl starch, gelatin, sodium chloride, and albumin. FF produced higher values than FIBTEM, regardless of the device, and TEG® produced higher values than ROTEM®, regardless of the assay. With all added medications except heparin 400 U/kg bodyweight, FF MA remained significantly higher (P < 0.05) than FIBTEM MCF, which was largely unchanged. FF MA was significantly reduced (P = 0.04) by high-dose heparin and partially restored with protamine. Fifty percent dilution with hydroxyethyl starch, albumin, and gelatin decreased FIBTEM MCF and FF MA by >50%. These results demonstrate differences when measuring fibrin-based clotting via the FF and FIBTEM assays on the TEG® and ROTEM® devices. Point-of-care targeted correction of fibrin-based clotting may be influenced by the assay and device used. For the FF assay, data are lacking.