MAMaria Elena Albermann

Maria Elena Albermann

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Maria Elena Albermann has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A SPME-GC/MS Procedure for the Determination of Fatty Acid Ethyl Esters in Hair for Confirmation of Abstinence Test Results

    by Maria Elena Albermann, Burkhard Madea, Frank Musshoff

    Fatty acid ethyl esters (FAEE), direct metabolites of ethanol, are suitable alcohol markers that can be detected in different tissues. The determination of FAEE in hair can help to evaluate social and excessive alcohol consumption. Due to the presence of FAEE in the hair of teetotalers, proving alcohol abstinence seems to be impossible. To verify these results, an solid phase micro extraction-gas chromatography/mass spectrometry procedure for the determination of the four FAEE: ethyl myristate, ethyl palmitate, ethyl oleate and ethyl stearate in hair was validated with special focus on low concentration levels. Besides very high sensitivity (limits of detection between 0.005 and 0.009 ng/mg), good results for linearity, precision and accuracy, recovery and stability were achieved. In addition, 73 hair samples with measured ethyl glucuronide (EtG) concentrations between 4 and 10 pg/mg were analyzed for FAEE. By using the following cut-offs: EtG: 7 pg/mg, FAEE: 0.2 ng/mg a satisfying matching rate of 72.6% was found. This shows that FAEE can be determined to verify borderline EtG concentrations even in the context of abstinence tests. However, the diversified influencing factors on analyte concentrations in hair, which may explain the large deviations between EtG and FAEE results observed in some cases, have to be mentioned when interpret ambiguous results.


  • Preliminary investigations on ethyl glucuronide and ethyl sulfate cutoffs for detecting alcohol consumption on the basis of an ingestion experiment and on data from withdrawal treatment

    by Maria Elena Albermann, Frank Musshoff, Elke Doberentz, Peter Heese, Markus Banger, Burkhard Madea

    Ethyl glucuronide (EtG) and ethyl sulfate (EtS) are commonly used alcohol markers for previous alcohol consumption. Nevertheless, the optimum EtG cutoff for urinary abstinence tests is still being discussed, and no cutoff has been recommended for EtS yet. The aim of this study was to verify cutoffs by investigating EtG and EtS concentrations (cEtG and cEtS) in the urine of healthy persons after drinking small, but realistic amounts of alcohol (one or two glasses of beer or white wine), and to look for the window of detection in strongly alcohol-intoxicated patients who were beginning withdrawal treatment. Very high EtG and EtS concentrations were measured in the first urine samples of patients under withdrawal treatment. However, 24 h later, concentrations decreased considerably, and c EtG < 0.5 mg/l and c EtS < 0.1 mg/l were determined in 26.7 % (4/13) and 13.3 % (2/13) of the samples, respectively. Concentrations above 0.1 mg/l (EtG) and 0.05 mg/l (EtS) were measured for 23.5 and 20.5 h after consuming 0.1 l of white wine or 0.33 l of beer, and 24 h after the experiment, 75 % (9/12) of the urine samples were tested negative for EtG and EtS using the following cutoffs: EtG 0.5 mg/l and EtS 0.1 mg/l. In half of the samples, concentrations below 0.1 mg/l (EtG) and 0.05 mg/l (EtS) were detected. Urinary cutoffs for EtG of 0.5 mg/l or higher are not suitable for testing abstinence. Even 0.1 mg/l is not effective to detect the intake of small amounts of alcohol in the context of abstinence tests. For EtS, 0.05 mg/l were found to be a potential cutoff to exclude the repeated intake of alcohol. Yet, further research is required to verify this cutoff. For a limited time period, EtG and EtS concentrations within the range of these cutoffs are also detectable after unintentional consumption of alcohol. Participants of abstinence programs have to be informed about the alcohol content of certain foods and beverages whose consumption is in conflict with strict abstinence.


  • Investigations on the influence of different grinding procedures on measured ethyl glucuronide concentrations in hair determined with an optimized and validated LC-MS/MS method

    by M. E. Albermann, F. Musshoff, L. Aengenheister, B. Madea

    Ethyl glucuronide (EtG) analysis in hair is a suitable method for the retrospective determination of previous alcohol consumption. According to the German guidelines, EtG abstinence is improbable at c(EtG) > 7 pg/mg in the proximal 3 cm of scalp hair. The chromatography of the routinely used liquid chromatography-tandem mass spectrometry procedure was optimized by replacing the stationary phase. To simplify sample preparation, two different mills were tested, and an optimized grinding process was developed. The new method was successfully validated according to the guidelines of the German Society of Toxicological and Forensic Chemistry. Despite a simple extraction procedure without any cleaning steps, a very high sensitivity (limit of detection, 1.7 pg/mg; limit of quantitation, 2.3 pg/mg) could be achieved. Competitive analysis showed significantly higher EtG concentrations in pulverized versus cut hair samples. The strong impact of sample preparation on the determined EtG concentrations suggests the introduction of a standardized sample preparation method to produce comparable results.


  • Open Access

    A High-Performance Liquid Chromatographic-Tandem Mass Spectrometric Method for the Determination of Ethyl Glucuronide and Ethyl Sulfate in Urine Validated According to Forensic Guidelines

    by M. E. Albermann, F. Musshoff, B. Madea

    Ethyl glucuronide (EtG) and ethyl sulfate (EtS) are powerful markers for alcohol intake and abuse. Several analytical procedures for the quantification of EtG and EtG in serum and urine have been developed so far. Many of the published methods show limits of detections (LODs) or limits of quantifications (LOQs) for EtG in urine within the range of 0.1 mg/L or higher. Since this is the actual cutoff value for proving abstinence in Germany, problems may occur if urine samples are highly diluted. In this paper, the validation of a highly sensitive, fast and simple LC–MS–MS for the determination of EtG and EtS in urine is described. The calibration curves for EtG and EtS is linear over the whole range (0.025–2.0 mg/L). Very low detection limits can be achieved (LOD: EtG 0.005 mg/L, EtS 0.005 mg/L; and LOQ: EtG 0.019 mg/L, EtS 0.015 mg/L). All data for selectivity, precision and accuracy, recovery, as well as for the processed sample and the freeze/thaw stability, comply with the guidelines of the German Society of Toxicological and Forensic Chemistry. Strong matrix-related effects can be compensated for by using an internal standard. Finally, the applicability of the procedure is proven by analysis of 87 human urine samples and by successful participation in interlaboratory comparison tests.


  • Comparison of ethyl glucuronide (EtG) and fatty acid ethyl esters (FAEEs) concentrations in hair for testing abstinence

    by M. E. Albermann, F. Musshoff, B. Madea

    Hair analysis is a powerful tool for retrospective drug analysis. By determining the minor ethanol metabolites ethyl glucuronide (EtG) and fatty acid ethyl esters (FAEEs) in hair, even a previous consumption of alcohol is detectable. However, previous studies showed a lack of correlation if both parameters are determined simultaneously. A further study was conducted to confirm or refute these results. One hundred and sixty hair samples were analyzed for EtG and FAEE in the context of driving ability. In 109 cases, alcohol abstinence was clearly proven and was excluded in 15 cases. In 36 cases, ambiguous results were found. Possible reasons for the deviating results are discussed. It is recommended, that in context of driving ability diagnostics the EtG result is determinant. In critical cases FAEE concentrations can be determined for checking purposes, but a negative FAEE result cannot refute a determined EtG concentration >7 pg/mg.


  • A fully validated high-performance liquid chromatography-tandem mass spectrometry method for the determination of ethyl glucuronide in hair for the proof of strict alcohol abstinence

    by Maria Elena Albermann, F. Musshoff, B. Madea

    Hair analysis has become a powerful tool for the detection of chronic and past drug consumption. For several years, it has been possible to determine even the intake of ethanol in hair samples by detecting the ethanol metabolites ethyl glucuronide or fatty acid ethyl esters. Recently, new requirements were published for the use of EtG as an abstinence test (c EtG < 7 pg/mg) as well as for heavy-drinking detection (c EtG > 30 pg/mg). In order to perform abstinence tests, a sensitive LC-MS/MS procedure has been developed and fully validated according to the guidelines of forensic toxicology. The nine-point calibration curve showed linearity over the range of concentrations from 2–1,000 pg/mg. Detection and quantification limits were 1 and 4 pg/mg respectively. The intra- and inter-day precision and accuracy were always better than 20%. The validated procedure has successfully been applied to perform abstinence tests and to analyze hair samples from persons in withdrawal treatment. Concentrations between <LOQ and 400 pg/mg were determined. In some cases, interfering peaks complicated the quantification to some extent. First results using varied chromatographic conditions showed constituting results. However, modified chromatographic conditions help substantiate critical results, especially if the determined EtG concentration is close to a cut-off value.