MRMichele Rossi

Michele Rossi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Michele Rossi has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Computational Fluid Dynamics Study to Compare Two Types of Arterial Cannulae for Cardiopulmonary Bypass

    by Vera Gramigna, Arrigo Palumbo, Michele Rossi, Gionata Fragomeni

    Thanks to recent technological and IT advances, there have been rapid developments in biomedical and health research applications of computational fluid dynamics. This is a methodology of computer-based simulation that uses numerical solutions of the governing equations to simulate real fluid flows. The aim of this study is to investigate, using a patient-specific computational fluid dynamics analysis, the hemodynamic behavior of two arterial cannulae, with two different geometries, used in clinical practice during cardiopulmonary bypass. A realistic 3D model of the aorta is extracted from a subject’s CT images using segmentation and reverse engineering techniques. The two cannulae, with similar geometry except for the distal end (straight or curved tip), are modeled and inserted at the specific position in the ascending aorta. The assumption of equal boundary conditions is adopted for the two simulations in order to analyze only the effects of a cannula’s geometry on hemodynamic behavior. Simulation results showed a greater percentage of the total output directed towards the supra-aortic vessels with the curved tip cannula (66% vs. 54%), demonstrating that the different cannula tips geometry produces specific advantages during cardiopulmonary bypass. Indeed, the straight one seems to generate a steadier flow pattern with good recirculation in the ascending aorta.


  • Open Access

    Staged Hybrid Coronary Revascularization in Acute Coronary Syndrome

    by Michele Rossi, Vincenzo Calabrese, Giovanni Tripepi, Gerlando Mallia, Frank Benedetto, Pasquale Fratto


    • 1 September 2013
      • Vol. 22  (5) , 740-2

    Resistance to secondary thrombosis of the On-X mitral prosthesis.

    by Federica Jiritano, Giuseppe F Serraino, Michele Rossi, Giuseppe Pisano, Attilio Renzulli

    A 60-year-old man underwent aortic and mitral valve replacement with mechanical On-X prostheses, plus tricuspid annuloplasty ring and maze radiofrequency ablation. Two years later, he was admitted to hospital with severe orthopnea and hemolysis. Echocardiography revealed a blocked prosthetic mitral leaflet due to interference of the preserved subvalvular apparatus. Intraoperatively, one leaflet was found to be blocked by the native mitral apparatus, but no thrombus and/or pannus was present. Although, despite an abnormal blood flow, the On-X prosthesis is resistant to secondary thrombosis, even under adverse hemodynamic conditions, interference of the valve with cardiac structures remains a possibility.

  • Open Access

    Apicoaortic conduit and cerebral perfusion in mixed aortic valve disease: a computational analysis

    by Gionata Fragomeni, Michele Rossi, Francesca Condemi, Rosario Mazzitelli, Giuseppe Filiberto Serraino, Attilio Renzulli

    The revival of the apicoaortic conduit has attracted new interest in this alternative treatment for severe aortic stenosis unsuitable for conventional valve replacement. However, doubts still exist about the perfusion of the epiaortic vessels after apicoaortic conduit implantation, especially when severe aortic stenosis is associated with aortic valve insufficiency. The aim of the study was to evaluate the perfusion of the epiaortic vessels (innominate artery, left carodit artery and left subclavian artery) in cases of mixed aortic valve disease before and after apicoaortic conduit implantation. Starting from the data of a real patient with severe aortic stenosis and mild aortic insufficiency who underwent apicoaortic conduit implantation, we created a computational model where severe aortic valve stenosis was associated with different grades of aortic insufficiency (mild, medium and moderate). A total of six combinations were analysed. In all simulations, the more severe the concomitant aortic insufficiency, the more the flow through the epiaortic vessels was diminished. After apicoaortic conduit implantation, there was an absolute augmentation of the median output in each epiaortic vessel compared with the same combination of mixed aortic valve disease before implantation. Interestingly, retrograde flow from the conduit in the descending aorta was minimal and did not contribute to the improved output of the epiaortic vessels. The computational analysis suggested a protective effect, rather than steal phenomenon, of the apicoaortic conduit towards the cerebral perfusion, even in cases of mixed aortic valve disease.


  • Open Access

    Late de Novo Aortic Regurgitation with the Jarvik 2000 Flowmaker® left ventricular assist device

    by Michele Rossi, Giuseppe Filiberto Serraino, Federica Jiritano, Attilio Renzulli

    Introduction: There is a worldwide trend towards a more liberal use of ventricular assist devices (VADs) as a definitive treatment for patients in end-stage heart failure. This has also led to a new set of complications related to the prolonged interaction between the native heart and the device. Methods: We report a case of, late, de novo aortic regurgitation (AR), leading to acute pulmonary edema in a 56-year-old man, 20 months after the implantation of a left ventricular assist device (LVAD), the Jarvik 2000 Flowmaker®, as destination therapy for end-stage heart failure. Results: The Jarvik 2000 was working well at check up at level 3 of assistance, i.e. generating a flow between 3–5 l/min at 10,000 rpm. The only new finding was a moderate, de novo, AR at trans-thoracic echocardiogram (TTE). The patient was assisted in intensive care with inotropic and diuretic support and made a good recovery. He remains under close follow up in NYHA class II with the same level of mechanical assistance and a more intensive diuretic therapy. Conclusions: This case shows how dramatic the onset of de novo AR in patients with LVAD can be. The AR occurred despite the presence of the ILS (intermittent low speed) that allows the opening of the native aortic valve for 8 seconds every 64 and should, theoretically, preserve the native aortic valve. To our knowledge, this is the first report of de novo AR in a patient with the Jarvik 2000 axial flow device.


  • Late de novo aortic regurgitation with the Jarvik 2000 Flowmaker® left ventricular assist device

    by Michele Rossi, Giuseppe Filiberto Serraino, Federica Jiritano, Attilio Renzulli

    There is a worldwide trend towards a more liberal use of ventricular assist devices (VADs) as a definitive treatment for patients in end-stage heart failure. This has also led to a new set of complications related to the prolonged interaction between the native heart and the device.


  • Open Access

    Device-Related Endocarditis and Infected Leads Extraction: The Dark Side of The Moon

    by Michele Rossi, Giuseppe Musolino, Giuseppe Filiberto, Attilio Renzulli

    Device-Related Endocarditis and Infected Leads Extraction: The Dark Side of The Moon | InTechOpen, Published on: 2012-08-17. Authors: Michele Rossi, Giuseppe Musolino, Giuseppe Filiberto Serraino, et

  • Open Access

    What is the optimal anticoagulation in patients with a left ventricular assist device?

    by Michele Rossi, Giuseppe Filiberto Serraino, Federica Jiritano, Attilio Renzulli

    A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was whether there is an optimal antithrombotic management for patients supported with axial-flow left ventricular assist devices (LVADs). Altogether, more than 758 papers were found using the reported search, of which 17 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. These included seven prospective and three retrospective cohort studies with a total of 538 patients with axial-flow left ventricular assist device (LVAD) (HeartMate II, Jarvik 2000, INCOR, Thoratec assist device) implanted across the world as destination therapy or bridge to transplantation. We conclude that there is a substantial alteration of the prothrombotic profile in patients with axial-flow LVADs. These abnormalities appeared to be reversible with the removal of the device and are likely to be responsible for the high incidence of non-surgical bleeding episodes reported. Warfarin seems to offer a lower thromboembolic risk compared with unfractioned heparin or low molecular weight heparin. There are reports that suggest that managing axial-flow LVAD without anticoagulation, after major bleeding complications, is possible but in all probability, these papers are subject to publication bias as poor outcomes are unlikely to have been reported. All patients with axial-flow LVAD, showed severely impaired platelet function at point of care tests. The use of warfarin (INR target 2.5), in association with aspirin at 100 mg/day, or with point-of-care tests titrated antiplatelet therapy to inhibit 70%, seems to have the best bleeding-thrombosis, and in many cases a very small dose of aspirin of 25 mg twice a day and a dose of clopidogrel of 35 mg/day, were sufficient to achieve a reduction of the maximum aggregation to less than 30%. Finally, we would like to emphasize that such recommendations are addressed only to patients with axial-flow LVAD.


  • Open Access

    Competitive flow between a vein and an arterial graft at transit-time flow measurement

    by Michele Rossi, Federica Jiritano, Emanuele Malta, Attilio Renzulli

    We report the intraoperative finding, at a transit-time flow measurement, of competitive flow between a venous and an arterial graft in a 72-year old woman who underwent uncomplicated coronary artery bypass grafting × 3. The blood flow in the left internal mammary artery (LIMA) improved only after temporary occlusion of the saphenous vein graft (SVG) anastomosed to the first diagonal (D1), demonstrating the presence of competitive flow from the SVG-D1 anastomosis into the LIMA–left anterior descending coronary artery (LAD) system. Interestingly the two target vessels suffered from separate critical lesions. The patient's haemodynamics remained stable throughout and no further action was taken. Her recovery was uneventful and the patient was discharged home on postoperative day 6. This case raised questions about the cost benefit of grafting a diagonal target even when it appeared to be disconnected from the LAD on a coronary angiogram.