Yoshiyuki Takami
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Yoshiyuki Takami has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Kazuyoshi Tajima
Department of Cardiovascular Surgery, Nagoya Daini Red Cross Hospital, Nagoya, Japan
10 shared publicationsKei Fujii
Department of Cardiovascular Surgery, Nagoya Daini Red Cross Hospital, Nagoya, Japan
9 shared publicationsYoshimasa Sakai
Department of Cardiovascular Surgery, Nagoya Daini Red Cross Hospital, Nagoya, Japan
9 shared publicationsHisaaki Munakata
Department of Cardiovascular Surgery, Nagoya Daini Red Cross Hospital, Nagoya, Japan
7 shared publicationsMakoto Hibino
Department of Cardiovascular Surgery, Nagoya Daini Red Cross Hospital, Nagoya, Japan
7 shared publicationsHiroshi Masumoto
6 shared publications
Latest Publications
- 1 February 2014
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 147 (2) , 619-624
Effects of the side of arteriovenous fistula on outcomes after coronary artery bypass surgery in hemodialysis-dependent patients
- 1 February 2014
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 147 (2) , 619-624
Effects of the side of arteriovenous fistula on outcomes after coronary artery bypass surgery in hemodialysis-dependent patients
- 1 January 2014
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 147 (1) , 259-263
Clinical validation of coronary artery flow through an intracoronary shunt during off-pump coronary artery bypass grafting
- 1 January 2014
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 147 (1) , 259-263
Clinical validation of coronary artery flow through an intracoronary shunt during off-pump coronary artery bypass grafting
- 1 December 2012
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 94 (6) , 1940-1945
Predictors for Early and Late Outcomes After Coronary Artery Bypass Grafting in Hemodialysis Patients
- 1 December 2012
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 94 (6) , 1940-1945
Predictors for Early and Late Outcomes After Coronary Artery Bypass Grafting in Hemodialysis Patients
- Open Access
- 23 April 2012
- Published by Wiley in Clinical Cardiology
- Vol. 35 (8) , 500-504
Can We Predict the Site of Entry Tear by Computed Tomography in Patients With Acute Type A Aortic Dissection?
Background: In patients with acute type A aortic dissection (AAD), localization of the primary entry tear to be excluded is of major importance for intervention.Hypothesis: There are reliable indirect computed tomography (CT) findings to predict the entry site.Methods: In 83 patients with type A AAD whose primary entry tears were identified surgically between 2003 and 2009, we retrospectively examined the diagnostic CT scans regarding pericardial effusion, the largest short‐axial diameter of the aorta, widths of true and false lumens, and false lumen thrombosis at 6 levels of thoracic aorta from the aortic root to the descending aorta.Results: The primary entry sites identified intraoperatively were proximal ascending in 21 patients, middle ascending in 21, distal ascending in 21, arch in 17, and descending or unknown in 16. The multivariate logistic analysis revealed that pericardial effusion (odds ratio [OR]: 2.2, 95% confidence interval [CI]: 1.2–3.4, P < 0.001) and dilated ascending aorta (OR: 1.6, 95% CI: 1.1–2.4, P = 0.012) were the significant CT findings to predict the entry tear in the ascending aorta. It also revealed that the significant CT finding to predict the entry tear distal to the aortic arch was nonthrombosed false lumen in the descending aorta (OR: 1.2, 95% CI: 1.1–2.1, P = 0.048).Conclusions: We can predict the primary entry site by the preoperative CT findings in patients with type A AAD, considering pericardial effusion, aortic diameter, widths of true and false lumens, and false lumen thrombosis at different anatomic levels. Clin. Cardiol. 2012 DOI: 10.1002/clc.21991The authors have no funding, financial relationships, or conflicts of interest to disclose.
- 23 April 2012
- Published by Wiley in Clinical Cardiology
- Vol. 35 (8) , 500-504
Open AccessCan We Predict the Site of Entry Tear by Computed Tomography in Patients With Acute Type A Aortic Dissection?
Background: In patients with acute type A aortic dissection (AAD), localization of the primary entry tear to be excluded is of major importance for intervention.Hypothesis: There are reliable indirect computed tomography (CT) findings to predict the entry site.Methods: In 83 patients with type A AAD whose primary entry tears were identified surgically between 2003 and 2009, we retrospectively examined the diagnostic CT scans regarding pericardial effusion, the largest short‐axial diameter of the aorta, widths of true and false lumens, and false lumen thrombosis at 6 levels of thoracic aorta from the aortic root to the descending aorta.Results: The primary entry sites identified intraoperatively were proximal ascending in 21 patients, middle ascending in 21, distal ascending in 21, arch in 17, and descending or unknown in 16. The multivariate logistic analysis revealed that pericardial effusion (odds ratio [OR]: 2.2, 95% confidence interval [CI]: 1.2–3.4, P < 0.001) and dilated ascending aorta (OR: 1.6, 95% CI: 1.1–2.4, P = 0.012) were the significant CT findings to predict the entry tear in the ascending aorta. It also revealed that the significant CT finding to predict the entry tear distal to the aortic arch was nonthrombosed false lumen in the descending aorta (OR: 1.2, 95% CI: 1.1–2.1, P = 0.048).Conclusions: We can predict the primary entry site by the preoperative CT findings in patients with type A AAD, considering pericardial effusion, aortic diameter, widths of true and false lumens, and false lumen thrombosis at different anatomic levels. Clin. Cardiol. 2012 DOI: 10.1002/clc.21991The authors have no funding, financial relationships, or conflicts of interest to disclose.
- Open Access
- 17 February 2012
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 14 (5) , 529-531
Long-term size follow-up of knitted Dacron grafts (Gelseal ) used in the ascending aorta
There is limited information about the size change of a knitted Dacron graft (Gelseal™) used in the thoracic aorta. We evaluated the diameters of the Gelseal™ grafts at a long-term follow-up for 3.7 ± 1.3 years (1–5.9 years; median, 4.0 years), which were used for replacement of the ascending aorta in 59 patients with acute aortic dissection. The early and late dilatation rates (LDRs) of the prosthetic grafts were calculated retrospectively based on the graft diameter at the level equivalent to the ascending aorta on the pre-discharge computed tomography (CT) scans and follow-up CT scans performed every year after surgery. Immediately after surgery (15 ± 7 days), the early dilatation of the Gelseal™ grafts was 26.0 ± 6.0% with significant correlations with the number of post-operative days (R = 0.500, P = 0.003). At the follow-up for 3.7 ± 1.3 years, the LDR was 10.5 ± 6.6%, which was also significantly correlated with the number of the post-operative years (R = 0.608, P = 0.001). Linear regression analysis indicated that the annual dilatation rate was ∼3.23%. During the follow-up, we have experienced no redo surgery due to graft fracture or false aneurysm formation at the anastomosis sites associated with the graft dilatation. In conclusion, the Gelseal™ graft used in the ascending aorta demonstrates a small but continuous increase in the diameter, up to 5 years after implantation, without any adverse events.
- 17 February 2012
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 14 (5) , 529-531
Open AccessLong-term size follow-up of knitted Dacron grafts (Gelseal ) used in the ascending aorta
There is limited information about the size change of a knitted Dacron graft (Gelseal™) used in the thoracic aorta. We evaluated the diameters of the Gelseal™ grafts at a long-term follow-up for 3.7 ± 1.3 years (1–5.9 years; median, 4.0 years), which were used for replacement of the ascending aorta in 59 patients with acute aortic dissection. The early and late dilatation rates (LDRs) of the prosthetic grafts were calculated retrospectively based on the graft diameter at the level equivalent to the ascending aorta on the pre-discharge computed tomography (CT) scans and follow-up CT scans performed every year after surgery. Immediately after surgery (15 ± 7 days), the early dilatation of the Gelseal™ grafts was 26.0 ± 6.0% with significant correlations with the number of post-operative days (R = 0.500, P = 0.003). At the follow-up for 3.7 ± 1.3 years, the LDR was 10.5 ± 6.6%, which was also significantly correlated with the number of the post-operative years (R = 0.608, P = 0.001). Linear regression analysis indicated that the annual dilatation rate was ∼3.23%. During the follow-up, we have experienced no redo surgery due to graft fracture or false aneurysm formation at the anastomosis sites associated with the graft dilatation. In conclusion, the Gelseal™ graft used in the ascending aorta demonstrates a small but continuous increase in the diameter, up to 5 years after implantation, without any adverse events.
- Open Access
- 1 January 2010
- Published by The Japanese Society for Cardiovascular Surgery in Japanese Journal of Cardiovascular Surgery
- Vol. 39 (3) , 105-110
Strategies, Risks, and Outcomes in Cardiac and Aortic Reoperations
- 1 January 2010
- Published by The Japanese Society for Cardiovascular Surgery in Japanese Journal of Cardiovascular Surgery
- Vol. 39 (3) , 105-110
Open AccessStrategies, Risks, and Outcomes in Cardiac and Aortic Reoperations
- 30 November 2009
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 88 (5) , 1515-1519
Simplified Management of Hemodialysis-Dependent Patients Undergoing Cardiac Surgery
- 30 November 2009
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 88 (5) , 1515-1519
Simplified Management of Hemodialysis-Dependent Patients Undergoing Cardiac Surgery
- 30 September 2009
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 138 (3) , 669-673
Transit-time flow characteristics of in situ right gastroepiploic arterial grafts in coronary artery bypass grafting
- 30 September 2009
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 138 (3) , 669-673
Transit-time flow characteristics of in situ right gastroepiploic arterial grafts in coronary artery bypass grafting
- 1 April 2009
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 137 (4) , 875-880
Safer aortic crossclamping during short-term moderate hypothermic circulatory arrest for cardiac surgery in patients with a bad ascending aorta
- 1 April 2009
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 137 (4) , 875-880
Safer aortic crossclamping during short-term moderate hypothermic circulatory arrest for cardiac surgery in patients with a bad ascending aorta
- 30 September 2008
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 86 (3) , 823-827
Effects of Intra-Aortic Balloon Pumping on Graft Flow in Coronary Surgery: An Intraoperative Transit-Time Flowmetric Study
- 30 September 2008
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 86 (3) , 823-827
Effects of Intra-Aortic Balloon Pumping on Graft Flow in Coronary Surgery: An Intraoperative Transit-Time Flowmetric Study