SWStephen G. Worthley

Stephen G. Worthley

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Stephen G. Worthley has a total of 133 co-authors. Here are the top co-authors by number of shared publications:

  • Matthew I. Worthley

    Cardiovascular Research Centre, Royal Adelaide Hospital, South Australia, Australia; Department of Medicine, University of Adelaide, South Australia, Australia

    10 shared publications
  • Benjamin K Dundon

    Royal Adelaide Hospital, North Terrace, Adelaide, South Australia, Australia

    7 shared publications
  • James D. Richardson

    Cardiovascular Research Centre, Royal Adelaide Hospital, South Australia, Australia; Department of Medicine, University of Adelaide, South Australia, Australia; Centre for Stem Cell Research, Robinson Institute, School of Medical Sciences, University of Adelaide, South Australia, Australia

    7 shared publications
  • Prashanthan Sanders

    Centre for Heart Rhythm Disorders, Adelaide University and Royal Adelaide Hospital, Adelaide, Australia

    7 shared publications
  • Angela G. Bertaso

    Cardiovascular Research Centre, Royal Adelaide Hospital, South Australia, Australia; Department of Medicine, University of Adelaide, South Australia, Australia

    6 shared publications
  • Dennis T. L. Wong

    Cardiovascular Research Centre, Royal Adelaide Hospital & Discipline of Medicine, University of Adelaide, Adelaide, Australia

    5 shared publications

Latest Publications

  • Open Access

    Paclitaxel-eluting balloon and everolimus-eluting stent for provisional stenting of coronary bifurcations: 12-month results of the multicenter BIOLUX-I study

    by Stephen Worthley, Randall Hendriks, Matthew Worthley, Alan Whelan, Darren L. Walters, Robert Whitbourn, Ian Meredith


  • Incremental benefits of repeated mesenchymal stromal cell administration compared with solitary intervention after myocardial infarction

    by James D. Richardson, Peter J. Psaltis, Lachlan Frost, Sharon Paton, Angelo Carbone, Angela G. Bertaso, Adam J. Nelson, Dennis T.L. Wong, Matthew I. Worthley, Stan Gronthos, et al.


    • 1 February 2014
      • Vol. 62  (1) , 99-104

    Percutaneous renal denervation and the second generation EnligHTN System.

    by R G Chokka, S Delacroix, P J Psaltis, N S Anavekar, S G Worthley

    Hypertension remains a major public health burden despite the plethora of therapeutic agents available for this disorder, compelling innovation of alternate therapies including interventional approaches where necessary. The kidney is a major player in the pathophysiology of this disease with increased sympathetic activity being the key factor in the initiation and maintenance of drug resistant hypertension in many patients. Thus renal denervation targeted at decreasing sympathetic drive is becoming the apparent choice in carefully selected patients with resistant hypertension who have exhausted all medical options. The Symplicity and EnligHTN trials using first and second generation catheters respectively have demonstrated that renal sympathetic denervation results in significant blood pressure reduction. The initial renal denervation catheter used in the Symplicity trial was a single electrode system. Refinement of this process has led to the EnligHTN catheter's design. This is a multielectrode self-expanding nitinol basket that allows the positioning of the thermal injury pattern to be pre-specified and in theory lead to better positioning of the lesions. We present a review of the premise behind renal artery denervation, discuss the data and early technologies focusing on the characteristics and utility of the first multielectrode renal denervation device, the EnligHTN renal denervation catheter.


  • Pericardial fat predicts reverse remodeling of the left atrium following atrial fibrillation ablation

    by C. X. Wong, R. Mahajan, R. Pathak, D. H. Lau, H. S. Abed, K. C. Roberts-Thomson, W. P. Abhayaratna, S. G. Worthley, J. B. Selvanayagam, P. Sanders

  • Sympathetic renal artery denervation with a multi-electrode catheter in patients with drug-resistant hypertension: 12 month results of the EnligHTN I multi-center trial

    by C. Tsioufis, S. G. Worthley, M. Worthley, D. Chew, A. Sinhal, I. Meredith, Y. Malaiapan, V. Papademetriou

    Purpose: Single-tip electrode radiofrequency ablation catheters were used to achieve sympathetic fiber interruption through the renal artery wall. We investigated the safety and efficacy of a multi-electrode catheter ablation system (EnligHTN) developed by St. Jude Medical. Method: The EnligHTNrenal denervation system has 4electrodes attached on a basket mounted at the tip of the catheter. The electrodes are sequentially activated to achieve a predictable lesion pattern. TheEnligHTN-I first-in-human study was designed to assess the safety and efficacy of this multi-electrode ablation system in patients with drug-resistant hypertension. A total of 46 pts (average age 60±10yrs, 33% female, taking an average of 4.1±0.6 medications) were enrolled.Bilateral renal nerve ablation was performed using a percutaneous femoral approach. On average 7.7±0.8 lesions were created in the right renal artery and 7.4±1.4 in the left renal artery. Results: Mean baseline office BP was 176/96 mmHg and mean 24hambulatory BPwas150/83 mmHg. Average significant reductions (mmHg) of office BP (pConclusions: We conclude that data demonstrates that the EnligHTN ablation system continues to be safe and effective in the treatment of patients with drug-resistant hypertension.

  • Open Access

    Safety and efficacy of a multi-electrode renal sympathetic denervation system in resistant hypertension: the EnligHTN I trial

    by Stephen G. Worthley, Costas P. Tsioufis, Matthew I. Worthley, Ajay Sinhal, Derek P. Chew, Ian T. Meredith, Yuvi Malaiapan, Vasilios Papademetriou

    Catheter-based renal artery sympathetic denervation has emerged as a novel therapy for treatment of patients with drug-resistant hypertension. Initial studies were performed using a single electrode radiofrequency catheter, but recent advances in catheter design have allowed the development of multi-electrode systems that can deliver lesions with a pre-determined pattern. This study was designed to evaluate the safety and efficacy of the EnligHTN™ multi-electrode system. We conducted the first-in-human, prospective, multi-centre, non-randomized study in 46 patients (67% male, mean age 60 years, and mean baseline office blood pressure 176/96 mmHg) with drug-resistant hypertension. The primary efficacy objective was change in office blood pressure from baseline to 6 months. Safety measures included all adverse events with a focus on the renal artery and other vascular complications and changes in renal function. Renal artery denervation, using the EnligHTN™ system significantly reduced the office blood pressure from baseline to 1, 3, and 6 months by −28/10, −27/10 and −26/10 mmHg, respectively (P < 0.0001). No acute renal artery injury or other serious vascular complications occurred. Small, non-clinically relevant, changes in average estimated glomerular filtration rate were reported from baseline (87 ± 19 mL/min/1.73 m2) to 6 months post-procedure (82 ± 20 mL/min/1.73 m2). Renal sympathetic denervation, using the EnligHTN™ multi-electrode catheter results in a rapid and significant office blood pressure reduction that was sustained through 6 months. The EnligHTN™ system delivers a promising therapy for the treatment of drug-resistant hypertension.


    • 1 April 2013
      • Vol. 25  (4) , 190-195

    Relationship of Aortic Annular Eccentricity and Paravalvular Regurgitation Post Transcatheter Aortic Valve Implantation With CoreValve

    by Dennis T. L. Wong, Angela G. Bertaso, Gary Y. H. Liew, Viji S. Thomson, Michael S. Cunnington, James D. Richardson, Robert Gooley, Siobhan Lockwood, Ian T. Meredith, Matthew I. Worthley, et al.

    Background. Significant paravalvular aortic regurgitation (PAR) after transcatheter aortic valve implantation (TAVI) is associated with negative clinical consequences. We hypothesize that increased eccentricity of the aortic annulus is associated with greater PAR. Methods. Patients with severe aortic stenosis underwent multidetector computed tomography (MDCT) before successful TAVI with the Medtronic CoreValve bioprosthesis. The smallest (D-min) and largest (D-max) orthogonal diameters in the basal ring of the aortic annulus were determined. We defined circularity of aortic annulus using the eccentricity index (1 - D-min/D-max). The primary endpoint was early occurrence of significant PAR, defined as > grade II PAR by postprocedural aortography. Results. Eighty-four patients, mean age 83 +/- 4 years with a mean aortic valve area of 0.7 +/- 0.2 cm(2) were included. Twenty patients had postprocedural PAR > grade II. Using a receiver operating characteristic (ROC) analysis, eccentricity index correlated with significant PAR (AUG = 0.834; P=.034). A retrospectively determined eccentricity index cut-off of >0.25 was related to significant PAR with a sensitivity of 80%, specificity of 86%, and negative predictive value of 95% (P<.001). On univariate logistic regression, eccentricity index of >0.25 (P<.001) and device implantation depth (P=.015) correlated with significant PAR, while other parameters such as annular calcification and cover index did not. On multivariate analysis including only parameters with P<.1 on univariate analysis, eccentricity index >0.25 was the sole independent predictor of significant PAR. Conclusion. Eccentricity index is related to significant PAR after TAVI with Medtronic CoreValve. Further larger studies are required to determine the utility of this novel index in screening suitable patients for this procedure. J INVASIVE CARDIOL 2013;25(4):190-195


  • An Ideal Image: Effusive Constrictive Pericarditis

    by Shah M. Azarisman, James D. Richardson, S.K. Chua, Michael S. Cunningham, Karen S. Teo, Stephen G. Worthley


  • Electro-mechanical characteristics of myocardial infarction border zones and ventricular arrhythmic risk: novel insights from grid-tagged cardiac magnetic resonance imaging

    by Dennis T. L. Wong, Michael J. Weightman, Mathias Baumert, Hussam Tayeb, James D. Richardson, Rishi Puri, Angela G. Bertaso, Kurt C. Roberts-Thomson, Prashanthan Sanders, Matthew I. Worthley, et al.

    To investigate whether grid-tag myocardial strain evaluation can characterise ‘border-zone’ peri-infarct region and identify patients at risk of ventricular arrhythmia as the peri-infarct myocardial zone may represent an important contributor to ventricular arrhythmia following ST-segment elevation myocardial infarction (STEMI).


  • The role of cardiac magnetic resonance imaging following acute myocardial infarction

    by Dennis T. L. Wong, James D. Richardson, Rishi Puri, Adam J. Nelson, Angela G. Bertaso, Karen S. L. Teo, Matthew I. Worthley, Stephen G. Worthley