Yuko Kinashi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Yuko Kinashi has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
Koji Ono
Kyoto University, Research Reactor Institute, Osaka 590-0494, Japan
8 shared publications- Koji Ono
Research Reactor Institute, Kyoto University, Osaka, Japan
8 shared publications - Minoru Suzuki
Institute for Integrated Radiation and Nuclear Science, Kyoto University, 2 Asashiro-Nishi, Kumatori-cho, Sennan-gun, Osaka 590-0494, Japan
7 shared publications Shinichiro Masunaga
Kyoto University Research Reactor Institute, Asashironishi 2-1010, Kumatori-cho, Sennan-gun, Osaka 590-0494, Japan
7 shared publicationsSentaro Takahashi
Institute for Integrated Radiation and Nuclear Science Kyoto University, Kumatori-cho, Sennan-gun, Osaka, 590-0494, Japan
6 shared publications- Kenji Nagata
Department of Radiation Oncology, Ishikiriseiki Hospital, Higashiosaka, Japan
5 shared publications
Latest Publications
- 1 September 2020
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 163, 109204
The combined effect of neutron irradiation and temozolomide on glioblastoma cell lines with different MGMT and P53 status
- 1 September 2020
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 163, 109204
The combined effect of neutron irradiation and temozolomide on glioblastoma cell lines with different MGMT and P53 status
- 1 April 2017
- Published by International Institute of Anticancer Research in Anticancer Research
- Vol. 37 (4) , 1681-1685
DNA Double-strand Breaks Induced byFractionated Neutron Beam Irradiation for Boron Neutron Capture Therapy
Aim: To use the 53BP1 foci assay to detect DNA double-strand breaks induced by fractionated neutron beam irradiation of normal cells. Materials and Methods: The Kyoto University Research Reactor heavy-water facility and gamma-ray irradiation system were used as experimental radiation sources. After fixation of Chinese Hamster Ovary cells with 3.6% formalin, immunofluorescence staining was performed. Number and size of foci were analyzed using ImageJ software. Results: Fractionated neutron irradiation induced 25% fewer 53BP1 foci than single irradiation at the same dose. By contrast, gamma irradiation induced 30% fewer 53BP1 foci than single irradiation at the same dose. Fractionated neutron irradiation induced larger foci than gamma irradiation, raising the possibility that persistent unrepaired DNA damage was amplified due to the high linear energy transfer component in the neutron beam. Conclusion: Unrepaired cluster DNA damage was more prevalent after fractionated neutron irradiation than after gamma irradiation.
- 1 April 2017
- Published by International Institute of Anticancer Research in Anticancer Research
- Vol. 37 (4) , 1681-1685
DNA Double-strand Breaks Induced byFractionated Neutron Beam Irradiation for Boron Neutron Capture Therapy
Aim: To use the 53BP1 foci assay to detect DNA double-strand breaks induced by fractionated neutron beam irradiation of normal cells. Materials and Methods: The Kyoto University Research Reactor heavy-water facility and gamma-ray irradiation system were used as experimental radiation sources. After fixation of Chinese Hamster Ovary cells with 3.6% formalin, immunofluorescence staining was performed. Number and size of foci were analyzed using ImageJ software. Results: Fractionated neutron irradiation induced 25% fewer 53BP1 foci than single irradiation at the same dose. By contrast, gamma irradiation induced 30% fewer 53BP1 foci than single irradiation at the same dose. Fractionated neutron irradiation induced larger foci than gamma irradiation, raising the possibility that persistent unrepaired DNA damage was amplified due to the high linear energy transfer component in the neutron beam. Conclusion: Unrepaired cluster DNA damage was more prevalent after fractionated neutron irradiation than after gamma irradiation.
- 23 October 2015
- Published by Wiley in Medical Physics
- Vol. 42 (11) , 6651-6657
Development of a dual phantom technique for measuring the fast neutron component of dose in boron neutron capture therapy
Purpose: Research and development of various accelerator-based irradiation systems for boron neutron capture therapy (BNCT) is underway throughout the world. Many of these systems are nearing or have started clinical trials. Before the start of treatment with BNCT, the relative biological effectiveness (RBE) for the fast neutrons (over 10 keV) incident to the irradiation field must be estimated. Measurements of RBE are typically performed by biological experiments with a phantom. Although the dose deposition due to secondary gamma rays is dominant, the relative contributions of thermal neutrons (below 0.5 eV) and fast neutrons are virtually equivalent under typical irradiation conditions in a water and/or acrylic phantom. Uniform contributions to the dose deposited from thermal and fast neutrons are based in part on relatively inaccurate dose information for fast neutrons. This study sought to improve the accuracy in the dose estimation for fast neutrons by using two phantoms made of different materials in which the dose components can be separated according to differences in the interaction cross sections. The development of a “dual phantom technique” for measuring the fast neutron component of dose is reported. Methods: One phantom was filled with pure water. The other phantom was filled with a water solution of lithium hydroxide (LiOH) capitalizing on the absorbing characteristics of lithium-6 (Li-6) for thermal neutrons. Monte Carlo simulations were used to determine the ideal mixing ratio of Li-6 in LiOH solution. Changes in the depth dose distributions for each respective dose component along the central beam axis were used to assess the LiOH concentration at the 0, 0.001, 0.01, 0.1, 1, and 10 wt. % levels. Simulations were also performed with the phantom filled with 10 wt. % 6LiOH solution for 95%-enriched Li-6. A phantom was constructed containing 10 wt. % 6LiOH solution based on the simulation results. Experimental characterization of the depth dose distributions of the neutron and gamma-ray components along the central axis was performed at Heavy Water Neutron Irradiation Facility installed at Kyoto University Reactor using activation foils and thermoluminescent dosimeters, respectively. Results: Simulation results demonstrated that the absorbing effect for thermal neutrons occurred when the LiOH concentration was over 1%. The most effective Li-6 concentration was determined to be enriched 6LiOH with a solubility approaching its upper limit. Experiments confirmed that the thermal neutron flux and secondary gamma-ray dose rate decreased substantially; however, the fast neutron flux and primary gamma-ray dose rate were hardly affected in the 10%-6LiOH phantom. It was confirmed that the dose contribution of fast neutrons is improved from approximately 10% in the pure water phantom to approximately 50% in the 10%-6LiOH phantom. Conclusions: The dual phantom technique using the combination of a pure water phantom and a 10%-6LiOH phantom developed in this work provides an effective method for dose estimation of the fast neutron component in BNCT. Improvement in the accuracy achieved with the proposed technique results in improved RBE estimation for biological experiments and clinical practice.
- 23 October 2015
- Published by Wiley in Medical Physics
- Vol. 42 (11) , 6651-6657
Development of a dual phantom technique for measuring the fast neutron component of dose in boron neutron capture therapy
Purpose: Research and development of various accelerator-based irradiation systems for boron neutron capture therapy (BNCT) is underway throughout the world. Many of these systems are nearing or have started clinical trials. Before the start of treatment with BNCT, the relative biological effectiveness (RBE) for the fast neutrons (over 10 keV) incident to the irradiation field must be estimated. Measurements of RBE are typically performed by biological experiments with a phantom. Although the dose deposition due to secondary gamma rays is dominant, the relative contributions of thermal neutrons (below 0.5 eV) and fast neutrons are virtually equivalent under typical irradiation conditions in a water and/or acrylic phantom. Uniform contributions to the dose deposited from thermal and fast neutrons are based in part on relatively inaccurate dose information for fast neutrons. This study sought to improve the accuracy in the dose estimation for fast neutrons by using two phantoms made of different materials in which the dose components can be separated according to differences in the interaction cross sections. The development of a “dual phantom technique” for measuring the fast neutron component of dose is reported. Methods: One phantom was filled with pure water. The other phantom was filled with a water solution of lithium hydroxide (LiOH) capitalizing on the absorbing characteristics of lithium-6 (Li-6) for thermal neutrons. Monte Carlo simulations were used to determine the ideal mixing ratio of Li-6 in LiOH solution. Changes in the depth dose distributions for each respective dose component along the central beam axis were used to assess the LiOH concentration at the 0, 0.001, 0.01, 0.1, 1, and 10 wt. % levels. Simulations were also performed with the phantom filled with 10 wt. % 6LiOH solution for 95%-enriched Li-6. A phantom was constructed containing 10 wt. % 6LiOH solution based on the simulation results. Experimental characterization of the depth dose distributions of the neutron and gamma-ray components along the central axis was performed at Heavy Water Neutron Irradiation Facility installed at Kyoto University Reactor using activation foils and thermoluminescent dosimeters, respectively. Results: Simulation results demonstrated that the absorbing effect for thermal neutrons occurred when the LiOH concentration was over 1%. The most effective Li-6 concentration was determined to be enriched 6LiOH with a solubility approaching its upper limit. Experiments confirmed that the thermal neutron flux and secondary gamma-ray dose rate decreased substantially; however, the fast neutron flux and primary gamma-ray dose rate were hardly affected in the 10%-6LiOH phantom. It was confirmed that the dose contribution of fast neutrons is improved from approximately 10% in the pure water phantom to approximately 50% in the 10%-6LiOH phantom. Conclusions: The dual phantom technique using the combination of a pure water phantom and a 10%-6LiOH phantom developed in this work provides an effective method for dose estimation of the fast neutron component in BNCT. Improvement in the accuracy achieved with the proposed technique results in improved RBE estimation for biological experiments and clinical practice.
- 1 January 2015
- Vol. 35 (1) , 169-74
Influence of p53 status on the effects of boron neutron capture therapy in glioblastoma.
The tumor suppressor gene p53 is mutated in glioblastoma. We studied the relationship between the p53 gene and the biological effects of boron neutron capture therapy (BNCT). The human glioblastoma cells; A172, expressing wild-type p53, and T98G, with mutant p53, were irradiated by the Kyoto University Research Reactor (KUR). The biological effects after neutron irradiation were evaluated by the cell killing effect, 53BP1 foci assay and apoptosis induction. The survival-fraction data revealed that A172 was more radiosensitive than T98G, but the difference was reduced when boronophenylalanine (BPA) was present. Both cell lines exhibited similar numbers of foci, suggesting that the initial levels of DNA damage did not depend on p53 function. Detection of apoptosis revealed a lower rate of apoptosis in the T98G. BNCT causes cell death in glioblastoma cells, regardless of p53 mutation status. In T98G cells, cell killing and apoptosis occurred effectively following BNCT.
- 1 January 2015
- Vol. 35 (1) , 169-74
Influence of p53 status on the effects of boron neutron capture therapy in glioblastoma.
The tumor suppressor gene p53 is mutated in glioblastoma. We studied the relationship between the p53 gene and the biological effects of boron neutron capture therapy (BNCT). The human glioblastoma cells; A172, expressing wild-type p53, and T98G, with mutant p53, were irradiated by the Kyoto University Research Reactor (KUR). The biological effects after neutron irradiation were evaluated by the cell killing effect, 53BP1 foci assay and apoptosis induction. The survival-fraction data revealed that A172 was more radiosensitive than T98G, but the difference was reduced when boronophenylalanine (BPA) was present. Both cell lines exhibited similar numbers of foci, suggesting that the initial levels of DNA damage did not depend on p53 function. Detection of apoptosis revealed a lower rate of apoptosis in the T98G. BNCT causes cell death in glioblastoma cells, regardless of p53 mutation status. In T98G cells, cell killing and apoptosis occurred effectively following BNCT.
- 1 August 2014
- Vol. 34 (8) , 4503-7
An NDT study of a boron tracedrug UTX-51 for glycated BSA as an AGE model.
Conventional therapies for diseases that are associated with protein aggregation typically prevent rather than clear protein aggregates. We have proposed neutron dynamic therapy (NDT) as a physical clearance therapy for protein aggregates. Advanced glycation end-products (AGEs), which are aggregated proteins, have been implicated in diabetes, Alzheimer's, and heart disease. Herein, we report the use of the boron tracedrug UTX-51, under thermal neutron irradiation, as an NDT for the targeted clearance of glycated bovine serum albumin (Gly-BSA), a model of AGEs. Sodium dodecyl sulfate-polyacrylamide gel electrophoresis was performed to detect Gly-BSA decomposition by thermal neutron irradiation treated with UTX-51. The combination of UTX-51 with neutron irradiation showed a decrease in band intensity of Gly-BSA. We present our NDT strategy, which has been used for the targeted clearance of Gly-BSA, suggesting that NDT with boron tracedrugs can be used for the treatment of AGEs-related disease.
- 1 August 2014
- Vol. 34 (8) , 4503-7
An NDT study of a boron tracedrug UTX-51 for glycated BSA as an AGE model.
Conventional therapies for diseases that are associated with protein aggregation typically prevent rather than clear protein aggregates. We have proposed neutron dynamic therapy (NDT) as a physical clearance therapy for protein aggregates. Advanced glycation end-products (AGEs), which are aggregated proteins, have been implicated in diabetes, Alzheimer's, and heart disease. Herein, we report the use of the boron tracedrug UTX-51, under thermal neutron irradiation, as an NDT for the targeted clearance of glycated bovine serum albumin (Gly-BSA), a model of AGEs. Sodium dodecyl sulfate-polyacrylamide gel electrophoresis was performed to detect Gly-BSA decomposition by thermal neutron irradiation treated with UTX-51. The combination of UTX-51 with neutron irradiation showed a decrease in band intensity of Gly-BSA. We present our NDT strategy, which has been used for the targeted clearance of Gly-BSA, suggesting that NDT with boron tracedrugs can be used for the treatment of AGEs-related disease.
- 1 June 2014
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 88, 81-85
Dose-rate effect was observed in T98G glioma cells following BNCT
- 1 June 2014
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 88, 81-85
Dose-rate effect was observed in T98G glioma cells following BNCT
- Open Access
- 6 December 2013
- Published by Springer Nature
- p. 189-196
Internal Radiation Dose of KURRI Volunteers Working at Evacuation Shelters After TEPCO’s Fukushima Daiichi Nuclear Power Plant Accident
- 6 December 2013
- Published by Springer Nature
- p. 189-196
Open AccessInternal Radiation Dose of KURRI Volunteers Working at Evacuation Shelters After TEPCO’s Fukushima Daiichi Nuclear Power Plant Accident
- Open Access
- 7 February 2013
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 54 (4) , 769-774
Induced radioactivity in the blood of cancer patients following Boron Neutron Capture Therapy
Since 1990, Boron Neutron Capture Therapy (BNCT) has been used for over 400 cancer patients at the Kyoto University Research Reactor Institute (KURRI). After BNCT, the patients are radioactive and their (24)Na and (38)Cl levels can be detected via a Na-I scintillation counter. This activity is predominantly due to (24)Na, which has a half-life of 14.96 h and thus remains in the body for extended time periods. Radioactive (24)Na is mainly generated from (23)Na in the target tissue that is exposed to the neutron beam in BNCT. The purpose of this study is to evaluate the relationship between the radioactivity of blood (24)Na following BNCT and the absorbed gamma ray dose in the irradiated field. To assess blood (24)Na, 1 ml of peripheral blood was collected from 30 patients immediately after the exposure, and the radioactivity of blood (24)Na was determined using a germanium counter. The activity of (24)Na in the blood correlated with the absorbed gamma ray doses in the irradiated field. For the same absorbed gamma ray dose in the irradiated field, the activity of blood (24)Na was higher in patients with neck or lung tumors than in patients with brain or skin tumors. The reasons for these findings are not readily apparent, but the difference in the blood volume and the ratio of bone to soft tissue in the irradiated field, as well as the dose that leaked through the clinical collimator, may be responsible.
- 7 February 2013
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 54 (4) , 769-774
Open AccessInduced radioactivity in the blood of cancer patients following Boron Neutron Capture Therapy
Since 1990, Boron Neutron Capture Therapy (BNCT) has been used for over 400 cancer patients at the Kyoto University Research Reactor Institute (KURRI). After BNCT, the patients are radioactive and their (24)Na and (38)Cl levels can be detected via a Na-I scintillation counter. This activity is predominantly due to (24)Na, which has a half-life of 14.96 h and thus remains in the body for extended time periods. Radioactive (24)Na is mainly generated from (23)Na in the target tissue that is exposed to the neutron beam in BNCT. The purpose of this study is to evaluate the relationship between the radioactivity of blood (24)Na following BNCT and the absorbed gamma ray dose in the irradiated field. To assess blood (24)Na, 1 ml of peripheral blood was collected from 30 patients immediately after the exposure, and the radioactivity of blood (24)Na was determined using a germanium counter. The activity of (24)Na in the blood correlated with the absorbed gamma ray doses in the irradiated field. For the same absorbed gamma ray dose in the irradiated field, the activity of blood (24)Na was higher in patients with neck or lung tumors than in patients with brain or skin tumors. The reasons for these findings are not readily apparent, but the difference in the blood volume and the ratio of bone to soft tissue in the irradiated field, as well as the dose that leaked through the clinical collimator, may be responsible.
- Open Access
- 5 September 2011
- Published by Springer Nature in Radiation Oncology
- Vol. 6 (1) , 106
DNA double-strand break induction in Ku80-deficient CHO cells following Boron Neutron Capture Reaction
Boron neutron capture reaction (BNCR) is based on irradiation of tumors after accumulation of boron compound. 10B captures neutrons and produces an alpha (4He) particle and a recoiled lithium nucleus (7Li). These particles have the characteristics of high linear energy transfer (LET) radiation and have marked biological effects. The purpose of this study is to verify that BNCR will increase cell killing and slow disappearance of repair protein-related foci to a greater extent in DNA repair-deficient cells than in wild-type cells.
- 5 September 2011
- Published by Springer Nature in Radiation Oncology
- Vol. 6 (1) , 106
Open AccessDNA double-strand break induction in Ku80-deficient CHO cells following Boron Neutron Capture Reaction
Boron neutron capture reaction (BNCR) is based on irradiation of tumors after accumulation of boron compound. 10B captures neutrons and produces an alpha (4He) particle and a recoiled lithium nucleus (7Li). These particles have the characteristics of high linear energy transfer (LET) radiation and have marked biological effects. The purpose of this study is to verify that BNCR will increase cell killing and slow disappearance of repair protein-related foci to a greater extent in DNA repair-deficient cells than in wild-type cells.
- 1 January 2010
- Published by Elsevier in Mutation Research - Genetic Toxicology and Environmental Mutagenesis
- Vol. 695 (1-2) , 69-74
Ascorbic acid 2-glucocide reduces micronucleus induction in distant splenic T lymphocytes following head irradiation
- 1 January 2010
- Published by Elsevier in Mutation Research - Genetic Toxicology and Environmental Mutagenesis
- Vol. 695 (1-2) , 69-74
Ascorbic acid 2-glucocide reduces micronucleus induction in distant splenic T lymphocytes following head irradiation