Shuman He
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shuman He has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Craig A. Buchman
Departments Otolaryngology—Head and Neck Surgery, and
6 shared publicationsHolly F. B. Teagle
Department Otolaryngology—Head and Neck Surgery, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA; and
5 shared publicationsJohn H. Grose
Department Otolaryngology—Head and Neck Surgery, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA; and
5 shared publicationsDebora R. Hatch
Department of Otolaryngology—Ear, Nose & Throat, Eastern Virginia Medical School, Norfolk, Virginia, USA
2 shared publicationsJennifer Woodard
Department Otolaryngology—Head and Neck Surgery, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA; and
2 shared publications- Lisa R. Park
Department of Otolaryngology/Head and Neck Surgery University of North Carolina School of Medicine Chapel Hill North Carolina USA
2 shared publications
Latest Publications
- 1 May 2015
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 36 (3) , 377-379
The Electrically Evoked Cortical Auditory Event-Related Potential in Children With Auditory Brainstem Implants
Objective: This study explored the feasibility of measuring electrically evoked cortical auditory event-related potentials (eERPs) in children with auditory brainstem implants (ABIs). Design: Five children with unilateral ABIs ranging in age from 2.8 to 10.2 years (mean: 5.2 years) participated in this study. The stimulus was a 100-msec biphasic pulse train that was delivered to individual electrodes in a monopolar stimulation mode. Electrophysiological recordings of the onset eERP were conducted in all subjects. Results: The onset eERP was recorded in four subjects who demonstrated auditory perception. These eERP responses showed variations in waveform morphology across subjects and stimulating electrode locations. No eERPs were observed in one subject who received no auditory sensation from ABI stimulation. Conclusions: eERPs can be recorded in children with ABIs who develop auditory perception. The morphology of the eERP can vary across subjects and also across stimulating electrode locations within subjects.
- 1 May 2015
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 36 (3) , 377-379
The Electrically Evoked Cortical Auditory Event-Related Potential in Children With Auditory Brainstem Implants
Objective: This study explored the feasibility of measuring electrically evoked cortical auditory event-related potentials (eERPs) in children with auditory brainstem implants (ABIs). Design: Five children with unilateral ABIs ranging in age from 2.8 to 10.2 years (mean: 5.2 years) participated in this study. The stimulus was a 100-msec biphasic pulse train that was delivered to individual electrodes in a monopolar stimulation mode. Electrophysiological recordings of the onset eERP were conducted in all subjects. Results: The onset eERP was recorded in four subjects who demonstrated auditory perception. These eERP responses showed variations in waveform morphology across subjects and stimulating electrode locations. No eERPs were observed in one subject who received no auditory sensation from ABI stimulation. Conclusions: eERPs can be recorded in children with ABIs who develop auditory perception. The morphology of the eERP can vary across subjects and also across stimulating electrode locations within subjects.
- 1 May 2015
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 36 (3) , 289-301
Acoustically Evoked Auditory Change Complex in Children With Auditory Neuropathy Spectrum Disorder
Objectives: The overall aim of the study was to evaluate the feasibility of using electrophysiological measures of the auditory change complex (ACC) to identify candidates for cochlear implantation in children with auditory neuropathy spectrum disorder (ANSD). To achieve this overall aim, this study (1) assessed the feasibility of measuring the ACC evoked by temporal gaps in a group of children with ANSD across a wide age range and (2) investigated the association between gap detection thresholds (GDTs) measured by the ACC recordings and open-set speech-perception performance in these subjects. Design: Nineteen children with bilateral ANSD ranging in age between 1.9 and 14.9 years (mean: 7.8 years) participated in this study. Electrophysiological recordings of the auditory event-related potential (ERP), including the onset ERP response and the ACC, were completed in all subjects and open-set speech perception was evaluated for a subgroup of 16 subjects. For the ERP recordings, the stimulus was a Gaussian noise presented through ER-3A insert earphones to the test ear. Two stimulation conditions were used. In the “control condition,” the stimulus was an 800-msec Gaussian noise. In the “gapped condition,” the stimuli were two noise segments, each being 400 msec in duration, separated by one of five gaps (i.e., 5, 10, 20, 50, or 100 msec). The interstimulation interval was 1200 msec. The aided open-set speech perception ability was assessed using the Phonetically Balanced Kindergarten (PBK) word lists presented at 60 dB SPL using recorded testing material in a sound booth. For speech perception tests, subjects wore their hearing aids at the settings recommended by their clinical audiologists. For a subgroup of five subjects, psychophysical GDTs for the Gaussian noise were also assessed using a three-interval, three-alternative forced-choice procedure. Results: Responses evoked by the onset of the Gaussian noise (i.e., onset responses) were recorded in all stimulation conditions from all subjects tested in this study. The presence/absence, peak latency and amplitude, and response width of the onset response did not correlate with aided PBK word scores. The objective GDTs measured with the ACC recordings from 17 subjects ranged from 10 to 100 msec. The ACC was not recorded from two subjects for any gap durations tested in this study. There was a robust negative correlation between objective GDTs and aided PBK word scores. In general, subjects with prolonged objective GDTs showed low-aided PBK word scores. GDTs measured using electrophysiological recordings of the ACC correlated well with those measured using psychophysical procedures in four of five subjects who were evaluated using both procedures. Conclusions: The clinical application of the onset response in predicting open-set speech-perception ability is relatively limited in children with ANSD. The ACC recordings can be used to objectively evaluate temporal resolution abilities in children with ANSD having no severe comorbidities, and who are older than 1.9 years. The ACC can potentially be used as an objective tool to identify poor performers among children with ANSD using properly fit amplification, and who are thus, cochlear implant candidates.
- 1 May 2015
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 36 (3) , 289-301
Acoustically Evoked Auditory Change Complex in Children With Auditory Neuropathy Spectrum Disorder
Objectives: The overall aim of the study was to evaluate the feasibility of using electrophysiological measures of the auditory change complex (ACC) to identify candidates for cochlear implantation in children with auditory neuropathy spectrum disorder (ANSD). To achieve this overall aim, this study (1) assessed the feasibility of measuring the ACC evoked by temporal gaps in a group of children with ANSD across a wide age range and (2) investigated the association between gap detection thresholds (GDTs) measured by the ACC recordings and open-set speech-perception performance in these subjects. Design: Nineteen children with bilateral ANSD ranging in age between 1.9 and 14.9 years (mean: 7.8 years) participated in this study. Electrophysiological recordings of the auditory event-related potential (ERP), including the onset ERP response and the ACC, were completed in all subjects and open-set speech perception was evaluated for a subgroup of 16 subjects. For the ERP recordings, the stimulus was a Gaussian noise presented through ER-3A insert earphones to the test ear. Two stimulation conditions were used. In the “control condition,” the stimulus was an 800-msec Gaussian noise. In the “gapped condition,” the stimuli were two noise segments, each being 400 msec in duration, separated by one of five gaps (i.e., 5, 10, 20, 50, or 100 msec). The interstimulation interval was 1200 msec. The aided open-set speech perception ability was assessed using the Phonetically Balanced Kindergarten (PBK) word lists presented at 60 dB SPL using recorded testing material in a sound booth. For speech perception tests, subjects wore their hearing aids at the settings recommended by their clinical audiologists. For a subgroup of five subjects, psychophysical GDTs for the Gaussian noise were also assessed using a three-interval, three-alternative forced-choice procedure. Results: Responses evoked by the onset of the Gaussian noise (i.e., onset responses) were recorded in all stimulation conditions from all subjects tested in this study. The presence/absence, peak latency and amplitude, and response width of the onset response did not correlate with aided PBK word scores. The objective GDTs measured with the ACC recordings from 17 subjects ranged from 10 to 100 msec. The ACC was not recorded from two subjects for any gap durations tested in this study. There was a robust negative correlation between objective GDTs and aided PBK word scores. In general, subjects with prolonged objective GDTs showed low-aided PBK word scores. GDTs measured using electrophysiological recordings of the ACC correlated well with those measured using psychophysical procedures in four of five subjects who were evaluated using both procedures. Conclusions: The clinical application of the onset response in predicting open-set speech-perception ability is relatively limited in children with ANSD. The ACC recordings can be used to objectively evaluate temporal resolution abilities in children with ANSD having no severe comorbidities, and who are older than 1.9 years. The ACC can potentially be used as an objective tool to identify poor performers among children with ANSD using properly fit amplification, and who are thus, cochlear implant candidates.
- 1 May 2014
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 35 (3) , e63-e74
Objective Measures of Electrode Discrimination With Electrically Evoked Auditory Change Complex and Speech-Perception Abilities in Children With Auditory Neuropathy Spectrum Disorder
Objectives: This study aimed to (1) determine the sensitivity of the electrically evoked auditory change complex (eACC) to changes in stimulating electrode position; and (2) investigate the association between results of eACC measures and behavioral electrode discrimination and their association with speech-perception performance in pediatric cochlear implant (CI) users who have auditory neuropathy spectrum disorder (ANSD). Design: Fifteen children with ANSD ranging in age between 5.4 and 18.6 years participated in this study. All subjects used Cochlear Nucleus devices. For each subject, open-set speech-perception ability was assessed using the Phonetically Balanced Kindergarten word lists presented at 60 dB SPL, using monitored live voice in a sound booth. Behavioral and objective measures of electrode discrimination were assessed in a nonclinical test environment. The stimuli used to elicit these measures were 800 msec biphasic pulse trains delivered by a direct interface to the CI. Data were collected from two basic stimulation conditions. In the standard condition, the entire pulse train was delivered to a mid-array electrode (electrode 11 or 12) at the maximum comfortable level (C level). In the change condition, the stimulus was split into two 400 msec pulse train segments presented sequentially on two different electrodes. The stimulation level of the second 400 msec pulse train was loudness balanced to the C level of the mid-array electrode used in the standard condition. The separation between the pair of stimulating electrodes was systematically varied. For behavioral electrode-discrimination measures, each subject was required to determine whether he or she heard one or two sounds for stimuli presented in different stimulation conditions. For the eACC measures, two replicates of 100 artifact-free sweeps were recorded for each stimulation condition. Results: The eACC in response to changes in stimulating electrode position was recorded from all subjects with ANSD using direct electrical stimulation. Electrode-discrimination thresholds determined with the eACC and behavioral measures were consistent. Children with ANSD using CIs who showed poorer speech performance also required larger separations between the stimulating electrode pair to reliably elicit the eACC than subjects with better speech-perception performance. There was a robust correlation between electrode-discrimination capacities and speech-perception performances in subjects tested in this study. The effect of electrode separation on eACC amplitudes was not monotonic. Conclusions: These results demonstrate the feasibility of using eACC to evaluate electrode-discrimination capacities in children with ANSD. These results suggest that the eACC elicited by changes in stimulating electrode position holds great promise as an objective tool for evaluating spectral-pattern detection in such subjects, which may be predictive of their potential speech-perception performance.
- 1 May 2014
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 35 (3) , e63-e74
Objective Measures of Electrode Discrimination With Electrically Evoked Auditory Change Complex and Speech-Perception Abilities in Children With Auditory Neuropathy Spectrum Disorder
Objectives: This study aimed to (1) determine the sensitivity of the electrically evoked auditory change complex (eACC) to changes in stimulating electrode position; and (2) investigate the association between results of eACC measures and behavioral electrode discrimination and their association with speech-perception performance in pediatric cochlear implant (CI) users who have auditory neuropathy spectrum disorder (ANSD). Design: Fifteen children with ANSD ranging in age between 5.4 and 18.6 years participated in this study. All subjects used Cochlear Nucleus devices. For each subject, open-set speech-perception ability was assessed using the Phonetically Balanced Kindergarten word lists presented at 60 dB SPL, using monitored live voice in a sound booth. Behavioral and objective measures of electrode discrimination were assessed in a nonclinical test environment. The stimuli used to elicit these measures were 800 msec biphasic pulse trains delivered by a direct interface to the CI. Data were collected from two basic stimulation conditions. In the standard condition, the entire pulse train was delivered to a mid-array electrode (electrode 11 or 12) at the maximum comfortable level (C level). In the change condition, the stimulus was split into two 400 msec pulse train segments presented sequentially on two different electrodes. The stimulation level of the second 400 msec pulse train was loudness balanced to the C level of the mid-array electrode used in the standard condition. The separation between the pair of stimulating electrodes was systematically varied. For behavioral electrode-discrimination measures, each subject was required to determine whether he or she heard one or two sounds for stimuli presented in different stimulation conditions. For the eACC measures, two replicates of 100 artifact-free sweeps were recorded for each stimulation condition. Results: The eACC in response to changes in stimulating electrode position was recorded from all subjects with ANSD using direct electrical stimulation. Electrode-discrimination thresholds determined with the eACC and behavioral measures were consistent. Children with ANSD using CIs who showed poorer speech performance also required larger separations between the stimulating electrode pair to reliably elicit the eACC than subjects with better speech-perception performance. There was a robust correlation between electrode-discrimination capacities and speech-perception performances in subjects tested in this study. The effect of electrode separation on eACC amplitudes was not monotonic. Conclusions: These results demonstrate the feasibility of using eACC to evaluate electrode-discrimination capacities in children with ANSD. These results suggest that the eACC elicited by changes in stimulating electrode position holds great promise as an objective tool for evaluating spectral-pattern detection in such subjects, which may be predictive of their potential speech-perception performance.
- 1 November 2013
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 34 (6) , 733-744
Gap Detection Measured With Electrically Evoked Auditory Event–Related Potentials and Speech-Perception Abilities in Children With Auditory Neuropathy Spectrum Disorder
Objectives: This study aimed (1) to investigate the feasibility of recording the electrically evoked auditory event–related potential (eERP), including the onset P1-N1-P2 complex and the electrically evoked auditory change complex (EACC) in response to temporal gaps, in children with auditory neuropathy spectrum disorder (ANSD); and (2) to evaluate the relationship between these measures and speech-perception abilities in these subjects. Design: Fifteen ANSD children who are Cochlear Nucleus device users participated in this study. For each subject, the speech-processor microphone was bypassed and the eERPs were elicited by direct stimulation of one mid-array electrode (electrode 12). The stimulus was a train of biphasic current pulses 800 msec in duration. Two basic stimulation conditions were used to elicit the eERP. In the no-gap condition, the entire pulse train was delivered uninterrupted to electrode 12, and the onset P1-N1-P2 complex was measured relative to the stimulus onset. In the gapped condition, the stimulus consisted of two pulse train bursts, each being 400 msec in duration, presented sequentially on the same electrode and separated by one of five gaps (i.e., 5, 10, 20, 50, and 100 msec). Open-set speech-perception ability of these subjects with ANSD was assessed using the phonetically balanced kindergarten (PBK) word lists presented at 60 dB SPL, using monitored live voice in a sound booth. Results: The eERPs were recorded from all subjects with ANSD who participated in this study. There were no significant differences in test–retest reliability, root mean square amplitude or P1 latency for the onset P1-N1-P2 complex between subjects with good (>70% correct on PBK words) and poorer speech-perception performance. In general, the EACC showed less mature morphological characteristics than the onset P1-N1-P2 response recorded from the same subject. There was a robust correlation between the PBK word scores and the EACC thresholds for gap detection. Subjects with poorer speech-perception performance showed larger EACC thresholds in this study. Conclusions: These results demonstrate the feasibility of recording eERPs from implanted children with ANSD, using direct electrical stimulation. Temporal-processing deficits, as demonstrated by large EACC thresholds for gap detection, might account in part for the poor speech-perception performances observed in a subgroup of implanted subjects with ANSD. This finding suggests that the EACC elicited by changes in temporal continuity (i.e., gap) holds promise as a predictor of speech-perception ability among implanted children with ANSD.
- 1 November 2013
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 34 (6) , 733-744
Gap Detection Measured With Electrically Evoked Auditory Event–Related Potentials and Speech-Perception Abilities in Children With Auditory Neuropathy Spectrum Disorder
Objectives: This study aimed (1) to investigate the feasibility of recording the electrically evoked auditory event–related potential (eERP), including the onset P1-N1-P2 complex and the electrically evoked auditory change complex (EACC) in response to temporal gaps, in children with auditory neuropathy spectrum disorder (ANSD); and (2) to evaluate the relationship between these measures and speech-perception abilities in these subjects. Design: Fifteen ANSD children who are Cochlear Nucleus device users participated in this study. For each subject, the speech-processor microphone was bypassed and the eERPs were elicited by direct stimulation of one mid-array electrode (electrode 12). The stimulus was a train of biphasic current pulses 800 msec in duration. Two basic stimulation conditions were used to elicit the eERP. In the no-gap condition, the entire pulse train was delivered uninterrupted to electrode 12, and the onset P1-N1-P2 complex was measured relative to the stimulus onset. In the gapped condition, the stimulus consisted of two pulse train bursts, each being 400 msec in duration, presented sequentially on the same electrode and separated by one of five gaps (i.e., 5, 10, 20, 50, and 100 msec). Open-set speech-perception ability of these subjects with ANSD was assessed using the phonetically balanced kindergarten (PBK) word lists presented at 60 dB SPL, using monitored live voice in a sound booth. Results: The eERPs were recorded from all subjects with ANSD who participated in this study. There were no significant differences in test–retest reliability, root mean square amplitude or P1 latency for the onset P1-N1-P2 complex between subjects with good (>70% correct on PBK words) and poorer speech-perception performance. In general, the EACC showed less mature morphological characteristics than the onset P1-N1-P2 response recorded from the same subject. There was a robust correlation between the PBK word scores and the EACC thresholds for gap detection. Subjects with poorer speech-perception performance showed larger EACC thresholds in this study. Conclusions: These results demonstrate the feasibility of recording eERPs from implanted children with ANSD, using direct electrical stimulation. Temporal-processing deficits, as demonstrated by large EACC thresholds for gap detection, might account in part for the poor speech-perception performances observed in a subgroup of implanted subjects with ANSD. This finding suggests that the EACC elicited by changes in temporal continuity (i.e., gap) holds promise as a predictor of speech-perception ability among implanted children with ANSD.
- 25 April 2013
- Published by Wiley in The Laryngoscope
- Vol. 123 (11) , 2859-2861
Objective hearing threshold estimation in children with auditory neuropathy spectrum disorder
Laryngoscope, 123:2859–2861, 2013
- 25 April 2013
- Published by Wiley in The Laryngoscope
- Vol. 123 (11) , 2859-2861
Objective hearing threshold estimation in children with auditory neuropathy spectrum disorder
Laryngoscope, 123:2859–2861, 2013
- 3 September 2012
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 51 (10) , 771-782
Auditory discrimination: The relationship between psychophysical and electrophysiological measures
Objectives: This study aimed to (1) investigate the relationship between the acoustic change complex (ACC) and perceptual measures of frequency and intensity discrimination, and gap detection; and (2) examine the effects of acoustic change on the amplitudes and latencies of the ACC. Design: Psychophysical thresholds for frequency and intensity discrimination and gap detection, as well as ACCs elicited by stimuli containing increments in frequency, or intensity or gaps, were recorded from the same group of subjects. The magnitude of the acoustic change was systematically varied for the ACC recording. Study sample: Twenty-six adults with normal hearing, ranging in age between 19 and 39 years. Results: Electrophysiological and psychophysical measures for frequency and intensity discrimination were significantly correlated. Electrophysiological thresholds were comparable to psychophysical thresholds for intensity discrimination but were higher than psychophysical thresholds for gap detection and frequency discrimination. Increasing the magnitude of acoustic change increased the ACC amplitude but did not show consistent effects across acoustic dimensions for ACC latency. Conclusions: The ACC can be used as an objective index of auditory discrimination in frequency and intensity. The ACC amplitude is a better indicator for auditory processing than the ACC latency.
- 3 September 2012
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 51 (10) , 771-782
Auditory discrimination: The relationship between psychophysical and electrophysiological measures
Objectives: This study aimed to (1) investigate the relationship between the acoustic change complex (ACC) and perceptual measures of frequency and intensity discrimination, and gap detection; and (2) examine the effects of acoustic change on the amplitudes and latencies of the ACC. Design: Psychophysical thresholds for frequency and intensity discrimination and gap detection, as well as ACCs elicited by stimuli containing increments in frequency, or intensity or gaps, were recorded from the same group of subjects. The magnitude of the acoustic change was systematically varied for the ACC recording. Study sample: Twenty-six adults with normal hearing, ranging in age between 19 and 39 years. Results: Electrophysiological and psychophysical measures for frequency and intensity discrimination were significantly correlated. Electrophysiological thresholds were comparable to psychophysical thresholds for intensity discrimination but were higher than psychophysical thresholds for gap detection and frequency discrimination. Increasing the magnitude of acoustic change increased the ACC amplitude but did not show consistent effects across acoustic dimensions for ACC latency. Conclusions: The ACC can be used as an objective index of auditory discrimination in frequency and intensity. The ACC amplitude is a better indicator for auditory processing than the ACC latency.
- 1 January 2012
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 33 (1) , 57-68
Preliminary Results of the Relationship Between the Binaural Interaction Component of the Electrically Evoked Auditory Brainstem Response and Interaural Pitch Comparisons in Bilateral Cochlear Implant Recipients
Objective: The purpose of this study was to investigate the relationship between electrophysiologic measures of the binaural interaction component (BIC) of the electrically evoked auditory brainstem response and psychophysical measures of interaural pitch comparisons in Nucleus bilateral cochlear implant users. Design: Data were collected for 10 postlingually deafened adult cochlear implant users. Each subject conducted an interaural pitch-comparison task using a biphasic pulse train with a pulse rate of 1000 pulses per second (pps) at high stimulation levels. Stimuli were presented in a two-interval, two-alternative forced-choice procedure with roving current variations. A subgroup of four subjects repeated the task at low stimulation levels. BICs were measured using loudness balanced, biphasic current pulses presented at a rate of 19.9 pps for each subject by pairing the electrode 12 (out of 22 intracochlear electrodes) in the right ear with each of 11 electrodes spaced across the electrode array in the left ear. The BIC was measured at high stimulation levels in 10 subjects and at low stimulation levels in 7 subjects. Because of differences in stimulation rate used in BIC measures and interaural pitch comparisons, the actual stimulation levels were different in these two measures. The relationship between BIC responses and results of interaural pitch comparisons was evaluated for each of the individual subjects and at the group level. Evaluation was carried out separately for results obtained at high and low stimulation levels. Results: There was no significant correlation between results of BIC measures and interaural pitch comparisons on either the individual or group levels. Lower stimulation level did not improve the relationship between these two measures. Conclusions: No significant correlations between psychophysical measures of interaural pitch comparisons and electrophysiologic measures of the BIC of the electrically evoked auditory brainstem response were found. The lack of correlation may be attributed to methods used to quantify the data, small number of subjects retested at low stimulation levels, and central processing components involved in the interaural pitch-comparison task.
- 1 January 2012
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 33 (1) , 57-68
Preliminary Results of the Relationship Between the Binaural Interaction Component of the Electrically Evoked Auditory Brainstem Response and Interaural Pitch Comparisons in Bilateral Cochlear Implant Recipients
Objective: The purpose of this study was to investigate the relationship between electrophysiologic measures of the binaural interaction component (BIC) of the electrically evoked auditory brainstem response and psychophysical measures of interaural pitch comparisons in Nucleus bilateral cochlear implant users. Design: Data were collected for 10 postlingually deafened adult cochlear implant users. Each subject conducted an interaural pitch-comparison task using a biphasic pulse train with a pulse rate of 1000 pulses per second (pps) at high stimulation levels. Stimuli were presented in a two-interval, two-alternative forced-choice procedure with roving current variations. A subgroup of four subjects repeated the task at low stimulation levels. BICs were measured using loudness balanced, biphasic current pulses presented at a rate of 19.9 pps for each subject by pairing the electrode 12 (out of 22 intracochlear electrodes) in the right ear with each of 11 electrodes spaced across the electrode array in the left ear. The BIC was measured at high stimulation levels in 10 subjects and at low stimulation levels in 7 subjects. Because of differences in stimulation rate used in BIC measures and interaural pitch comparisons, the actual stimulation levels were different in these two measures. The relationship between BIC responses and results of interaural pitch comparisons was evaluated for each of the individual subjects and at the group level. Evaluation was carried out separately for results obtained at high and low stimulation levels. Results: There was no significant correlation between results of BIC measures and interaural pitch comparisons on either the individual or group levels. Lower stimulation level did not improve the relationship between these two measures. Conclusions: No significant correlations between psychophysical measures of interaural pitch comparisons and electrophysiologic measures of the BIC of the electrically evoked auditory brainstem response were found. The lack of correlation may be attributed to methods used to quantify the data, small number of subjects retested at low stimulation levels, and central processing components involved in the interaural pitch-comparison task.
- 1 June 2010
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 127 (6) , 3643-3653
Monaural temporal integration and temporally selective listening in children and adults
This study used two paradigms to investigate the development of temporal integration and temporally selective listening. Experiment 1 measured detection as a function of duration for a pure tone at 1625 or 6500 Hz. At both frequencies thresholds of children younger than 7 years old were higher than those for older children and adults. The pattern of temporal integration was similar across groups for the 6500-Hz signal, but younger children showed relatively more temporal integration for the 1625-Hz signal due to high thresholds for the briefest 1625-Hz signal. Experiment 2 measured detection thresholds for one or for three brief tone pips presented in a noise masker. In one set of conditions, the noise masker consisted of 100-ms steady bursts interleaved with 10-ms temporal gaps. In other conditions, the level of the central 50 ms of the 100-ms masking noise bursts was adjusted by either +6 or −6 dB. Children showed higher thresholds but similar temporal integration compared with adults. Overall, these data suggest that children are less efficient than adults in weighting the output of the monaural temporal window at 1625 but not 6500 Hz. Children are efficient in combining energy from brief temporal epochs that are separated by noise.
- 1 June 2010
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 127 (6) , 3643-3653
Monaural temporal integration and temporally selective listening in children and adults
This study used two paradigms to investigate the development of temporal integration and temporally selective listening. Experiment 1 measured detection as a function of duration for a pure tone at 1625 or 6500 Hz. At both frequencies thresholds of children younger than 7 years old were higher than those for older children and adults. The pattern of temporal integration was similar across groups for the 6500-Hz signal, but younger children showed relatively more temporal integration for the 1625-Hz signal due to high thresholds for the briefest 1625-Hz signal. Experiment 2 measured detection thresholds for one or for three brief tone pips presented in a noise masker. In one set of conditions, the noise masker consisted of 100-ms steady bursts interleaved with 10-ms temporal gaps. In other conditions, the level of the central 50 ms of the 100-ms masking noise bursts was adjusted by either +6 or −6 dB. Children showed higher thresholds but similar temporal integration compared with adults. Overall, these data suggest that children are less efficient than adults in weighting the output of the monaural temporal window at 1625 but not 6500 Hz. Children are efficient in combining energy from brief temporal epochs that are separated by noise.