Daniel E. Mazur
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Daniel E. Mazur has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- John M. Toomasian
Extracorporeal Life Support Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA
1 shared publication Kathryn R. Osterholzer
From the Michigan Critical Care Consultants, Inc, Ann Arbor, Michigan
1 shared publicationScott I. Merz
From the Michigan Critical Care Consultants, Inc, Ann Arbor, Michigan
1 shared publication
Latest Publications
- 1 September 2008
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 54 (5) , 523-528
A Novel, Low Cost, Disposable, Pediatric Pulsatile Rotary Ventricular Pump For Cardiac Surgery that Provides a Physiological Flow Pattern
Research is underway to develop a novel, low cost, disposable pediatric pulsatile rotary ventricular pump (PRVP) for cardiac surgery that provides a physiological flow pattern. This is believed to offer reduced morbidity and risk exposure within this population. The PRVP will have a durable design suitable for use in short- to mid-length prolonged support after surgery without changing pumps. The design is based on proprietary MC3 technology which provides variable pumping volume per stroke, thereby allowing the pump to respond to hemodynamic status changes of the patient. The novel pump design also possesses safety advantages that prevent retrograde flow, and maintain safe circuit pressures upon occlusion of the inlet and outlet tubing. The design is ideal for simple, safe and natural flow support. Computational methods have been developed that predict output for pump chambers of varying geometry. A scaled chamber and pump head (diameter = 4 in) were prototyped to demonstrate target performance for pediatrics (2 L/min at 100 rpm). A novel means of creating a pulsatile flow and pressure output at constant RPM was developed and demonstrated to create significant surplus hydraulic energy (>10%) in a simplified mock patient circuit.
- 1 September 2008
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 54 (5) , 523-528
A Novel, Low Cost, Disposable, Pediatric Pulsatile Rotary Ventricular Pump For Cardiac Surgery that Provides a Physiological Flow Pattern
Research is underway to develop a novel, low cost, disposable pediatric pulsatile rotary ventricular pump (PRVP) for cardiac surgery that provides a physiological flow pattern. This is believed to offer reduced morbidity and risk exposure within this population. The PRVP will have a durable design suitable for use in short- to mid-length prolonged support after surgery without changing pumps. The design is based on proprietary MC3 technology which provides variable pumping volume per stroke, thereby allowing the pump to respond to hemodynamic status changes of the patient. The novel pump design also possesses safety advantages that prevent retrograde flow, and maintain safe circuit pressures upon occlusion of the inlet and outlet tubing. The design is ideal for simple, safe and natural flow support. Computational methods have been developed that predict output for pump chambers of varying geometry. A scaled chamber and pump head (diameter = 4 in) were prototyped to demonstrate target performance for pediatrics (2 L/min at 100 rpm). A novel means of creating a pulsatile flow and pressure output at constant RPM was developed and demonstrated to create significant surplus hydraulic energy (>10%) in a simplified mock patient circuit.