GFGeorge D. Fulk

George D. Fulk

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


George D. Fulk has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers

    Predicting Home and Community Walking Activity Poststroke

    by George D. Fulk, Ying He, Pierce Boyne, Kari Dunning

    Background and Purpose—Walking ability poststroke is commonly assessed using gait speed categories developed by Perry et al. The purpose of this study was to reexamine factors that predict home and community ambulators determined from real-world walking activity data using activity monitors. Methods—Secondary analyses of real-world walking activity from 2 stroke trials. Home (100–2499 steps/d), most limited community (2500–4499 steps/d), least limited community (5000–74 999), and full community (≥7500 steps/d) walking categories were developed based on normative data. Independent variables to predict walking categories were comfortable and fast gait speed, 6-minute walk test, Berg Balance Scale, Fugl Meyer, and Stroke Impact Scale. Data were analyzed using multivariate analyses to identify significant variables associated with walking categories, bootstrap method to select the most stable model and receiver-operating characteristic to identify cutoff values. Results—Data from 441 individuals poststroke were analyzed. The 6-minute walk test, Fugl Meyer, and Berg Balance Scale combined were the strongest predictors of home versus community and limited versus unlimited community ambulators. The 6-minute walk test was the strongest individual variable in predicting home versus community (receiver-operating characteristic area under curve=0.82) and limited versus full community ambulators (receiver-operating characteristic area under curve=0.76). A comfortable gait speed of 0.49 m/s discriminated between home and community and a comfortable gait speed of 0.93 m/s discriminated between limited community and full community ambulators. Conclusions—The 6-minute walk test was better able to discriminate among home, limited community, and full community ambulators than comfortable gait speed. Gait speed values commonly used to distinguish between home and community walkers may overestimate walking activity.


  • Self-Selected and Maximal Walking Speeds Provide Greater Insight Into Fall Status Than Walking Speed Reserve Among Community-Dwelling Older Adults

    by Addie Middleton, George D. Fulk, Troy M. Herter, Michael W. Med Beets, Jonathan Dpt Donley, Stacy L. Fritz

    Objective To determine the degree to which self-selected walking speed (SSWS), maximal walking speed (MWS), and walking speed reserve (WSR) are associated with fall status among community-dwelling older adults. Design WS and 1-year falls history data were collected on 217 community-dwelling older adults (median age = 82, range 65–93 years) at a local outpatient PT clinic and local retirement communities and senior centers. WSR was calculated as a difference (WSRdiff = MWS − SSWS) and ratio (WSRratio = MWS/SSWS). Results SSWS (P < 0.001), MWS (P < 0.001), and WSRdiff (P < 0.01) were associated with fall status. The cutpoints identified were 0.76 m/s for SSWS (65.4% sensitivity, 70.9% specificity), 1.13 m/s for MWS (76.6% sensitivity, 60.0% specificity), and 0.24 m/s for WSRdiff (56.1% sensitivity, 70.9% specificity). SSWS and MWS better discriminated between fallers and non-fallers (SSWS: AUC = 0.69, MWS: AUC = 0.71) than WSRdiff (AUC = 0.64). Conclusions SSWS and MWS seem to be equally informative measures for assessing fall status in community-dwelling older adults. Older adults with SSWSs less than 0.76 m/s and those with MWSs less than 1.13 m/s may benefit from further fall risk assessment. Combining SSWS and MWS to calculate an individual’s WSR does not provide additional insight into fall status in this population. To Claim CME Credits: Complete the self-assessment activity and evaluation online at http://www.physiatry.org/JournalCME CME Objectives: Upon completion of this article, the reader should be able to: (1) Describe the different methods for calculating walking speed reserve and discuss the potential of the metric as an outcome measure; (2) Explain the degree to which self-selected walking speed, maximal walking speed, and walking speed reserve are associated with fall status among community-dwelling older adults; and (3) Discuss potential limitations to using walking speed reserve to identify fall status in populations without mobility restrictions. Level: Advanced Accreditation: The Association of Academic Physiatrists is accredited by the Accreditation Council for Continuing Medical Education to provide continuing medical education for physicians. The Association of Academic Physiatrists designates this activity for a maximum of 1.5 AMA PRA Category 1 Credit(s)™. Physicians should only claim credit commensurate with the extent of their participation in the activity.


  • Identifying Activity Levels and Steps of People With Stroke Using a Novel Shoe-Based Sensor

    by George D. Fulk, S. Ryan Edgar, Rebecca Bierwirth, Phil Hart, Paulo Lopez-Meyer, Edward Sazonov

    Background/Purpose: Advances in sensor technologies provide a method to accurately assess activity levels of people with stroke in their community. This information could be used to determine the effectiveness of rehabilitation interventions as well as provide behavior-enhancing feedback. The purpose of this study was to assess the accuracy of a novel shoe-based sensor system (SmartShoe) to identify different functional postures and steps in people with stroke. The SmartShoe system consists of five force-sensitive resistors built into a flexible insole and an accelerometer on the back of the shoe. Pressure and acceleration data are sent via Bluetooth to a smart phone. Methods: Participants with stroke wore the SmartShoe while they performed activities of daily living (ADLs) in sitting, standing, and walking positions. Data from four participants were used to develop a multilayer perceptron artificial neural network (ANN) to identify sitting, standing, and walking. A signal-processing algorithm used data from the pressure sensors to estimate the number of steps taken while walking. The accuracy, precision, and recall of the ANN for identifying the three functional postures were calculated with data from a different set of participants. Agreement between steps identified by SmartShoe and actual steps taken was analyzed by the Bland Altman method. Results: The SmartShoe was able to accurately identify sitting, standing, and walking. Accuracy, precision, and recall were all greater than 95%. The mean difference between steps identified by SmartShoe and actual steps was less than one step. Discussion: The SmartShoe was able to accurately identify different functional postures, using a unique combination of pressure and acceleration data, of people with stroke as they performed different ADLs. There was a strong level of agreement between actual steps taken and steps identified by the SmartShoe. Further study is needed to determine whether the SmartShoe could be used to provide valid information on activity levels of people with stroke while they go about their daily lives in their home and community.


  • The Design and Initial Experimental Validation of an Active Myoelectric Transfemoral Prosthesis

    by Carl D. Hoover, George D. Fulk, Kevin B. Fite

    This paper describes a single degree-of-freedom active-knee transfemoral prosthesis to be used as a test bed for the development of architectures for myoelectric control. The development of an active-knee transfemoral prosthesis is motivated by the inability of passive commercial prostheses to provide the joint power required at the knee for many activities of daily living such as reciprocal stair ascent, which requires knee power outputs of up to 4 W/kg. Study of myoelectric control based on surface electromyogram (EMG) measurements of muscles in the residual limb is motivated by the desire to restore direct volitional control of the knee using a minimally-invasive neuromuscular control interface. The presented work describes the design of a transfemoral prosthesis prototype including the structure, actuation, instrumentation, electronics, and real-time control architecture. The performance characteristics of the prototype are discussed in the context of the requisite knee energetics for a variety of common locomotive functions. This paper additionally describes the development of a single-subject diagnostic socket with wall-embedded surface EMG electrodes and the implementation of a control architecture for myoelectric modulation of knee impedance. Experimental results of level walking for a single subject with unilateral transfemoral amputation demonstrate the potential for direct EMG-based control of locomotive function.


  • Automatic Detection of Temporal Gait Parameters in Poststroke Individuals

    by P. Lopez-Meyer, G. D. Fulk, E. S. Sazonov

    Approximately one-third of people who recover from a stroke require some form of assistance to walk. Repetitive task-oriented rehabilitation interventions have been shown to improve motor control and function in people with stroke. Our long-term goal is to design and test an intensive task-oriented intervention that will utilize the two primary components of constrained-induced movement therapy: massed, task-oriented training and behavioral methods to increase use of the affected limb in the real world. The technological component of the intervention is based on a wearable footwear-based sensor system that monitors relative activity levels, functional utilization, and gait parameters of affected and unaffected lower extremities. The purpose of this study is to describe a methodology to automatically identify temporal gait parameters of poststroke individuals to be used in assessment of functional utilization of the affected lower extremity as a part of behavior enhancing feedback. An algorithm accounting for intersubject variability is capable of achieving estimation error in the range of 2.6-18.6% producing comparable results for healthy and poststroke subjects. The proposed methodology is based on inexpensive and user-friendly technology that will enable research and clinical applications for rehabilitation of people who have experienced a stroke.


  • Estimating Clinically Important Change in Gait Speed in People With Stroke Undergoing Outpatient Rehabilitation

    by George D. Fulk, Miriam Ot Ludwig, Kari Dunning, Sue Pt Golden, Pierce Bs Boyne, Trent Pt West

    Background and Purpose: Gait speed is commonly used to assess walking ability in people with stroke. It is not clear how much change in gait speed reflects an important change in walking ability. The purpose of this study was to estimate clinically important changes in gait speed by using 2 different anchors for what is considered “important”: stroke survivors and physical therapists perceptions of change in walking ability. Methods: Participants underwent outpatient physical therapy (mean 56 days post-stroke) after a first-time stroke. Self-selected gait speed was measured at admission and discharge. At discharge, participants and their physical therapists rated their perceived change in walking ability on a 15-point ordinal Global Rating of Change (GROC) scale. Estimated important change values for gait speed were calculated by using receiver operating characteristics curves, with the participants and physical therapists GROC as the anchors. Results: The mean (SD) initial gait speed of all participants was 0.56 (0.22) m/s. The estimated important change in gait speed ranged from 0.175 m/s (participants perceived change in walking ability) to 0.190 m/s (physical therapists perceived change in walking ability), depending on the anchor. Discussion and Conclusions: During the subacute stage of recovery, individuals poststroke who experience improvements in gait speed of 0.175 m/s or greater are likely to exhibit a meaningful improvement in walking ability. The estimated clinically important change value of 0.175 m/s can be used by clinicians to set goals and interpret change in individual patients and by researchers to compare important change between groups.


  • Predicting Home and Community Walking Activity in People With Stroke

    by George D. Fulk, Chelsea Reynolds, Sumona Mondal, Judith E. Deutsch


  • Open Access

    The effects of diabetes and/or peripheral neuropathy in detecting short postural perturbations in mature adults

    by George D Fulk, Charles J Robinson, Sumona Mondal, Christopher M Storey, Anne M Hollister

    This study explored the effects of diabetes mellitus (DM) and peripheral neuropathy (PN) on the ability to detect near-threshold postural perturbations.


  • Test-Retest Reliability and Minimal Detectable Change of Gait Speed in Individuals Undergoing Rehabilitation After Stroke

    by George D. Fulk, John L. Echternach

    Gait speed is commonly used to assess walking ability in persons with stroke. Previous research related to the psychometric properties of gait speed has been conducted primarily with individuals who were able to walk independently and/or were in the later stages of recovery after stroke. The purpose of this research was to examine the test-retest reliability and minimal detectable change (MDC90) of gait speed in individuals with stroke who required varying levels of assistance to ambulate during rehabilitation. Patients who could ambulate with or without physical assistance and were undergoing inpatient rehabilitation were recruited. Gait speed was measured over the middle five meters of a nine-meter walk at a comfortable pace. Data were analyzed using the intraclass correlation coefficient (ICC2,1) and the MDC90. Thirty-five patients who were a mean 34.5 (standard deviation = 17.7) days post-stroke agreed to participate. For all the subjects combined, the ICC2,1 was 0.862 and MDC90 was 0.30 m/sec. For the 13 subjects who required physical assistance to walk, the ICC2,1 = 0.971 and MDC90 = 0.07 m/sec. For the 22 subjects who could walk without physical assistance, the ICC2,1 = 0.80 and MDC90 = 0.36 m/sec. Gait speed is a reliable measure of walking ability for a wide variety of patients undergoing rehabilitation after stroke. Gait speed is more sensitive to change in patients who require physical assistance to walk than in those who can walk without assistance. A change of more than 0.30 m/sec may be necessary in order to determine whether a change in gait speed exceeds measurement error and patient variability.


  • Clinometric properties of the six-minute walk test in individuals undergoing rehabilitation poststroke

    by George D Fulk, John L Echternach, Leah Nof, Susan O'SUllivan

    The 6-minute walk test (6MWT) is commonly used to measure walking ability. The purpose of this study was to determine the test-retest reliability and concurrent and construct validity of the 6MWT in patients who were actively undergoing inpatient rehabilitation poststroke. Thirty-seven patients undergoing inpatient rehabilitation after a stroke participated; mean age was 66.3 years and mean time since stroke was 33.7 days. Patients underwent two 6MWT trials with 1–3 days between trials. Additional outcome measures taken were gait speed and the Functional Independence MeasureTM (FIMTM). The 6MWT exhibited high test-retest reliability; ICC2,1 0.973 (95% CI=0.925–0.988) and a minimal detectable change (MDC90) of 54.1 m. The 6MWT was strongly to moderately correlated with gait speed (r=0.89), locomotion (walk) FIMTM (r=0.69), and motor FIMTM (r=0.52). The 6MWT is a clinically useful measure of walking ability poststroke. It is reliable and is related to other measures of walking ability and function that are commonly used during rehabilitation after stroke.