Joseph A. C. Humphrey
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Joseph A. C. Humphrey has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Charlotte Barbier
Oak Ridge National Laboratory, Oak Ridge, TN
2 shared publications DeForest Mellon
Department of Biology, University of Virginia, Charlottesville, VA 22904,USA
1 shared publicationE.S. Dykes
1 shared publication- Eric Maslen
BRG Machinery Consulting LLC, North Garden, VA 22959, USA
1 shared publication J. Patrick LeDuc
Department of Chemistry, University of Virginia, McCormick Road, Charlottesville, VA 22904-4319, United States
1 shared publicationJames P. Landers
Department of Chemistry, University of Virginia, McCormick Road, Charlottesville, VA 22904-4319, United States
1 shared publication
Latest Publications
- 17 February 2010
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 7 (49) , 1243-1246
Corrections to the theory and the optimal line in the swimming diagram of Taylor (1952)
The analysis of undulatory swimming gaits requires knowledge of the fluid forces acting on the animal body during swimming. In his classical 1952 paper, Taylor analysed this problem using a ‘resistive-force’ theory. The theory was used to characterize the undulatory gaits that result in the smallest energy dissipation to the fluid for a given swim velocity. The optimal gaits thus found were compared with data recorded from movies of a snake and a leech swimming. This report identifies and corrects a mathematical error in Taylor’s paper, showing that his theory applies even better to animals of circular cross section.
- 17 February 2010
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 7 (49) , 1243-1246
Corrections to the theory and the optimal line in the swimming diagram of Taylor (1952)
The analysis of undulatory swimming gaits requires knowledge of the fluid forces acting on the animal body during swimming. In his classical 1952 paper, Taylor analysed this problem using a ‘resistive-force’ theory. The theory was used to characterize the undulatory gaits that result in the smallest energy dissipation to the fluid for a given swim velocity. The optimal gaits thus found were compared with data recorded from movies of a snake and a leech swimming. This report identifies and corrects a mathematical error in Taylor’s paper, showing that his theory applies even better to animals of circular cross section.
- 19 February 2009
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 6 (40) , 1047-1064
Response of cricket and spider motion-sensing hairs to airflow pulsations
Closed-form analytical solutions are presented for the angular displacement, velocity and acceleration of motion-sensing filiform hairs exposed to airflow pulsations of short time duration. The specific situations of interest correspond to a spider intentionally moving towards a cricket, or an insect unintentionally moving towards or flying past a spider. The trichobothria of the spider Cupiennius salei and the cercal hairs of the cricket Gryllus bimaculatus are explored. Guided by earlier work, the spatial characteristics of the velocity field due to a flow pulsation are approximated by the local incompressible flow field due to a moving sphere. This spatial field is everywhere modulated in time by a Gaussian function represented by the summation of an infinite Fourier series, thus allowing an exploration of the spectral dependence of hair motion. Owing to their smaller total inertia, torsional restoring constant and total damping constant, short hairs are found to be significantly more responsive than long hairs to a flow pulsation. It is also found that the spider trichobothria are underdamped, while the cercal hairs of the cricket are overdamped. As a consequence, the spider hairs are more responsive to sudden air motions. Analysis shows that while two spiders of different characteristic sizes and lunge velocities can generate pulsations with comparable energy content, the associated velocity fields display different patterns of spatial decay with distance from the pulsation source. As a consequence, a small spider lunging at a high velocity generates a smaller telltale far-field velocity signal than a larger spider lunging at a lower velocity. The results obtained are in broad agreement with several of the observations and conclusions derived from combined flow and behavioural experiments performed by Casas et al . for running spiders, and by Dangles et al . for spiders and a physical model of spiders lunging at crickets.
- 19 February 2009
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 6 (40) , 1047-1064
Response of cricket and spider motion-sensing hairs to airflow pulsations
Closed-form analytical solutions are presented for the angular displacement, velocity and acceleration of motion-sensing filiform hairs exposed to airflow pulsations of short time duration. The specific situations of interest correspond to a spider intentionally moving towards a cricket, or an insect unintentionally moving towards or flying past a spider. The trichobothria of the spider Cupiennius salei and the cercal hairs of the cricket Gryllus bimaculatus are explored. Guided by earlier work, the spatial characteristics of the velocity field due to a flow pulsation are approximated by the local incompressible flow field due to a moving sphere. This spatial field is everywhere modulated in time by a Gaussian function represented by the summation of an infinite Fourier series, thus allowing an exploration of the spectral dependence of hair motion. Owing to their smaller total inertia, torsional restoring constant and total damping constant, short hairs are found to be significantly more responsive than long hairs to a flow pulsation. It is also found that the spider trichobothria are underdamped, while the cercal hairs of the cricket are overdamped. As a consequence, the spider hairs are more responsive to sudden air motions. Analysis shows that while two spiders of different characteristic sizes and lunge velocities can generate pulsations with comparable energy content, the associated velocity fields display different patterns of spatial decay with distance from the pulsation source. As a consequence, a small spider lunging at a high velocity generates a smaller telltale far-field velocity signal than a larger spider lunging at a lower velocity. The results obtained are in broad agreement with several of the observations and conclusions derived from combined flow and behavioural experiments performed by Casas et al . for running spiders, and by Dangles et al . for spiders and a physical model of spiders lunging at crickets.
- 21 January 2009
- Published by Elsevier in International Journal of Heat and Fluid Flow
- Vol. 30 (2) , 389
Erratum to: Vortex dynamics in confined counter-current shearing flows with applications to mixing [Inter. J. Heat Fluid Flow 29 (2008) 1089–1102]
- 21 January 2009
- Published by Elsevier in International Journal of Heat and Fluid Flow
- Vol. 30 (2) , 389
Erratum to: Vortex dynamics in confined counter-current shearing flows with applications to mixing [Inter. J. Heat Fluid Flow 29 (2008) 1089–1102]
- 16 October 2008
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 6 (36) , 641-653
Drag force acting on a neuromast in the fish lateral line trunk canal. II. Analytical modelling of parameter dependencies
In Part I of this two-part study, the coupled flows external and internal to the fish lateral line trunk canal were consecutively calculated by solving the Navier–Stokes (N–S) equations numerically in each domain. With the external flow known, the solution for the internal flow was obtained using a parallelepiped to simulate the neuromast cupula present between a pair of consecutive pores, allowing the calculation of the drag force acting on the neuromast cupula. While physically rigorous and accurate, the numerical approach is tedious and inefficient since it does not readily reveal the parameter dependencies of the drag force. In Part II of this work we present an analytically based physical–mathematical model for rapidly calculating the drag force acting on a neuromast cupula. The cupula is well approximated as an immobile sphere located inside a tube-shaped canal segment of circular cross section containing a constant property fluid in a steady-periodic oscillating state of motion. The analytical expression derived for the dimensionless drag force is of the form , where | F N | is the amplitude of the drag force; | P L − P R | is the amplitude of the pressure difference driving the flow in the interpore tube segment; d / D is the ratio of sphere diameter to tube diameter; L t / D is the ratio of interpore tube segment length to tube diameter; and is the oscillating flow kinetic Reynolds number (a dimensionless frequency). Present results show that the dimensionless drag force amplitude increases with decreasing L t / D and maximizes in the range 0.65≤ d / D ≤0.85, depending on the values of L t / D and . It is also found that in the biologically relevant range of dimensionless frequencies 1≤ ≤20 and segment lengths 4≤ L t / D ≤16, the sphere tube (neuromast–canal) system acts as a low-pass filter for values d / D ≤0.75, approximately. For larger values of d / D the system is equally sensitive to all frequencies, but the drag force is significantly decreased. Comparisons with N–S calculations of the drag force show good agreement with the analytical model results. By revealing the parameter dependencies of the drag force, the model serves to guide biological understanding and the optimized design of corresponding bioinspired artificial sensors.
- 16 October 2008
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 6 (36) , 641-653
Drag force acting on a neuromast in the fish lateral line trunk canal. II. Analytical modelling of parameter dependencies
In Part I of this two-part study, the coupled flows external and internal to the fish lateral line trunk canal were consecutively calculated by solving the Navier–Stokes (N–S) equations numerically in each domain. With the external flow known, the solution for the internal flow was obtained using a parallelepiped to simulate the neuromast cupula present between a pair of consecutive pores, allowing the calculation of the drag force acting on the neuromast cupula. While physically rigorous and accurate, the numerical approach is tedious and inefficient since it does not readily reveal the parameter dependencies of the drag force. In Part II of this work we present an analytically based physical–mathematical model for rapidly calculating the drag force acting on a neuromast cupula. The cupula is well approximated as an immobile sphere located inside a tube-shaped canal segment of circular cross section containing a constant property fluid in a steady-periodic oscillating state of motion. The analytical expression derived for the dimensionless drag force is of the form , where | F N | is the amplitude of the drag force; | P L − P R | is the amplitude of the pressure difference driving the flow in the interpore tube segment; d / D is the ratio of sphere diameter to tube diameter; L t / D is the ratio of interpore tube segment length to tube diameter; and is the oscillating flow kinetic Reynolds number (a dimensionless frequency). Present results show that the dimensionless drag force amplitude increases with decreasing L t / D and maximizes in the range 0.65≤ d / D ≤0.85, depending on the values of L t / D and . It is also found that in the biologically relevant range of dimensionless frequencies 1≤ ≤20 and segment lengths 4≤ L t / D ≤16, the sphere tube (neuromast–canal) system acts as a low-pass filter for values d / D ≤0.75, approximately. For larger values of d / D the system is equally sensitive to all frequencies, but the drag force is significantly decreased. Comparisons with N–S calculations of the drag force show good agreement with the analytical model results. By revealing the parameter dependencies of the drag force, the model serves to guide biological understanding and the optimized design of corresponding bioinspired artificial sensors.
- 16 October 2008
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 6 (36) , 627-640
Drag force acting on a neuromast in the fish lateral line trunk canal. I. Numerical modelling of external–internal flow coupling
Fishes use a complex, multi-branched, mechanoreceptive organ called the lateral line to detect the motion of water in their immediate surroundings. This study is concerned with a subset of that organ referred to as the lateral line trunk canal (LLTC). The LLTC consists of a long tube no more than a few millimetres in diameter embedded immediately under the skin of the fish on each side of its body. In most fishes, pore-like openings are regularly distributed along the LLTC, and a minute sensor enveloped in a gelatinous cupula, referred to as a neuromast, is located between each pair of pores. Drag forces resulting from fluid motions induced inside the LLTC by pressure fluctuations in the external flow stimulate the neuromasts. This study, Part I of a two-part sequence, investigates the motion-sensing characteristics of the LLTC and how it may be used by fishes to detect wakes. To this end, an idealized geometrical/dynamical situation is examined that retains the essential problem physics. A two-level numerical model is developed that couples the vortical flow outside the LLTC to the flow stimulating the neuromasts within it. First, using a Navier–Stokes solver, we calculate the unsteady flow past an elongated rectangular prism and a fish downstream of it, with both objects moving at the same speed. By construction, the prism generates a clean, periodic vortex street in its wake. Then, also using the Navier–Stokes solver, the pressure field associated with this external flow is used to calculate the unsteady flow inside the LLTC of the fish, which creates the drag forces acting on the neuromast cupula. Although idealized, this external–internal coupled flow model allows an investigation of the filtering properties and performance characteristics of the LLTC for a range of frequencies of biological interest. The results obtained here and in Part II show that the LLTC acts as a low-pass filter, preferentially damping high-frequency pressure gradient oscillations, and hence high-frequency accelerations, associated with the external flow.
- 16 October 2008
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 6 (36) , 627-640
Drag force acting on a neuromast in the fish lateral line trunk canal. I. Numerical modelling of external–internal flow coupling
Fishes use a complex, multi-branched, mechanoreceptive organ called the lateral line to detect the motion of water in their immediate surroundings. This study is concerned with a subset of that organ referred to as the lateral line trunk canal (LLTC). The LLTC consists of a long tube no more than a few millimetres in diameter embedded immediately under the skin of the fish on each side of its body. In most fishes, pore-like openings are regularly distributed along the LLTC, and a minute sensor enveloped in a gelatinous cupula, referred to as a neuromast, is located between each pair of pores. Drag forces resulting from fluid motions induced inside the LLTC by pressure fluctuations in the external flow stimulate the neuromasts. This study, Part I of a two-part sequence, investigates the motion-sensing characteristics of the LLTC and how it may be used by fishes to detect wakes. To this end, an idealized geometrical/dynamical situation is examined that retains the essential problem physics. A two-level numerical model is developed that couples the vortical flow outside the LLTC to the flow stimulating the neuromasts within it. First, using a Navier–Stokes solver, we calculate the unsteady flow past an elongated rectangular prism and a fish downstream of it, with both objects moving at the same speed. By construction, the prism generates a clean, periodic vortex street in its wake. Then, also using the Navier–Stokes solver, the pressure field associated with this external flow is used to calculate the unsteady flow inside the LLTC of the fish, which creates the drag forces acting on the neuromast cupula. Although idealized, this external–internal coupled flow model allows an investigation of the filtering properties and performance characteristics of the LLTC for a range of frequencies of biological interest. The results obtained here and in Part II show that the LLTC acts as a low-pass filter, preferentially damping high-frequency pressure gradient oscillations, and hence high-frequency accelerations, associated with the external flow.
- 1 January 2008
- Published by Elsevier in Journal of Theoretical Biology
- Vol. 250 (1) , 194-208
Thermal energy conduction in a honey bee comb due to cell-heating bees
- 1 January 2008
- Published by Elsevier in Journal of Theoretical Biology
- Vol. 250 (1) , 194-208
Thermal energy conduction in a honey bee comb due to cell-heating bees
- Open Access
- 1 September 2007
- Published by The Company of Biologists in Journal of Experimental Biology
- Vol. 210 (17) , 2969-2978
Analytical and numerical investigation of the flow past the lateral antennular flagellum of the crayfishProcambarus clarkii
Analytical and numerical methodologies are combined to investigate the flow fields that approach and pass around the lateral flagellum of the crayfish Procambarus clarkii. Two cases are considered, the first being that of a free-flicking flagellum and the second corresponding to a flagellum fixed inside a small bore tube. The first case is the natural one while the second corresponds to the experimental configuration investigated by Mellon and Humphrey in the accompanying paper. In that study the authors observed a hydrodynamic-dependent asymmetry in the spiking responses recorded from single, bimodally sensitive local interneurons (Type I) in the crayfish deutocerebrum, whereby the direction of an abruptly initiated flow of freshwater (or odorant) past the flagellum resulted in consistently larger numbers of spikes in response to the hydrodynamic stimulation when the flow direction was proximal-to-distal. In this communication we show that the proximal-to-distal and the distal-to-proximal flows produced in the flagellum-in-tube experiment correspond closely to the flows associated with the downward and upward flicks, respectively, of a free-flicking flagellum. We also show from calculations of the drag forces acting on the putative mechanoreceptor sensilla circumferentially distributed around a free-flicking flagellum that there are at least three sources of hydrodynamic asymmetry possibly related to the electrophysiological asymmetry observed: (i) the sense of the drag forces acting on medial and lateral mechanoreceptors changes in the same way for both with change in flick direction; (ii) during a downward (an upward) flick, a ventral (dorsal) mechanoreceptor experiences a larger drag force magnitude than a dorsal (ventral) mechanoreceptor; (iii) because of the difference in speeds between downward and upward flicks, the magnitudes of the drag forces acting on medial, lateral and ventral mechanoreceptors during a downward flick are about two times larger relative to the forces acting on medial, lateral and dorsal mechanoreceptors during an upward flick. All three of these naturally occurring hydrodynamic asymmetries are correctly reproduced in the flagellum-in-tube experiment.
- 1 September 2007
- Published by The Company of Biologists in Journal of Experimental Biology
- Vol. 210 (17) , 2969-2978
Open AccessAnalytical and numerical investigation of the flow past the lateral antennular flagellum of the crayfishProcambarus clarkii
Analytical and numerical methodologies are combined to investigate the flow fields that approach and pass around the lateral flagellum of the crayfish Procambarus clarkii. Two cases are considered, the first being that of a free-flicking flagellum and the second corresponding to a flagellum fixed inside a small bore tube. The first case is the natural one while the second corresponds to the experimental configuration investigated by Mellon and Humphrey in the accompanying paper. In that study the authors observed a hydrodynamic-dependent asymmetry in the spiking responses recorded from single, bimodally sensitive local interneurons (Type I) in the crayfish deutocerebrum, whereby the direction of an abruptly initiated flow of freshwater (or odorant) past the flagellum resulted in consistently larger numbers of spikes in response to the hydrodynamic stimulation when the flow direction was proximal-to-distal. In this communication we show that the proximal-to-distal and the distal-to-proximal flows produced in the flagellum-in-tube experiment correspond closely to the flows associated with the downward and upward flicks, respectively, of a free-flicking flagellum. We also show from calculations of the drag forces acting on the putative mechanoreceptor sensilla circumferentially distributed around a free-flicking flagellum that there are at least three sources of hydrodynamic asymmetry possibly related to the electrophysiological asymmetry observed: (i) the sense of the drag forces acting on medial and lateral mechanoreceptors changes in the same way for both with change in flick direction; (ii) during a downward (an upward) flick, a ventral (dorsal) mechanoreceptor experiences a larger drag force magnitude than a dorsal (ventral) mechanoreceptor; (iii) because of the difference in speeds between downward and upward flicks, the magnitudes of the drag forces acting on medial, lateral and ventral mechanoreceptors during a downward flick are about two times larger relative to the forces acting on medial, lateral and dorsal mechanoreceptors during an upward flick. All three of these naturally occurring hydrodynamic asymmetries are correctly reproduced in the flagellum-in-tube experiment.
- 13 March 2006
- Published by ASME International in Journal of Fluids Engineering
- Vol. 128 (5) , 1090-1100
Experimental Study of the Flow in a Simulated Hard Disk Drive
Instantaneous circumferential and radial velocity components of the air flowing past a symmetrical pair of suspension/slider-units (SSUs) attached to an E-Block/arm were measured in a specially designed corotating disk apparatus simulating a hard disk drive (HDD) using the particle image velocimetry technique. The geometrical dimensions of the components in the apparatus test section were scaled up by a factor of two, approximately, relative to those of a nominal inch HDD. Most of the measurements were obtained on the interdisk midplane for two angular orientations of the arm/SSUs: (a) One with the tip of the SSUs near the hub supporting the disks; (b) another with the tip of the SSUs near the rims of the disks. Data obtained for disk rotational speeds ranging from to (corresponding to to , approximately, in a inch HDD) were post-processed to yield mean and rms values of the two velocity components and of the associated shear stress, the mean axial vorticity, and the turbulence intensity (based on the two velocity components). At the locations investigated near the arm/SSUs, and for disk rotational speeds larger than , the mean velocity components are found to be asymptotically independent of disk speed of rotation but their rms values appear to still be changing. At two locations and , respectively, upstream of the arm/SSUs, the flow approaching this obstruction displays features that can be attributed to the three-dimensional wake generated by the obstruction. Also, between these two locations and depending on the angular orientation of the arm/SSUs, the effect of the obstruction is to induce a three-dimensional region of flow reversal adjacent to the hub. Notwithstanding, the characteristics of the flow immediately upstream and downstream of the arm/SSUs appear to be determined by local flow-structure interactions. Aside from their intrinsic fundamental value, the data serve to guide and test the development of turbulence models and numerical calculation procedures for predicting this complex class of confined rotating flows, and to inform the improved design of HDDs.- 13 March 2006
- Published by ASME International in Journal of Fluids Engineering
- Vol. 128 (5) , 1090-1100
Experimental Study of the Flow in a Simulated Hard Disk Drive
Instantaneous circumferential and radial velocity components of the air flowing past a symmetrical pair of suspension/slider-units (SSUs) attached to an E-Block/arm were measured in a specially designed corotating disk apparatus simulating a hard disk drive (HDD) using the particle image velocimetry technique. The geometrical dimensions of the components in the apparatus test section were scaled up by a factor of two, approximately, relative to those of a nominal inch HDD. Most of the measurements were obtained on the interdisk midplane for two angular orientations of the arm/SSUs: (a) One with the tip of the SSUs near the hub supporting the disks; (b) another with the tip of the SSUs near the rims of the disks. Data obtained for disk rotational speeds ranging from to (corresponding to to , approximately, in a inch HDD) were post-processed to yield mean and rms values of the two velocity components and of the associated shear stress, the mean axial vorticity, and the turbulence intensity (based on the two velocity components). At the locations investigated near the arm/SSUs, and for disk rotational speeds larger than , the mean velocity components are found to be asymptotically independent of disk speed of rotation but their rms values appear to still be changing. At two locations and , respectively, upstream of the arm/SSUs, the flow approaching this obstruction displays features that can be attributed to the three-dimensional wake generated by the obstruction. Also, between these two locations and depending on the angular orientation of the arm/SSUs, the effect of the obstruction is to induce a three-dimensional region of flow reversal adjacent to the hub. Notwithstanding, the characteristics of the flow immediately upstream and downstream of the arm/SSUs appear to be determined by local flow-structure interactions. Aside from their intrinsic fundamental value, the data serve to guide and test the development of turbulence models and numerical calculation procedures for predicting this complex class of confined rotating flows, and to inform the improved design of HDDs.- 1 October 2003
- Published by Springer Nature in Microsystem Technologies
- Vol. 9 (8) , 534-540
Method for calculating the velocity of air flowing past a pair of suspensions in a disk drive
- 1 October 2003
- Published by Springer Nature in Microsystem Technologies
- Vol. 9 (8) , 534-540
Method for calculating the velocity of air flowing past a pair of suspensions in a disk drive