Weihong Guo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Weihong Guo has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
Feng Huang
Advanced concept development, Invivo corporation
1 shared publicationQingguo Zeng
Department of Mathematics, University of FloridaPO Box 118105, Gainesville, FL 32611, USA
1 shared publicationYunmei Chen
Department of Mathematics, University of FloridaPO Box 118105, Gainesville, FL 32611, USA
1 shared publication
Latest Publications
- 15 April 2008
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 366 (1874) , 2279-2292
A geometric flow-based approach for diffusion tensor image segmentation
Diffusion tensor magnetic resonance imaging (DT-MRI, shortened as DTI) produces, from a set of diffusion-weighted magnetic resonance images, tensor-valued images where each voxel is assigned a 3×3 symmetric, positive-definite matrix. This tensor is simply the covariance matrix of a local Gaussian process with zero mean, modelling the average motion of water molecules. We propose a three-dimensional geometric flow-based model to segment the main core of cerebral white matter fibre tracts from DTI. The segmentation is carried out with a front propagation algorithm. The front is a three-dimensional surface that evolves along its normal direction with speed that is proportional to a linear combination of two measures: a similarity measure and a consistency measure. The similarity measure computes the similarity of the diffusion tensors at a voxel and its neighbouring voxels along the normal to the front; the consistency measure is able to speed up the propagation at locations where the evolving front is more consistent with the diffusion tensor field, to remove noise effect to some extent, and thus to improve results. We validate the proposed model and compare it with some other methods using synthetic and human brain DTI data; experimental results indicate that the proposed model improves the accuracy and efficiency in segmentation.
- 15 April 2008
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 366 (1874) , 2279-2292
A geometric flow-based approach for diffusion tensor image segmentation
Diffusion tensor magnetic resonance imaging (DT-MRI, shortened as DTI) produces, from a set of diffusion-weighted magnetic resonance images, tensor-valued images where each voxel is assigned a 3×3 symmetric, positive-definite matrix. This tensor is simply the covariance matrix of a local Gaussian process with zero mean, modelling the average motion of water molecules. We propose a three-dimensional geometric flow-based model to segment the main core of cerebral white matter fibre tracts from DTI. The segmentation is carried out with a front propagation algorithm. The front is a three-dimensional surface that evolves along its normal direction with speed that is proportional to a linear combination of two measures: a similarity measure and a consistency measure. The similarity measure computes the similarity of the diffusion tensors at a voxel and its neighbouring voxels along the normal to the front; the consistency measure is able to speed up the propagation at locations where the evolving front is more consistent with the diffusion tensor field, to remove noise effect to some extent, and thus to improve results. We validate the proposed model and compare it with some other methods using synthetic and human brain DTI data; experimental results indicate that the proposed model improves the accuracy and efficiency in segmentation.
- 1 January 2008
- Published by Springer Nature
- Vol. 11, 939-947
A Local Mutual Information Guided Denoising Technique and Its Application to Self-calibrated Partially Parallel Imaging
The application of Partially Parallel Imaging (PPI) techniques to regular clinical Magnetic Resonance Imaging (MRI) studies has brought about the benefit of significantly faster acquisitions but at the cost of amplified and spatially variant noise, especially, for high parallel imaging acceleration rates. A Local Mutual Information (LMI) weighted Total Variation (TV) based model is proposed to remove non-evenly distributed noise while preserving image sharpness. For self-calibrated PPI, such as GeneRalized Auto-calibration Partially Parallel Acquisition (GRAPPA) and modified SENSitivity Encoding (mSENSE), a low spatial resolution high Signal to Noise Ratio (SNR) image is available besides the reconstructed high spatial resolution low SNR image. The LMI between these two images is used to detect the noise distribution and the location of edges automatically, and is then applied as guidance for denoising. To better preserve sharpness, Bregman iteration scheme is utilized to add the removed signal back to the denoised image. Entropy of the residual map is used to automatically terminate iteration without using any information of the golden standard or real noise. Results of the proposed algorithm on synthetic and in vivo MR images indicate that the proposed technique preserves image edges and suppresses noise well in the images reconstructed by GRAPPA. The comparison with some existing techniques further confirms the advantages. This algorithm can be applied to enhance the clinical applicability of self-calibrated PPI. Potentially, it can be extended to denoise general images with spatially variant noise.
- 1 January 2008
- Published by Springer Nature
- Vol. 11, 939-947
A Local Mutual Information Guided Denoising Technique and Its Application to Self-calibrated Partially Parallel Imaging
The application of Partially Parallel Imaging (PPI) techniques to regular clinical Magnetic Resonance Imaging (MRI) studies has brought about the benefit of significantly faster acquisitions but at the cost of amplified and spatially variant noise, especially, for high parallel imaging acceleration rates. A Local Mutual Information (LMI) weighted Total Variation (TV) based model is proposed to remove non-evenly distributed noise while preserving image sharpness. For self-calibrated PPI, such as GeneRalized Auto-calibration Partially Parallel Acquisition (GRAPPA) and modified SENSitivity Encoding (mSENSE), a low spatial resolution high Signal to Noise Ratio (SNR) image is available besides the reconstructed high spatial resolution low SNR image. The LMI between these two images is used to detect the noise distribution and the location of edges automatically, and is then applied as guidance for denoising. To better preserve sharpness, Bregman iteration scheme is utilized to add the removed signal back to the denoised image. Entropy of the residual map is used to automatically terminate iteration without using any information of the golden standard or real noise. Results of the proposed algorithm on synthetic and in vivo MR images indicate that the proposed technique preserves image edges and suppresses noise well in the images reconstructed by GRAPPA. The comparison with some existing techniques further confirms the advantages. This algorithm can be applied to enhance the clinical applicability of self-calibrated PPI. Potentially, it can be extended to denoise general images with spatially variant noise.