Michael Kaszuba
Research Subjects
Michael Kaszuba has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Andrew Jones
Malvern Instruments Ltd, Grovewood Road, Enigma Business Park, Malvern, Worcestershire WR14 1XZ, UK
1 shared publicationDavid McKnight
Malvern Instruments Ltd, Worcestershire, UK
1 shared publication- Fanny Caputo
JOLIOT, Université Paris-Saclay, CEA
1 shared publication Fraser K. McNeil-Watson
Malvern Instruments Ltd, Worcestershire, UK
1 shared publicationFraser Mcneil Watson
Malvern Instruments Ltd, Grovewood Road, Enigma Business Park, Malvern, Worcestershire WR14 1XZ, UK
1 shared publication- Hanna Jankevics-Jones
Malvern Panalytical Ltd., Enigma Business Park, Grovewood Road, Malvern, Worcestershire WR14 1XZ, UK
1 shared publication
Latest Publications
- Open Access
Biophysical Characterization of Viral and Lipid-Based Vectors for Vaccines and Therapeutics with Light Scattering and Calorimetric Techniques
Novel vaccine platforms for delivery of nucleic acids based on viral and non-viral vectors, such as recombinant adeno associated viruses (rAAV) and lipid-based nanoparticles (LNPs), hold great promise. However, they pose significant manufacturing and analytical challenges due to their intrinsic structural complexity. During product development and process control, their design, characterization, and quality control require the combination of fit-for-purpose complementary analytical tools. Moreover, an in-depth methodological expertise and holistic approach to data analysis are required for robust measurements and to enable an adequate interpretation of experimental findings. Here the combination of complementary label-free biophysical techniques, including dynamic light scattering (DLS), multiangle-DLS (MADLS), Electrophoretic Light Scattering (ELS), nanoparticle tracking analysis (NTA), multiple detection SEC and differential scanning calorimetry (DSC), have been successfully used for the characterization of physical and chemical attributes of rAAV and LNPs encapsulating mRNA. Methods’ performance, applicability, dynamic range of detection and method optimization are discussed for the measurements of multiple critical physical−chemical quality attributes, including particle size distribution, aggregation propensity, polydispersity, particle concentration, particle structural properties and nucleic acid payload.
Open AccessBiophysical Characterization of Viral and Lipid-Based Vectors for Vaccines and Therapeutics with Light Scattering and Calorimetric Techniques
Novel vaccine platforms for delivery of nucleic acids based on viral and non-viral vectors, such as recombinant adeno associated viruses (rAAV) and lipid-based nanoparticles (LNPs), hold great promise. However, they pose significant manufacturing and analytical challenges due to their intrinsic structural complexity. During product development and process control, their design, characterization, and quality control require the combination of fit-for-purpose complementary analytical tools. Moreover, an in-depth methodological expertise and holistic approach to data analysis are required for robust measurements and to enable an adequate interpretation of experimental findings. Here the combination of complementary label-free biophysical techniques, including dynamic light scattering (DLS), multiangle-DLS (MADLS), Electrophoretic Light Scattering (ELS), nanoparticle tracking analysis (NTA), multiple detection SEC and differential scanning calorimetry (DSC), have been successfully used for the characterization of physical and chemical attributes of rAAV and LNPs encapsulating mRNA. Methods’ performance, applicability, dynamic range of detection and method optimization are discussed for the measurements of multiple critical physical−chemical quality attributes, including particle size distribution, aggregation propensity, polydispersity, particle concentration, particle structural properties and nucleic acid payload.
- Open Access
- 28 September 2010
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 368 (1927) , 4439-4451
High-concentration zeta potential measurements using light-scattering techniques
Zeta potential is the key parameter that controls electrostatic interactions in particle dispersions. Laser Doppler electrophoresis is an accepted method for the measurement of particle electrophoretic mobility and hence zeta potential of dispersions of colloidal size materials. Traditionally, samples measured by this technique have to be optically transparent. Therefore, depending upon the size and optical properties of the particles, many samples will be too concentrated and will require dilution. The ability to measure samples at or close to their neat concentration would be desirable as it would minimize any changes in the zeta potential of the sample owing to dilution. However, the ability to measure turbid samples using light-scattering techniques presents a number of challenges. This paper discusses electrophoretic mobility measurements made on turbid samples at high concentration using a novel cell with reduced path length. Results are presented on two different sample types, titanium dioxide and a polyurethane dispersion, as a function of sample concentration. For both of the sample types studied, the electrophoretic mobility results show a gradual decrease as the sample concentration increases and the possible reasons for these observations are discussed. Further, a comparison of the data against theoretical models is presented and discussed. Conclusions and recommendations are made from the zeta potential values obtained at high concentrations.
- 28 September 2010
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 368 (1927) , 4439-4451
Open AccessHigh-concentration zeta potential measurements using light-scattering techniques
Zeta potential is the key parameter that controls electrostatic interactions in particle dispersions. Laser Doppler electrophoresis is an accepted method for the measurement of particle electrophoretic mobility and hence zeta potential of dispersions of colloidal size materials. Traditionally, samples measured by this technique have to be optically transparent. Therefore, depending upon the size and optical properties of the particles, many samples will be too concentrated and will require dilution. The ability to measure samples at or close to their neat concentration would be desirable as it would minimize any changes in the zeta potential of the sample owing to dilution. However, the ability to measure turbid samples using light-scattering techniques presents a number of challenges. This paper discusses electrophoretic mobility measurements made on turbid samples at high concentration using a novel cell with reduced path length. Results are presented on two different sample types, titanium dioxide and a polyurethane dispersion, as a function of sample concentration. For both of the sample types studied, the electrophoretic mobility results show a gradual decrease as the sample concentration increases and the possible reasons for these observations are discussed. Further, a comparison of the data against theoretical models is presented and discussed. Conclusions and recommendations are made from the zeta potential values obtained at high concentrations.
- 22 July 2008
- Published by Springer Nature in Journal of Nanoparticle Research
- Vol. 10 (S1) , 269-270
Response to the Letter to the Editor
- 22 July 2008
- Published by Springer Nature in Journal of Nanoparticle Research
- Vol. 10 (S1) , 269-270
Response to the Letter to the Editor
- Open Access
- 26 October 2007
- Published by Springer Nature in Journal of Nanoparticle Research
- Vol. 10 (5) , 823-829
Measuring sub nanometre sizes using dynamic light scattering
- 26 October 2007
- Published by Springer Nature in Journal of Nanoparticle Research
- Vol. 10 (5) , 823-829
Open AccessMeasuring sub nanometre sizes using dynamic light scattering