JLJ. Adam Law

J. Adam Law

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


J. Adam Law has a total of 98 co-authors. Here are the top co-authors by number of shared publications:

  • George Kovacs

    Department of Medical Neuroscience, Dalhousie University, Halifax, Canada

    7 shared publications
  • Andrew D. Milne

    Department of Anesthesia, Pain Management & Perioperative Medicine, QEII Health Sciences Centre, Halifax Infirmary Site, Dalhousie University, Halifax, Canada

    6 shared publications
  • Ian R. Morris

    Dalhousie University, QEII Health Sciences Centre

    6 shared publications
  • David T. Wong

    Department of Anesthesia, Toronto Western Hospital, University Health Network, University of Toronto, Toronto, Canada

    4 shared publications
  • Laura V. Duggan

    Department of Anesthesiology and Pain Medicine, The Ottawa Hospital Civic Campus, University of Ottawa, Ottawa, Canada

    4 shared publications
  • Orlando R. Hung

    Department of Anesthesia, Pain Management and Perioperative Medicine, QEII Health Sciences Centre, Dalhousie University, Halifax, Canada

    4 shared publications

Latest Publications

  • Top Cited Papers

    Tracheal intubation in critically ill adults with a physiologically difficult airway. An international Delphi study

    by Kunal Karamchandani, Prashant Nasa, Mary Jarzebowski, David J. Brewster, Audrey De Jong, Philippe R. Bauer, Lauren Berkow, Calvin A. Brown, Luca Cabrini, Jonathan Casey, et al.

    Purpose Our study aimed to provide consensus and expert clinical practice statements related to airway management in critically ill adults with a physiologically difficult airway (PDA). Methods An international Steering Committee involving seven intensivists and one Delphi methodology expert was convened by the Society of Critical Care Anaesthesiologists (SOCCA) Physiologically Difficult Airway Task Force. The committee selected an international panel of 35 expert clinician–researchers with expertise in airway management in critically ill adults. A Delphi process based on an iterative approach was used to obtain the final consensus statements. Results The Delphi process included seven survey rounds. A stable consensus was achieved for 53 (87%) out of 61 statements. The experts agreed that in addition to pathophysiological conditions, physiological alterations associated with pregnancy and obesity also constitute a physiologically difficult airway. They suggested having an intubation team consisting of at least three healthcare providers including two airway operators, implementing an appropriately designed checklist, and optimizing hemodynamics prior to tracheal intubation. Similarly, the experts agreed on the head elevated laryngoscopic position, routine use of videolaryngoscopy during the first attempt, preoxygenation with non-invasive ventilation, careful mask ventilation during the apneic phase, and attention to cardiorespiratory status for post-intubation care. Conclusion Using a Delphi method, agreement among a panel of international experts was reached for 53 statements providing guidance to clinicians worldwide on safe tracheal intubation practices in patients with a physiologically difficult airway to help improve patient outcomes. Well-designed studies are needed to assess the effects of these practice statements and address the remaining uncertainties.


  • The incidence of awake tracheal intubation in anesthetic practice is decreasing: a historical cohort study of the years 2014–2020 at a single tertiary care institution

    by J. Adam Law, Apiraami Thana, Andrew D. Milne

    Purpose Awake tracheal intubation (ATI) is recommended in airway management guidelines when significant difficulty is predicted with airway management. Use of the technique may be declining, which may have implications for patient safety or for skills acquisition and maintenance. This historical cohort database study sought to determine if the use of ATI was decreasing in our adult tertiary care center. Methods With institutional research ethics board approval, we queried our anesthesia information management system for cases with ATI descriptors for each year from 2014 to 2020. Records of the retrieved cases were independently reviewed by all three authors to verify they met inclusion criteria for the ATI cohort prior to analysis for the primary outcome. Secondary outcome measures included airway device and route used for ATI, first attempt and ultimate success rates, and reported adverse issues recorded in cases of failed ATI or those requiring more than one attempt. Results A total of 692 cases of ATI were identified between 2014 and 2020. There was a statistically significant decrease in yearly ATIs over the seven-year study period (Chi square goodness of fit, P < 0.001), with ATI use decreasing by about 50%. First attempt success was significantly greater with use of flexible bronchoscopy vs video laryngoscopy to facilitate ATI (84% vs 60%; P < 0.001), while there was no difference in first attempt success with the oral vs nasal route (82% vs 82%; P = 1.0). Conclusion In this single-center historical cohort study, the use of ATI decreased significantly from 2014 to 2020. Whether this decrease will result in morbidity or mortality related to airway management is currently unclear. Regardless, it has implications for training opportunities and maintenance of competence in performing the procedure.


  • An in vitro assessment of light intensity provided during direct laryngeal visualization by videolaryngoscopes with Macintosh geometry blades

    by Madeleine Harlow, George Kovacs, Paul Brousseau, J. Adam Law

    Background Adequate illumination of the larynx is needed during laryngoscopy to facilitate tracheal intubation. The International Organization for Standardization (ISO) has established a minimum light intensity for direct laryngoscopy (DL) of over 500 lux for at least ten minutes, but no such standard exists for Macintosh geometry videolaryngoscope (Mac-VL) blades, which allow for both direct or indirect (videoscopic) viewing of the larynx. Using in situ bench and in vitro testing in a human cadaver, we determined illumination and luminance values delivered by various Mac-VLs and compared these with published minimum lighting benchmarks as well as a reference direct laryngoscope. Methods We tested six Mac-VLs (i-view™, McGRATH™ MAC, GlideScope® Spectrum™ [single-use] DVM S4, GlideScope® Titanium [reusable] Mac T4, C-MAC® S [single-use] Macintosh #4, C-MAC® [reusable] Macintosh #4) together with one direct laryngoscope (Heine LED). Each laryngoscope was assessed with three measurements, as follows: part 1: illuminance (lux) was measured in situ using a purpose-designed benchtop light intensity measurement apparatus; part 2: luminance (light reflected back to the eye) was measured (in candela m-2 [cd·m−2]) during videolaryngoscopy (VL) and DL in a human cadaver using a spot meter pointed at the interarytenoid notch; part 3: illuminance (lux) was measured during VL and DL in a human cadaver using a light meter surgically implanted just proximal to the vocal cords. Results Illuminance and luminance varied significantly among the Mac-VLs. Mean (standard devitation) illuminance among the six tested Mac-VLs ranged from 117 (11) to 2,626 (42) lux in the measurement apparatus and from 228 (11) to 2,900 (374) lux by the surgically implanted light meter in the cadaver. All values were less than the reference Heine direct laryngoscope and some fell below the published ISO standard of 500 lux for DL. Luminance testing by spot meter had a similarly wide range, varying from 3.78 (0.60) to 49.1 (10.4) cd·m−2, with some Mac-VLs delivering less luminance than the reference Heine direct laryngoscope. Conclusions Our results indicate that illuminance and luminance provided by Mac-VLs used for direct laryngeal viewing varies substantially between devices, with some falling below standards previously suggested as the minimum required for DL. While this may have no implications for the quality of image visible on a device’s video monitor, the clinician should be aware that when Mac-VLs are used for direct viewing of the larynx, lighting may not be optimal. This might adversely affect ease or success of tracheal intubation.


  • Top Cited Papers
    Open Access

    Canadian Airway Focus Group updated consensus-based recommendations for management of the difficult airway: part 1. Difficult airway management encountered in an unconscious patient

    by J. Adam Law, Laura V. Duggan, Mathieu Asselin, Paul Baker, Edward Crosby, Andrew Downey, Orlando R. Hung, Philip M. Jones, François Lemay, Rudiger Noppens, et al.

    Purpose Since the last Canadian Airway Focus Group (CAFG) guidelines were published in 2013, the literature on airway management has expanded substantially. The CAFG therefore re-convened to examine this literature and update practice recommendations. This first of two articles addresses difficulty encountered with airway management in an unconscious patient. Source Canadian Airway Focus Group members, including anesthesia, emergency medicine, and critical care physicians, were assigned topics to search. Searches were run in the Medline, EMBASE, Cochrane Central Register of Controlled Trials, and CINAHL databases. Results were presented to the group and discussed during video conferences every two weeks from April 2018 to July 2020. These CAFG recommendations are based on the best available published evidence. Where high-quality evidence was lacking, statements are based on group consensus. Findings and key recommendations Most studies comparing video laryngoscopy (VL) with direct laryngoscopy indicate a higher first attempt and overall success rate with VL, and lower complication rates. Thus, resources allowing, the CAFG now recommends use of VL with appropriately selected blade type to facilitate all tracheal intubations. If a first attempt at tracheal intubation or supraglottic airway (SGA) placement is unsuccessful, further attempts can be made as long as patient ventilation and oxygenation is maintained. Nevertheless, total attempts should be limited (to three or fewer) before declaring failure and pausing to consider “exit strategy” options. For failed intubation, exit strategy options in the still-oxygenated patient include awakening (if feasible), temporizing with an SGA, a single further attempt at tracheal intubation using a different technique, or front-of-neck airway access (FONA). Failure of tracheal intubation, face-mask ventilation, and SGA ventilation together with current or imminent hypoxemia defines a “cannot ventilate, cannot oxygenate” emergency. Neuromuscular blockade should be confirmed or established, and a single final attempt at face-mask ventilation, SGA placement, or tracheal intubation with hyper-angulated blade VL can be made, if it had not already been attempted. If ventilation remains impossible, emergency FONA should occur without delay using a scalpel-bougie-tube technique (in the adult patient). The CAFG recommends all institutions designate an individual as “airway lead” to help institute difficult airway protocols, ensure adequate training and equipment, and help with airway-related quality reviews.


  • Top Cited Papers
    Open Access

    Canadian Airway Focus Group updated consensus-based recommendations for management of the difficult airway: part 2. Planning and implementing safe management of the patient with an anticipated difficult airway

    by J. Adam Law, Laura V. Duggan, Mathieu Asselin, Paul Baker, Edward Crosby, Andrew Downey, Orlando R. Hung, George Kovacs, François Lemay, Rudiger Noppens, et al.

    Purpose Since the last Canadian Airway Focus Group (CAFG) guidelines were published in 2013, the published airway management literature has expanded substantially. The CAFG therefore re-convened to examine this literature and update practice recommendations. This second of two articles addresses airway evaluation, decision-making, and safe implementation of an airway management strategy when difficulty is anticipated. Source Canadian Airway Focus Group members, including anesthesia, emergency medicine, and critical care physicians were assigned topics to search. Searches were run in the Medline, EMBASE, Cochrane Central Register of Controlled Trials, and CINAHL databases. Results were presented to the group and discussed during video conferences every two weeks from April 2018 to July 2020. These CAFG recommendations are based on the best available published evidence. Where high-quality evidence is lacking, statements are based on group consensus. Findings and key recommendations Prior to airway management, a documented strategy should be formulated for every patient, based on airway evaluation. Bedside examination should seek predictors of difficulty with face-mask ventilation (FMV), tracheal intubation using video- or direct laryngoscopy (VL or DL), supraglottic airway use, as well as emergency front of neck airway access. Patient physiology and contextual issues should also be assessed. Predicted difficulty should prompt careful decision-making on how most safely to proceed with airway management. Awake tracheal intubation may provide an extra margin of safety when impossible VL or DL is predicted, when difficulty is predicted with more than one mode of airway management (e.g., tracheal intubation and FMV), or when predicted difficulty coincides with significant physiologic or contextual issues. If managing the patient after the induction of general anesthesia despite predicted difficulty, team briefing should include triggers for moving from one technique to the next, expert assistance should be sourced, and required equipment should be present. Unanticipated difficulty with airway management can always occur, so the airway manager should have a strategy for difficulty occurring in every patient, and the institution must make difficult airway equipment readily available. Tracheal extubation of the at-risk patient must also be carefully planned, including assessment of the patient’s tolerance for withdrawal of airway support and whether re-intubation might be difficult.