ALAlex H. Lumpkin

Alex H. Lumpkin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Alex H. Lumpkin has a total of 103 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Near-infrared noise in intense electron bunches

    by Sergei Kladov, Sergei Nagaitsev, Young-Kee Kim, Daniel R. Broemmelsiek, Zhirong Huang, Jonathan Jarvis, Alex H. Lumpkin, Jinhao Ruan, Andrea Saewert, Randy M. Thurman-Keup

    This article investigates electron bunch density fluctuations in the 1 − 10 μ m wavelength range, focusing on their impact on coherent electron cooling (CEC) in hadron storage rings. In this study, we compare the shot-noise model with experimental observations using bandwidth-filtered near-infrared optical transition radiation (OTR) photodiode signals, where the transverse bunch size is much larger than the OTR wavelength of interest. The relativistic electron bunch ( γ ≈ 50 ) parameters are close to those proposed for the coherent electron cooler in the electron-ion collider (EIC) project. Preliminary feasibility experiments were conducted, and the noise factors are presented, supported by particle tracking. No major density fluctuations or effective cooling rate decrease were revealed for EIC CEC design parameters. Additionally, longitudinal-space-charge-induced microbunching for the chicane-compressed bunch was observed with coherent OTR enhancements up to 100 times, providing further calibration of the measurement method.

  • Near-Infrared noise in intense electron bunches

    by Sergei Kladov, Daniel Broemmelsiek, Zhirong Huang, Jonathan Jarvis, Young-Kee Kim, Alex Lumpkin, Sergei Nagaitsev, Jinhao Ruan, Andrea Saewert, Randy Thurman-Keup

  • Open Access

    FAST Low-Energy Beamline Studies: Toward High-Peak 5D Brightness Beams for FAST-GREENS

    by Frederick Cropp, Jinhao Ruan, James Santucci, Daniel MacLean, Alex H. Lumpkin, Christopher C. Hall, Jonathan P. Edelen, Alex Murokh, Daniel Broemmelsiek, Pietro Musumeci

    The FAST beamline is the injector for the planned Gamma-Ray Electron ENhanced Source (GREENS) program, which aims to achieve the demonstration and first application of a high-efficiency, high-average-power free-electron laser at 515 nm. FAST-GREENS requires high 5D peak brightness; transverse normalized projected emittances of 3 mm-mrad and a peak current of 600 A are the minimum beam requirements for the FEL to reach the 10% efficiency goal. In this work, studies of the low-energy section of the FAST beamline are presented toward these ends, including preliminary measurements of beam compression and beam emittance. An effort toward developing a high-fidelity simulation model that could be later optimized for FAST-GREENS is presented.

  • Open Access

    Wakefields In Superconducting RF Cavities and The Impact on VUV Free-electron Laser Oscillator Performance

    by Alex H. Lumpkin, Henry P. Freund, Matthias Reinsch, Peter J. M. van der Slot

    The Fermilab Accelerator Science and Technology (FAST) facility is currently in operation with its linac based on TESLA-type superconducting rf cavities. Using a 3-MHz micropulse repetition rate with a long macropulse composed of up to 3000 micropulses, and with beam energies demonstrated at 300 MeV and projected to reach 800 MeV with two additional cryomodules, the feasibilities for a vacuum ultraviolet (VUV) and an extreme ultraviolet (EUV) free-electron laser oscillator (FELO) with the two energies are evaluated. We have used both the GINGER code with an oscillator module and the MINERVA/OPC code to assess FELO saturation prospects at 120 nm with a 5.0-cm-period undulator of 4.5-m length and the MINERVA/OPC code to assess the FELO at 13.4 nm with adjusted parameters. The simulation results support saturation at both of these wavelengths which are much shorter than the demonstrated shortest wavelength record of 168.6 nm from a storage-ring-based FELO. This indicates superconducting rf linac-driven FELOs can be extended into this VUV-EUV wavelength regime previously only reached with single-pass FEL configurations. In addition, emittance-dilution effects due to wakefields in the cavities and the resulting sub-macropulse centroid slew effects on FELO performance are addressed using MINERVA/OPC simulations for the first time.

  • Open Access

    Wakefields in superconducting rf cavities and the impact on vacuum ultraviolet free-electron laser oscillator performance

    by Alex H. Lumpkin, Henry P. Freund, Matthias Reinsch, Peter J. M. van der Slot

    The Fermilab Accelerator Science and Technology facility is currently in operation with its linac based on TESLA-type superconducting rf cavities. Using a 3-MHz micropulse repetition rate with a long macropulse composed of up to 3000 micropulses, and with beam energies demonstrated at 300 MeV and projected to reach 800 MeV with two additional cryomodules, the feasibilities for a vacuum ultraviolet (VUV) and an extreme ultraviolet (EUV) free-electron laser oscillator (FELO) with the two energies are evaluated. We have used both the ginger code with an oscillator module and the minerva/opc code to assess FELO saturation prospects at 120 nm with a 5.0-cm-period undulator of 4.5-m length and the minerva/opc code to assess the FELO at 13.4 nm with adjusted parameters. The simulation results support saturation at both of these wavelengths which are much shorter than the demonstrated shortest wavelength record of 168.6 nm from a storage-ring-based FELO. This indicates superconducting rf linac-driven FELOs can be extended into this VUV-EUV wavelength regime previously only reached with single-pass FEL configurations. In addition, emittance-dilution effects due to wakefields in the cavities and the resulting submacropulse centroid slew effects on FELO performance are addressed using minerva/opc simulations for the first time.


  • Open Access

    Submacropulse electron-beam dynamics correlated with higher-order modes in a Tesla-type cryomodule

    by A. H. Lumpkin, R. Thurman-Keup, D. Edstrom, P. Prieto, J. Ruan, B. Jacobson, J. Sikora, J. Diaz-Cruz, A. Edelen, F. Zhou

    Experiments were performed at the Fermilab Accelerator Science and Technology facility to elucidate the effects of long-range wakefields in TESLA-type superconducting rf cavities. In particular, we investigated the higher-order modes (HOMs) generated in the eight, nine-cell cavities of a cryomodule (CM) due to off-axis steering with correctors located ∼4  m upstream of the CM. We have observed correlated submacropulse centroid slews of a few hundred microns and centroid oscillations at ∼240  kHz in the rf beam-position-monitor data after the CM. The entrance energy into the CM was 25 MeV, and the exit energy was 100 MeV with 125  pC/bunch and 400  pC/bunch in 50-bunch pulse trains. These experimental results were evaluated for machine learning training aspects which will be used to inform the commissioning plan for the Linac Coherent Light Source-II injector CM. With an entrance beam energy of <1  MeV in this case (or for ∼6  MeV at the European X-ray Free-electron Laser injector), the HOM-effect mitigation would be particularly critical.


  • Open Access

    Collimator irradiation studies in the Argonne Advanced Photon Source at energy densities expected in next-generation storage ring light sources

    by J. Dooling, M. Borland, W. Berg, J. Calvey, G. Decker, L. Emery, K. Harkay, R. Lindberg, G. Navrotksi, V. Sajaev, et al.

    The Advanced Photon Source (APS) team is building a fourth-generation storage ring (4GSR), replacing the present double-bend achromat lattice with a multibend achromat system thereby allowing the production of ultrabright x-ray beams. The new lattice enables a 2-order-of-magnitude reduction in horizontal beam emittance and a factor of two increase in beam current. The result is an electron beam of very high energy and power densities. Initial predictions suggest many common ultrahigh-vacuum-compatible materials struck by the full-intensity electron beam will be damaged. Two experimental beam abort studies have been conducted on collimator test pieces in the present APS SR to inform the design of a fully-functional machine protection system for APS 4GSR operations at 200 mA. A comprehensive suite of diagnostics was utilized during the studies. The diagnostics used in these experiments are not new, but employed in different ways to obtain unique data sets. With these sets now in hand, we are developing new numerical tools to guide collimator design using pelegant [M. Borland, elegant: A flexible SDDS-compliant code for accelerator simulation, Technical Report No. LS-287, Advanced Photon Source, 2000; Y. Wang and M. Borland, Implementation and performance of parallelized elegant, in Proceedings of the 2007 Particle Accelerator Conference, http://cern.ch/AccelConf/p07/PAPERS/THPAN095.PDF, pp. 3444–3446], mars [N. V. Mokhov and S. I. Striganov, Fermilab-conf-07/008-ad, AIP Conf. Proc. 896, 50 (2007)], and flash [B. Fryxell et al., flash: An adaptive mesh hydrodynamics code for modeling astrophysical thermonuclear flashes, Astrophys. J. Suppl. Ser. 131, 273 (2000); P. Tzeferacos et al., Laboratory evidence of dynamo amplification of magnetic fields in a turbulent plasma, Nat. Commun. 9, 591 (2018)].


  • Open Access

    High-resolution longitudinal profile diagnostics for ultralow charges stored in a ring

    by Alex H. Lumpkin, Kent P. Wootton

    Observations of optical synchrotron radiation emitted over millions of passes from a few electrons circulating in the particle accumulator ring at the Advanced Photon Source were performed with a digital CMOS camera and a synchroscan streak camera operating at 117.3 MHz. Discrete changes of integrated counts in the CMOS image region of interest are ascribed to single electron steps in a 10-s sensor integration time. Circulations of a single electron at 375 and at 425 MeV were demonstrated in the 12-bit digital CMOS camera images. The streak camera operating at the 12th harmonic of the fundamental revolution frequency at 9.77 MHz was used to measure the bunch length from 0.5-nC circulating charge down to tens of electrons or <10  aC. The measurements were performed with ∼8−ps temporal resolution uniquely at such ultralow charges. These results also serve as a proof-of-principle longitudinal profile diagnostic for the predicted effects of optical stochastic cooling at low charge in commissioning experiments at the Fermilab Integrable Optics Test Accelerator ring.


  • Open Access

    Submicropulse electron-beam dynamics correlated with short-range wakefields in Tesla-type superconducting rf cavities

    by A. H. Lumpkin, R. M. Thurman-Keup, D. Edstrom, J. Ruan

    We report direct observations of submicropulse beam centroid shifts (head-tail kicks) correlated with short-range wakefields generated by off-axis electron-beam steering in Tesla-type superconducting rf cavities. The experiments were performed at the Fermilab Accelerator Science and Technology (FAST) Facility using its unique configuration of a photocathode rf gun injecting beam into two separated nine-cell cavities. The cavities are in series with corrector magnets and beam position monitors (BPMs) located before, between, and after them. The off-axis steering in the cavity was guided by the rf BPM data and higher-order mode circuitry targeting the first and second dipole passbands. The centroid shifts of up to 300  μm from head to tail of the ∼10−ps-long micropulses at 500  pC/b in a 3-MHz pulse train were measured via optical transition radiation at a downstream screen with a Hamamatsu C5680 synchroscan streak camera. We also showed that we could compensate such kicks from the first cavity with the short-range wakefields (SRWs) in the second cavity, and we observed the dilution of the beam size in the tail of the pulses. A simple numerical model of the SRW effect in a single Tesla cavity is compared to the experiment successfully. In principle, these fundamental results may be scaled to cryomodule configurations of major free-electron laser (FEL) facilities such as the European XFEL, Linac Coherent Light Source or LCLS-II XFEL, and the conceptual international linear collider.


  • Open Access

    Submacropulse electron-beam dynamics correlated with higher-order modes in Tesla-type superconducting rf cavities

    by A. H. Lumpkin, R. Thurman-Keup, D. Edstrom, J. Ruan, N. Eddy, P. Prieto, O. Napoly, B. E. Carlsten, K. Bishofberger

    We report the direct observations of submacropulse beam centroid oscillations correlated with higher order modes (HOMs) which were generated by off-axis electron beam steering in TESLA-type superconducting rf cavities. The experiments were performed at the Fermilab Accelerator Science and Technology (FAST) facility using its unique configuration of a photocathode rf gun injecting beam into two separated nine-cell cavities in series with corrector magnets and beam position monitors (BPMs) located before, between, and after them. Oscillations of ∼100  kHz in the vertical plane and ∼380  kHz in the horizontal plane with up to 600−μm amplitudes were observed in a 3-MHz micropulse repetition rate beam with charges of 100, 300, 500, and 1000  pC/b. However, the effects were much reduced at 100  pC/b. The measurements were based on HOM detector circuitry targeting the first and second dipole passbands, rf BPM bunch-by-bunch array data, imaging cameras, and a framing camera. Calculations reproduced the oscillation frequencies of the phenomena in the vertical case. In principle, these fundamental results may be scaled to cryomodule configurations of major accelerator facilities.