SEShigeru Ehara

Shigeru Ehara

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shigeru Ehara has a total of 101 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Selection of peripheral intravenous catheters with 24-gauge side-holes versus those with 22-gauge end-hole for MDCT: A prospective randomized study

    by Akio Tamura, Kenichi Kato, Masayoshi Kamata, Tomohiro Suzuki, Michiko Suzuki, Manabu Nakayama, Makiko Tomabechi, Tatsuhiko Nakasato, Shigeru Ehara


  • Changing roles of academic societies due to globalization

    by Shigeru Ehara, Shigeki Aoki, Hiroshi Honda

    Because of the globalization of environment around the academic society, the expected roles have changed significantly. In this short communication, we present the current situation in our international activities of the Japan Radiological Society, particularly in the academic activities and clinical practice. Establishing and reinforcing international network is one process of their promotion.

  • Open Access

    Clinical evaluation of18F-fludeoxyglucose positron emission tomography/CT using point spread function reconstruction for nodal staging of colorectal cancer

    by Kazuya Kawashima, Kenichi Kato, Makiko Tomabechi, Mikaru Matsuo, Koki Otsuka, Kazuyuki Ishida, Ryuji Nakamura, Shigeru Ehara

    Objectives:For patients with colorectal cancer, lymph node metastasis is a very important factor for prognostic and treatment determinations. 18F-fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) is among the useful tools for detecting lymph node metastasis. Recently, a new FDG-PET/CT reconstruction technique for improving spatial resolution and signal-to-noise ratios, point-spread function (PSF), has become available. We assessed the effect of PSF reconstruction on standardized uptake values (SUVs) and its diagnostic accuracy for lymph node staging in patients with colorectal cancer.Methods:We retrospectively analysed records from colorectal cancer patients who underwent FDG-PET/CT for preoperative staging. All PET/CT examinations were reconstructed using ordered subset expectation maximization (OSEM) and OSEM+PSF. We compared sensitivities, specificities, positive predictive values (PPVs), negative predictive values (NPVs), and accuracies of conventional-PET/CT (recons...


  • Subtraction CT angiography for the diagnosis of iliac arterial steno-occlusive disease

    by Michiko Suzuki, Ryoichi Tanaka, Kunihiro Yoshioka, Akihiko Abiko, Shigeru Ehara

    Purpose Accurate evaluation of stenosis in severely calcified arteries is a major challenge in conventional CT angiography (CTA) for peripheral arterial disease (PAD). The aim of this study was to evaluate the efficacy of subtraction CTA compared with conventional CTA and conventional angiography. Materials and methods 175 arterial segments of 31 consecutive patients with PAD who underwent CTA and subsequent digital subtraction angiography (DSA) were evaluated. The percentage stenosis of diseased arteries was measured in iliac arteries with caliper methods on conventional CTA and subtraction CTA, and the concordance of each CTA method with DSA in the identification of >50 % stenosis was evaluated. Interpretation of CTA was always based only on maximum intensity projection (MIP). Results 174 (99 %) segments were interpretable on subtraction CTA and showed a good correlation with DSA (R 2 = 0.844), although 55 (31 %) segments were not evaluable on conventional CTA due to severe calcification. On subtraction CTA, the segmental accuracy, sensitivity, and specificity were 90.5, 78.9, and 80.0 %, respectively. Conclusion Subtraction CTA is an accurate diagnostic tool for the evaluation of PAD. It may be easier to interpret stenosis in the presence of calcifications using subtraction CTA rather than with the conventional CTA approach. Also, subtraction CTA using only MIP presented a similar accuracy to DSA.


    • 1 September 2015
      • Vol. 42  (9) , 1127-30

    [Failure to Remove Long-Term Indwelling Central Venous Catheters in Two Patients].

    by Kazuya Kawashima, Kenichi Kato, Michiko Suzuki, Manabu Nakayama, Akio Tamura, Tomohiro Suzuki, Ryouichi Tanaka, Makiko Tomabechi, Mikaru Matsuo, Tatsuhiko Nakasato, et al.

    The use ofa central venous(CV)port system has become common for the treatment of patients with tumors. We report on the failure to remove CV catheters in 2 patients. The first patient was a 50 years woman with acute myeloid leukemia. She underwent CV port implantation via the left brachial approach 11 years previously. The second patient was an 80 years man with a lower gingival carcinoma. He underwent CV port implantation via the left brachial approach 6 years previously. CV catheter removal was attempted in both patients, but was unsuccessful because of strong adhesion to the vessel wall. Based on our experience, if catheter removal is impossible, its retention is more suitable.


  • CT-Guided Percutaneous Radiologic Gastrostomy for Patients with Head and Neck Cancer: A Retrospective Evaluation in 177 Patients

    by Akio Tamura, Kenichi Kato, Michiko Suzuki, Miyuki Sone, Ryoichi Tanaka, Tatsuhiko Nakasato, Shigeru Ehara

    The purpose of this study was to assess the technical success rate and adverse events (AEs) associated with computed tomography (CT)-guided percutaneous gastrostomy for patients with head and neck cancer (HNC). This retrospective study included patients with HNC who had undergone CT-guided percutaneous gastrostomy between February 2007 and December 2013. Information regarding the patients’ backgrounds, CT-guided percutaneous gastrostomy techniques, technical success rate, and AEs were obtained from the medical records. In all patients, the stomach was punctured under CT fluoroscopy with a Funada gastropexy device. During the study period, 177 patients underwent CT-guided percutaneous gastrostomy. The most common tumor location was the oral cavity, followed by the pharynx and maxilla. The indication for CT-guided percutaneous gastrostomy were tumor obstruction in 78 patients, postoperative dysphagia in 55 patients, radiation edema in 43 patients, and cerebral infarction in 1 patient. The technical success rate was 97.7 %. The overall mean procedure time was 25.3 min. Major AEs occurred in seven patients (4.0 %), including bleeding (n = 4), colonic injury (n = 1), gastric tear (n = 1), and aspiration pneumonia (n = 1). Minor AEs occurred in 15 patients (8.5 %), which included peristomal leakage (n = 6), irritation (n = 4), inadvertent removal (n = 2), peristomal hemorrhage (n = 1), peristomal infection (n = 1), and wound granulation (n = 1). The mean follow-up period was 111 days (range 1–1106 days). Our study suggests that CT-guided gastrostomy may be suitable in patients with HNC.


  • Open Access

    The “dot-in-circle” sign in musculoskeletal mycetoma on magnetic resonance imaging and ultrasonography

    by Teeranan Laohawiriyakamol, Pramot Tanutit, Kanet Kanjanapradit, Keerati Hongsakul, Shigeru Ehara

    This study aimed to present the ‘dot-in-circle’ sign, which indicates the typical magnetic resonance imaging (MRI) and ultrasonographic (USG) findings for mycetoma involving soft tissue and bone. A total of 8 cases with histopathological proof of mycetoma affecting the musculoskeletal system, and that were examined via MRI and/or coexistent diagnostic ultrasonography between 2004 and 2013 in Songklanagarind Hospital were included in this study. The ‘dot-in-circle’ sign on the MRI and USG images of all the patients was reviewed by two radiologists. The analytic method was descriptive. All cases of musculoskeletal mycetoma revealed the ‘dot-in-circle’ sign on MRI, which was seen as multiple, small, round- to oval-shaped hyperintense lesions separated and surrounded by a low-signal intensity rim (circle), and a tiny, central, low-signal focus (dot). An USG study was available in four patients, and all USG findings demonstrated the ‘dot-in-circle’ sign as a central hyperechoic area (dot) surrounded by hypoechoic tissue (circle). In conclusion, the ‘dot-in-circle’ sign is a typical feature on MRI and USG findings for the diagnosis of musculoskeletal mycetoma.


  • Low-dark-counting high-speed x-ray photon detection using an LSO Crystal and a small photomultiplier tube

    by Satoshi Yamaguchi, Eiichi Sato, Yasuyuki Oda, Ryuji Nakamura, Hirobumi Oikawa, Tomonori Yabuushi, Hisanori Ariga, Shigeru Ehara

    To develop a dual-energy X-ray CT (DE-CT) system, we have performed investigation of high-speed dual-energy photon counting using two comparators and a low-dark-counting LSO-MPPC (multipixel photon counter) detector. To measure X-ray spectra, electric charges produced in the MPPC are converted into voltages and amplified by a highspeed current-voltage amplifier, and the event pulses are sent to a multichannel analyzer. The MPPC was driven under pre-Geiger mode at an MPPC bias voltage of 70.7 V. The event pulses are sent to two high-speed comparators for selecting two threshold energies to perform DE-CT. The ED-CT is accomplished by repeated linear scans and rotations of the object, and two sets of projection curves of the object are obtained simultaneously by the linear scan. In the DECT, two different-energy tomograms are obtained simultaneously, and photon-count energy subtraction imaging was carried out.

  • Potentially symptomatic fabella: MR imaging review

    by Shigeru Ehara

    Fabella, a small ossicle at the posterolateral aspect of the knee, is potentially a source of knee pain. Although fabella syndrome is a rare cause of knee symptoms in young adults, osteocartilaginous degeneration prominent in the fabellofemoral joint on magnetic resonance imaging may be commonly seen in elderly patients.