Jorn A. van Dalen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jorn A. van Dalen has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Wim J. G. Oyen
Department of Radiology and Nuclear Medicine, Rijnstate Hospital, Arnhem, the Netherlands
3 shared publications Aswin L. Hoffmann
1 shared publicationBastiaan Wiering
1 shared publication- Eric P. Visser
Department of Nuclear Medicine, Radboud University Nijmegen Medical Centre, Nijmegen, the Netherlands
1 shared publication Frans H. M. Corstens
1 shared publicationG J Jager
1 shared publication
Latest Publications
- 1 June 2007
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 28 (6) , 485-493
A novel iterative method for lesion delineation and volumetric quantification with FDG PET
The determination of lesion boundaries on FDG PET is difficult due to the point-spread blurring and unknown uptake of activity within a lesion. Standard threshold-based methods for volumetric quantification on PET usually neglect any size dependence and are biased by dependence on the signal-to-background ratio (SBR). A novel, model-based method is hypothesized to provide threshold levels independent f the SBR and to allow accurate measurement of volumes down to the resolution of the PET scanner. A background-subtracted relative-threshold level (RTL) method was derived, based on a convolution of the point-spread function and a sphere with diameter D. Validation of the RTL method was performed using PET imaging of a Jaszczak phantom with seven hollow spheres (D=10-60 mm). Activity concentrations for the background and spheres (signal) were varied to obtain SBRs of 1.5-10. An iterative procedure was introduced for volumetric quantification, as the optimal RTL depends on a priori knowledge of the volume. The feasibility of the RTL method was tested in two patients with liver metastases and compared to a standard method using a fixed percentage of the signal. Phantom data validated that the theoretically optimal RTL depends on the sphere size, but not on the SBR. Typically, RTL=40% (D=15-60 mm), and RTL>50% for small spheres (D<12 mm). The RTL method is better applicable to patient data than the standard method. Based on an iterative procedure, the RTL method has been shown to provide optimal threshold levels independent of the SBR and to be applicable in phantom and in patient studies. It is a promising tool for lesion delineation and volumetric quantification of PET lesions.
- 1 June 2007
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 28 (6) , 485-493
A novel iterative method for lesion delineation and volumetric quantification with FDG PET
The determination of lesion boundaries on FDG PET is difficult due to the point-spread blurring and unknown uptake of activity within a lesion. Standard threshold-based methods for volumetric quantification on PET usually neglect any size dependence and are biased by dependence on the signal-to-background ratio (SBR). A novel, model-based method is hypothesized to provide threshold levels independent f the SBR and to allow accurate measurement of volumes down to the resolution of the PET scanner. A background-subtracted relative-threshold level (RTL) method was derived, based on a convolution of the point-spread function and a sphere with diameter D. Validation of the RTL method was performed using PET imaging of a Jaszczak phantom with seven hollow spheres (D=10-60 mm). Activity concentrations for the background and spheres (signal) were varied to obtain SBRs of 1.5-10. An iterative procedure was introduced for volumetric quantification, as the optimal RTL depends on a priori knowledge of the volume. The feasibility of the RTL method was tested in two patients with liver metastases and compared to a standard method using a fixed percentage of the signal. Phantom data validated that the theoretically optimal RTL depends on the sphere size, but not on the SBR. Typically, RTL=40% (D=15-60 mm), and RTL>50% for small spheres (D<12 mm). The RTL method is better applicable to patient data than the standard method. Based on an iterative procedure, the RTL method has been shown to provide optimal threshold levels independent of the SBR and to be applicable in phantom and in patient studies. It is a promising tool for lesion delineation and volumetric quantification of PET lesions.
- 9 February 2007
- Published by Wiley in Medical Physics
- Vol. 34 (3) , 889-897
Impact of ‐based versus CT‐based attenuation correction on PET
Transmission (Tx) scans are used in PET for attenuation correction (AC). For standalone PET this is typically done using Ge-68/Ga-68 sources, for PET-CT using CT. Therefore, standalone PET suffers from emission contamination during Tx scans, PET-CT does not. Here, we studied the effects of AC across the two systems. With a cylindrical phantom (Jaszczak Phantom, Data Spectrum Corp.) with hollow spheres (diameter 10-60 mm) two studies were performed. In the first study the hollow spheres were filled with 150 kBq/ml FDG and the background with 15 kBq/ml. In the second study we used 120 kBq/ml in the spheres and 50 kBq/ml in the background. Both a low and a high object-to-background ratio are studied this way. Multiple scans were acquired on a standalone PET and a PET-CT until 1% of the initial concentration remained. Activity concentration in the spheres and background was measured from the reconstructed images and compared to the actual concentration. For standalone PET, emission scans were reconstructed using hot Tx (emission contaminated) and cold Tx (not contaminated). Uniformity within the spheres was investigated by profile analysis. For PET-CT, the concentration in the big spheres (> 16 mm) was recovered. For the smaller spheres, recovery was insufficient due to partial volume effects. For standalone PET the recoveries of the spheres (> 16 mm) were 20% (first study) and 13% (second study) lower than the actual concentration. Using hot Tx, underestimation of activity concentration was up to > 50%. Nonuniformities within the biggest spheres were up to 35%, 12%, and 5% (first study), using standalone PET with hot Tx, cold Tx, and using PET-CT, respectively. Due to contamination of AC by emission photons, standalone PET results in a bias in the activity concentration and uniformity. Especially when patients get follow-up PET scans on both standalone PET and PET-CT, this may lead to misinterpretation.
- 9 February 2007
- Published by Wiley in Medical Physics
- Vol. 34 (3) , 889-897
Impact of ‐based versus CT‐based attenuation correction on PET
Transmission (Tx) scans are used in PET for attenuation correction (AC). For standalone PET this is typically done using Ge-68/Ga-68 sources, for PET-CT using CT. Therefore, standalone PET suffers from emission contamination during Tx scans, PET-CT does not. Here, we studied the effects of AC across the two systems. With a cylindrical phantom (Jaszczak Phantom, Data Spectrum Corp.) with hollow spheres (diameter 10-60 mm) two studies were performed. In the first study the hollow spheres were filled with 150 kBq/ml FDG and the background with 15 kBq/ml. In the second study we used 120 kBq/ml in the spheres and 50 kBq/ml in the background. Both a low and a high object-to-background ratio are studied this way. Multiple scans were acquired on a standalone PET and a PET-CT until 1% of the initial concentration remained. Activity concentration in the spheres and background was measured from the reconstructed images and compared to the actual concentration. For standalone PET, emission scans were reconstructed using hot Tx (emission contaminated) and cold Tx (not contaminated). Uniformity within the spheres was investigated by profile analysis. For PET-CT, the concentration in the big spheres (> 16 mm) was recovered. For the smaller spheres, recovery was insufficient due to partial volume effects. For standalone PET the recoveries of the spheres (> 16 mm) were 20% (first study) and 13% (second study) lower than the actual concentration. Using hot Tx, underestimation of activity concentration was up to > 50%. Nonuniformities within the biggest spheres were up to 35%, 12%, and 5% (first study), using standalone PET with hot Tx, cold Tx, and using PET-CT, respectively. Due to contamination of AC by emission photons, standalone PET results in a bias in the activity concentration and uniformity. Especially when patients get follow-up PET scans on both standalone PET and PET-CT, this may lead to misinterpretation.
- Open Access
- 1 January 2007
- Published by E-MED LTD in Cancer Imaging
- Vol. 7 (1) , 77-83
Multi-modality nuclear medicine imaging: artefacts, pitfalls and recommendations
Multi-modality nuclear medicine imaging: artefacts, pitfalls and recommendations - Cancer Imaging Multi-modality nuclear medicine imaging: artefacts, pitfalls and recommendations - Multi-modality imaging is rapidly becoming an essential tool in oncology. Clinically, the best example of multimodality imaging is seen in the rapid evolution of hybrid positron emission tomography (PET)/computed tomography (CT) and single positron emission computed tomography (SPECT)/CT scanners. However, use of multi-modality imaging is prone to artefacts and pitfalls. Important artefacts that may lead to clinical misinterpretation result from the use of CT data to correct for attenuation and the existence of mismatches between the fused images, for example due to respiratory movement.
- 1 January 2007
- Published by E-MED LTD in Cancer Imaging
- Vol. 7 (1) , 77-83
Open AccessMulti-modality nuclear medicine imaging: artefacts, pitfalls and recommendations
Multi-modality nuclear medicine imaging: artefacts, pitfalls and recommendations - Cancer Imaging Multi-modality nuclear medicine imaging: artefacts, pitfalls and recommendations - Multi-modality imaging is rapidly becoming an essential tool in oncology. Clinically, the best example of multimodality imaging is seen in the rapid evolution of hybrid positron emission tomography (PET)/computed tomography (CT) and single positron emission computed tomography (SPECT)/CT scanners. However, use of multi-modality imaging is prone to artefacts and pitfalls. Important artefacts that may lead to clinical misinterpretation result from the use of CT data to correct for attenuation and the existence of mismatches between the fused images, for example due to respiratory movement.
- 20 November 2004
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 49 (23) , 5393-5405
Accuracy of rigid CT–FDG-PET image registration of the liver
Diagnostic and surgical strategies could benefit from accurate localization of liver malignancies via CT-FDG-PET image registration. However, registration uncertainty occurs due to protocol differences in data-acquisition, the limited spatial resolution of positron emission tomography (PET) and the low uptake of 18F-fluorodeoxyglucose (FDG) in normal liver tissue. To assess this uncertainty, methods were presented to estimate registration precision and systematic bias. A semi-automatic, organ-focused method was investigated to minimize the uncertainty well beyond the typical uncertainty of 5-10 mm obtained by commonly available methods. By restricting registration to the liver region and by isolating the liver on computed tomography (CT) from surrounding structures using a thresholding technique, registration was achieved using the mutual information-based method as implemented in insight toolkit (ITK). CT and FDG-PET images of 10 patients with liver metastases were registered rigidly a number of times. Results of the organ-focused method were compared to results of three commonly available methods (a manual, a landmark-based and a 'standard' mutual information-based method) where no dedicated image processing was performed. The proposed method outperformed the other methods with a precision (mean+/-s.d.) of 2.5+/-1.3 mm and a bias of 1.9 mm with a 95% CI of [1.0, 2.8] mm. Unlike the commonly available methods, our approach allows for robust CT-FDG-PET registration of the liver, with an accuracy better than the spatial resolution of the PET scanner that was used.
- 20 November 2004
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 49 (23) , 5393-5405
Accuracy of rigid CT–FDG-PET image registration of the liver
Diagnostic and surgical strategies could benefit from accurate localization of liver malignancies via CT-FDG-PET image registration. However, registration uncertainty occurs due to protocol differences in data-acquisition, the limited spatial resolution of positron emission tomography (PET) and the low uptake of 18F-fluorodeoxyglucose (FDG) in normal liver tissue. To assess this uncertainty, methods were presented to estimate registration precision and systematic bias. A semi-automatic, organ-focused method was investigated to minimize the uncertainty well beyond the typical uncertainty of 5-10 mm obtained by commonly available methods. By restricting registration to the liver region and by isolating the liver on computed tomography (CT) from surrounding structures using a thresholding technique, registration was achieved using the mutual information-based method as implemented in insight toolkit (ITK). CT and FDG-PET images of 10 patients with liver metastases were registered rigidly a number of times. Results of the organ-focused method were compared to results of three commonly available methods (a manual, a landmark-based and a 'standard' mutual information-based method) where no dedicated image processing was performed. The proposed method outperformed the other methods with a precision (mean+/-s.d.) of 2.5+/-1.3 mm and a bias of 1.9 mm with a 95% CI of [1.0, 2.8] mm. Unlike the commonly available methods, our approach allows for robust CT-FDG-PET registration of the liver, with an accuracy better than the spatial resolution of the PET scanner that was used.