Wah-Keat Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wah-Keat Lee has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Patricia Fernandez
User Program Division, Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439, USA
3 shared publicationsDennis Mills
User Program Division, Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439, USA
2 shared publicationsGordon Tajiri
User Program Division, Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439, USA
2 shared publicationsKamel Fezzaa
Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439, USA
2 shared publications- Kamel Fezzaa
X-ray Science Division, Argonne National Laboratory 2 , Lemont, Illinois 60439
2 shared publications - David Christophe Dunand
Department of Materials Science and Engineering, Northwestern University, Evanston, USA
1 shared publication
Latest Publications
- Open Access
- 23 November 2010
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 18 (2) , 302-304
Three-dimensional X-ray micro-velocimetry
A direct measurement of three-dimensional X-ray velocimetry with micrometer spatial resolution is presented. The key to this development is the use of a Laue crystal as an X-ray beam splitter and mirror. Three-dimensional flow velocities in a 0.4 mm-diameter tubing were recorded, with <5 µm spatial resolution and speeds of 0.7 mm s(-1). This development paves the way for three-dimensional velocimetry in many cases where visible-light techniques are not effective, such as multiphase flow or flow of optically opaque liquids.
- 23 November 2010
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 18 (2) , 302-304
Open AccessThree-dimensional X-ray micro-velocimetry
A direct measurement of three-dimensional X-ray velocimetry with micrometer spatial resolution is presented. The key to this development is the use of a Laue crystal as an X-ray beam splitter and mirror. Three-dimensional flow velocities in a 0.4 mm-diameter tubing were recorded, with <5 µm spatial resolution and speeds of 0.7 mm s(-1). This development paves the way for three-dimensional velocimetry in many cases where visible-light techniques are not effective, such as multiphase flow or flow of optically opaque liquids.
- 23 March 2010
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 322 (17) , 2525-2528
X-ray microtomography of field-induced macro-structures in a ferrofluid
- 23 March 2010
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 322 (17) , 2525-2528
X-ray microtomography of field-induced macro-structures in a ferrofluid
- Open Access
- 1 January 2009
- Published by Springer Nature in BMC Physiology
- Vol. 9 (1) , 2
Direct visualization of hemolymph flow in the heart of a grasshopper (Schistocerca americana)
Hemolymph flow patterns in opaque insects have never been directly visualized due to the lack of an appropriate imaging technique. The required spatial and temporal resolutions, together with the lack of contrast between the hemolymph and the surrounding soft tissue, are major challenges. Previously, indirect techniques have been used to infer insect heart motion and hemolymph flow, but such methods fail to reveal fine-scale kinematics of heartbeat and details of intra-heart flow patterns.
- 1 January 2009
- Published by Springer Nature in BMC Physiology
- Vol. 9 (1) , 2
Open AccessDirect visualization of hemolymph flow in the heart of a grasshopper (Schistocerca americana)
Hemolymph flow patterns in opaque insects have never been directly visualized due to the lack of an appropriate imaging technique. The required spatial and temporal resolutions, together with the lack of contrast between the hemolymph and the surrounding soft tissue, are major challenges. Previously, indirect techniques have been used to infer insect heart motion and hemolymph flow, but such methods fail to reveal fine-scale kinematics of heartbeat and details of intra-heart flow patterns.
- Open Access
- 1 March 2007
- Published by Springer Nature in BMC Biology
- Vol. 5 (1) , 6
Real-time phase-contrast x-ray imaging: a new technique for the study of animal form and function
Despite advances in imaging techniques, real-time visualization of the structure and dynamics of tissues and organs inside small living animals has remained elusive. Recently, we have been using synchrotron x-rays to visualize the internal anatomy of millimeter-sized opaque, living animals. This technique takes advantage of partially-coherent x-rays and diffraction to enable clear visualization of internal soft tissue not viewable via conventional absorption radiography. However, because higher quality images require greater x-ray fluxes, there exists an inherent tradeoff between image quality and tissue damage.
- 1 March 2007
- Published by Springer Nature in BMC Biology
- Vol. 5 (1) , 6
Open AccessReal-time phase-contrast x-ray imaging: a new technique for the study of animal form and function
Despite advances in imaging techniques, real-time visualization of the structure and dynamics of tissues and organs inside small living animals has remained elusive. Recently, we have been using synchrotron x-rays to visualize the internal anatomy of millimeter-sized opaque, living animals. This technique takes advantage of partially-coherent x-rays and diffraction to enable clear visualization of internal soft tissue not viewable via conventional absorption radiography. However, because higher quality images require greater x-ray fluxes, there exists an inherent tradeoff between image quality and tissue damage.
- 26 January 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6279, 627910
High-speed hard x-ray phase-enhanced imaging
Conventional x-ray imaging relies on the differences in the absorption of the sample to provide image contrast. With the small source sizes and large source-sample distances at synchrotrons, an additional mechanism, phase contrast, can come into play. Phase effects, which include refraction and diffraction, can greatly enhance the image contrast. Phase contrast is particularly useful in cases where the absorption contrast is weak. Added to this, the high x-ray flux available at synchrotrons allows for unprecedented high-speed and high-resolution x-ray imaging. We demonstrate that high quality time resolved images with sub-microsecond temporal and micrometer spatial resolutions are feasible. The range of energy spectrum (5-150 keV) available at the Advanced Photon Source allows us to study a wide range of samples, from soft tissues to high-Z materials. We will present preliminary results from the steel automobile fuel injectors and liquidair sprays
- 26 January 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6279, 627910
High-speed hard x-ray phase-enhanced imaging
Conventional x-ray imaging relies on the differences in the absorption of the sample to provide image contrast. With the small source sizes and large source-sample distances at synchrotrons, an additional mechanism, phase contrast, can come into play. Phase effects, which include refraction and diffraction, can greatly enhance the image contrast. Phase contrast is particularly useful in cases where the absorption contrast is weak. Added to this, the high x-ray flux available at synchrotrons allows for unprecedented high-speed and high-resolution x-ray imaging. We demonstrate that high quality time resolved images with sub-microsecond temporal and micrometer spatial resolutions are feasible. The range of energy spectrum (5-150 keV) available at the Advanced Photon Source allows us to study a wide range of samples, from soft tissues to high-Z materials. We will present preliminary results from the steel automobile fuel injectors and liquidair sprays
- 1 January 2004
- Published by Springer Nature in MRS Proceedings
- Vol. 840
Internal Strain Measurements and X-ray Imaging in Interpenetrating-Phase Al2O3/Al Composites
- 1 January 2004
- Published by Springer Nature in MRS Proceedings
- Vol. 840
Internal Strain Measurements and X-ray Imaging in Interpenetrating-Phase Al2O3/Al Composites
- 23 December 2003
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations of Crystallography
- Vol. 60 (1) , 58-63
Dispersion corrections of the copperKedge measured by Fresnel diffraction
Dispersion corrections to the atomic scattering factors for the copper K edge have been measured by a new technique, Fresnel diffraction. Fresnel diffraction fringes were measured at several sample-detector distances as a function of energy across the copper K-absorption edge. The dispersion corrections were obtained from optimizing a least-squares fit of Fresnel fringe simulations to the measured data.
- 23 December 2003
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations of Crystallography
- Vol. 60 (1) , 58-63
Dispersion corrections of the copperKedge measured by Fresnel diffraction
Dispersion corrections to the atomic scattering factors for the copper K edge have been measured by a new technique, Fresnel diffraction. Fresnel diffraction fringes were measured at several sample-detector distances as a function of energy across the copper K-absorption edge. The dispersion corrections were obtained from optimizing a least-squares fit of Fresnel fringe simulations to the measured data.
- 28 August 2001
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 8 (5) , 1140-1148
Nonlinear thermal-distortion predictions of a silicon monochromator using the finite element method
- 28 August 2001
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 8 (5) , 1140-1148
Nonlinear thermal-distortion predictions of a silicon monochromator using the finite element method
- 1 January 2001
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 8 (1) , 22-25
Performance limits of indirectly cryogenically cooled silicon monochromators – experimental results at the APS
The results of high-heat-load tests of indirectly cryogenically cooled silicon monochromators are presented. The measurements show that, provided that the total power absorbed by the crystal is less than approximately 150 W, indirect cryogenically cooled silicon monochromators will perform well, with thermal-induced slope errors of less than 2 arcsec. At the Advanced Photon Source, this corresponds to the undulator closed-gap (11 mm) condition at 100 mA with white-beam slit sizes slightly larger than the full width at half-maximum of the radiation central cones. The dependence of the slope errors on the thermomechanical properties of silicon are discussed and clearly demonstrated.
- 1 January 2001
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 8 (1) , 22-25
Performance limits of indirectly cryogenically cooled silicon monochromators – experimental results at the APS
The results of high-heat-load tests of indirectly cryogenically cooled silicon monochromators are presented. The measurements show that, provided that the total power absorbed by the crystal is less than approximately 150 W, indirect cryogenically cooled silicon monochromators will perform well, with thermal-induced slope errors of less than 2 arcsec. At the Advanced Photon Source, this corresponds to the undulator closed-gap (11 mm) condition at 100 mA with white-beam slit sizes slightly larger than the full width at half-maximum of the radiation central cones. The dependence of the slope errors on the thermomechanical properties of silicon are discussed and clearly demonstrated.
- 1 January 2000
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 7 (1) , 12-17
Performance limits of direct cryogenically cooled silicon monochromators – experimental results at the APS
The successful use of cryogenically cooled silicon monochromators at third-generation synchrotron facilities is well documented. At the Advanced Photon Source (APS) it has been shown that, at 100 mA operation with the standard APS undulator A, the cryogenically cooled silicon monochromator performs very well with minimal (<2 arcsec) or no observable thermal distortions. However, to date there has not been any systematic experimental study on the performance limits of this approach. This paper presents experimental results on the performance limits of these directly cooled crystals. The results show that if the beam is limited to the size of the radiation central cone then, at the APS, the crystal will still perform well at twice the present 100 mA single 2.4 m-long 3.3 cm-period undulator heat load. However, the performance would degrade rapidly if a much larger incident white-beam size is utilized.
- 1 January 2000
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 7 (1) , 12-17
Performance limits of direct cryogenically cooled silicon monochromators – experimental results at the APS
The successful use of cryogenically cooled silicon monochromators at third-generation synchrotron facilities is well documented. At the Advanced Photon Source (APS) it has been shown that, at 100 mA operation with the standard APS undulator A, the cryogenically cooled silicon monochromator performs very well with minimal (<2 arcsec) or no observable thermal distortions. However, to date there has not been any systematic experimental study on the performance limits of this approach. This paper presents experimental results on the performance limits of these directly cooled crystals. The results show that if the beam is limited to the size of the radiation central cone then, at the APS, the crystal will still perform well at twice the present 100 mA single 2.4 m-long 3.3 cm-period undulator heat load. However, the performance would degrade rapidly if a much larger incident white-beam size is utilized.