MHMark Hilgart

Mark Hilgart

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mark Hilgart has a total of 98 co-authors. Here are the top co-authors by number of shared publications:

  • Ruslan Sanishvili

    GM/CA@APS, Argonne National Laboratory, 9700 South Cass Avenue, Lemont, IL 60439, USA

    7 shared publications
  • Janet L. Smith

    Life Sciences Institute and Department of Biological Chemistry, University of Michigan, Ann Arbor, MI 48109, USA

    6 shared publications
  • Michael Becker

    GM/CA@APS, Argonne National Laboratory, 9700 South Cass Avenue, Lemont, IL 60439, USA

    6 shared publications
  • Robert F. Fischetti

    GM/CA@APS, Argonne National Laboratory, 9700 South Cass Avenue, Lemont, IL 60439, USA

    6 shared publications
  • Oleg Makarov

    Biosciences Division, Argonne National Laboratory, 9700 South Cass Avenue, Bldg 436D, Argonne, IL 60439, USA

    5 shared publications
  • Sergey Stepanov

    GM/CA@APS, Argonne National Laboratory, 9700 South Cass Avenue, Lemont, IL 60439, USA

    5 shared publications

Latest Publications

  • Open Access

    Fast automated energy changes at synchrotron radiation beamlines equipped with transfocator or focusing mirrors

    by Sergey Stepanov, David Kissick, Oleg Makarov, Mark Hilgart, Michael Becker, Nagarajan Venugopalan, Shenglan Xu, Janet L. Smith, Robert F. Fischetti

    Algorithms and procedures to fully automate retuning of synchrotron radiation beamlines over wide energy ranges are discussed. The discussion is based on the implementation at the National Institute of General Medical Sciences and the National Cancer Institute Structural Biology Facility at the Advanced Photon Source. When a user selects a new beamline energy, software synchronously controls the beamline monochromator and undulator to maintain the X-ray beam flux after the monochromator, preserves beam attenuation by determining a new set of attenuator foils, changes, as needed, mirror reflecting stripes and the undulator harmonic, preserves beam focal distance of compound refractive lens focusing by changing the In/Out combination of lenses in the transfocator, and, finally, restores beam position at the sample by on-the-fly scanning of either the Kirkpatrick–Baez mirror angles or the transfocator up/down and inboard/outboard positions. The sample is protected from radiation damage by automatically moving it out of the beam during the energy change and optimization.


  • Open Access

    Improvements in serial crystallography capabilities at GM/CA

    by D. J. Kissick, J. M. Martin-Garcia, H. Hu, N. Venugopalan, S. Xu, S. Corcoran, D. Ferguson, M. C. Hilgart, O. Makarov, Q. Xu, et al.

  • Open Access

    Serial millisecond crystallography of membrane and soluble protein microcrystals using synchrotron radiation

    by Jose M. Martin-Garcia, Chelsie E. Conrad, Garrett Nelson, Natasha Stander, Nadia A. Zatsepin, James Zook, Lan Zhu, James Geiger, Eugene Chun, David Kissick, et al.

    Crystal structure determination of biological macromolecules using the novel technique of serial femtosecond crystallography (SFX) is severely limited by the scarcity of X-ray free-electron laser (XFEL) sources. However, recent and future upgrades render microfocus beamlines at synchrotron-radiation sources suitable for room-temperature serial crystallography data collection also. Owing to the longer exposure times that are needed at synchrotrons, serial data collection is termed serial millisecond crystallography (SMX). As a result, the number of SMX experiments is growing rapidly, with a dozen experiments reported so far. Here, the first high-viscosity injector-based SMX experiments carried out at a US synchrotron source, the Advanced Photon Source (APS), are reported. Microcrystals (5–20 µm) of a wide variety of proteins, including lysozyme, thaumatin, phycocyanin, the human A2Aadenosine receptor (A2AAR), the soluble fragment of the membrane lipoprotein Flpp3 and proteinase K, were screened. Crystals suspended in lipidic cubic phase (LCP) or a high-molecular-weight poly(ethylene oxide) (PEO; molecular weight 8 000 000) were delivered to the beam using a high-viscosity injector. In-house data-reduction (hit-finding) software developed at APS as well as the SFX data-reduction and analysis software suitesCheetahandCrystFELenabled efficient on-site SMX data monitoring, reduction and processing. Complete data sets were collected for A2AAR, phycocyanin, Flpp3, proteinase K and lysozyme, and the structures of A2AAR, phycocyanin, proteinase K and lysozyme were determined at 3.2, 3.1, 2.65 and 2.05 Å resolution, respectively. The data demonstrate the feasibility of serial millisecond crystallography from 5–20 µm crystals using a high-viscosity injector at APS. The resolution of the crystal structures obtained in this study was dictated by the current flux density and crystal size, but upcoming developments in beamline optics and the planned APS-U upgrade will increase the intensity by two orders of magnitude. These developments will enable structure determination from smaller and/or weakly diffracting microcrystals.


  • Open Access

    Tightly integrated single- and multi-crystal data collection strategy calculation and parallelized data processing inJBluIcebeamline control system

    by Sudhir Babu Pothineni, Nagarajan Venugopalan, Craig M. Ogata, Mark C. Hilgart, Sergey Stepanov, Ruslan Sanishvili, Michael Becker, Graeme Winter, Nicholas K. Sauter, Janet L. Smith, et al.

    The calculation of single- and multi-crystal data collection strategies and a data processing pipeline have been tightly integrated into the macromolecular crystallographic data acquisition and beamline control softwareJBluIce. Both tasks employ wrapper scripts around existing crystallographic software.JBluIceexecutes scripts through a distributed resource management system to make efficient use of all available computing resources through parallel processing. TheJBluIcesingle-crystal data collection strategy feature uses a choice of strategy programs to help users rank sample crystals and collect data. The strategy results can be conveniently exported to a data collection run. TheJBluIcemulti-crystal strategy feature calculates a collection strategy to optimize coverage of reciprocal space in cases where incomplete data are available from previous samples. TheJBluIcedata processing runs simultaneously with data collection using a choice of data reduction wrappers for integration and scaling of newly collected data, with an option for merging with pre-existing data. Data are processed separately if collected from multiple sites on a crystal or from multiple crystals, then scaled and merged. Results from all strategy and processing calculations are displayed in relevant tabs ofJBluIce.


  • JBluIce-EPICS: a fast and flexible open-source beamline control system for macromolecular crystallography

    by S Stepanov, M Hilgart, O Makarov, S B Pothineni, D Yoder, C Ogata, R Sanishvili, N Venugopalan, M Becker, M Clift, et al.

    This paper overviews recent advances in the JBluIce-EPICS open-source control system designed at the macromolecular crystallography beamlines of the National Institute of General Medical Sciences and National Cancer Institute at the Advanced Photon Source (GM/CA@APS). We discuss some technical highlights of this system distinguishing it from the competition, such as reduction of software layers to only two, possibility to operate JBluIce in parallel with other beamline controls, plugin-enabled architecture where the plugins can be written in any programming language, and utilization of the whole power of the Java integrated development environment in the Graphical User Interface. Then, we demonstrate how these highlights help to make JBluIce fast, easily adaptable to new beamline developments, and intuitive for users. In particular, we discuss several recent additions to the system including a bridge between crystal rastering and data collection, automatic detection of raster polygons from optical crystal centering, background data processing, and a pathway to a fully automated pipeline from crystal screening to solving crystal structure.


  • Automated sample-scanning methods for radiation damage mitigation and diffraction-based centering of macromolecular crystals

    by Mark C. Hilgart, Ruslan Sanishvili, Craig M. Ogata, Michael Becker, Nagarajan Venugopalan, Sergey Stepanov, Oleg Makarov, Janet L. Smith, Robert F. Fischetti

    Automated scanning capabilities have been added to the data acquisition software, JBluIce-EPICS, at the National Institute of General Medical Sciences and the National Cancer Institute Collaborative Access Team (GM/CA CAT) at the Advanced Photon Source. A `raster' feature enables sample centering via diffraction scanning over two-dimensional grids of simple rectangular or complex polygonal shape. The feature is used to locate crystals that are optically invisible owing to their small size or are visually obfuscated owing to properties of the sample mount. The raster feature is also used to identify the best-diffracting regions of large inhomogeneous crystals. Low-dose diffraction images taken at grid positions are automatically processed in real time to provide a quick quality ranking of potential data-collection sites. A `vector collect' feature mitigates the effects of radiation damage by scanning the sample along a user-defined three-dimensional vector during data collection to maximize the use of the crystal volume and the quality of the collected data. These features are integrated into the JBluIce-EPICS data acquisition software developed at GM/CA CAT where they are used in combination with a robust mini-beam of rapidly changeable diameter from 5 µm to 20 µm. The powerful software-hardware combination is being applied to challenging problems in structural biology.


  • Fast fluorescence techniques for crystallography beamlines

    by Sergey Stepanov, Mark Hilgart, Derek W. Yoder, Oleg Makarov, Michael Becker, Ruslan Sanishvili, Craig M. Ogata, Nagarajan Venugopalan, David Aragão, Martin Caffrey, et al.

    This paper reports on several developments of X-ray fluorescence techniques for macromolecular crystallography recently implemented at the National Institute of General Medical Sciences and National Cancer Institute beamlines at the Advanced Photon Source. These include (i) three-band on-the-fly energy scanning around absorption edges with adaptive positioning of the fine-step band calculated from a coarse pass; (ii) on-the-fly X-ray fluorescence rastering over rectangular domains for locating small and invisible crystals with a shuttle-scanning option for increased speed; (iii) fluorescence rastering over user-specified multi-segmented polygons; and (iv) automatic signal optimization for reduced radiation damage of samples.


  • JBluIce–EPICScontrol system for macromolecular crystallography

    by Sergey Stepanov, Oleg Makarov, Mark Hilgart, Sudhir Babu Pothineni, Alex Urakhchin, Satish Devarapalli, Derek Yoder, Michael Becker, Craig Ogata, Ruslan Sanishvili, et al.

    The trio of macromolecular crystallography beamlines constructed by the General Medicine and Cancer Institutes Collaborative Access Team (GM/CA-CAT) in Sector 23 of the Advanced Photon Source (APS) have been in growing demand owing to their outstanding beam quality and capacity to measure data from crystals of only a few micrometres in size. To take full advantage of the state-of-the-art mechanical and optical design of these beamlines, a significant effort has been devoted to designing fast, convenient, intuitive and robust beamline controls that could easily accommodate new beamline developments. The GM/CA-CAT beamline controls are based on the power of EPICS for distributed hardware control, the rich Java graphical user interface of Eclipse RCP and the task-oriented philosophy as well as the look and feel of the successful SSRL BluIce graphical user interface for crystallography. These beamline controls feature a minimum number of software layers, the wide use of plug-ins that can be written in any language and unified motion controls that allow on-the-fly scanning and optimization of any beamline component. This paper describes the ways in which BluIce was combined with EPICS and converted into the Java-based JBluIce, discusses the solutions aimed at streamlining and speeding up operations and gives an overview of the tools that are provided by this new open-source control system for facilitating crystallographic experiments, especially in the field of microcrystallography.


  • Micro-Crystallography Developments at GM∕CA-CAT at the APS

    by Shenglan Xu, Oleg Makarov, Rich Benn, Derek W. Yoder, Sergey Stepanov, Michael Becker, Stephen Corcoran, Mark Hilgart, Venugopalan Nagarajan, Craig M. Ogata, et al.

    Recently, several important structures have been solved using micro‐crystallographic techniques that previously could not have been solved with conventional crystallography. At GM/CA‐CAT we continue to develop micro‐crystallographic capabilities for difficult problems such as small crystals of large macromolecular complexes or membrane proteins grown in the lipidic cubic phase. This paper will describe three major upgrades to our arsenal of tools, “mini‐beam” collimators, active beamstop, and an improved goniostat. Our “mini‐beam” collimators have evolved to a new triple‐collimator fabricated from molybdenum as a uni‐body. This has significantly improved the robustness, ease of initial alignment, and reduction of background. More recently, two prototypes of a quad‐collimator have been developed and fabricated to provide a selection of mini‐beams of 5, 10, 20 μm and a 300 μm scatter‐guard on a single body. The smaller beams and samples have increased the demand on the tolerances of our goniostat. To meet these challenges we have designed and implemented a goniostat with a 1‐micron peak‐to‐peak sphere of confusion. This is a significant improvement over the previous 6 micron sphere of confusion of the commercially available air‐bearing and XY stages. Finally, an “active beamstop” has been constructed. This will provide non‐invasive, real time feedback at the sample during data collection.