Richard M. Cooper
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Richard M. Cooper has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
John A. Pacey
University of British Columbia
1 shared publicationLouise Ellard
Toronto General Hospital
1 shared publication- Matteo Parotto
Department of Anesthesiology and Pain Medicine, Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, Ontario, Canada
1 shared publication Michael J. Bishop
University of Washington and Veterans Affairs Puget Sound Health Care System
1 shared publicationSofia M. Khan
University of Toronto
1 shared publicationStuart A. McCluskey
Toronto General Hospital
1 shared publication
Latest Publications
- Open Access
- 1 December 2015
- Published by Springer Nature in Critical Care
- Vol. 19 (1) , 151
Tracheal extubation and reintubation of the critically ill - challenges coming and going
Tracheal reintubation is a common event in critical care. Elmer and colleagues provide the first comparison of complication rates of initial and subsequent reintubation(s) during the same hospitalization. Their work shows an increased risk of complications associated with reintubation, in particular hypoxemia and hypotension, reminding us to be cautious with patients having minimal reserve and potentially altered airway anatomy. See related research by Elmer et al., http://ccforum.com/content/19/1/12
- 1 December 2015
- Published by Springer Nature in Critical Care
- Vol. 19 (1) , 151
Open AccessTracheal extubation and reintubation of the critically ill - challenges coming and going
Tracheal reintubation is a common event in critical care. Elmer and colleagues provide the first comparison of complication rates of initial and subsequent reintubation(s) during the same hospitalization. Their work shows an increased risk of complications associated with reintubation, in particular hypoxemia and hypotension, reminding us to be cautious with patients having minimal reserve and potentially altered airway anatomy. See related research by Elmer et al., http://ccforum.com/content/19/1/12
- 28 March 2014
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 61 (6) , 587-90
From the Journal archives: A streamlined anesthetic system: the Bain (and Spoerel) circuit 40 years later.
- 28 March 2014
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 61 (6) , 587-90
From the Journal archives: A streamlined anesthetic system: the Bain (and Spoerel) circuit 40 years later.
- 5 November 2012
- Published by Springer Nature
- p. 271-287
Extubation of the Difficult Airway
- 13 November 2010
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 58 (2) , 224-225
Superior glottic views with the GlideScope® and Airtraq® laryngoscopes compared with an anterior commissure laryngoscope
- 13 November 2010
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 58 (2) , 224-225
Superior glottic views with the GlideScope® and Airtraq® laryngoscopes compared with an anterior commissure laryngoscope
- 1 July 2010
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 111 (1) , 244
Reducing the Risks Associated with Videolaryngoscopy
- 1 July 2010
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 111 (1) , 244
Reducing the Risks Associated with Videolaryngoscopy
- 1 June 2008
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 108 (6) , 1150
Concerns about the Purported Safety of Elective Flexible Bronchoscopic-assisted Intubation
Heidegger et al. 1 are to be congratulated for a well-performed study that validates the relative safety of their practice. The conclusions from their study, however, can be applied only narrowly. First, as they admit, it was conducted by individuals with extensive previous experience with the technique. Indeed, each had performed more than 200 previous bronchoscopic intubations. Therefore, the study addresses the safety of bronchoscopic-assisted intubation for those needing to maintain, rather than acquire, this skill. It does not serve to document the equivalent safety of this technique with direct laryngoscopy for those with limited previous experience. Second, the study was performed on the very population not requiring flexible bronchoscopic intubation—namely, those with normal airways. The study falls short of documenting the absence of vocal cord sequelae when performed in patients who may require this approach. Third, the authors have compared the vocal cord sequelae resulting from a nasally inserted 6-mm tube with an orally inserted 7- or 8-mm tube. Nasal tubes assume a more vertical passage through the larynx and exert less force on the posteromedial glottis.2 Likewise, smaller tubes probably exert less force on the vocal folds and arytenoid cartilages.3 Finally, their technique involved the induction of anesthesia absent neuromuscular blockers. The national guidelines referred to,4,5 insofar as they address the anticipated difficult airway, recommend the preservation of spontaneous ventilation. This demands much less medication than Heidegger et al. administered and results in a higher probability of coughing and difficulty in advancing the tube. These may increase the probability of vocal cord sequelae.
- 1 June 2008
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 108 (6) , 1150
Concerns about the Purported Safety of Elective Flexible Bronchoscopic-assisted Intubation
Heidegger et al. 1 are to be congratulated for a well-performed study that validates the relative safety of their practice. The conclusions from their study, however, can be applied only narrowly. First, as they admit, it was conducted by individuals with extensive previous experience with the technique. Indeed, each had performed more than 200 previous bronchoscopic intubations. Therefore, the study addresses the safety of bronchoscopic-assisted intubation for those needing to maintain, rather than acquire, this skill. It does not serve to document the equivalent safety of this technique with direct laryngoscopy for those with limited previous experience. Second, the study was performed on the very population not requiring flexible bronchoscopic intubation—namely, those with normal airways. The study falls short of documenting the absence of vocal cord sequelae when performed in patients who may require this approach. Third, the authors have compared the vocal cord sequelae resulting from a nasally inserted 6-mm tube with an orally inserted 7- or 8-mm tube. Nasal tubes assume a more vertical passage through the larynx and exert less force on the posteromedial glottis.2 Likewise, smaller tubes probably exert less force on the vocal folds and arytenoid cartilages.3 Finally, their technique involved the induction of anesthesia absent neuromuscular blockers. The national guidelines referred to,4,5 insofar as they address the anticipated difficult airway, recommend the preservation of spontaneous ventilation. This demands much less medication than Heidegger et al. administered and results in a higher probability of coughing and difficulty in advancing the tube. These may increase the probability of vocal cord sequelae.
- 1 October 2007
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 54 (10) , 786-789
ProSeal LMA — how long is too long?
- 1 October 2007
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 54 (10) , 786-789
ProSeal LMA — how long is too long?
- Open Access
- 1 July 2007
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 107 (1) , 170
More Trouble with Airway Definitions
- 1 July 2007
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 107 (1) , 170
Open AccessMore Trouble with Airway Definitions
- Top Cited Papers
- 1 January 2007
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 54 (1) , 54-57
Complications associated with the use of the GlideScope® videolaryngoscope
Tw o cases are presented wherein the GlideScope® videolaryngoscope (GVL) facilitated laryngeal exposure and successful endotracheal intubation, but resulted in pharyngeal injury.
- 1 January 2007
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 54 (1) , 54-57
Top Cited PapersComplications associated with the use of the GlideScope® videolaryngoscope
Tw o cases are presented wherein the GlideScope® videolaryngoscope (GVL) facilitated laryngeal exposure and successful endotracheal intubation, but resulted in pharyngeal injury.
- 15 December 2005
- Published by Wiley in Anaesthesia
- Vol. 61 (1) , 77-78
A response to ‘Airway management before, during and after extubation: a survey of practice in the United Kingdom and Ireland’
- 15 December 2005
- Published by Wiley in Anaesthesia
- Vol. 61 (1) , 77-78
A response to ‘Airway management before, during and after extubation: a survey of practice in the United Kingdom and Ireland’