CKCornelis Kluft

Cornelis Kluft

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Cornelis Kluft has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Introduction to haemostasis from a pharmacodynamic perspective

    by Cornelis Kluft, Jacobus Burggraaf

    Biochemical characterization of the haemostatic system has advanced significantly in the past decades. Sub‐systems, such as coagulation, fibrinolysis, blood cells and platelets and the vessel wall have been studied by specialists, mostly separately and independently. The time has come to integrate the approaches, and, in particular, to develop tests to document the state of the whole system and to have available adequate pharmacodynamic tests to evaluate treatments. Many examples are available to show that traditional general methods of clotting and lysis do not provide the information that is desired. The present tendency is to use specific methods for specific factors or effects which are very limited in pharmacological information. There is also increasing awareness of the occurrence of rather broad interindividual variability in the haemostatic system. This suggests that individually tailored treatments are required. This is the more relevant since haemostasis is a balance and treatment should be positioned between efficacy and safety. The conclusion is reached that there is a need for integrated or global methods or sets of methods that reflect the complexity and individual status appropriately and allow the practitioner to judge the effects of interventions and their individual aspects.


  • External Quality Assessment for Thrombin Generation Tests: An Exploration

    by Cornelis Kluft, Piet Meijer

    External Quality Control of Diagnostic Assays and Tests (ECAT) surveys on thrombin generation rests (TGTs) have identified that various tests show a more than 30-fold difference in time to peak (TTP). The survey included pooled normal plasmas, microparticle (MP)-depleted plasmas, and factor (F)XII-deficient patient plasma. Between 4 and 11 laboratories participated per test; analyzed were a time (TTP) and quantity variable (AUC). MP depletion of plasma showed a progressive increase in TTP up to 29% with a decreasing tissue factor. The same was found for the AUC with the largest decrease of 38%. It was observed that MP depletion showed large individual differences. The FXII-deficient plasma showed no effect on TTP for rapid tests, but for slow tests it increased from 248 to 331%. The AUC declined gradually the slower the test, reaching a decline of 85%. The effects of FXII deficiency were not mimicked by the addition of corn trypsin inhibitor but were confirmed by inhibiting activated FXI. Interlaboratory variability was between 11% and 57% for all methods, showing differences mainly related to the used normal pooled plasma. The different sensitivities of TGTs to MPs and contact activation predict that they will associate differently with clinical situations, according to which of these aspects are important. Future ECAT surveys should include samples with variation in MPs and contact activation to match with features of the TGT variants.


    • 1 November 2006
      • Vol. 96  (5) , 584-9

    Performance goals for the laboratory testing of antithrombin, protein C and protein S.

    by Piet Meijer, Frits Haverkate, Cornelis Kluft

    To achieve a reliable analytical quality for both monitoring and diagnostic testing, laboratories need to fulfil the widely accepted analytical performance goals based on the biological variation of the analytes of testing. Not only is the short-term analytical performance, which regularly is assessed by internal quality control procedures, of importance, but also the long-term analytical performance. To assess the long-term analytical performance, data obtained from an external quality assessment programme can be used. In this study we have used the evaluation model designed by the ECAT Foundation for the assessment of the longterm analytical performance, including imprecision, bias and total analytical error. The model was applied to the data from 136 different laboratories for the assay of antithrombin (activity), protein C (activity and antigen) and protein S (activity, total and free antigen). The imprecision (median; range), reflected by the long-term analytical coefficient of variation (LCV (A) ), was the lowest for antithrombin (7.6%; 2.6 - 43.8%) and the highest for protein S activity (17.2%; 4.3 - 88.6%). For bias and total error the same pattern was observed (antithrombin: 3.8%; 0.3 - 17.1% and 9.1%; 3.4 - 34.3%, respectively; protein S activity: 12.8%; 3.1 - 34.8% and 24.5%; 9.9 - 87.0%, respectively). For the majority of the laboratories (70 - 85%) the imprecision contributes considerably more to the total error than the bias. However the effect of the bias on the analytical quality is not negligible. Assays for antithrombin, protein C and protein S are mainly used for diagnostic testing. About 70 - 100% of the laboratories can fulfil the desirable performance goal for imprecision. The desirable performance goal for bias was reached by 50 - 95% of the laboratories. In all cases the highest numbers of laboratories fulfilling performance goals was obtained for the protein C variables. To improve the analytical quality in assays of antithrombin, protein C and protein S it is highly recommended that primarily imprecision (non-systematic failures) be suppressed. However the effect of the bias (systematic failures) on the analytical quality should not be neglected. A useful tool for determining the imprecision (LCV (A) ) and bias is the long-term analytical performance evaluation model as used by the ECAT Foundation.


  • Open Access

    Quality Assessment of CoaguChek Point-of-Care Prothrombin Time Monitors: Comparison of the European Community-Approved Procedure and Conventional External Quality Assessment

    by Leon Poller, Michelle Keown, Saied A. Ibrahim, Felix J.M. van der Meer, Anton M.H.P. van Den Besselaar, Armando Tripodi, Jørgen Jespersen, Pieter Meijer, Cornelis Kluft

    Background: There is a need for dependable quality assessment (QA) of the widely used CoaguChek point-of-care testing prothrombin time monitor. By use of the prescribed set of 5 CoaguChek certified international normalized ratio (INR) QA plasmas, we compared the reliability of the immediate QA of individual monitors described in the European Community–recommended Technology Implementation Plan with conventional external QA analysis. Methods: Experienced staff tested CoaguChek point-of-care monitors in routine use for controlling oral anticoagulant dosage at 9 Netherlands Thrombosis Service Centres. Testing was performed with both the certified CoaguChek INR for a set of 5 QA individual plasmas from the Eur Con Action on Anticoag (ECAA) and conventional external QA analysis. Results: Patients brought 523 CoaguChek monitors to our service centers for assessment. The proportion with unsatisfactory performance indicated by a 15% deviation from the ECAA set was compared with 15% deviation from overall median INR of all CoaguChek monitors in the survey, as in conventional QA analysis. The results were similar (20.3% and 18.5%, respectively). Interlot differences of CoaguChek test strips were detected, but the incidence of unsatisfactory performance was similar with both analyses, from 6.5% to 37.5% with the certified INR method and from 5.9% to 33.3% with the overall median analysis. Conclusions: The results validate the use of the European Action on Anticoagulation rapid single-instrument QA-specific procedure for CoaguChek users compared with the nonspecific conventional QA analysis that relies on deviation from the overall median INR.


  • Open Access

    Report on the Dutch Consensus Development Meeting for Implementation and Further Development of Population Screening for Colorectal Cancer Based on FOBT

    by M. de Visser, M. van Ballegooijen, S. M. Bloemers, S. J. H. van Deventer, J. B. M. J. Jansen, J. Jespersen, C. Kluft, G. A. Meijer, J. Stoker, G. A. de Valk, et al.

    A consensus development meeting was held to evaluate whether or not in the Netherlands all requirements were fulfilled for implementation of population screening with FOBT for colorectal cancer, or whether consensus was present that fulfilment by additional research or organisational actions could be obtained within 2–3 years. There was consensus that all classical Wilson and Jungner (1968) criteria, and six additional ones added more recently, had already been fulfilled or could be fulfilled within 2–3 years. Consequently, it was concluded that a national population screening for colorectal cancer should be implemented and carried out in the Netherlands in line with current national and European cancer screening programmes. A list of organisational actions to be taken was established. Research that is needed before the actual national launch of the screening within 2–3 years has been defined. Priorities have to be set for research and organisational actions for the coming 2–3 years for the implementation of population screening. In addition, research suggestions have been defined for the next 10–15 years for evaluation and/or improvement of implemented FOBT screening, and for future screening methodology. It was considered essential that infrastructure for future research would be embedded in the screening programme. A project group to arrange this should be formed.


  • Open Access

    Identifying patients at risk of coronary vascular disease: the potential role of inflammatory markers

    by C Kluft, Gaubius Laboratory

    Inflammation is intimately involved in the pathogenesis of cardiovascular disease (CVD). The measurement of inflammatory markers may be a potent method for identifying individuals with increased inflammation at risk of future cardiovascular events. High-sensitivity C-reactive protein (hs-CRP), one marker of inflammation, is a strong independent predictor of CVD and can be used to identify individuals at increased risk who would otherwise be missed if standard lipid measurements only were used. Furthermore, CRP may actively participate in the pathogenic progression of atherosclerotic disease by activating complement, inducing synthesis of tissue factor, influencing nitric oxide levels, and enhancing foam cell uptake of low-density lipoprotein cholesterol. Simple, inexpensive methods for measuring hs-CRP are commercially available, making the measurement of CRP levels feasible in clinical settings. Together, these data suggest that the ability to accurately predict CVD risk may be significantly increased by including CRP measurements in risk assessment models. In addition, the identification of increased inflammation suggests that rational therapy should be applied and favours treatments with anti-inflammatory action.


    • 1 July 2003
      • Vol. 90  (1) , 92-100

    Association between thrombin-activatable fibrinolysis inhibitor (TAFI) and clinical outcome in patients with unstable angina pectoris.

    by Geert-Jan Brouwers, Frank W G Leebeek, Michael W T Tanck, J Wouter Jukema, Cornelis Kluft, Moniek P M De Maat

    Decrease of fibrinolytic potential is considered to be a risk factor for arterial thrombosis. The recently described thrombin-activatable fibrinolysis inhibitor (TAFI) attenuates fibrinolysis by cleaving of the C-terminal lysine residues from fibrin, thereby inhibiting tPA mediated plasminogen activation. The role of plasma TAFI antigen (Ag) levels and gene polymorphisms in arterial thrombosis is still not elucidated. In this prospective study, the association between plasma TAFI Ag levels and the TAFI gene polymorphisms, Ala147Thr, Thr325Ile and -438A/G, with refractory unstable angina pectoris (UAP) was determined. The study population consisted of 209 patients with UAP of whom 76 were refractory and 133 non-refractory to medical treatment. In the same study population the contribution of these polymorphisms to plasma TAFI Ag levels was determined. Plasma TAFI Ag levels were significantly higher in non-refractory patients compared to refractory patients (geometric mean 114.4 and 105.6 U/dl respectively, p=0.042). Plasma TAFI Ag levels in the lowest quartile resulted in a 2.6 fold (95% confidence interval 1.2-5.9) increased risk for refractory UAP compared to plasma TAFI Ag levels in the upper quartile. The three studied TAFI polymorphisms had an independent and additive effect on plasma TAFI Ag levels. However, no significant association between the individual TAFI polymorphisms and refractiveness was observed. In conclusion, in this study population plasma TAFI Ag levels are significantly correlated with refractiveness in patients with UAP. Furthermore, all three polymorphisms contribute independently to plasma TAFI Ag levels, but not to refractiveness.


  • Local tissue factor pathway inhibitor release in the human forearm

    by Jacobus Burggraaf, Rik C. Schoemaker, Adam F. Cohen, Cornelis Kluft, Stanley Chia, David J. Webb, David E. Newby, Michiel J. B. Kemme

    Nineteen healthy men received unilateral brachial artery infusions of either unfractioned heparin (0.3-100 IU/min), saline or the endothelium-dependent vasodilators substance P (2-8 pmol/min) and bradykinin (100-1000 pmol/min), and the endothelium-independent vasodilator sodium nitroprusside (2-8 µg/min). Heparin caused a dose-dependent increase in plasma TFPI concentrations in both arms (ANOVA, p <0.0001). Estimated net forearm TFPI release was 7 ± 16, 29 ± 20 and 138 ± 72 ng/100 mL tissue/min during 10, 30 and 100 IU/min of heparin respectively (ANOVA, p <0.0001). Compared to the systemic circulation, the forearm sensitivity to heparin induced TFPI release was 3.6-fold lower (166 ± 67 ng/IU vs. 596 ± 252 ng/IU: t-test, p = 0.004). Substance P, bradykinin and sodium nitroprusside all caused substantial dose-dependent increases in blood flow (ANOVA, p <0.001 for all) without affecting plasma TFPI concentrations. There are important regional differences in endothelial TFPI release, with the forearm circulation being relatively insensitive to heparin.