DKDoron Kopelman

Doron Kopelman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Doron Kopelman has a total of 53 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The management of sportsman’s groin hernia in professional and amateur soccer players: a revised concept

    by D. Kopelman, U. Kaplan, O. A. Hatoum, N. Abaya, D. Karni, A. Berber, P. Sharon, B. Peskin

    Chronic groin pain appears in athletes with a diverse etiology. In a select few, it can be defined as a sportsman’s hernia, that may be related, among other pathologies, to weakness of the posterior inguinal wall and may successfully respond to surgery. Surgical repair of the sportsman’s hernia is associated with good functional outcomes, if the diagnosis is based on meticulous examination and follows a simple selection flowchart. Prospective case cohort study. The study assessed patients recruited from 2006 until the present assessed by a dedicated team with clinical and radiographic features of a sportsman’s hernia who had failed a specified period of conservative therapies. Surgery was performed using a tension-free mesh open inguinal hernia repair. Of 246 male patients with chronic groin pain, 51 underwent surgery (mean age 20.7 years, range 14–36 years) with 58 inguinal procedures performed. Of the operated group, seven underwent bilateral surgery with a direct hernia found in 9/58 operated sides (15.5 %), an indirect hernial sac in 8/58 (14 %) and a direct and indirect hernia being found in 3/58 (5 %) of operated sides. There was no post-operative morbidity (median follow-up 36.1 months; range 1–74 months), with two failures (3.45 % of operated sides). All other patients were asymptomatic, returned to full sports activity within 4.3 weeks (range 3–8 weeks) after surgery, and required no analgesics or further treatment. Selective surgical hernia repair, based on meticulous anamnesis and physical examination is effective in the management of chronic groin pain in athletes.


  • Endoluminal compression clip: full-thickness resection of the mesenteric bowel wall in a porcine model

    by Yael Kopelman, Peter D. Siersema, Yael Nir, Amir Szold, Amol Bapaye, Ori Segol, Ehud P. Willenz, Shlomo Lelcuk, Alexander Geller, Doron Kopelman


  • Biomimetic sealant based on gelatin and microbial transglutaminase: An initial in vivo investigation

    by Yi Liu, Doron Kopelman, Li‐Qun Wu, Karam Hijji, Ishay Attar, Orahn Preiss‐Bloom, Gregory F. Payne

    The potential of an in situ gel‐forming adhesive was examined as a hemostatic surgical sealant. The gel‐forming mechanism for this adhesive mimics the last stages of blood coagulation but uses nonblood proteins. Specifically, gelatin is used as the structural protein and a calcium‐independent microbial transglutaminase (mTG) is used as the crosslinking enzyme. In vitro burst pressure tests with porcine skin demonstrate that the gelatin‐mTG adhesive forms a gel within 30 min under moist conditions and this gel can restrain pressures of 200 mmHg. In vivo tests with a rat liver wound model showed that the gelatin‐mTG adhesive achieves complete hemostasis in 2.5 min and the gel (i.e., the biomimetic clot) offers substantial adhesive and cohesive strength. Complete hemostasis was also observed in 2.5 min after the gelatin‐mTG adhesive was applied to a briskly bleeding rat femoral artery wound. In a large animal porcine model, a femoral artery wound that resulted in extensive bleeding was sealed in 4 min by (i) clamping the artery for temporary hemostasis, (ii) removing excess blood, and (iii) applying the gelatin‐mTG adhesive. Thus, the biomimetic gelatin‐mTG adhesive may provide a simple, safe, and cost‐effective surgical sealant. © 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 2009


  • Magnetic resonance guided focused ultrasound surgery. Ablation of soft tissue at bone–muscle interface in a porcine model

    by D. Kopelman, Y. Inbar, A. Hanannel, R. M. Pfeffer, O. Dogadkin, D. Freundlich, B. Liberman, R. Catane

    Background  Pain management treatments of patients with bone metastases have either efficacy problems or significant side effects. Percutaneous radiofrequency ablation has recently proved to be of palliative value. Magnetic resonance guided focused ultrasound surgery (MRgFUS) uses focused ultrasonic energy to non‐invasively create a heat‐coagulated lesion deep within the body in a controlled, accurate manner. The surgeon can monitor and control energy deposition in real time. This technology represents a potential treatment modality in oncological surgery. We investigated the ability of two MRgFUS methods to accurately and safely target and ablate soft tissue at its interface with bone.Materials and methods  Heat‐ablated lesions were created by MRgFUS at the bone–muscle interface of 15 pigs. Two different methods of energy delivery were used. Temperature rise at the target adjacent to bone was monitored by real time MR thermal images. Results were evaluated by MRI (magnetic resonance imaging), nuclear scanning and by histopathological evaluation.Results  Soft tissue lesion sizes by both methods were in the range of 1–2 cm in diameter. Targeting the focus ‘behind’ the bone, achieved the same result with a single sonication only. Follow up MRI and histopathological examination of all lesions showed focal damage at its interface with bone and localized damage to the outer cortex on the side closer to the targeted tissue. There was no damage to non‐targeted tissue.Conclusion  MRgFUS by both energy deposition methods can be used to produce controlled well‐localized damage to soft tissue in close proximity to bone, with minimal collateral damage.


    • 2 November 2007
      • Vol. 92  (3) , 161-6

    Sentinel node detection in an animal study: evaluation of a new portable gamma camera.

    by Doron Kopelman, Ira Blevis, Galina Iosilevsky, Ossama A Hatoum, Assaf Zaretzki, Rona Shofti, Tal Salmon, Ora Israel, Moshe Hashmonai

    We tested the capacity of a newly developed portable gamma camera to precisely locate sentinel nodes by injecting a radiotracer. Two sets of experiments were performed on eight pigs under general anesthesia. 99mTc-Nanocolloid and dye complex was injected in the submuscular layer of the small bowel in the first set and subcutaneously in the knee region in the second set of experiments. Image acquisition of the sentinel nodes was performed with the Camera placed at various angles. A mosaic of images was obtained encompassing the injection sites, lymphatic pathways, and sentinel lymph nodes. Three-dimensional visualizations were obtained, allowing the precise location and complete excision of these nodes. The use of the portable gamma camera allowed the rapid visualization of the lymphatic pathways leading from the injection sites to the sentinel nodes and precise location of these nodes. The Camera was also useful to verify the complete removal of the labeled target tissues.


  • Compression gastrointestinal anastomosis

    by Doron Kopelman, Ossama A Hatoum, Boaz Kimmel, Leonid Monassevitch, Yael Nir, Shlomo Lelcuk, Micha Rabau, Amir Szold

    The creation of anastomoses between various parts of the GI tract is a major task in the daily practice of oncological, reconstructive and transplant surgery. The most widely used anastomosing techniques today involve the use of sutures or metal titanium staples. Both techniques involve foreign material penetrating the tissue and evoking localized inflammatory response, tissue injury and breaking of mucosal barriers that may facilitate bacterial growth within the anastomotic line, increasing the propensity to anastomotic-related morbidity. Different types of compression devices were successfully used clinically in the past. The history and evolving characteristics of this technology is reviewed. Nitinol-based solutions for the creation of compression anastomosis are evaluated as a possible potential for revolutionary impact on the current surgical methods and anastomosing technology in the alimentary tract and beyond.


  • Magnetic Resonance–Guided Focused Ultrasound Surgery for the Noninvasive Curative Ablation of Tumors and Palliative Treatments: A Review

    by Doron Kopelman, Moshe Papa

    This article reviews and discusses the up-to-date data on and feasibility of focused ultrasound surgery. This technique uses high-energy ultrasound beams that can be directed to penetrate through the skin and various soft tissues, focus on the target, and destroy tumors by increasing the temperature at the targeted tissue volume. The boundaries of the treatment area are sharply demarcated (focused) without causing damage to the surrounding organs. Although the idea of using sound waves to ablate tumors was first demonstrated in the 1940 s, only recent developments have enabled this technology to become more controlled and, hence, more feasible. The major breakthrough toward its clinical use came with coupling the thermal ablative process to advanced imaging. The development of magnetic resonance as the foundation to guide and evaluate the end results of focused ultrasound surgery treatment, the image guidance of the ultrasound beam, and the development of a reliable method for tissue temperature measurement and real-time feedback of the extent of tissue destruction have pushed this novel technology forward in oncological practice.