Arthur F. Gmitro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Arthur F. Gmitro has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
Andrew R. Rouse
College of Optical Sciences, University of Arizona, 1630 E University Blvd, Tucson, Arizona 85719, USA
15 shared publicationsAngelique Kano
University of Arizona, College of Optical Sciences and Department of Medical Imaging, Tucson, Arizona, USA
3 shared publicationsAnthony A. Tanbakuchi
College of Optical Sciences, University of Arizona, 1630 E. University Blvd., Tucson, AZ 85721, USA
3 shared publicationsHoussine Makhlouf
College of Optical Sciences, University of Arizona, 1630 East University Boulevard, Tucson, Arizona 85721, USA
3 shared publicationsKenneth D. Hatch
¶Department of Biomedical Engineering, University of Arizona, Tucson, AZ
3 shared publicationsMatthew D. Risi
College of Optical Sciences, University of Arizona; †University of Arizona Cancer Center; and Departments of ‡Medical Imaging, §Obstetrics and Gynecology, and ∥Pathology, College of Medicine, and ¶Department of Biomedical Engineering, University of Arizona, Tucson, AZ
3 shared publications
Latest Publications
- 23 July 2020
- Published by Optica Publishing Group in Applied Optics
- Vol. 59 (22) , G249-G254
Improvement in optical fiber bundle-based imaging using synchronized fiber motion
Image quality in fiber bundle-based imaging systems is inherently limited by the size and spacing of the individual fiber cores. The fiber bundle limits the achievable spatial resolution and superimposes a fixed pattern of signal variability across the image. To overcome these limitations, piezoelectric tubes were used to synchronously dither the fiber bundle on both ends. Experimental results using the dithering approach with a commercial fiber bundle showed a substantial decrease in fixed pattern noise and an increase in spatial resolution.
- 23 July 2020
- Published by Optica Publishing Group in Applied Optics
- Vol. 59 (22) , G249-G254
Improvement in optical fiber bundle-based imaging using synchronized fiber motion
Image quality in fiber bundle-based imaging systems is inherently limited by the size and spacing of the individual fiber cores. The fiber bundle limits the achievable spatial resolution and superimposes a fixed pattern of signal variability across the image. To overcome these limitations, piezoelectric tubes were used to synchronously dither the fiber bundle on both ends. Experimental results using the dithering approach with a commercial fiber bundle showed a substantial decrease in fixed pattern noise and an increase in spatial resolution.
- Open Access
- 1 February 2016
- Published by Elsevier in International Journal of Gynecological Cancer
- Vol. 26 (2) , 248-254
Pilot Clinical Evaluation of a Confocal Microlaparoscope for Ovarian Cancer Detection
- 1 February 2016
- Published by Elsevier in International Journal of Gynecological Cancer
- Vol. 26 (2) , 248-254
Open AccessPilot Clinical Evaluation of a Confocal Microlaparoscope for Ovarian Cancer Detection
- Open Access
- 29 January 2015
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 6 (2) , 639-650
Dynamic oxygenation measurements using a phosphorescent coating within a mammary window chamber mouse model
Phosphorescent lifetime imaging was employed to measure the spatial and temporal distribution of oxygen partial pressure in tissue under the coverslip of a mammary window chamber breast cancer mouse model. A thin platinum-porphyrin coating, whose phosphorescent lifetime varies monotonically with oxygen partial pressure, was applied to the coverslip surface. Dynamic temporal responses to induced modulations in oxygenation levels were measured using this approach.
- 29 January 2015
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 6 (2) , 639-650
Open AccessDynamic oxygenation measurements using a phosphorescent coating within a mammary window chamber mouse model
Phosphorescent lifetime imaging was employed to measure the spatial and temporal distribution of oxygen partial pressure in tissue under the coverslip of a mammary window chamber breast cancer mouse model. A thin platinum-porphyrin coating, whose phosphorescent lifetime varies monotonically with oxygen partial pressure, was applied to the coverslip surface. Dynamic temporal responses to induced modulations in oxygenation levels were measured using this approach.
- 23 December 2014
- Published by Optica Publishing Group in Applied Optics
- Vol. 54 (1) , 101-113
Analysis of multimode fiber bundles for endoscopic spectral-domain optical coherence tomography
A theoretical analysis of the use of a fiber bundle in spectral-domain optical coherence tomography (OCT) systems is presented. The fiber bundle enables a flexible endoscopic design and provides fast, parallelized acquisition of the OCT data. However, the multimode characteristic of the fibers in the fiber bundle affects the depth sensitivity of the imaging system. A description of light interference in a multimode fiber is presented along with numerical simulations and experimental studies to illustrate the theoretical analysis.
- 23 December 2014
- Published by Optica Publishing Group in Applied Optics
- Vol. 54 (1) , 101-113
Analysis of multimode fiber bundles for endoscopic spectral-domain optical coherence tomography
A theoretical analysis of the use of a fiber bundle in spectral-domain optical coherence tomography (OCT) systems is presented. The fiber bundle enables a flexible endoscopic design and provides fast, parallelized acquisition of the OCT data. However, the multimode characteristic of the fibers in the fiber bundle affects the depth sensitivity of the imaging system. A description of light interference in a multimode fiber is presented along with numerical simulations and experimental studies to illustrate the theoretical analysis.
- Open Access
- 20 November 2014
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 19 (11) , 116010
Confocal microlaparoscope for imaging the fallopian tube
Recent evidence suggests that ovarian cancer can originate in the fallopian tube. Unlike many other cancers, poor access to the ovary and fallopian tubes has limited the ability to study the progression of this deadly disease and to diagnosis it during the early stage when it is most amenable to therapy. A rigid confocal microlaparoscope system designed to image the epithelial surface of the ovary in vivo was previously reported. A new confocal microlaparoscope with an articulating distal tip has been developed to enable in vivo access to human fallopian tubes. The new microlaparoscope is compatible with 5-mm trocars and includes a 2.2-mm-diameter articulating distal tip consisting of a bare fiber bundle and an automated dye delivery system for fluorescence confocal imaging. This small articulating device should enable the confocal microlaparoscope to image early stage ovarian cancer arising inside the fallopian tube. Ex vivo images of animal tissue and human fallopian tube using the new articulating device are presented along with in vivo imaging results using the rigid confocal microlaparoscope system.
- 20 November 2014
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 19 (11) , 116010
Open AccessConfocal microlaparoscope for imaging the fallopian tube
Recent evidence suggests that ovarian cancer can originate in the fallopian tube. Unlike many other cancers, poor access to the ovary and fallopian tubes has limited the ability to study the progression of this deadly disease and to diagnosis it during the early stage when it is most amenable to therapy. A rigid confocal microlaparoscope system designed to image the epithelial surface of the ovary in vivo was previously reported. A new confocal microlaparoscope with an articulating distal tip has been developed to enable in vivo access to human fallopian tubes. The new microlaparoscope is compatible with 5-mm trocars and includes a 2.2-mm-diameter articulating distal tip consisting of a bare fiber bundle and an automated dye delivery system for fluorescence confocal imaging. This small articulating device should enable the confocal microlaparoscope to image early stage ovarian cancer arising inside the fallopian tube. Ex vivo images of animal tissue and human fallopian tube using the new articulating device are presented along with in vivo imaging results using the rigid confocal microlaparoscope system.
- Open Access
Design and Performance of a Multi-Point Scan Confocal Microendoscope
Confocal fluorescence microendoscopy provides high-resolution cellular-level imaging via a minimally invasive procedure, but requires fast scanning to achieve real-time imaging in vivo. Ideal confocal imaging performance is obtained with a point scanning system, but the scan rates required for in vivo biomedical imaging can be difficult to achieve. By scanning a line of illumination in one direction in conjunction with a stationary confocal slit aperture, very high image acquisition speeds can be achieved, but at the cost of a reduction in image quality. Here, the design, implementation, and experimental verification of a custom multi-point aperture modification to a line-scanning multi-spectral confocal microendoscope is presented. This new design improves the axial resolution of a line-scan system while maintaining high imaging rates. In addition, compared to the line-scanning configuration, previously reported simulations predicted that the multi-point aperture geometry greatly reduces the effects of tissue scatter on image quality. Experimental results confirming this prediction are presented.
Open AccessDesign and Performance of a Multi-Point Scan Confocal Microendoscope
Confocal fluorescence microendoscopy provides high-resolution cellular-level imaging via a minimally invasive procedure, but requires fast scanning to achieve real-time imaging in vivo. Ideal confocal imaging performance is obtained with a point scanning system, but the scan rates required for in vivo biomedical imaging can be difficult to achieve. By scanning a line of illumination in one direction in conjunction with a stationary confocal slit aperture, very high image acquisition speeds can be achieved, but at the cost of a reduction in image quality. Here, the design, implementation, and experimental verification of a custom multi-point aperture modification to a line-scanning multi-spectral confocal microendoscope is presented. This new design improves the axial resolution of a line-scan system while maintaining high imaging rates. In addition, compared to the line-scanning configuration, previously reported simulations predicted that the multi-point aperture geometry greatly reduces the effects of tissue scatter on image quality. Experimental results confirming this prediction are presented.
- Open Access
- 1 July 2014
- Published by Taylor & Francis in BioTechniques
- Vol. 57 (1) , 45-50
Multi-Modality Imaging of a Murine Mammary Window Chamber for Breast Cancer Research
Window chamber models have been developed and utilized as a means to study the complex microenvironment in which cancers develop, proliferate, and metastasize in small animals. Here we utilize rapid prototyping printer technology to construct a new plastic orthotopic mammary window chamber that is compatible with magnetic resonance imaging, nuclear imaging, and optical imaging. Optical imaging allows for high-resolution cellular and molecular level analysis of tissues; magnetic resonance imaging provides quantitative measures of tumor size, perfusion, diffusion, fat/water content relaxation parameters; and a nuclear imaging technique, called the Beta Imager, supports functional and metabolic imaging. Our demonstration of the multiple imaging capabilities of this model suggests that it can be used as a powerful platform for studying basic cancer biology and developing new cancer therapies.
- 1 July 2014
- Published by Taylor & Francis in BioTechniques
- Vol. 57 (1) , 45-50
Open AccessMulti-Modality Imaging of a Murine Mammary Window Chamber for Breast Cancer Research
Window chamber models have been developed and utilized as a means to study the complex microenvironment in which cancers develop, proliferate, and metastasize in small animals. Here we utilize rapid prototyping printer technology to construct a new plastic orthotopic mammary window chamber that is compatible with magnetic resonance imaging, nuclear imaging, and optical imaging. Optical imaging allows for high-resolution cellular and molecular level analysis of tissues; magnetic resonance imaging provides quantitative measures of tumor size, perfusion, diffusion, fat/water content relaxation parameters; and a nuclear imaging technique, called the Beta Imager, supports functional and metabolic imaging. Our demonstration of the multiple imaging capabilities of this model suggests that it can be used as a powerful platform for studying basic cancer biology and developing new cancer therapies.
- Open Access
- 1 January 2013
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 18 (1) , 016013
Ultrathin single-channel fiberscopes for biomedical imaging
Ultrathin flexible fiberscopes typically have separate illumination and imaging channels and are available in diameters ranging from 0.5 to 2.5 mm. Diameters can potentially be reduced by combining the illumination and imaging paths into a single fiberoptic channel. Single-channel fiberscopes must incorporate a system to minimize Fresnel reflections from air–glass interfaces within the common illumination and detection path. The Fresnel reflection at the proximal surface of the fiber bundle is particularly problematic. This paper describes and compares methods to reduce the background signal from the proximal surface of the fiber bundle. Three techniques are evaluated: (1) antireflective (AR)-coating the proximal face of the fiber, (2) incorporating crossed polarizers into the light path, and (3) a novel technique called numerical aperture sharing, whereby a portion of the image numerical aperture is devoted to illumination and a portion to detection.
- 1 January 2013
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 18 (1) , 016013
Open AccessUltrathin single-channel fiberscopes for biomedical imaging
Ultrathin flexible fiberscopes typically have separate illumination and imaging channels and are available in diameters ranging from 0.5 to 2.5 mm. Diameters can potentially be reduced by combining the illumination and imaging paths into a single fiberoptic channel. Single-channel fiberscopes must incorporate a system to minimize Fresnel reflections from air–glass interfaces within the common illumination and detection path. The Fresnel reflection at the proximal surface of the fiber bundle is particularly problematic. This paper describes and compares methods to reduce the background signal from the proximal surface of the fiber bundle. Three techniques are evaluated: (1) antireflective (AR)-coating the proximal face of the fiber, (2) incorporating crossed polarizers into the light path, and (3) a novel technique called numerical aperture sharing, whereby a portion of the image numerical aperture is devoted to illumination and a portion to detection.
- Open Access
- 1 January 2012
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 17 (4) , 0460041-0460046
Error analysis of ratiometric imaging of extracellular pH in a window chamber model
Ratiometric fluorescence-imaging technique is commonly used to measure extracellular pH in tumors and surrounding tissue within a dorsal skin-fold window chamber. Using a pH-sensitive fluorophore such as carboxy SNARF-1 one can measure pH distributions with high precision. However, it is often observed that the measured pH is lower than expected, with a bias that varies from one image to another. A comprehensive analysis of possible error sources is presented. These error sources include photon noise, estimator bias, instrument errors, temperature, and calibration errors from biological factors.
- 1 January 2012
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 17 (4) , 0460041-0460046
Open AccessError analysis of ratiometric imaging of extracellular pH in a window chamber model
Ratiometric fluorescence-imaging technique is commonly used to measure extracellular pH in tumors and surrounding tissue within a dorsal skin-fold window chamber. Using a pH-sensitive fluorophore such as carboxy SNARF-1 one can measure pH distributions with high precision. However, it is often observed that the measured pH is lower than expected, with a bias that varies from one image to another. A comprehensive analysis of possible error sources is presented. These error sources include photon noise, estimator bias, instrument errors, temperature, and calibration errors from biological factors.
- 1 May 2011
- Published by Elsevier in Gastroenterology
- Vol. 140 (5)
Confocal Microscopy for the Confirmation of Tumor Free Surgical Margins in Pancreatic Cancer
- 1 May 2011
- Published by Elsevier in Gastroenterology
- Vol. 140 (5)
Confocal Microscopy for the Confirmation of Tumor Free Surgical Margins in Pancreatic Cancer