Craig P. Fischer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Craig P. Fischer has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Barbara L. Bass
4 shared publications- Bridget N. Fahy
The Methodist Hospital, Weill Cornell Medical College
3 shared publications Bababhai Patel
2 shared publicationsJames C. Hart
2 shared publicationsJessica Shen
2 shared publicationsJonathan Batiller
2 shared publications
Latest Publications
- 1 September 2013
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 217 (3) , 385-393
A Prospective, Randomized, Controlled Trial of the Efficacy and Safety of Fibrin Pad as an Adjunct to Control Soft Tissue Bleeding During Abdominal, Retroperitoneal, Pelvic, and Thoracic Surgery
This study evaluated the hemostatic effectiveness and safety of Fibrin Pad (Omrix Biopharmaceuticals Ltd.) vs absorbable hemostat in patients undergoing nonemergent surgery. Fibrin Pad is a topical absorbable hemostat designed to be effective in a variety of soft tissues and across multiple bleeding intensities. Patients 18 years and older, requiring abdominal, retroperitoneal, pelvic, or thoracic (noncardiac) surgery and with an appropriate soft-tissue target bleeding site (TBS), were randomized to receive Fibrin Pad or absorbable hemostat (NCT00658723). Patients were stratified by bleeding severity at the TBS. Assessments included percentage of patients achieving hemostasis at 4 minutes after randomization with no rebleeding requiring treatment during the subsequent 6 minutes (primary endpoint), proportion of patients achieving hemostasis at 10 minutes, and incidence of treatment failure. On the primary endpoint, 98.3% of patients with Fibrin Pad and 53.3% with absorbable hemostat achieved hemostasis at 4 minutes (p < 0.0001). The treatment differential was magnified (efficacy was maintained with Fibrin Pad but decreased with absorbable hemostat) with increasing bleeding intensity: in patients with mild bleeding, 100.0% vs 80.0% achieved hemostasis with Fibrin Pad and absorbable hemostat (p = 0.03), respectively; rates were 96.6% vs 26.7%, respectively (p < 0.0001) with moderate bleeding. Percentages of patients who achieved hemostasis at 10 minutes were: Fibrin Pad, 98.3% and absorbable hemostat, 73.3% (p < 0.0001). Incidences of adverse events were comparable between groups. Fibrin Pad is superior to absorbable hemostat (SURGICEL Original Absorbable Hemostat [Ethicon]) in soft-tissue bleeding control and is safe and effective as an adjunct for rapidly and reliably achieving hemostasis for soft-tissue bleeding during surgery.
- 1 September 2013
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 217 (3) , 385-393
A Prospective, Randomized, Controlled Trial of the Efficacy and Safety of Fibrin Pad as an Adjunct to Control Soft Tissue Bleeding During Abdominal, Retroperitoneal, Pelvic, and Thoracic Surgery
This study evaluated the hemostatic effectiveness and safety of Fibrin Pad (Omrix Biopharmaceuticals Ltd.) vs absorbable hemostat in patients undergoing nonemergent surgery. Fibrin Pad is a topical absorbable hemostat designed to be effective in a variety of soft tissues and across multiple bleeding intensities. Patients 18 years and older, requiring abdominal, retroperitoneal, pelvic, or thoracic (noncardiac) surgery and with an appropriate soft-tissue target bleeding site (TBS), were randomized to receive Fibrin Pad or absorbable hemostat (NCT00658723). Patients were stratified by bleeding severity at the TBS. Assessments included percentage of patients achieving hemostasis at 4 minutes after randomization with no rebleeding requiring treatment during the subsequent 6 minutes (primary endpoint), proportion of patients achieving hemostasis at 10 minutes, and incidence of treatment failure. On the primary endpoint, 98.3% of patients with Fibrin Pad and 53.3% with absorbable hemostat achieved hemostasis at 4 minutes (p < 0.0001). The treatment differential was magnified (efficacy was maintained with Fibrin Pad but decreased with absorbable hemostat) with increasing bleeding intensity: in patients with mild bleeding, 100.0% vs 80.0% achieved hemostasis with Fibrin Pad and absorbable hemostat (p = 0.03), respectively; rates were 96.6% vs 26.7%, respectively (p < 0.0001) with moderate bleeding. Percentages of patients who achieved hemostasis at 10 minutes were: Fibrin Pad, 98.3% and absorbable hemostat, 73.3% (p < 0.0001). Incidences of adverse events were comparable between groups. Fibrin Pad is superior to absorbable hemostat (SURGICEL Original Absorbable Hemostat [Ethicon]) in soft-tissue bleeding control and is safe and effective as an adjunct for rapidly and reliably achieving hemostasis for soft-tissue bleeding during surgery.
- 25 August 2011
- Published by SAGE Publications in Clinical and Applied Thrombosis/Hemostasis
- Vol. 17 (6) , 572-577
A Randomized Trial of Aprotinin-Free Fibrin Sealant Versus Absorbable Hemostat
Background: This study evaluated the safety and hemostatic effectiveness of a tranexamic acid- and aprotinin-free fibrin sealant versus an absorbable hemostat in soft tissue during elective retroperitoneal or intra-abdominal surgery. Materials and Methods: This randomized, active-controlled, multicenter study enrolled patients who were undergoing elective retroperitoneal or intra-abdominal surgery and required adjunctive hemostatic measures at the target bleeding site (TBS). Patients were randomized (time = 0 minutes) to receive fibrin sealant or absorbable hemostat. The primary endpoint was the absence of bleeding at the TBS at 10 minutes. Secondary endpoints included the absence of bleeding at 4 and 7 minutes and the incidence of treatment failure (bleeding at 10 minutes or brisk bleeding requiring additional hemostatic measures), and the incidence of complications potentially related to bleeding. Adverse events were assessed. Results: Patients (N = 124) were randomized to receive fibrin sealant (n = 62) or absorbable hemostat (n = 62). A higher percentage of patients who received fibrin sealant versus absorbable hemostat achieved hemostasis within 10 minutes (95.2% vs 82.3%; 95% CI, 1.02-1.35) and also at 4 (74.2% vs 54.8%; 95% CI, 1.04-1.80) and 7 (90.3% vs 77.4%; 95% CI, 1.00-1.39) minutes. A lower incidence of treatment failure was observed for patients receiving fibrin sealant. Similar incidences of adverse events and complications potentially related to bleeding were observed. Conclusions: This tranexamic acid- and aprotinin-free fibrin sealant is safe and effective for achieving hemostasis in soft tissue during elective retroperitoneal or intra-abdominal surgery.
- 25 August 2011
- Published by SAGE Publications in Clinical and Applied Thrombosis/Hemostasis
- Vol. 17 (6) , 572-577
A Randomized Trial of Aprotinin-Free Fibrin Sealant Versus Absorbable Hemostat
Background: This study evaluated the safety and hemostatic effectiveness of a tranexamic acid- and aprotinin-free fibrin sealant versus an absorbable hemostat in soft tissue during elective retroperitoneal or intra-abdominal surgery. Materials and Methods: This randomized, active-controlled, multicenter study enrolled patients who were undergoing elective retroperitoneal or intra-abdominal surgery and required adjunctive hemostatic measures at the target bleeding site (TBS). Patients were randomized (time = 0 minutes) to receive fibrin sealant or absorbable hemostat. The primary endpoint was the absence of bleeding at the TBS at 10 minutes. Secondary endpoints included the absence of bleeding at 4 and 7 minutes and the incidence of treatment failure (bleeding at 10 minutes or brisk bleeding requiring additional hemostatic measures), and the incidence of complications potentially related to bleeding. Adverse events were assessed. Results: Patients (N = 124) were randomized to receive fibrin sealant (n = 62) or absorbable hemostat (n = 62). A higher percentage of patients who received fibrin sealant versus absorbable hemostat achieved hemostasis within 10 minutes (95.2% vs 82.3%; 95% CI, 1.02-1.35) and also at 4 (74.2% vs 54.8%; 95% CI, 1.04-1.80) and 7 (90.3% vs 77.4%; 95% CI, 1.00-1.39) minutes. A lower incidence of treatment failure was observed for patients receiving fibrin sealant. Similar incidences of adverse events and complications potentially related to bleeding were observed. Conclusions: This tranexamic acid- and aprotinin-free fibrin sealant is safe and effective for achieving hemostasis in soft tissue during elective retroperitoneal or intra-abdominal surgery.
- 1 May 2011
- Published by Elsevier in Gastroenterology
- Vol. 140 (5)
Laparoscopic Pancreaticoduodenectomy for Cancer: Margin Status, Adequacy of Resection and 90 Day Outcomes
- 1 May 2011
- Published by Elsevier in Gastroenterology
- Vol. 140 (5)
Laparoscopic Pancreaticoduodenectomy for Cancer: Margin Status, Adequacy of Resection and 90 Day Outcomes
- 31 May 2009
- Published by Elsevier in Gastroenterology
- Vol. 136 (5) , A-886-886
1032 Fine Needle Aspiration Cytology from Pancreatic Cysts-Limited Utility in Surgical Decision Making
- 31 May 2009
- Published by Elsevier in Gastroenterology
- Vol. 136 (5) , A-886-886
1032 Fine Needle Aspiration Cytology from Pancreatic Cysts-Limited Utility in Surgical Decision Making
- 30 April 2008
- Published by Elsevier in Gastroenterology
- Vol. 134 (4) , A-858-858
1030 Optimizing Outcome Measurement in Pancreatic Surgery: Can NSQIP Measure Up?
- 30 April 2008
- Published by Elsevier in Gastroenterology
- Vol. 134 (4) , A-858-858
1030 Optimizing Outcome Measurement in Pancreatic Surgery: Can NSQIP Measure Up?