BLBritta Lindholm-Sethson

Britta Lindholm-Sethson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Britta Lindholm-Sethson has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Aspects on mediated glucose oxidation at a supported cubic phase

    by Mahdi Shahmohammadi Aghbolagh, Mohammad Yaser Khani Meynaq, Kenichi Shimizu, Britta Lindholm-Sethson


  • Investigation of metal ion interaction with a lipid cubic phase using electrochemical impedance spectroscopy

    by Mohammad Yaser Khani Meynaq, Kenichi Shimizu, Mahdi Shahmohammadi Aghbolagh, Solomon Tesfalidet, Britta Lindholm-Sethson


  • Non‐invasive identification of melanoma with near‐infrared and skin impedance spectroscopy

    by Ida Bodén, Josefina Nyström, Bertil Lundskog, Virginia Zazo, Paul Geladi, Britta Lindholm‐Sethson, Peter Naredi

    Background/purpose: An early diagnosis of cutaneous malignant melanoma is of high importance for good prognosis. An objective, non‐invasive instrument could improve the diagnostic accuracy of melanoma and decrease unnecessary biopsies. The aim of this study was to investigate the use of Near‐infrared and skin impedance spectroscopy in combination as a tool to distinguish between malignant and benign skin tumours.Methods: Near‐infrared and skin impedance spectra were collected in vivo on 50 naevi or suspect melanomas prior to excision. Received data were analysed using multivariate techniques and the results were compared to histopathology analyses of the tumours. A total of 12 cutaneous malignant melanomas, 19 dysplastic naevi and 19 benign naevi were included in the study.Results: The observed sensitivity and specificity of the proposed method were 83% and 95%, respectively, for malignant melanoma.Conclusion: The results indicate that the combination of near‐infrared and skin impedance spectroscopy is a promising tool for non‐invasive diagnosis of suspect cutaneous malignant melanomas.


  • NIR and skin impedance spectroscopic measurements for studying the effect of coffee and alcohol on skin, and dysplastic naevi

    by Ida Bodén, Josefina Nyström, Paul Geladi, Peter Naredi, Britta Lindholm‐Sethson

    Background/purpose Near infrared and impedance spectroscopy can be used for clinical skin measurements and need to be evaluated for possible confounding factors; (i) are skin conditions of the patient and the subsequent skin measurements influenced by alcohol and/or coffee consumption and (ii) are measurements of dysplastic naevi (DN) reproducible over time and significantly different compared to reference skin. Methods Near infrared and skin impedance spectroscopic data were analysed multivariately. In the first study, the skin characteristics of 15 healthy individuals were examined related to body location, gender, individual differences, and consumption of coffee or alcohol. The second study included five patients diagnosed with dysplastic naevi syndrome. Measurements were taken on DN and reference skin over time. Results In the first study, body location and gender had a major influence on measurement scores. Inter-individual skin characteristics and coffee or alcohol effects on skin characteristics were of minor importance. In the second study, it was shown that DN can be differentiated from reference skin and the measurements are stable over time. Conclusions Moderate consumption of alcohol and coffee did not influence the results of the measurements. It is possible to follow, stable or changed, characteristics of DN over time.


  • In vivo skin measurements with a novel probe head for simultaneous skin impedance and near‐infrared spectroscopy

    by Ida Bodén, William Larsson, David Nilsson, Erik Forssell, Peter Naredi, Britta Lindholm‐Sethson

    Near-infrared (NIR) spectroscopy and skin impedance (IMP) measurements are useful techniques for objective diagnostics of various skin diseases. Here, we present a combined probe head for simultaneous, time-saving NIR spectroscopy and skin impedance measurements. The probe also ensures that both measurements are performed under equal conditions and at the same skin location. Finite element method simulations were performed for evaluation of the impedance. In vivo skin measurements were performed and combined NIR and impedance spectra were analysed by means of multivariate methods with respect to body location, age and gender. The classification rate was determined by a planar discriminant analysis. Reproducibility was investigated by calculation of scatter values and statistical significance between overlapping groups was assessed by the calculation of intra-model distances, q. The novel probe yielded rapid reproducible results and was easy to manage. Significant differences between skin locations and to a lesser extent age groups and gender were demonstrated. With the novel probe, statistically significant differences between overlapping classes in score plots can be confirmed by calculating intra-model distances. The influence of molecular differences in the skin at different body locations is larger than the influence of gender or age and therefore relevant reference measurements are discussed.


  • Electrochemical impedance spectroscopy in label-free biosensor applications: multivariate data analysis for an objective interpretation

    by Britta Lindholm-Sethson, Josefina Nyström, Martin Malmsten, Lovisa Ringstad, Andrew Nelson, Paul Geladi

    Electrochemical impedance spectroscopy plays an important role in biosensor science thanks to the possibility of finding specific information from processes with different kinetics at a chosen electrode potential in one experiment. In this paper we briefly discuss label-free impedimetric biosensors described in the literature. A novel method for neutral interpretation of impedance data is presented that includes complex number chemometrics. Three examples are given based on impedance measurements on synthetic biomembranes, in this case a lipid monolayer deposited on a mercury electrode. The interaction of various compounds with the monomolecular lipid layer is illustrated with the following: (1) different concentrations of magainin (Geladi et al. in Proc. Int. Fed. Med. Biomed. Eng. 9:219–220, 2005); (2) different derivatives of gramicidin A (Lindholm-Sethson et al. in Langmuir 24:5029–5032, 2007), and (3) an antimicrobial peptide (Ringstad et al. in Langmuir 24:208–216, 2008).


  • NOPAPROD Non-Parametric Testing on Projections from Multivariate Data. Applications to near Infrared Spectroscopy in Clinical Studies

    by Josefina Nyström, Britta Lindholm-Sethson, Paul Geladi

    Clinical studies may be carried out using non-invasively collected near infrared spectra of patient skin. Two problems encountered are: (1) data reduction to go from thousands of wavelengths to some clinically relevant estimator and (2) getting statistical significance from noisy data with sometimes very skewed distributions. The problem of data reduction can usually be solved by principal component analysis to get a few meaningful components. In the space spanned by these components, a direction of discrimination may have to be found, typically discrimination between treated and control. A visual difference in a score plot is often not enough; statistical significance has to be demonstrated. Once a univariate estimator is found, non-parametric testing can show significant differences, even if the data are noisy and have an unknown and skewed distribution. The NOPRAPOD method com bines the actions of finding a direction in a reduced data space and performing the non-parametric significance testing by producing a disk of significance. Two examples are included. Example one is from a study of diabetes-related neuropathy where it is shown that significant differences show up in the NIR spectra. Example two is from a study of post-operative radiation treatment of breast cancer patients, where it is shown that radiation effects (erythema) and the effect of lotion can be determined with an indication of significance from the NIR spectra.


  • Cubic phases in biosensing systems

    by Ewa Nazaruk, Renata Bilewicz, Göran Lindblom, Britta Lindholm-Sethson

    Incorporation of membrane proteins with retained activity in artificial membranes for use in membrane-based sensors has attracted scientists for decades. This review briefly summarises general concepts on relevant cubic phases with and without incorporated proteins and provides some insight into the development of biosensors where bicontinuous cubic phases are used for incorporation of an enzyme. Some new data on impedance characterisation of a supported cubic phase are also shown. An efficient membrane-based electrochemical biosensor requires that the analyte has free access to the immobilised membrane protein and that regeneration of the catalysing enzyme is fast. Long-term stability of the system is also necessary for the biosensor to find applications outside the research laboratory. These basic concepts are discussed in the review along with presentation of those biosensing systems based on cubic phases that are reported in the literature.


  • Characterization of healthy skin using near infrared spectroscopy and skin impedance

    by Ida Bodén, David Nilsson, Peter Naredi, Britta Lindholm-Sethson

    Near infrared spectroscopy (NIR) and skin impedance (IMP) spectroscopy are two methods suggested for diagnoses of diseases inducing adverse effects in skin. The reproducibility of these methods and their potential value in non-invasive diagnostics were investigated. Measurements were performed in vivo on healthy skin at five anatomic body sites on eight young women. partial least squares discriminant analysis showed that both methods were useful for classification of the skin characteristics at the sites. Inter-individually the NIR model gave 100% correct classification while the IMP model provided 92%. Intra-individually the NIR model gave 88% correct classification whereas the IMP model did not provide any useful classification. The correct classification was increased to 93% when both datasets were combined, which demonstrates the value of adding information. Partial least squares discriminant analysis gave 72% correct predictions of skin sites while the combined model slightly improved to 73%.


  • Effects of pH and fluoride concentration on the corrosion of titanium

    by B. Lindholm‐Sethson, B.I. Ardlin

    The aim of this investigation was to confirm and summarize the corrosion behavior of titanium in saline solution at different pH and fluoride concentration, and to characterize the surface films and the stability of a passive and aged titanium surface using open circuit potential measurements, electrochemical impedance spectroscopy, and anodic polarization curves. The results from the electrochemical measurements were related to titanium released after 2‐min brushing with saline solutions with different pH and fluoride concentration, that is, simulating tooth brushing with fluoride containing prophylactic substances. Titanium was analyzed using atomic adsorption spectrophotometry. The pH in the saline solution was varied between 4 and 7 with additions of sodium fluoride up to 1.0 wt %. The presence of fluoride in solution was unfavorable for the stability of titanium and led to corrosion and the release of titanium especially at low pH. The combination of low pH and presence of fluoride ions in solution destroyed a passive film on the titanium surface even after aging for 170 h in neutral saline solution. The results do not necessarily imply the occurrence of biological soft tissue related effects even if a physical contact between titanium and the surrounding milieu is prevalent. To provide a general understanding of electrochemical techniques in biomaterial research, much effort was put in the qualitative description of the results, with the intention to provide a broader understanding of especially the impedance method to other researchers. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res, 2008