Oliver Hassall
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Oliver Hassall has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Imelda Bates
Centre for Capacity Research, Liverpool School of Tropical Medicine, Liverpool, England
5 shared publications - Kathryn Maitland
KEMRI Wellcome Trust Research Programme, Kilifi, Kenya
5 shared publications Douglas Denje
Coast Provincial General Hospital, Mombasa, Kenya
4 shared publicationsKishor Mandaliya
Coast Provincial General Hospital, Mombasa, Kenya; Regional Blood Transfusion Centre, Mombasa, Kenya
4 shared publicationsKongo Wambua
Regional Blood Transfusion Centre, Mombasa, Kenya
4 shared publicationsLewa Pole
3 shared publications
Latest Publications
- Open Access
- 1 February 2016
- Published by Elsevier in International Journal of Infectious Diseases
- Vol. 43, 90-94
Syphilis screening practices in blood transfusion facilities in Ghana
- 1 February 2016
- Published by Elsevier in International Journal of Infectious Diseases
- Vol. 43, 90-94
Open AccessSyphilis screening practices in blood transfusion facilities in Ghana
- Open Access
- 1 March 2015
- Published by Elsevier in The Lancet Haematology
- Vol. 2 (3) , e101-e107
Safety and efficacy of allogeneic umbilical cord red blood cell transfusion for children with severe anaemia in a Kenyan hospital: an open-label single-arm trial
- 1 March 2015
- Published by Elsevier in The Lancet Haematology
- Vol. 2 (3) , e101-e107
Open AccessSafety and efficacy of allogeneic umbilical cord red blood cell transfusion for children with severe anaemia in a Kenyan hospital: an open-label single-arm trial
- 21 December 2011
- Published by Wiley in Transfusion
- Vol. 52 (7) , 1542-1551
The microbiologic safety of umbilical cord blood transfusion for children with severe anemia in Mombasa, Kenya
BACKGROUND: Severe anemia requiring blood transfusion is common in hospitalized young children in sub‐Saharan Africa but blood is often in short supply. Umbilical cord blood may be a useful source of blood if microbiologic safety concerns can be addressed. STUDY DESIGN AND METHODS: Cord blood, donated on the labor ward at the provincial hospital in Mombasa, was cultured soon after collection (screening culture) and after a period of storage (poststorage culture). Conventional blood transfused to children at the hospital was cultured only at the time of issue (poststorage culture). Maternal sera (cord blood) and conventional blood donations were also screened for transfusion‐transmitted infection. RESULTS: At poststorage culture, the overall contamination rate of cord blood was one‐third that of conventional blood (13/449 vs. 38/434; odds ratio [OR], 0.31; 95% confidence interval [CI], 0.15‐0.61) and for bacteria of high pathogenic potential it was half that of conventional blood (4/449 vs. 7/434; OR, 0.55; 95% CI, 0.12‐2.18). Screening cultures were positive in 50% (2/4) of cord blood packs where an organism of high pathogenic potential was isolated at poststorage culture. Cord blood donors had a lower seroreactivity than conventional donors for human immunodeficiency virus (OR, 0.63; 95% CI, 0.29‐1.18), hepatitis B virus (OR, 0.32; 95% CI, 0.16‐0.59), and hepatitis C virus (OR, 0.20; 95% CI, 0.24‐0.76). For syphilis, initial seroreactivity in cord blood donors was 3.8% compared to 1.8% in conventional blood donors (OR, 2.10; 95% CI, 1.15‐3.60) but was 0.5% after retesting. CONCLUSION: With respect to bacterial contamination and seroreactivity for transfusion‐transmitted infection, the safety of cord blood in Mombasa compares favorably with conventional blood. Clinical trials of cord blood transfusion are justified.
- 21 December 2011
- Published by Wiley in Transfusion
- Vol. 52 (7) , 1542-1551
The microbiologic safety of umbilical cord blood transfusion for children with severe anemia in Mombasa, Kenya
BACKGROUND: Severe anemia requiring blood transfusion is common in hospitalized young children in sub‐Saharan Africa but blood is often in short supply. Umbilical cord blood may be a useful source of blood if microbiologic safety concerns can be addressed. STUDY DESIGN AND METHODS: Cord blood, donated on the labor ward at the provincial hospital in Mombasa, was cultured soon after collection (screening culture) and after a period of storage (poststorage culture). Conventional blood transfused to children at the hospital was cultured only at the time of issue (poststorage culture). Maternal sera (cord blood) and conventional blood donations were also screened for transfusion‐transmitted infection. RESULTS: At poststorage culture, the overall contamination rate of cord blood was one‐third that of conventional blood (13/449 vs. 38/434; odds ratio [OR], 0.31; 95% confidence interval [CI], 0.15‐0.61) and for bacteria of high pathogenic potential it was half that of conventional blood (4/449 vs. 7/434; OR, 0.55; 95% CI, 0.12‐2.18). Screening cultures were positive in 50% (2/4) of cord blood packs where an organism of high pathogenic potential was isolated at poststorage culture. Cord blood donors had a lower seroreactivity than conventional donors for human immunodeficiency virus (OR, 0.63; 95% CI, 0.29‐1.18), hepatitis B virus (OR, 0.32; 95% CI, 0.16‐0.59), and hepatitis C virus (OR, 0.20; 95% CI, 0.24‐0.76). For syphilis, initial seroreactivity in cord blood donors was 3.8% compared to 1.8% in conventional blood donors (OR, 2.10; 95% CI, 1.15‐3.60) but was 0.5% after retesting. CONCLUSION: With respect to bacterial contamination and seroreactivity for transfusion‐transmitted infection, the safety of cord blood in Mombasa compares favorably with conventional blood. Clinical trials of cord blood transfusion are justified.
- Open Access
- 1 March 2010
- Published by Wiley in Transfusion
- Vol. 50 (3) , 611-616
BLOOD COMPONENTS: The quality of stored umbilical cord and adult‐donated whole blood in Mombasa, Kenya
BACKGROUND: In sub‐Saharan Africa umbilical cord blood may be a useful source of blood for transfusion. Before clinical trials, evidence is needed that cord blood donations, which vary greatly in volume, can be collected and stored into a fixed volume of anticoagulant‐preservative solution obviating the need for prestorage processing.STUDY DESIGN AND METHODS: Twenty‐four umbilical cord whole blood (UC‐WB) donations were collected into 21 mL of CPDA‐1 and refrigerated for 35 days. The Kenya Blood Transfusion Service provided 12 adult‐donated whole blood (AD‐WB) controls. Supernatant hemoglobin (Hb) and potassium were assayed at 7‐day intervals.RESULTS: UC‐WB red blood cell hemolysis and potassium loss increased throughout storage but did not differ significantly with cord blood volume. Hemolysis rates did not differ significantly between UC‐WB and AD‐WB but UC‐WB potassium loss was slightly but significantly greater than AD‐WB on Days 2, 7, and 14 (p < 0.05). In the AD‐WB controls, eight were low volume (CONCLUSION: Variable volumes of UC‐WB can be stored for 35 days without prestorage processing and further work into its suitability for transfusion to children is justified. The quality of conventional AD‐WB is a concern and needs further evaluation.
- 1 March 2010
- Published by Wiley in Transfusion
- Vol. 50 (3) , 611-616
Open AccessBLOOD COMPONENTS: The quality of stored umbilical cord and adult‐donated whole blood in Mombasa, Kenya
BACKGROUND: In sub‐Saharan Africa umbilical cord blood may be a useful source of blood for transfusion. Before clinical trials, evidence is needed that cord blood donations, which vary greatly in volume, can be collected and stored into a fixed volume of anticoagulant‐preservative solution obviating the need for prestorage processing.STUDY DESIGN AND METHODS: Twenty‐four umbilical cord whole blood (UC‐WB) donations were collected into 21 mL of CPDA‐1 and refrigerated for 35 days. The Kenya Blood Transfusion Service provided 12 adult‐donated whole blood (AD‐WB) controls. Supernatant hemoglobin (Hb) and potassium were assayed at 7‐day intervals.RESULTS: UC‐WB red blood cell hemolysis and potassium loss increased throughout storage but did not differ significantly with cord blood volume. Hemolysis rates did not differ significantly between UC‐WB and AD‐WB but UC‐WB potassium loss was slightly but significantly greater than AD‐WB on Days 2, 7, and 14 (p < 0.05). In the AD‐WB controls, eight were low volume (CONCLUSION: Variable volumes of UC‐WB can be stored for 35 days without prestorage processing and further work into its suitability for transfusion to children is justified. The quality of conventional AD‐WB is a concern and needs further evaluation.
- Open Access
- 1 December 2009
- Published by Wiley in Transfusion
- Vol. 49 (12) , 2594-2598
TRANSFUSION COMPLICATIONS: Bacterial contamination of pediatric whole blood transfusions in a Kenyan hospital
BACKGROUND: Hospitalized children in sub‐Saharan Africa frequently receive whole blood transfusions for severe anemia. The risk from bacterial contamination of blood for transfusion in sub‐Saharan Africa is not known. This study assessed the frequency of bacterial contamination of pediatric whole blood transfusions at a referral hospital in Kenya.STUDY DESIGN AND METHODS: This was an observational study. Over the course of 1 year, bacteriologic cultures were performed on 434 of the 799 blood packs issued to children by the blood bank of Coast Provincial General Hospital, Mombasa. Clinical outcome was not assessed.RESULTS: Forty‐four bacterial contaminants were isolated from 38 blood packs—an overall contamination frequency of 8.8% (95% confidence interval, 6.1%‐11.4%). Sixty‐four percent of the bacteria isolated were Gram‐negative. Many of the isolates are usually found in the environment and the most likely source of contamination was considered to be the hospital blood bank.CONCLUSION: Bacterial contamination of whole blood may be a significant but unrecognized hazard of blood transfusion for children in sub‐Saharan Africa. Further work is needed to clarify the extent of the problem and its clinical consequences. Increased awareness and adherence to basic principles of asepsis in the hospital blood bank may be important immediate interventions.
- 1 December 2009
- Published by Wiley in Transfusion
- Vol. 49 (12) , 2594-2598
Open AccessTRANSFUSION COMPLICATIONS: Bacterial contamination of pediatric whole blood transfusions in a Kenyan hospital
BACKGROUND: Hospitalized children in sub‐Saharan Africa frequently receive whole blood transfusions for severe anemia. The risk from bacterial contamination of blood for transfusion in sub‐Saharan Africa is not known. This study assessed the frequency of bacterial contamination of pediatric whole blood transfusions at a referral hospital in Kenya.STUDY DESIGN AND METHODS: This was an observational study. Over the course of 1 year, bacteriologic cultures were performed on 434 of the 799 blood packs issued to children by the blood bank of Coast Provincial General Hospital, Mombasa. Clinical outcome was not assessed.RESULTS: Forty‐four bacterial contaminants were isolated from 38 blood packs—an overall contamination frequency of 8.8% (95% confidence interval, 6.1%‐11.4%). Sixty‐four percent of the bacteria isolated were Gram‐negative. Many of the isolates are usually found in the environment and the most likely source of contamination was considered to be the hospital blood bank.CONCLUSION: Bacterial contamination of whole blood may be a significant but unrecognized hazard of blood transfusion for children in sub‐Saharan Africa. Further work is needed to clarify the extent of the problem and its clinical consequences. Increased awareness and adherence to basic principles of asepsis in the hospital blood bank may be important immediate interventions.
- Open Access
- 7 December 2007
- Published by Wiley in Vox Sanguinis
- Vol. 94 (2) , 125-131
The acceptability to women in Mombasa, Kenya, of the donation and transfusion of umbilical cord blood for severe anaemia in young children
Background and Objectives Severe anaemia, for which a blood transfusion can be life saving, is common in hospitalized children in sub‐Saharan Africa but blood for transfusion is often in short supply. Umbilical cord blood is usually thrown away but could be a useful source of red cells for small volume transfusions in young children in this setting. The objective of this study was to evaluate the attitudes of women using the maternity services of the provincial hospital in Mombasa, Kenya, towards cord blood donation and transfusion, and essential aspects of this process including informed consent and the acceptability of screening for human immunodeficiency virus (HIV) infection.Materials and Methods A structured questionnaire was developed based on data provided by focus group discussions with women attending the hospital's maternity unit and administered to women who had recently delivered at the hospital.Results Of the 180 women who completed a questionnaire, the donation and transfusion of cord blood were acceptable to 81% and 78%, respectively. Ninety per cent of women who supported cord blood donation were willing to undergo further HIV testing at the time of delivery. Seventy‐seven per cent of women wanted informed consent to be sought for cord blood donation and 66% of these felt they could make this decision alone.Conclusion The donation of umbilical cord blood and its transfusion are acceptable to the majority of women delivering at Coast Provincial General Hospital, Mombasa. Findings from the study will benefit the planned cord blood donation programme at this facility.
- 7 December 2007
- Published by Wiley in Vox Sanguinis
- Vol. 94 (2) , 125-131
Open AccessThe acceptability to women in Mombasa, Kenya, of the donation and transfusion of umbilical cord blood for severe anaemia in young children
Background and Objectives Severe anaemia, for which a blood transfusion can be life saving, is common in hospitalized children in sub‐Saharan Africa but blood for transfusion is often in short supply. Umbilical cord blood is usually thrown away but could be a useful source of red cells for small volume transfusions in young children in this setting. The objective of this study was to evaluate the attitudes of women using the maternity services of the provincial hospital in Mombasa, Kenya, towards cord blood donation and transfusion, and essential aspects of this process including informed consent and the acceptability of screening for human immunodeficiency virus (HIV) infection.Materials and Methods A structured questionnaire was developed based on data provided by focus group discussions with women attending the hospital's maternity unit and administered to women who had recently delivered at the hospital.Results Of the 180 women who completed a questionnaire, the donation and transfusion of cord blood were acceptable to 81% and 78%, respectively. Ninety per cent of women who supported cord blood donation were willing to undergo further HIV testing at the time of delivery. Seventy‐seven per cent of women wanted informed consent to be sought for cord blood donation and 66% of these felt they could make this decision alone.Conclusion The donation of umbilical cord blood and its transfusion are acceptable to the majority of women delivering at Coast Provincial General Hospital, Mombasa. Findings from the study will benefit the planned cord blood donation programme at this facility.