Göran Lundborg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Göran Lundborg has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Anders Björkman
Department of Hand Surgery, Sahlgrenska University Hospital, Mölndal, Sweden
3 shared publications B. Rosén
Department of Hand Surgery, Malmö University Hospital, Lund University, Malmö, Sweden
3 shared publications- Birgitta Rosén
Department of Hand Surgery, Malmo University Hospital, Malmo, Sweden
3 shared publications Birgitta Rosén
Dept. of Hand Surg., Malmo Univ. Hosp., Malmo, Sweden
2 shared publications- Christian Balkenius
Lund University, Lund, Sweden
2 shared publications - Fredrik Sebelius
Lund University Cognitive Science, Lund, Sweden
2 shared publications
Latest Publications
- Open Access
- 1 January 2011
- Published by Springer Nature in Journal of Occupational Medicine and Toxicology
- Vol. 6 (1) , 13
Improving hand sensibility in vibration induced neuropathy: A case-series
We report a long-term series of nine workers suffering from vibration-induced neuropathy, after many years of exposure to hand-held vibrating tools at high or low frequency. They were treated with temporary selective cutaneous anaesthesia (EMLA® cream) of the forearm repeatedly for a period up to one year (in two cases four years). The aim was to improve their capacity to perceive touch and thereby improve hand function and diminish disability. The treatment principle is based on current concepts of brain plasticity, where a deafferentation of a skin area results in improved sensory function in adjacent skin areas. All participants had sensory hand problems in terms of numbness (median touch thresholds > 70 mg) and impaired hand function influencing ADL (mean DASH score 22).After an initial identical self-administered treatment period of 8 weeks (12-15 treatments with increasing intervals) they did one treatment every 2-3 month. After one year sensibility (touch thresholds and tactile discrimination) as well as hand function (mean DASH score 13) were improved in a majority of the cases. Seven of the participants choose to continue the treatment after the first year and two of them have continued at a regular basis for up to four years. A surprising, secondary finding was diminishing nocturnal numbness of the hand and arm in eight of the nine subjects from "frequently" to "hardly ever or never". Our observations open new perspectives for treatment of impaired sensibility and hand function in a group of patients with vibration induced hand problems where we have no treatment to offer today.
- 1 January 2011
- Published by Springer Nature in Journal of Occupational Medicine and Toxicology
- Vol. 6 (1) , 13
Open AccessImproving hand sensibility in vibration induced neuropathy: A case-series
We report a long-term series of nine workers suffering from vibration-induced neuropathy, after many years of exposure to hand-held vibrating tools at high or low frequency. They were treated with temporary selective cutaneous anaesthesia (EMLA® cream) of the forearm repeatedly for a period up to one year (in two cases four years). The aim was to improve their capacity to perceive touch and thereby improve hand function and diminish disability. The treatment principle is based on current concepts of brain plasticity, where a deafferentation of a skin area results in improved sensory function in adjacent skin areas. All participants had sensory hand problems in terms of numbness (median touch thresholds > 70 mg) and impaired hand function influencing ADL (mean DASH score 22).After an initial identical self-administered treatment period of 8 weeks (12-15 treatments with increasing intervals) they did one treatment every 2-3 month. After one year sensibility (touch thresholds and tactile discrimination) as well as hand function (mean DASH score 13) were improved in a majority of the cases. Seven of the participants choose to continue the treatment after the first year and two of them have continued at a regular basis for up to four years. A surprising, secondary finding was diminishing nocturnal numbness of the hand and arm in eight of the nine subjects from "frequently" to "hardly ever or never". Our observations open new perspectives for treatment of impaired sensibility and hand function in a group of patients with vibration induced hand problems where we have no treatment to offer today.
- Open Access
- 1 January 2010
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 9 (1) , 50
Design and technical construction of a tactile display for sensory feedback in a hand prosthesis system
The users of today's commercial prosthetic hands are not given any conscious sensory feedback. To overcome this deficiency in prosthetic hands we have recently proposed a sensory feedback system utilising a "tactile display" on the remaining amputation residual limb acting as man-machine interface. Our system uses the recorded pressure in a hand prosthesis and feeds back this pressure onto the forearm skin. Here we describe the design and technical solution of the sensory feedback system aimed at hand prostheses for trans-radial/humeral amputees. Critical parameters for the sensory feedback system were investigated. A sensory feedback system consisting of five actuators, control electronics and a test application running on a computer has been designed and built. Firstly, we investigate which force levels were applied to the forearm skin of the user while operating the sensory feedback system. Secondly, we study if the proposed system could be used together with a myoelectric control system. The displacement of the skin caused by the sensory feedback system would generate artefacts in the recorded myoelectric signals. Accordingly, EMG recordings were performed and an analysis of the these are included. The sensory feedback system was also preliminarily evaluated in a laboratory setting on two healthy non-amputated test subjects with a computer generating the stimuli, with regards to spatial resolution and force discrimination. We showed that the sensory feedback system generated approximately proportional force to the angle of control. The system can be used together with a myoelectric system as the artefacts, generated by the actuators, were easily removed using a simple filter. Furthermore, the application of the system on two test subjects showed that they were able to discriminate tactile sensation with regards to spatial resolution and level of force. The results of these initial experiments in non-amputees indicate that the proposed tactile display, in its simple form, can be used to relocate tactile input from an artificial hand to the forearm and that the system can coexist with a myoelectric control systems. The proposed system may be a valuable addition to users of myoelectric prosthesis providing conscious sensory feedback during manipulation of objects.
- 1 January 2010
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 9 (1) , 50
Open AccessDesign and technical construction of a tactile display for sensory feedback in a hand prosthesis system
The users of today's commercial prosthetic hands are not given any conscious sensory feedback. To overcome this deficiency in prosthetic hands we have recently proposed a sensory feedback system utilising a "tactile display" on the remaining amputation residual limb acting as man-machine interface. Our system uses the recorded pressure in a hand prosthesis and feeds back this pressure onto the forearm skin. Here we describe the design and technical solution of the sensory feedback system aimed at hand prostheses for trans-radial/humeral amputees. Critical parameters for the sensory feedback system were investigated. A sensory feedback system consisting of five actuators, control electronics and a test application running on a computer has been designed and built. Firstly, we investigate which force levels were applied to the forearm skin of the user while operating the sensory feedback system. Secondly, we study if the proposed system could be used together with a myoelectric control system. The displacement of the skin caused by the sensory feedback system would generate artefacts in the recorded myoelectric signals. Accordingly, EMG recordings were performed and an analysis of the these are included. The sensory feedback system was also preliminarily evaluated in a laboratory setting on two healthy non-amputated test subjects with a computer generating the stimuli, with regards to spatial resolution and force discrimination. We showed that the sensory feedback system generated approximately proportional force to the angle of control. The system can be used together with a myoelectric system as the artefacts, generated by the actuators, were easily removed using a simple filter. Furthermore, the application of the system on two test subjects showed that they were able to discriminate tactile sensation with regards to spatial resolution and level of force. The results of these initial experiments in non-amputees indicate that the proposed tactile display, in its simple form, can be used to relocate tactile input from an artificial hand to the forearm and that the system can coexist with a myoelectric control systems. The proposed system may be a valuable addition to users of myoelectric prosthesis providing conscious sensory feedback during manipulation of objects.
- 15 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 56 (11) , 2739-2743
A Novel Concept for a Prosthetic Hand With a Bidirectional Interface: A Feasibility Study
A conceptually novel prosthesis consisting of a mechatronic hand, an electromyographic classifier, and a tactile display has been developed and evaluated by addressing problems related to controllability in prosthetics: intention extraction, perception, and feeling of ownership. Experiments have been performed, and encouraging results for a young transradial amputee are reported.
- 15 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 56 (11) , 2739-2743
A Novel Concept for a Prosthetic Hand With a Bidirectional Interface: A Feasibility Study
A conceptually novel prosthesis consisting of a mechatronic hand, an electromyographic classifier, and a tactile display has been developed and evaluated by addressing problems related to controllability in prosthetics: intention extraction, perception, and feeling of ownership. Experiments have been performed, and encouraging results for a young transradial amputee are reported.
- Open Access
- 5 August 2009
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 10 (1) , 99
Principles of brain plasticity in improving sensorimotor function of the knee and leg in healthy subjects: A double-blind randomized exploratory trial
Principles of brain plasticity is used in the treatment of patients with functional limitations to improve sensorimotor function. Training is included in the treatment of knee injury to improve both patient-reported function and sensorimotor function. However, impairment in sensorimotor function often persists despite training. Therefore, it was suggested that training programs need to be more effective to improve sensorimotor function after knee injury. The aim of the current study was to investigate if principles of brain plasticity that have been successfully used on the hand and foot to improve sensorimotor function can be applied on the knee. We hypothesized that temporary anesthesia of the skin area above and below the knee would improve sensorimotor function of the ipsilateral knee and leg.
- 5 August 2009
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 10 (1) , 99
Open AccessPrinciples of brain plasticity in improving sensorimotor function of the knee and leg in healthy subjects: A double-blind randomized exploratory trial
Principles of brain plasticity is used in the treatment of patients with functional limitations to improve sensorimotor function. Training is included in the treatment of knee injury to improve both patient-reported function and sensorimotor function. However, impairment in sensorimotor function often persists despite training. Therefore, it was suggested that training programs need to be more effective to improve sensorimotor function after knee injury. The aim of the current study was to investigate if principles of brain plasticity that have been successfully used on the hand and foot to improve sensorimotor function can be applied on the knee. We hypothesized that temporary anesthesia of the skin area above and below the knee would improve sensorimotor function of the ipsilateral knee and leg.
- 23 January 2007
- Published by Wiley in Acta Physiologica
- Vol. 189 (2) , 207-217
Hand function after nerve repair
Treatment of injuries to major nerve trunks in the hand and upper extremity remains a major and challenging reconstructive problem. Such injuries may cause long‐lasting disabilities in terms of lost fine sensory and motor functions. Nowadays there is no surgical repair technique that can ensure recovery of tactile discrimination in the hand of an adult patient following nerve repair while very young individuals usually regain a complete recovery of functional sensibility. Post‐traumatic nerve regeneration is a complex biological process where the outcome depends on multiple biological and environmental factors such as survival of nerve cells, axonal regeneration rate, extent of axonal misdirection, type of injury, type of nerve, level of the lesion, age of the patient and compliance to training. A major problem is the cortical functional reorganization of hand representation which occurs as a result of axonal misdirection. Although protective sensibility usually occurs following nerve repair, tactile discriminative functions seldom recover – a direct result of cortical remapping. Sensory re‐education programmes are routinely applied to facilitate understanding of the new sensory patterns provided by the hand. New trends in hand rehabilitation focus on modulation of central nervous processes rather than peripheral factors. Principles are being evolved to maintain the cortical hand representation by using the brain capacity for visuo‐tactile and audio‐tactile interaction for the initial phase following nerve injury and repair (phase 1). After the start of the re‐innervation of the hand (phase 2), selective de‐afferentation, such as cutaneous anaesthesia of the forearm of the injured hand, allows expansion of the nerve‐injured cortical hand representation, thereby enhancing the effects of sensory relearning. Recent data support the view that training protocols specifically addressing the relearning process substantially increase the possibilities for improved functional outcome after nerve repair.
- 23 January 2007
- Published by Wiley in Acta Physiologica
- Vol. 189 (2) , 207-217
Hand function after nerve repair
Treatment of injuries to major nerve trunks in the hand and upper extremity remains a major and challenging reconstructive problem. Such injuries may cause long‐lasting disabilities in terms of lost fine sensory and motor functions. Nowadays there is no surgical repair technique that can ensure recovery of tactile discrimination in the hand of an adult patient following nerve repair while very young individuals usually regain a complete recovery of functional sensibility. Post‐traumatic nerve regeneration is a complex biological process where the outcome depends on multiple biological and environmental factors such as survival of nerve cells, axonal regeneration rate, extent of axonal misdirection, type of injury, type of nerve, level of the lesion, age of the patient and compliance to training. A major problem is the cortical functional reorganization of hand representation which occurs as a result of axonal misdirection. Although protective sensibility usually occurs following nerve repair, tactile discriminative functions seldom recover – a direct result of cortical remapping. Sensory re‐education programmes are routinely applied to facilitate understanding of the new sensory patterns provided by the hand. New trends in hand rehabilitation focus on modulation of central nervous processes rather than peripheral factors. Principles are being evolved to maintain the cortical hand representation by using the brain capacity for visuo‐tactile and audio‐tactile interaction for the initial phase following nerve injury and repair (phase 1). After the start of the re‐innervation of the hand (phase 2), selective de‐afferentation, such as cutaneous anaesthesia of the forearm of the injured hand, allows expansion of the nerve‐injured cortical hand representation, thereby enhancing the effects of sensory relearning. Recent data support the view that training protocols specifically addressing the relearning process substantially increase the possibilities for improved functional outcome after nerve repair.
- 1 January 2007
- Published by Springer Nature
- Vol. 100, 121-126
Enhanced sensory relearning after nerve repair by using repeated forearm anaesthesia: aspects on time dynamics of treatment
We describe a new principle for enhancing the effects of sensory re-education following nerve injury and repair. The outcome from nerve repair in adult patients is generally poor. One reason is the functional cortical reorganisation which always occurs because of axonal misdirection at the repair site. In healthy individuals selective anaesthesia of the forearm results in improved hand sensation. Here we hypothesised that this principle would be valid also after nerve injury and repair.
- 1 January 2007
- Published by Springer Nature
- Vol. 100, 121-126
Enhanced sensory relearning after nerve repair by using repeated forearm anaesthesia: aspects on time dynamics of treatment
We describe a new principle for enhancing the effects of sensory re-education following nerve injury and repair. The outcome from nerve repair in adult patients is generally poor. One reason is the functional cortical reorganisation which always occurs because of axonal misdirection at the repair site. In healthy individuals selective anaesthesia of the forearm results in improved hand sensation. Here we hypothesised that this principle would be valid also after nerve injury and repair.
- 1 January 2007
- Published by Taylor & Francis in Scandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery
- Vol. 41 (3) , 130-137
Osseointegrated wrist-joint prostheses: A 15-year follow-up with focus on bony fixation
Five patients with rheumatoid arthritis or osteoarthrosis of the wrist joint were followed up for 15 (14-17) years after wrist-joint arthroplasty with semiconstrained artificial joint mechanisms that had been anchored to bone using the osseointegration principle. They were fixed by one titanium screw introduced into the radius, and two or more titanium screws introduced distally into the metacarpal bones. In four cases a screw was also introduced into the ulna thereby constituting one component in a distal radio-ulnar (DRU) joint mechanism. The titanium screw introduced into the radius and the distal metacarpal screws osseointegrated in all cases. In three cases the mechanism of the wrist joint or parts of it were replaced with new components that could be attached to the screws that were already osseointegrated. We conclude that wrist joint prostheses can be anchored to the surrounding bone using osseointegration and that they remain fixed for at least 15 years. The principle allows replacement of the joint mechanism, if needed, with maintenance of the osseointegrated anchoring elements.
- 1 January 2007
- Published by Taylor & Francis in Scandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery
- Vol. 41 (3) , 130-137
Osseointegrated wrist-joint prostheses: A 15-year follow-up with focus on bony fixation
Five patients with rheumatoid arthritis or osteoarthrosis of the wrist joint were followed up for 15 (14-17) years after wrist-joint arthroplasty with semiconstrained artificial joint mechanisms that had been anchored to bone using the osseointegration principle. They were fixed by one titanium screw introduced into the radius, and two or more titanium screws introduced distally into the metacarpal bones. In four cases a screw was also introduced into the ulna thereby constituting one component in a distal radio-ulnar (DRU) joint mechanism. The titanium screw introduced into the radius and the distal metacarpal screws osseointegrated in all cases. In three cases the mechanism of the wrist joint or parts of it were replaced with new components that could be attached to the screws that were already osseointegrated. We conclude that wrist joint prostheses can be anchored to the surrounding bone using osseointegration and that they remain fixed for at least 15 years. The principle allows replacement of the joint mechanism, if needed, with maintenance of the osseointegrated anchoring elements.
- 30 June 2006
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 31, 49
10.6Cutaneous anaesthesia of the forearm enhances sensory recovery in the hand after median nerve repair
- 30 June 2006
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 31, 49
10.6Cutaneous anaesthesia of the forearm enhances sensory recovery in the hand after median nerve repair
- 1 January 2006
- Published by Taylor & Francis in Scandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery
- Vol. 40 (4) , 234-239
Functional magnetic resonance imaging shows cortical activation on sensory stimulation of an osseointegrated prosthetic thumb
Functional magnetic resonance imaging (fMRI) was used to study the cortical integration of an osseointegrated prosthetic thumb that had been attached to the amputee's hand 13 years ago. We found that tactile stimuli applied to the prosthesis activated the primary somatosensory cortex on both sides.
- 1 January 2006
- Published by Taylor & Francis in Scandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery
- Vol. 40 (4) , 234-239
Functional magnetic resonance imaging shows cortical activation on sensory stimulation of an osseointegrated prosthetic thumb
Functional magnetic resonance imaging (fMRI) was used to study the cortical integration of an osseointegrated prosthetic thumb that had been attached to the amputee's hand 13 years ago. We found that tactile stimuli applied to the prosthesis activated the primary somatosensory cortex on both sides.