Ikaro Silva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ikaro Silva has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Joon Lee
Data Intelligence for Health Lab, Cumming School of Medicine, University of Calgary, Calgary, Canada
4 shared publications - Gari D. Clifford
Emory University
3 shared publications - George B. Moody
Massachusetts Institute of Technology
3 shared publications - Roger G. Mark
Massachusetts Institute of Technology
3 shared publications George B Moody
Institute for Medical Engineering and Science, Massachusetts Institute of Technology
2 shared publicationsJoachim Behar
University of Oxford
2 shared publications
Latest Publications
- 28 July 2015
- Published by IOP Publishing in Physiological Measurement
- Vol. 36 (8) , 1629-1644
Robust detection of heart beats in multimodal data
This editorial reviews the background issues, the design, the key achievements, and the follow-up research generated as a result of the PhysioNet/Computing in Cardiology (CinC) Challenge 2014, published in the concurrent focus issue of Physiological Measurement . Our major focus was to accelerate the development and facilitate the comparison of robust methods for locating heart beats in long-term multi-channel recordings. A public (training) database consisting of 151 032 annotated beats was compiled from records that contained ECGs as well as pulsatile signals that directly reflect cardiac activity, and other signals that may have few or no observable markers of heart beats. A separate hidden test data set (consisting of 152 478 beats) is permanently stored at PhysioNet, and a public framework has been developed to provide researchers with the ability to continue to automatically score and compare the performance of their algorithms. A scoring criteria based on the averaging of gross sensitivity, gross positive predictivity, average sensitivity, and average positive predictivity is proposed. The top three scores (as of March 2015) on the hidden test data set were 93.64%, 91.50%, and 90.70%.
- 28 July 2015
- Published by IOP Publishing in Physiological Measurement
- Vol. 36 (8) , 1629-1644
Robust detection of heart beats in multimodal data
This editorial reviews the background issues, the design, the key achievements, and the follow-up research generated as a result of the PhysioNet/Computing in Cardiology (CinC) Challenge 2014, published in the concurrent focus issue of Physiological Measurement . Our major focus was to accelerate the development and facilitate the comparison of robust methods for locating heart beats in long-term multi-channel recordings. A public (training) database consisting of 151 032 annotated beats was compiled from records that contained ECGs as well as pulsatile signals that directly reflect cardiac activity, and other signals that may have few or no observable markers of heart beats. A separate hidden test data set (consisting of 152 478 beats) is permanently stored at PhysioNet, and a public framework has been developed to provide researchers with the ability to continue to automatically score and compare the performance of their algorithms. A scoring criteria based on the averaging of gross sensitivity, gross positive predictivity, average sensitivity, and average positive predictivity is proposed. The top three scores (as of March 2015) on the hidden test data set were 93.64%, 91.50%, and 90.70%.
- Open Access
- 20 June 2015
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 14 (1) , 1-19
Quality estimation of the electrocardiogram using cross-correlation among leads
Fast and accurate quality estimation of the electrocardiogram (ECG) signal is a relevant research topic that has attracted considerable interest in the scientific community, particularly due to its impact on tele-medicine monitoring systems, where the ECG is collected by untrained technicians. In recent years, a number of studies have addressed this topic, showing poor performance in discriminating between clinically acceptable and unacceptable ECG records. This paper presents a novel, simple and accurate algorithm to estimate the quality of the 12-lead ECG by exploiting the structure of the cross-covariance matrix among different leads. Ideally, ECG signals from different leads should be highly correlated since they capture the same electrical activation process of the heart. However, in the presence of noise or artifacts the covariance among these signals will be affected. Eigenvalues of the ECG signals covariance matrix are fed into three different supervised binary classifiers. The performance of these classifiers were evaluated using PhysioNet/CinC Challenge 2011 data. Our best quality classifier achieved an accuracy of 0.898 in the test set, while having a complexity well below the results of contestants who participated in the Challenge, thus making it suitable for implementation in current cellular devices.
- 20 June 2015
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 14 (1) , 1-19
Open AccessQuality estimation of the electrocardiogram using cross-correlation among leads
Fast and accurate quality estimation of the electrocardiogram (ECG) signal is a relevant research topic that has attracted considerable interest in the scientific community, particularly due to its impact on tele-medicine monitoring systems, where the ECG is collected by untrained technicians. In recent years, a number of studies have addressed this topic, showing poor performance in discriminating between clinically acceptable and unacceptable ECG records. This paper presents a novel, simple and accurate algorithm to estimate the quality of the 12-lead ECG by exploiting the structure of the cross-covariance matrix among different leads. Ideally, ECG signals from different leads should be highly correlated since they capture the same electrical activation process of the heart. However, in the presence of noise or artifacts the covariance among these signals will be affected. Eigenvalues of the ECG signals covariance matrix are fed into three different supervised binary classifiers. The performance of these classifiers were evaluated using PhysioNet/CinC Challenge 2011 data. Our best quality classifier achieved an accuracy of 0.898 in the test set, while having a complexity well below the results of contestants who participated in the Challenge, thus making it suitable for implementation in current cellular devices.
- Open Access
- 24 September 2014
- Published by Ubiquity Press, Ltd. in Journal of Open Research Software
- Vol. 2 (1)
An Open-source Toolbox for Analysing and Processing PhysioNet Databases in MATLAB and Octave
The WaveForm DataBase (WFDB) Toolbox for MATLAB/Octave enables integrated access to PhysioNet’s software and databases. Using the WFDB Toolbox for MATLAB/Octave, users have access to over 50 physiological databases in PhysioNet. The toolbox provides access over 4 TB of biomedical signals including ECG, EEG, EMG, and PLETH. Additionally, most signals are accompanied by metadata such as medical annotations of clinical events: arrhythmias, sleep stages, seizures, hypotensive episodes, etc. Users of this toolbox should easily be able to reproduce, validate, and compare results published based on PhysioNet’s software and databases.
- 24 September 2014
- Published by Ubiquity Press, Ltd. in Journal of Open Research Software
- Vol. 2 (1)
Open AccessAn Open-source Toolbox for Analysing and Processing PhysioNet Databases in MATLAB and Octave
The WaveForm DataBase (WFDB) Toolbox for MATLAB/Octave enables integrated access to PhysioNet’s software and databases. Using the WFDB Toolbox for MATLAB/Octave, users have access to over 50 physiological databases in PhysioNet. The toolbox provides access over 4 TB of biomedical signals including ECG, EEG, EMG, and PLETH. Additionally, most signals are accompanied by metadata such as medical annotations of clinical events: arrhythmias, sleep stages, seizures, hypotensive episodes, etc. Users of this toolbox should easily be able to reproduce, validate, and compare results published based on PhysioNet’s software and databases.
- 29 July 2014
- Published by IOP Publishing in Physiological Measurement
- Vol. 35 (8) , 1521-1536
Non-invasive fetal ECG analysis
Despite the important advances achieved in the field of adult electrocardiography signal processing, the analysis of the non-invasive fetal electrocardiogram (NI-FECG) remains a challenge. Currently no gold standard database exists which provides labelled FECG QRS complexes (and other morphological parameters), and publications rely either on proprietary databases or a very limited set of data recorded from few (or more often, just one) individuals.The PhysioNet/Computing in Cardiology Challenge 2013 enables to tackle some of these limitations by releasing a set of NI-FECG data publicly to the scientific community in order to evaluate signal processing techniques for NI-FECG extraction. The Challenge aim was to encourage development of accurate algorithms for locating QRS complexes and estimating the QT interval in non-invasive FECG signals. Using carefully reviewed reference QRS annotations and QT intervals as a gold standard, based on simultaneous direct FECG when possible, the Challenge was designed to measure and compare the performance of participants' algorithms objectively. Multiple challenge events were designed to test basic FHR estimation accuracy, as well as accuracy in measurement of inter-beat (RR) and QT intervals needed as a basis for derivation of other FECG features.This editorial reviews the background issues, the design of the Challenge, the key achievements, and the follow-up research generated as a result of the Challenge, published in the concurrent special issue of Physiological Measurement.
- 29 July 2014
- Published by IOP Publishing in Physiological Measurement
- Vol. 35 (8) , 1521-1536
Non-invasive fetal ECG analysis
Despite the important advances achieved in the field of adult electrocardiography signal processing, the analysis of the non-invasive fetal electrocardiogram (NI-FECG) remains a challenge. Currently no gold standard database exists which provides labelled FECG QRS complexes (and other morphological parameters), and publications rely either on proprietary databases or a very limited set of data recorded from few (or more often, just one) individuals.The PhysioNet/Computing in Cardiology Challenge 2013 enables to tackle some of these limitations by releasing a set of NI-FECG data publicly to the scientific community in order to evaluate signal processing techniques for NI-FECG extraction. The Challenge aim was to encourage development of accurate algorithms for locating QRS complexes and estimating the QT interval in non-invasive FECG signals. Using carefully reviewed reference QRS annotations and QT intervals as a gold standard, based on simultaneous direct FECG when possible, the Challenge was designed to measure and compare the performance of participants' algorithms objectively. Multiple challenge events were designed to test basic FHR estimation accuracy, as well as accuracy in measurement of inter-beat (RR) and QT intervals needed as a basis for derivation of other FECG features.This editorial reviews the background issues, the design of the Challenge, the key achievements, and the follow-up research generated as a result of the Challenge, published in the concurrent special issue of Physiological Measurement.
- 1 March 2013
- Vol. 40, 149-152
Noninvasive Fetal ECG: the PhysioNet/Computing in Cardiology Challenge 2013
The PhysioNet/CinC 2013 Challenge aimed to stimulate rapid development and improvement of software for estimating fetal heart rate (FHR), fetal interbeat intervals (FRR), and fetal QT intervals (FQT), from multichannel recordings made using electrodes placed on the mother’s abdomen. For the challenge, five data collections from a variety of sources were used to compile a large standardized database, which was divided into training, open test, and hidden test subsets. Gold-standard fetal QRS and QT interval annotations were developed using a novel crowd-sourcing framework.
- 1 March 2013
- Vol. 40, 149-152
Noninvasive Fetal ECG: the PhysioNet/Computing in Cardiology Challenge 2013
The PhysioNet/CinC 2013 Challenge aimed to stimulate rapid development and improvement of software for estimating fetal heart rate (FHR), fetal interbeat intervals (FRR), and fetal QT intervals (FQT), from multichannel recordings made using electrodes placed on the mother’s abdomen. For the challenge, five data collections from a variety of sources were used to compile a large standardized database, which was divided into training, open test, and hidden test subsets. Gold-standard fetal QRS and QT interval annotations were developed using a novel crowd-sourcing framework.
- Open Access
- 10 January 2013
- Published by Springer Nature in BMC Medical Informatics and Decision Making
- Vol. 13 (1) , 9
Accessing the public MIMIC-II intensive care relational database for clinical research
Background: The Multiparameter Intelligent Monitoring in Intensive Care II (MIMIC-II) database is a free, public resource for intensive care research. The database was officially released in 2006, and has attracted a growing number of researchers in academia and industry. We present the two major software tools that facilitate accessing the relational database: the web-based QueryBuilder and a downloadable virtual machine (VM) image. Results: QueryBuilder and the MIMIC-II VM have been developed successfully and are freely available to MIMIC-II users. Simple example SQL queries and the resulting data are presented. Clinical studies pertaining to acute kidney injury and prediction of fluid requirements in the intensive care unit are shown as typical examples of research performed with MIMIC-II. In addition, MIMIC-II has also provided data for annual PhysioNet/Computing in Cardiology Challenges, including the 2012 Challenge “Predicting mortality of ICU Patients”. Conclusions: QueryBuilder is a web-based tool that provides easy access to MIMIC-II. For more computationally intensive queries, one can locally install a complete copy of MIMIC-II in a VM. Both publicly available tools provide the MIMIC-II research community with convenient querying interfaces and complement the value of the MIMIC-II relational database.
- 10 January 2013
- Published by Springer Nature in BMC Medical Informatics and Decision Making
- Vol. 13 (1) , 9
Open AccessAccessing the public MIMIC-II intensive care relational database for clinical research
Background: The Multiparameter Intelligent Monitoring in Intensive Care II (MIMIC-II) database is a free, public resource for intensive care research. The database was officially released in 2006, and has attracted a growing number of researchers in academia and industry. We present the two major software tools that facilitate accessing the relational database: the web-based QueryBuilder and a downloadable virtual machine (VM) image. Results: QueryBuilder and the MIMIC-II VM have been developed successfully and are freely available to MIMIC-II users. Simple example SQL queries and the resulting data are presented. Clinical studies pertaining to acute kidney injury and prediction of fluid requirements in the intensive care unit are shown as typical examples of research performed with MIMIC-II. In addition, MIMIC-II has also provided data for annual PhysioNet/Computing in Cardiology Challenges, including the 2012 Challenge “Predicting mortality of ICU Patients”. Conclusions: QueryBuilder is a web-based tool that provides easy access to MIMIC-II. For more computationally intensive queries, one can locally install a complete copy of MIMIC-II in a VM. Both publicly available tools provide the MIMIC-II research community with convenient querying interfaces and complement the value of the MIMIC-II relational database.
- 1 September 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 59 (9) , 2476-2485
Signal Quality Estimation With Multichannel Adaptive Filtering in Intensive Care Settings
A signal quality estimate of a physiological waveform can be an important initial step for automated processing of real-world data. This paper presents a new generic point-by-point signal quality index (SQI) based on adaptive multichannel prediction that does not rely on ad hoc morphological feature extraction from the target waveform. An application of this new SQI to photoplethysmograms (PPG), arterial blood pressure (ABP) measurements, and ECG showed that the SQI is monotonically related to signal-to-noise ratio (simulated by adding white Gaussian noise) and to subjective human quality assessment of 1361 multichannel waveform epochs. A receiver-operating-characteristic (ROC) curve analysis, with the human “bad” quality label as positive and the “good” quality label as negative, yielded areas under the ROC curve of 0.86 (PPG), 0.82 (ABP), and 0.68 (ECG).
- 1 September 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 59 (9) , 2476-2485
Signal Quality Estimation With Multichannel Adaptive Filtering in Intensive Care Settings
A signal quality estimate of a physiological waveform can be an important initial step for automated processing of real-world data. This paper presents a new generic point-by-point signal quality index (SQI) based on adaptive multichannel prediction that does not rely on ad hoc morphological feature extraction from the target waveform. An application of this new SQI to photoplethysmograms (PPG), arterial blood pressure (ABP) measurements, and ECG showed that the SQI is monotonically related to signal-to-noise ratio (simulated by adding white Gaussian noise) and to subjective human quality assessment of 1361 multichannel waveform epochs. A receiver-operating-characteristic (ROC) curve analysis, with the human “bad” quality label as positive and the “good” quality label as negative, yielded areas under the ROC curve of 0.86 (PPG), 0.82 (ABP), and 0.68 (ECG).
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2012 (1094687X) , 6078-6081
S2DIA: A Diagnostic System for Diabetes mellitus using SANA platform
Currently, Diabetes is a very common disease around the world, and with an increase in sedentary lifestyles, obesity and an aging population the number of people with Diabetes worldwide will increase by more than 50%. In this context, the MIT (Massachusetts Institute of Technology) developed the SANA platform, which brings the benefits of information technology to the field of healthcare. It offers healthcare delivery in remote areas, improves patient access to medical specialists for faster, higher quality, and more cost effective diagnosis and intervention. For these reasons, we developed a system for diagnosis of Diabetes using the SANA platform, called S2DIA. It is the first step towards knowing the risks for type 2 Diabetes, and it will be evaluated, especially, in remote/poor areas of Brazil.
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2012 (1094687X) , 6078-6081
S2DIA: A Diagnostic System for Diabetes mellitus using SANA platform
Currently, Diabetes is a very common disease around the world, and with an increase in sedentary lifestyles, obesity and an aging population the number of people with Diabetes worldwide will increase by more than 50%. In this context, the MIT (Massachusetts Institute of Technology) developed the SANA platform, which brings the benefits of information technology to the field of healthcare. It offers healthcare delivery in remote areas, improves patient access to medical specialists for faster, higher quality, and more cost effective diagnosis and intervention. For these reasons, we developed a system for diagnosis of Diabetes using the SANA platform, called S2DIA. It is the first step towards knowing the risks for type 2 Diabetes, and it will be evaluated, especially, in remote/poor areas of Brazil.
- 1 January 2012
- Vol. 39, 245-248
Predicting In-Hospital Mortality of ICU Patients: The PhysioNet/Computing in Cardiology Challenge 2012
Acuity scores, such as APACHE, SAPS, MPM, and SOFA, are widely used to account for population differences in studies aiming to compare how medications, care guidelines, surgery, and other interventions impact mortality in Intensive Care Unit (ICU) patients. By contrast, the focus of the PhysioNet/CinC Challenge 2012 is to develop methods for patient-specific prediction of in-hospital mortality. The data used for the challenge consisted of 5 general descriptors and 36 time series (measurements of vital signs and laboratory results) from the first 48 hours of the first available ICU stay of 12,000 adult patients from the MIMIC II database. The challenge was organized as two events: event 1 measured performance of a binary classifier, and event 2 measured performance of a risk estimator. The score of event 1 was the lower of sensitivity and positive predictive value. The score for event 2 was a range-normalized Hosmer-Lemeshow statistic. A baseline algorithm (using SAPS-1) obtained event 1 and 2 scores of 0.3125 and 68.58 respectively. Most participants submitted entries that outperformed the baseline algorithm. The top final scores for events 1 and 2 were 0.5353 and 17.88 respectively.
- 1 January 2012
- Vol. 39, 245-248
Predicting In-Hospital Mortality of ICU Patients: The PhysioNet/Computing in Cardiology Challenge 2012
Acuity scores, such as APACHE, SAPS, MPM, and SOFA, are widely used to account for population differences in studies aiming to compare how medications, care guidelines, surgery, and other interventions impact mortality in Intensive Care Unit (ICU) patients. By contrast, the focus of the PhysioNet/CinC Challenge 2012 is to develop methods for patient-specific prediction of in-hospital mortality. The data used for the challenge consisted of 5 general descriptors and 36 time series (measurements of vital signs and laboratory results) from the first 48 hours of the first available ICU stay of 12,000 adult patients from the MIMIC II database. The challenge was organized as two events: event 1 measured performance of a binary classifier, and event 2 measured performance of a risk estimator. The score of event 1 was the lower of sensitivity and positive predictive value. The score for event 2 was a range-normalized Hosmer-Lemeshow statistic. A baseline algorithm (using SAPS-1) obtained event 1 and 2 scores of 0.3125 and 68.58 respectively. Most participants submitted entries that outperformed the baseline algorithm. The top final scores for events 1 and 2 were 0.5353 and 17.88 respectively.
- Open Access
- 1 January 2012
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 11 (1) , 19
Transfer Entropy Estimation and Directional Coupling Change Detection in Biomedical Time Series
The detection of change in magnitude of directional coupling between two non-linear time series is a common subject of interest in the biomedical domain, including studies involving the respiratory chemoreflex system. Although transfer entropy is a useful tool in this avenue, no study to date has investigated how different transfer entropy estimation methods perform in typical biomedical applications featuring small sample size and presence of outliers. With respect to detection of increased coupling strength, we compared three transfer entropy estimation techniques using both simulated time series and respiratory recordings from lambs. The following estimation methods were analyzed: fixed-binning with ranking, kernel density estimation (KDE), and the Darbellay-Vajda (D-V) adaptive partitioning algorithm extended to three dimensions. In the simulated experiment, sample size was varied from 50 to 200, while coupling strength was increased. In order to introduce outliers, the heavy-tailed Laplace distribution was utilized. In the lamb experiment, the objective was to detect increased respiratory-related chemosensitivity to O 2 and CO 2 induced by a drug, domperidone. Specifically, the separate influence of end-tidal PO 2 and PCO 2 on minute ventilation before and after administration of domperidone was analyzed. In the simulation, KDE detected increased coupling strength at the lowest SNR among the three methods. In the lamb experiment, D-V partitioning resulted in the statistically strongest increase in transfer entropy post-domperidone for . In addition, D-V partitioning was the only method that could detect an increase in transfer entropy for , in agreement with experimental findings. Transfer entropy is capable of detecting directional coupling changes in non-linear biomedical time series analysis featuring a small number of observations and presence of outliers. The results of this study suggest that fixed-binning, even with ranking, is too primitive, and although there is no clear winner between KDE and D-V partitioning, the reader should note that KDE requires more computational time and extensive parameter selection than D-V partitioning. We hope this study provides a guideline for selection of an appropriate transfer entropy estimation method.- 1 January 2012
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 11 (1) , 19
Open AccessTransfer Entropy Estimation and Directional Coupling Change Detection in Biomedical Time Series
The detection of change in magnitude of directional coupling between two non-linear time series is a common subject of interest in the biomedical domain, including studies involving the respiratory chemoreflex system. Although transfer entropy is a useful tool in this avenue, no study to date has investigated how different transfer entropy estimation methods perform in typical biomedical applications featuring small sample size and presence of outliers. With respect to detection of increased coupling strength, we compared three transfer entropy estimation techniques using both simulated time series and respiratory recordings from lambs. The following estimation methods were analyzed: fixed-binning with ranking, kernel density estimation (KDE), and the Darbellay-Vajda (D-V) adaptive partitioning algorithm extended to three dimensions. In the simulated experiment, sample size was varied from 50 to 200, while coupling strength was increased. In order to introduce outliers, the heavy-tailed Laplace distribution was utilized. In the lamb experiment, the objective was to detect increased respiratory-related chemosensitivity to O 2 and CO 2 induced by a drug, domperidone. Specifically, the separate influence of end-tidal PO 2 and PCO 2 on minute ventilation before and after administration of domperidone was analyzed. In the simulation, KDE detected increased coupling strength at the lowest SNR among the three methods. In the lamb experiment, D-V partitioning resulted in the statistically strongest increase in transfer entropy post-domperidone for . In addition, D-V partitioning was the only method that could detect an increase in transfer entropy for , in agreement with experimental findings. Transfer entropy is capable of detecting directional coupling changes in non-linear biomedical time series analysis featuring a small number of observations and presence of outliers. The results of this study suggest that fixed-binning, even with ranking, is too primitive, and although there is no clear winner between KDE and D-V partitioning, the reader should note that KDE requires more computational time and extensive parameter selection than D-V partitioning. We hope this study provides a guideline for selection of an appropriate transfer entropy estimation method.