Xuan Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xuan Liu has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Jin U. Kang
Department of Electrical and Computer Engineering, The Johns Hopkins University, Baltimore, Maryland 21218, USA
9 shared publicationsYong Huang
Department of Electrical and Computer Engineering, The Johns Hopkins University, Baltimore, MD, 21218 USA
5 shared publications- Jessica C. Ramella-Roman
Department of Biomedical Engineering, Florida International University, Miami, FL 33199, USA
2 shared publications Russell H. Taylor
Laboratory for Computational Sensing and Robotics, Center for Computer-Integrated Surgical Systems and Technology, Johns Hopkins University, Baltimore, MD 21218, USA
2 shared publications- Iulian Iordachita
Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, MD 21218, USA
1 shared publication - Jin U. Kang
Johns Hopkins University, Department of Electrical and Computer Engineering, Baltimore, Maryland, United States
1 shared publication
Latest Publications
- 22 July 2013
- Published by Optica Publishing Group in Optics Letters
- Vol. 38 (15) , 2660-2662
Optimization of an angled fiber probe for common-path optical coherence tomography
We studied the optimization of common-path optical coherence tomography (CP OCT) sensitivity through an angled fiber probe. The magnitude of reference power derived from the tip of the fiber was optimized through careful selection of the polishing angle. We experimentally measured the signal-to-noise ratio (SNR) at different polishing angles to validate the effectiveness of this technique. We also obtained OCT images with the reference optimized CP OCT with more than 8 dB improvement in SNR.
- 22 July 2013
- Published by Optica Publishing Group in Optics Letters
- Vol. 38 (15) , 2660-2662
Optimization of an angled fiber probe for common-path optical coherence tomography
We studied the optimization of common-path optical coherence tomography (CP OCT) sensitivity through an angled fiber probe. The magnitude of reference power derived from the tip of the fiber was optimized through careful selection of the polishing angle. We experimentally measured the signal-to-noise ratio (SNR) at different polishing angles to validate the effectiveness of this technique. We also obtained OCT images with the reference optimized CP OCT with more than 8 dB improvement in SNR.
- 1 March 2013
- Published by Optica Publishing Group in Optics Letters
- Vol. 38 (5) , 805-807
Quantitative transverse flow measurement using optical coherence tomography speckle decorrelation analysis
We propose an inter-Ascan speckle decorrelation based method that can quantitatively assess blood flow normal to the direction of the optical coherence tomography imaging beam. To validate this method, we performed a systematic study using both phantom and in vivo animal models. Results show that our speckle analysis method can accurately extract transverse flow speed with high spatial and temporal resolution.
- 1 March 2013
- Published by Optica Publishing Group in Optics Letters
- Vol. 38 (5) , 805-807
Quantitative transverse flow measurement using optical coherence tomography speckle decorrelation analysis
We propose an inter-Ascan speckle decorrelation based method that can quantitatively assess blood flow normal to the direction of the optical coherence tomography imaging beam. To validate this method, we performed a systematic study using both phantom and in vivo animal models. Results show that our speckle analysis method can accurately extract transverse flow speed with high spatial and temporal resolution.
- 12 December 2012
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 30 (1) , 51-59
Robust spectral-domain optical coherence tomography speckle model and its cross-correlation coefficient analysis
In this study, we propose a generic speckle simulation for optical coherence tomography (OCT) signal, by convolving the point-spread function (PSF) of the OCT system with the numerically synthesized random sample field. We validate our model and use the simulation method to study the statistical properties of cross-correlation coefficients between A-scans, which have been recently applied in transverse motion analysis by our group. The results of simulation show that oversampling is essential for accurate motion tracking; exponential decay of OCT signal leads to an underestimate of motion that can be corrected; lateral heterogeneity of sample leads to an overestimate of motion for a few pixels corresponding to the structural boundary.
- 12 December 2012
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 30 (1) , 51-59
Robust spectral-domain optical coherence tomography speckle model and its cross-correlation coefficient analysis
In this study, we propose a generic speckle simulation for optical coherence tomography (OCT) signal, by convolving the point-spread function (PSF) of the OCT system with the numerically synthesized random sample field. We validate our model and use the simulation method to study the statistical properties of cross-correlation coefficients between A-scans, which have been recently applied in transverse motion analysis by our group. The results of simulation show that oversampling is essential for accurate motion tracking; exponential decay of OCT signal leads to an underestimate of motion that can be corrected; lateral heterogeneity of sample leads to an overestimate of motion for a few pixels corresponding to the structural boundary.
- Open Access
- 6 July 2012
- Published by Optica Publishing Group in Optics Express
- Vol. 20 (15) , 16567-16583
Distortion-free freehand-scanning OCT implemented with real-time scanning speed variance correction
Hand-held OCT systems that offer physicians greater freedom to access imaging sites of interest could be useful for many clinical applications. In this study, by incorporating the theoretical speckle model into the decorrelation function, we have explicitly correlated the cross-correlation coefficient to the lateral displacement between adjacent A-scans. We used this model to develop and study a freehand-scanning OCT system capable of real-time scanning speed correction and distortion-free imaging—for the first time to the best our knowledge. To validate our model and the system, we performed a series of calibration experiments. Experimental results show that our method can extract lateral scanning distance. In addition, using the manually scanned hand-held OCT system, we obtained OCT images from various samples by freehand manual scanning, including images obtained from human in vivo.
- 6 July 2012
- Published by Optica Publishing Group in Optics Express
- Vol. 20 (15) , 16567-16583
Open AccessDistortion-free freehand-scanning OCT implemented with real-time scanning speed variance correction
Hand-held OCT systems that offer physicians greater freedom to access imaging sites of interest could be useful for many clinical applications. In this study, by incorporating the theoretical speckle model into the decorrelation function, we have explicitly correlated the cross-correlation coefficient to the lateral displacement between adjacent A-scans. We used this model to develop and study a freehand-scanning OCT system capable of real-time scanning speed correction and distortion-free imaging—for the first time to the best our knowledge. To validate our model and the system, we performed a series of calibration experiments. Experimental results show that our method can extract lateral scanning distance. In addition, using the manually scanned hand-held OCT system, we obtained OCT images from various samples by freehand manual scanning, including images obtained from human in vivo.
- Open Access
- 19 April 2012
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 3 (5) , 1062-1076
Miniature fiber-optic force sensor based on low-coherence Fabry-Pérot interferometry for vitreoretinal microsurgery
During vitreoretinal surgery, the surgeon manipulates retinal tissue with tool-to-tissue interaction forces below the human sensory threshold. A force sensor (FS) integrated with conventional surgical tools may significantly improve the surgery outcome by providing tactile feedback to the surgeon. We designed and built a surgical tool integrated with a miniature FS with an outer diameter smaller than 1 mm for vitreoretinal surgery based on low-coherence Fabry–Pérot (FP) interferometry. The force sensing elements are located at the tool tip which is in direct contact with tissue during surgery and the FP cavity length is interrogated by a fiber-optic common-path phase-sensitive optical coherence tomography (OCT) system. We have calibrated the FS's response to axial and lateral forces and conducted experiments to verify that our FS can simultaneously measure both axial and lateral force components.
- 19 April 2012
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 3 (5) , 1062-1076
Open AccessMiniature fiber-optic force sensor based on low-coherence Fabry-Pérot interferometry for vitreoretinal microsurgery
During vitreoretinal surgery, the surgeon manipulates retinal tissue with tool-to-tissue interaction forces below the human sensory threshold. A force sensor (FS) integrated with conventional surgical tools may significantly improve the surgery outcome by providing tactile feedback to the surgeon. We designed and built a surgical tool integrated with a miniature FS with an outer diameter smaller than 1 mm for vitreoretinal surgery based on low-coherence Fabry–Pérot (FP) interferometry. The force sensing elements are located at the tool tip which is in direct contact with tissue during surgery and the FP cavity length is interrogated by a fiber-optic common-path phase-sensitive optical coherence tomography (OCT) system. We have calibrated the FS's response to axial and lateral forces and conducted experiments to verify that our FS can simultaneously measure both axial and lateral force components.
- Open Access
- 4 October 2011
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 2 (11) , 2995-3009
Spectroscopic-speckle variance OCT for microvasculature detection and analysis
We propose and studied optical coherence tomography (OCT) combining spectroscopic (SOCT) and speckle variance (svOCT) functions to effectively detect locations of microvasculatures and assess blood oxygen saturation level. Chorioallantoic membrane of a chick embryo was imaged in vivo to perform the analysis of the system. We also studied the effect of speckle in spectral domain using experimental data and performed time-averaging to reduce speckle noise locally. We combined SOCT and svOCT images using hue, saturation and value (HSV) color map to show the localized spectroscopic property of blood. Results show distinct spectroscopic properties between arterial blood and capillary blood.
- 4 October 2011
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 2 (11) , 2995-3009
Open AccessSpectroscopic-speckle variance OCT for microvasculature detection and analysis
We propose and studied optical coherence tomography (OCT) combining spectroscopic (SOCT) and speckle variance (svOCT) functions to effectively detect locations of microvasculatures and assess blood oxygen saturation level. Chorioallantoic membrane of a chick embryo was imaged in vivo to perform the analysis of the system. We also studied the effect of speckle in spectral domain using experimental data and performed time-averaging to reduce speckle noise locally. We combined SOCT and svOCT images using hue, saturation and value (HSV) color map to show the localized spectroscopic property of blood. Results show distinct spectroscopic properties between arterial blood and capillary blood.
- Open Access
- 1 April 2011
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 16 (04) , 046003-8
Dark-field illuminated reflectance fiber bundle endoscopic microscope
Various endoscopic microscopy techniques have been developed for in situ pathology and visual examinations. Flexible optical fiber bundles have been widely used in such endoscopic microscopy applications. 1, 2, 3, 4, 5, 6, 7, 8, 9 The use of a fiber bundle allows visual access to the specimen deep within the body cavity. The fiber bundle imaging also offers a very simple imaging probe configuration, which is why it is widely favored by many endoscopic applications. By using an imaging fiber bundle for light delivery, a scanning mechanism in front of the specimen can be eliminated and images can be formed by scanning a focused light spot at the proximal end of the fiber bundle, pixel by pixel, as in fiber bundle-based laser scanning fluorescence imaging,1 fiber confocal reflectance microscopy,2 two-photon imaging,3 and optical coherence tomography. 4, 5, 6 Such a system can achieve high spatial resolution and large dynamic range. A simpler endoscopic configuration is a scanless fiber bundle endoscopic imager interfaced with a 2D camera for direct imaging of tissue. 7, 10 It is an attractive design to use only one fiber bundle for illumination and image acquisition in a reflectance fiber-bundle microscope (RFM), since such a design can help further miniaturize the endoscopic probe and reduce the system cost. However, dual illumination and image acquisition configuration has an inherent drawback: the specular reflectance from the end facets of the fiber bundle can be orders of magnitude larger than the backscattered light from the sample. 11, 12 The specular reflection takes up a significant part of the limited dynamic range of the detector and thus decreases the image contrast. The resultant large background level also increases the overall noise level, which hinders the efficient detection of the signals of interest. Recently, Sun used a cross polarization detection technique in the reflectance fiber bundle endoscope setup to suppress the specular reflection from the proximal end of the fiber bundle.10
- 1 April 2011
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 16 (04) , 046003-8
Open AccessDark-field illuminated reflectance fiber bundle endoscopic microscope
Various endoscopic microscopy techniques have been developed for in situ pathology and visual examinations. Flexible optical fiber bundles have been widely used in such endoscopic microscopy applications. 1, 2, 3, 4, 5, 6, 7, 8, 9 The use of a fiber bundle allows visual access to the specimen deep within the body cavity. The fiber bundle imaging also offers a very simple imaging probe configuration, which is why it is widely favored by many endoscopic applications. By using an imaging fiber bundle for light delivery, a scanning mechanism in front of the specimen can be eliminated and images can be formed by scanning a focused light spot at the proximal end of the fiber bundle, pixel by pixel, as in fiber bundle-based laser scanning fluorescence imaging,1 fiber confocal reflectance microscopy,2 two-photon imaging,3 and optical coherence tomography. 4, 5, 6 Such a system can achieve high spatial resolution and large dynamic range. A simpler endoscopic configuration is a scanless fiber bundle endoscopic imager interfaced with a 2D camera for direct imaging of tissue. 7, 10 It is an attractive design to use only one fiber bundle for illumination and image acquisition in a reflectance fiber-bundle microscope (RFM), since such a design can help further miniaturize the endoscopic probe and reduce the system cost. However, dual illumination and image acquisition configuration has an inherent drawback: the specular reflectance from the end facets of the fiber bundle can be orders of magnitude larger than the backscattered light from the sample. 11, 12 The specular reflection takes up a significant part of the limited dynamic range of the detector and thus decreases the image contrast. The resultant large background level also increases the overall noise level, which hinders the efficient detection of the signals of interest. Recently, Sun used a cross polarization detection technique in the reflectance fiber bundle endoscope setup to suppress the specular reflection from the proximal end of the fiber bundle.10
- Open Access
- 5 November 2010
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (23) , 24331-24343
Towards automatic calibration of Fourier-Domain OCT for robot-assisted vitreoretinal surgery
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- 5 November 2010
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (23) , 24331-24343
Open AccessTowards automatic calibration of Fourier-Domain OCT for robot-assisted vitreoretinal surgery
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- Open Access
- 1 October 2010
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (21) , 22010-22019
Compressive SD-OCT: the application of compressed sensing in spectral domain optical coherence tomography
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- 1 October 2010
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (21) , 22010-22019
Open AccessCompressive SD-OCT: the application of compressed sensing in spectral domain optical coherence tomography
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- 15 July 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 57 (10) , 2572-2575
Depth-Resolved Blood Oxygen Saturation Assessment Using Spectroscopic Common-Path Fourier Domain Optical Coherence Tomography
Although spectroscopic optical coherence tomography (OCT) has been shown to be a promising method for measuring blood oxygen saturation with high-spatial resolution and accuracy, there are several technical issues that need to be addressed before it could become a practical method. In this letter, we have attempted to address two issues that could significantly improve the quantitative assessment of blood oxygen saturation level. First, we have implemented a spectral normalization technique to eliminate the spectral modulation induced by the wavelength-distance-dependent point spread function (PSF) of OCT's. Second, to reduce the spectral speckle noise due to the highly scattering blood, we have implemented a spatial low-pass filter to the 2-D OCT dataset consisting of spectra obtained at different lateral positions. We have assessed the effectiveness of these methods using common-path OCT system. Results showed that we were able to extract unambiguous depth-resolved, SO2-dependent spectroscopic information from 1-D and 2-D OCT images, which could be used to accurately assess the SO2 level.
- 15 July 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 57 (10) , 2572-2575
Depth-Resolved Blood Oxygen Saturation Assessment Using Spectroscopic Common-Path Fourier Domain Optical Coherence Tomography
Although spectroscopic optical coherence tomography (OCT) has been shown to be a promising method for measuring blood oxygen saturation with high-spatial resolution and accuracy, there are several technical issues that need to be addressed before it could become a practical method. In this letter, we have attempted to address two issues that could significantly improve the quantitative assessment of blood oxygen saturation level. First, we have implemented a spectral normalization technique to eliminate the spectral modulation induced by the wavelength-distance-dependent point spread function (PSF) of OCT's. Second, to reduce the spectral speckle noise due to the highly scattering blood, we have implemented a spatial low-pass filter to the 2-D OCT dataset consisting of spectra obtained at different lateral positions. We have assessed the effectiveness of these methods using common-path OCT system. Results showed that we were able to extract unambiguous depth-resolved, SO2-dependent spectroscopic information from 1-D and 2-D OCT images, which could be used to accurately assess the SO2 level.