HMHui Meng

Hui Meng

*This is an algorithmically generated author record based on publicly available information.

Hui Meng has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Suchuan Dong

    Center for Computational and Applied Mathematics, Department of Mathematics, Purdue University, West Lafayette, IN 47907, USA

    2 shared publications
  • Ye Pu

    Loser Flow Diagnostics Laboratory, Department of Mechanical and Aerospace Engineering, State University of New York at Buffalo, Buffalo, New York 14260, USA

    2 shared publications
  • Aruj Ahluwalia

    Epic Systems

    1 shared publication
  • Dale B. Taulbee

    Department of Mechanical and Aerospace Engineering, University at Buffalo, Buffalo, NY 14260

    1 shared publication
  • Gang Pan

    State University of New York at Buffalo, Buffalo, NY

    1 shared publication
  • J. Sheng

    Department of Mechanical Engineering Johns Hopkins University Baltimore, MD 21218, USA TP

    1 shared publication

Latest Publications

  • Digital holographic particle validation via complex wave

    by Jeremy de Jong, Hui Meng

    The inability to distinguish between particle images and noise in holographic reconstruction of dense particle fields hampers the advancement of holographic particle diagnostic techniques including holographic particle image velocimetry. We developed a method to separate particles from the noise by unlocking a unique particle signature in the complex reconstructed field. This complex-wave signature is present in digital particle holograms recorded at any scattering angle. Simulations of single and multiple particle holograms, as well as preliminary laboratory particle-field experiments, not only demonstrated the existence of the particle signature but also evaluated its ability to remove noise. Regardless of particle seeding density, scattering angle of hologram recording and particle size range, the particle identification∕validation routine consistently provides >50% removal of “bad” particles and <8% of good particles.


  • Validation of CFD Simulations of Cerebral Aneurysms With Implication of Geometric Variations

    by Yiemeng Hoi, Scott H. Woodward, Minsuok Kim, Dale B. Taulbee, Hui Meng

    Background. Computational fluid dynamics (CFD) simulations using medical-image-based anatomical vascular geometry are now gaining clinical relevance. This study aimed at validating the CFD methodology for studying cerebral aneurysms by using particle image velocimetry (PIV) measurements, with a focus on the effects of small geometric variations in aneurysm models on the flow dynamics obtained with CFD. Method of Approach. An experimental phantom was fabricated out of silicone elastomer to best mimic a spherical aneurysm model. PIV measurements were obtained from the phantom and compared with the CFD results from an ideal spherical aneurysm model (S1). These measurements were also compared with CFD results, based on the geometry reconstructed from three-dimensional images of the experimental phantom. We further performed CFD analysis on two geometric variations, S2 and S3, of the phantom to investigate the effects of small geometric variations on the aneurysmal flow field. Results. We found poor agreement between the CFD results from the ideal spherical aneurysm model and the PIV measurements from the phantom, including inconsistent secondary flow patterns. The CFD results based on the actual phantom geometry, however, matched well with the PIV measurements. CFD of models S2 and S3 produced qualitatively similar flow fields to that of the phantom but quantitatively significant changes in key hemodynamic parameters such as vorticity, positive circulation, and wall shear stress. Conclusion. CFD simulation results can closely match experimental measurements as long as both are performed on the same model geometry. Small geometric variations on the aneurysm model can significantly alter the flow-field and key hemodynamic parameters. Since medical images are subjected to geometric uncertainties, image-based patient-specific CFD results must be carefully scrutinized before providing clinical feedback.


  • Four-dimensional dynamic flow measurement by holographic particle image velocimetry

    by Ye Pu, Hui Meng

    The ultimate goal of holographic particle image velocimetry (HPIV) is to provide space- and time-resolved measurement of complex flows. Recent new understanding of holographic imaging of small particles, pertaining to intrinsic aberration and noise in particular, has enabled us to elucidate fundamental issues in HPIV and implement a new HPIV system. This system is based on our previously reported off-axis HPIV setup, but the design is optimized by incorporating our new insights of holographic particle imaging characteristics. Furthermore, the new system benefits from advanced data processing algorithms and distributed parallel computing technology. Because of its robustness and efficiency, for the first time to our knowledge, the goal of both temporally and spatially resolved flow measurements becomes tangible. We demonstrate its temporal measurement capability by a series of phase-locked dynamic measurements of instantaneous three-dimensional, three-component velocity fields in a highly three-dimensional vortical flow—the flow past a tab.


  • Intrinsic speckle noise in off-axis particle holography.

    by Ye Pu, Hui Meng

    In holographic imaging of particle fields, the interference among coherent wave fronts associated with particle scattering gives rise to intrinsic speckle noise, which sets a fundamental limit on the amount of information that particle holography can deliver. It has been established that the intrinsic speckle noise is especially severe in in-line holography because of superposition of virtual image waves, the direct transmitted wave, and the real image. However, at sufficiently high particle number densities, such as those typical in holographic particle image velocimetry (HPIV) applications, intrinsic speckle noise also arises in off-axis particle holography from self-interference among wave fronts that form the real image of particles. To overcome the latter problem we have constructed a mathematical model that relates the first- and second-order statistical properties of the intrinsic speckle noise to relevant holographic system parameters. Consistent with our experimental data, the model provides a direct estimate of the information capacity of particle holography. We show that the noise-limited information capacity can be expressed as the product of particle number density and the extent of the particle field along the optical axis. A large angular aperture of the hologram contributes directly to achievement of high information capacity. We also show that filtering in either digital or optical form is generally ineffective in removing the intrinsic speckle noise from the particle image as a result of the similar spectral properties of the two. These findings emphasize the importance of angular aperture in designing holographic particle imaging systems.


  • Flow past a trapezoidal tab

    by Suchuan Dong, Hui Meng

    The flow passing over a trapezoidal tab mounted on a flat plate is studied using direct numerical simulation (DNS). Such a tab has been used to generate hairpin-like vortices to enhance cross-stream mixing. We attempt to provide a detailed account of the three-dimensional topology and dynamics of the hairpin vortices in the tab wake. Simulations are conducted for three tab inclination angles at Reynolds number $\hbox{\it Re}\,{=}\,600$ based on the free-stream velocity and the tab height. A finite-volume discretization scheme involving $2.6\,{\times}\, 10^6$ control volumes is employed for the simulations and the results are compared with PIV experimental data. Simulations captured all the experimentally observed near-field flow features including a pair of streamwise co-rotating vortices and its transition to hairpin vortices. Simulation results provide new insight into the vortex dynamics in the tab wake. It is shown that the hairpin vortex is capable of lifting up and entraining vorticity from the local boundary layer, thereby increasing its strength to counter the vorticity diffusion. It is also observed that the turbulence production is mostly accomplished by the hairpin heads/arches, while the highest kinetic energy is associated with hairpin vortex legs. The topological characteristics of the structures and the statistical characteristics of the flow are discussed in detail.


  • Intrinsic aberrations due to Mie scattering in particle holography

    by Ye Pu, Hui Meng

    Holography of small particles is a newly revived topic because of its importance in holographic particle image velocimetry (HPIV). However, the property of particle images formed through holography remains largely unexplored. This fact undermines the measurement reliability of HPIV techniques and has become one of the obstacles in the full deployment of HPIV. We study the intrinsic aberrations in the holographic particle image introduced by particle light scattering and investigate how accurately holography can deliver information about the particles that are being imaged. Consistent with our experimental observations, simulations based on Mie scattering theory show that even with a perfect hologram the reconstructed particle images demonstrate complex three-dimensional morphologies and bodily shifts. These characteristics, manifested as image aberrations, result from uneven scattering amplitude and phase distributions across the finite aperture of the hologram. Such aberrations degrade the signal-to-noise ratio in the reconstructed image as well as introducing systematic errors in detected particle image positions. We examine the effect of these aberrations on HPIV measurements.


  • Open Access

    Turbulent Coagulation of Aerosol Particles: New Insights From Direct Numerical Simulations and Holographic Imaging Experiments

    by Lance R. Collins, Hui Meng, Aruj Ahluwalia, Lujie Cao, Gang Pan

    Particle collisions driven by turbulent fluctuations play a key role in such diverse problems as cloud formation, aerosol powder manufacturing and inhalation drug therapy to name a few. In all of these examples (and many others) turbulent fluctuations increase the rate of collisions relative to the background collision rate driven by Brownian motion. Furthermore, turbulence can spontaneously generate very large fluctuations in the particle concentration field. This “clustering” is caused by the inertial mismatch between the heavy particles and the lighter surrounding gas; vortices in the flow “centrifuge” the heavier particles out of vortex cores and into the straining regions that lie in between the vortices. Because collision is a binary process, concentration fluctuations further enhance the turbulent coagulation rate by as much as two orders of magnitude. An effect of this size must be accounted for in a rational model of turbulent coagulation. Sundaram & Collins (J. Fluid Mech. 1997) showed that the radial distribution function (RDF) of the particle population, evaluated at contact, precisely corrects the collision kernel for clustering. Subsequent work has explored the dependence of the RDF on the system parameters (e.g., particle size, concentration, response time and Reynolds number) using direct numerical simulations. These results have improved our understanding and ability to predict the effect of the first three parameters; however, owing to the limited range of Reynolds number that can be reached in a numerical simulation, questions remain over the scaling of the RDF with Reynolds number. This is a critical issue for high-Reynolds-number applications such as cloud physics, where values of the Reynolds number can be 1–2 orders of magnitude greater than can be simulated. We will present our highest Reynolds number simulations to date and show our attempts to resolve this issue. Recently, the ability to measure three-dimensional particle positions using holography has been realized (e.g., Meng & Pu, J. Opt. Soc. Am. 2003). With holography, the optical image that is produced contains fringes that, upon inverting the laser, reproduce the original image in three dimensions. The hologram can then be scanned using a digital camera to obtain the particle positions. An important consideration with this study is the need to differentiate individual particles. We developed a search algorithm that locates particle centers, even in the presence of optical aberations and speckle noise. The algorithm has been used to obtain the first experimental RDF measurements to date. Thus far we see good agreement between the experimentally obtained RDF and the simulations. Besides validating the simulations, experiments can span a much broader range of Reynolds numbers, providing critical data that may help resolve the open questions associated with this parameter.