DSDavid J. Stickler

David J. Stickler

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


David J. Stickler has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The encrustation and blockage of long-term indwelling bladder catheters: a way forward in prevention and control

    by D J Stickler, R C L Feneley

    To review the literature showing that understanding how Foley catheters become encrusted and blocked by crystalline bacterial biofilms has led to strategies for the control of this complication in the care of patients undergoing long-term indwelling bladder catheterization. A comprehensive PubMed search of the literature published between 1980 and December 2009 was made for relevant articles using the Medical Subject Heading terms 'biofilms', 'urinary catheterization', 'catheter-associated urinary tract infection' and 'urolithiasis'. Papers on catheter-associated urinary tract infections and bacterial biofilms collected during 40 years of working in the field were also reviewed. There is strong experimental and epidemiological evidence that infection by Proteus mirabilis is the main cause of the crystalline biofilms that encrust and block Foley catheters. The ability of P. mirabilis to generate alkaline urine and to colonize all available types of indwelling catheters allows it to take up stable residence in the catheterized tract in bladder stones and cause recurrent catheter blockage. The elimination of P. mirabilis by antibiotic therapy as soon as it appears in the catheterized urinary tract could improve the quality of life for many patients and reduce the current expenditure of resources when managing the complications of catheter encrustation and blockage. For patients who are already chronic blockers and stone formers, antibiotic treatment is unlikely to be effective owing to the resistance of cells in the crystalline biofilms. Strategies such as increasing fluid intake with citrated drinks could control the problem until bladder stone removal can be organized.


  • Crystalline bacterial biofilm formation on urinary catheters by urease-producing urinary tract pathogens: a simple method of control

    by Robert J. Broomfield, Sheridan D. Morgan, Azhar Khan, David J. Stickler

    The problem of catheter encrustation stems from infection by urease-producing bacteria. These organisms generate ammonia from urea, elevate the pH of urine and cause crystals of calcium and magnesium phosphates to form in the urine and the biofilm that develops on the catheter. In this study, a laboratory model was used to compare the ability of 12 urease-positive species of urinary tract pathogens to encrust and block catheters. Proteus mirabilis, Proteus vulgaris and Providencia rettgeri were able to raise the urinary pH above 8.3 and produce catheter-blocking crystalline biofilms within 40 h. Morganella morganii and Staphylococcus aureus elevated the pH of urine to 7.4 and 6.9, respectively, and caused some crystal deposition in the biofilms but did not block catheters in the 96 h experimental period. Isolates of Klebsiella pneumoniae, Klebsiella oxytoca, Enterobacter cloacae, Serratia marcescens, Pseudomonas aeruginosa and Providencia stuartii were only capable of raising the pH of urine to a maximum of 6.4 and failed to cause crystal deposition in the biofilm. The most effective way to prevent catheter encrustation was shown to be diluting urine and increasing its citrate concentration. This strategy raises the nucleation pH (pHn) at which calcium and magnesium phosphates crystallize from urine. Increasing the fluid intake of a healthy volunteer with citrated drinks resulted in urine with a pHn of >8.0 in which catheter encrustation was inhibited. It is suggested that this dietary strategy will be an effective means of controlling catheter encrustation, whichever bacterial species is causing the problem.


  • A study of the structure of the crystalline bacterial biofilms that can encrust and block silver Foley catheters

    by Sheridan D. Morgan, Deborah Rigby, David J. Stickler

    The aim of this study was to examine the structure of the crystalline bacterial biofilms that encrust and block silver/hydrogel-coated latex catheters. Scanning electron microscopy was used to examine the crystalline deposits that were found encrusting catheters obtained from six patients undergoing long-term catheterization in a community setting. Large populations of bacilli and cocci were seen on all catheters developing on a basal foundation layer of crystalline material. These observations show that in patients prone to catheter encrustation, crystalline material formed in the urine can cover the surfaces of silver catheters. Extensive bacterial biofilms then develop on the crystals, shielded from the underlying silver. It is suggested that if antimicrobials are to be incorporated into catheters to prevent encrustation, they must diffuse out from the catheter surface and reduce the viable cell populations of the urease producing bacteria that elevate the urinary pH and trigger crystal formation.


  • Top Cited Papers

    Bacterial biofilms in patients with indwelling urinary catheters

    by David J Stickler

    Bacteria have a basic survival strategy: to colonize surfaces and grow as biofilm communities embedded in a gel-like polysaccharide matrix. The catheterized urinary tract provides ideal conditions for the development of enormous biofilm populations. Many bacterial species colonize indwelling catheters as biofilms, inducing complications in patients' care. The most troublesome complications are the crystalline biofilms that can occlude the catheter lumen and trigger episodes of pyelonephritis and septicemia. The crystalline biofilms result from infection by urease-producing bacteria, particularly Proteus mirabilis. Urease raises the urinary pH and drives the formation of calcium phosphate and magnesium phosphate crystals in the biofilm. All types of catheter are vulnerable to encrustation by these biofilms, and clinical prevention strategies are clearly needed, as bacteria growing in the biofilm mode are resistant to antibiotics. Evidence indicates that treatment of symptomatic, catheter-associated urinary tract infection is more effective if biofilm-laden catheters are changed before antibiotic treatment is initiated. Infection with P. mirabilis exposes the many faults of currently available catheters, and plenty of scope exists for improvement in both their design and production; manufacturers should take up the challenge to improve patient outcomes.


  • Reduced Susceptibility of Proteus mirabilis to Triclosan

    by David J. Stickler, Gwennan L. Jones

    Clinical isolates of Proteus mirabilis causing catheter encrustation and blockage are susceptible to the biocide triclosan (MICs of 0.2 mg/liter). Studies with laboratory models of the bladder have demonstrated that the inflation of catheter retention balloons with triclosan solutions rather than water results in the diffusion of triclosan from the balloons into the surrounding urine and the inhibition of catheter encrustation by P. mirabilis . The aim of this study was to test whether the exposure of P. mirabilis to triclosan under laboratory conditions resulted in the selection of strains with reduced susceptibilities to this biocide. Exposure to triclosan in agar was shown to select mutants with MICs elevated from 0.2 mg/liter up to 80 mg/liter. In a selection of 14 of these strains, the decreased susceptibility was found to be stable and not associated with increased resistance to antibiotics. Experiments with the laboratory models demonstrated that inflation of the catheter balloons with triclosan (10 mg/ml) prevented encrustation and blockage by the parent strain P. mirabilis B2 (MIC, 0.2 mg/liter) and the mutant strain M48 (MIC, 2.0 mg/liter) but had no effect on crystalline biofilm formation by strain M55 (MIC, 40 mg/liter). These results suggest that, in any clinical trial or subsequent clinical use of the strategy, it will be important to monitor the urinary flora of the catheterized patients for P. mirabilis strains with reduced susceptibility to triclosan. The emergence of these strains could undermine the ability of the triclosan strategy to control catheter encrustation.


  • Species interactions in mixed-community crystalline biofilms on urinary catheters

    by Sarah M. Macleod, David J. Stickler

    Previous experimental investigations of the crystalline biofilms that colonize and block urinary catheters have focussed on their formation by pure cultures of Proteus mirabilis. In the urine of patients undergoing long-term catheterization, P. mirabilis is commonly found in mixed communities with other urinary tract pathogens. Little is known about the effect that the other species have on the rate at which P. mirabilis encrusts catheters. In the present study, a set of data on the nature of the bacterial communities on 106 catheter biofilms has been analysed and it was found that while species such as Providencia stuartii and Klebsiella pneumoniae were commonly associated with P. mirabilis, when Escherichia coli, Morganella morganii or Enterobacter cloacae were present, P. mirabilis was rarely or never found. The hypothesis that the absence of P. mirabilis from some biofilm communities could be due to its active exclusion by other species has also been examined. Experiments in laboratory models showed that co-infection of P. mirabilis with M. morganii, K. pneumoniae or E. coli had no effect on the ability of P. mirabilis to encrust and block catheters. Co-infection with Ent. cloacae or Pseudomonas aeruginosa, however, significantly increased the time that catheters took to block (P Ent. cloacae, M. morganii, K. pneumoniae or E. coli in the model for 72 h prior to superinfection with P. mirabilis significantly delayed catheter blockage. In the case of Ent. cloacae, for example, the mean time to blockage was extended from 28.7 h to 60.7 h (P ≤0.01). In all cases, however, P. mirabilis was able to generate alkaline urine, colonize the biofilms, induce crystal formation and block the catheters. The results suggest that although there is a degree of antagonism between P. mirabilis and some of the other urinary tract organisms, the effects are temporary and whatever the pre-existing urinary microbiota, infection with P. mirabilis is thus likely to lead to catheter encrustation and blockage.


  • Open Access

    A clinical assessment of the performance of a sensor to detect crystalline biofilm formation on indwelling bladder catheters

    by David J. Stickler, Steven M. Jones, Gabriel O. Adusei, Mark G. Waters, Jenny Cloete, Sunil Mathur, Roger C.L. Feneley

    OBJECTIVES: To test the ability of a sensor developed to signal infection by the organisms that generate the crystalline biofilms that encrust catheters, to give an early warning that encrustation was occurring on patients’ catheters, as the care of many patients undergoing long‐term bladder catheterization is complicated by the encrustation and blockage of their catheters PATIENTS AND METHODS: Twenty patients were followed prospectively for the lifetime of one of their catheters. Sensors based on cellulose acetate/bromothymol blue were placed in the urine‐collection bags, which were changed as usual at weekly intervals. The bacteriology was assessed and pH determined weekly on urine samples. Photographic records were made of the sensors twice weekly. On removal, each catheter was examined for encrustation and blockage. RESULTS: Proteus mirabilis was not isolated from five patients and in these cases the sensor colour remained golden‐yellow to brown. The catheters drained for the scheduled period and showed no signs of encrustation. By contrast, the sensors turned dark blue/black in the urine of all 15 patients infected with P. mirabilis . All these patients’ catheters were encrusted and in 12 the catheters blocked. The mean interval between the sensor signalling and the catheter blocking was 12 days. CONCLUSION: The cellulose acetate/bromothymol blue sensors placed in the urine collection bags are capable of signalling infection by P. mirabilis . They also signal the early stages of catheter encrustation and allow catheter replacement in ample time to avoid the clinical crises and emergency referrals caused by catheter blockage.


  • Observations on the adherence of Proteus mirabilis onto polymer surfaces

    by D.J. Stickler, J.C. Lear, N.S. Morris, S.M. Macleod, A. Downer, D.H. Cadd, W.J. Feast

    Aims: Infection of the catheterized urinary tract with Proteus mirabilis causes blockage of the catheter by crystalline bacterial biofilms. The aim of this work is to identify a surface‐coating for catheters that is not vulnerable to colonization by Pr. mirabilis. Methods and Results: A parallel‐plate flow‐cell and phase contrast microscopy were used to follow bacterial adhesion onto polymer films. Experiments with a urease‐negative mutant of Pr. mirabilis suspended in buffer or urine, identified agarose as a polymer on which biofilm did not form. In tests with wild‐type urease‐producing cells in urine, no adhesion of cells onto agarose was observed for 3 h but then as the pH rose above 8·2, the surface rapidly became colonized by crystalline biofilm. Conclusions: In urine at pH below 8·0, Pr. mirabilis does not adhere to agarose‐coated surfaces. When the pH rises above 8·2, however, aggregates of crystals and bacteria form in the urine and are deposited on such surfaces. Significance and Impact of the Study: Strategies to prevent the formation of crystalline biofilms on urinary catheters will need to consider both the properties of the surface‐coatings and the requirement to prevent the alkaline conditions that induce crystal formation in urine.