MWMareike Warkentin

Mareike Warkentin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mareike Warkentin has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Marginal Fit Evaluation of Zirconia Copings Based on Conventional and Digital Impressions Using a Tooth Section Microscopic Examination Technique

    by Marc Schulze, Peter Ottl, Mareike Warkentin

    Background/Objectives: This study compared the marginal fit of CAD/CAM zirconia copings based on digital and conventional impression techniques by using a new method of tooth section examination. Methods: Twenty premolars were prepared for an all-ceramic full crown. Ten conventional impressions using the polyether Impregum and ten digital impressions using the cara TRIOS intraoral scanner were used to fabricate zirconia copings. Slices were prepared by cutting each tooth five times. The marginal fit was microscopically analyzed using seven defined distances at 20 measuring points per tooth. The statistical analyses were carried out by using the Mann–Whitney test and the Kruskal–Wallis test (α = 0.05). Results: The median values for the copings based on the conventional (c) and digital (d) impressions showed significant differences for the internal gap (c: 56 μm (IQR = 22); d: 30 μm (IQR = 13); p < 0.001), horizontal marginal discrepancy (c: 64 μm (IQR = 59); d: 84 μm (IQR = 41); p < 0.001), absolute marginal discrepancy (c: 81 μm (IQR = 40); d: 98 μm (IQR = 50); p < 0.001) and the overextension (c: 63 μm (IQR = 48); d: 89 μm (IQR = 50); p < 0.001). All copings based on digital impressions were overextended. Underextensions only occurred with the conventional impression method with a median value of 40 μm (IQR = 64). For the marginal gap (c: 29 μm (IQR = 27); d: 31 μm (IQR = 22); p = 0.477) and the vertical marginal discrepancy (c: 34 μm (IQR = 32); d: 35 μm (IQR = 40); p = 0.944) no significant differences could be found. Conclusions: Both impression methods are suitable for the fabrication of ceramic copings. The microscopic examination of tooth sections seems to be a suitable in vitro method for the evaluation of the marginal fit of ceramic copings.

  • Open Access

    Changes in the Periodontal Gap After Long-Term Tooth Movement into Augmented Critical-Sized Defects in the Jaws of Beagle Dogs

    by Kathrin Duske, Mareike Warkentin, Anja Salbach, Jan-Hendrik Lenz, Franka Stahl

    Background/Objectives: Extensive and closely coordinated remodeling processes take place in the periodontal ligament (PDL) and the adjacent bone during orthodontic tooth movement. In complex orthodontic cases, it is necessary to move teeth into an augmented bony defect, for example, in patients with cleft lip, alveolus, and palate. The important role of the PDL during tooth movement is well accepted but not fully understood. Therefore, the present study investigated the PDL after 23 weeks of tooth movement into an augmented critical-sized defect. Methods: The second molars of four beagle dogs were moved into a critical-sized defect, which was filled with bovine xenograft or nanocrystalline hydroxyapatite. Autogenous bone served as control. After 23 weeks, histological samples were microscopically analyzed, and the dimension of the PDL was measured. For statistical calculations, a Wilcoxon–Mann–Whitney test was used. Results: The PDL was significantly wider on the tension side compared with the compression side for all replacement materials analyzed (p ≤ 0.05). These results apply to both the mesial and distal roots. Conclusions: The remodeling processes reached equilibrium within 23 weeks, resulting in a wider gap on the tension side, which contrasts with the situation a few days after the initial force application.

  • Open Access

    Influence of Test Specimen Geometry and Water Soaking on the In Vitro Cytotoxicity of Orthocryl®, Orthocryl® LC, Loctite® EA 9483 and Polypropylene

    by Richard Behnke, Franka Stahl, Kathrin Duske, Mareike Warkentin, Margit Schwartz, Burkhard Hinz, Udo Walther

    Depending on their composition, plastics have a cytotoxic potential that needs to be evaluated before they are used in dentistry, e.g., as orthodontic removable appliances. Relevant guidelines set out requirements that a potential new resin in the medical field must meet, with a wide scope for experimental design. In the present study, test specimens of different geometries consisting of varying polymers (Orthocryl®, Orthocryl® LC, Loctite® EA 9483, Polypropylene) were soaked for different periods of time, then transferred to cell culture medium for 24 h, which was subsequently used for 24-h cultivation of A549 cells, followed by cytotoxicity assays (WST-1, Annexin V-FITC-propidium iodide (PI) flow cytometry). In this context, a reduction in the cytotoxic effect of the eluates of test specimens prepared from Orthocryl® LC and Loctite® EA 9483 was particularly evident in the Annexin V-FITC-PI assay when the soaking time was extended to 48 h and 168 h, respectively. Consistent with this, a reduced release of potentially toxic monomers into the cell culture medium, as measured by gas chromatography-mass spectrometry, was observed when the prior soaking time of test specimens of all geometries was extended. Remarkably, a significant increase in cytotoxic effect was observed in the WST-1 assay, which was accompanied by a higher release of monomers when the thickness of the test sample was increased from 0.5 to 1.0 mm, although an elution volume adapted to the surface area was used. However, further increasing the thickness to 3.0 mm did not lead to an increase in the observed cytotoxicity or monomer release. Test specimens made of polypropylene showed no toxicity under all test specimen sizes and soaking time conditions. Overall, it is recommended to perform toxicity studies of test specimens using different geometries and soaking times. Thereby, the influence of the different specimen thicknesses should also be considered. Finally, an extension of the test protocols proposed in ISO 10993-5:2009 should be considered, e.g., by flow cytometry or monomer analysis as well as fixed soaking times.


  • Open Access

    Comparative Sample Preparation Using Focused Ion Beam and Ultramicrotomy of Human Dental Enamel and Dentine for Multimicroscopic Imaging at Micro- and Nanoscale

    by Katharina Witzke, Marcus Frank, Olaf Specht, Ute Schulz, Claudia Oehlschläger, Detlef Behrend, Peter Ottl, Mareike Warkentin

    (1) Background: The aim of this study was to systematically compare TEM sections of mineralized human enamel and dentine prepared by focused ion beam (in situ lift-out) technique and ultramicrotomy through a combination of microscopic examination methods (scanning electron microscopy and transmission electron microscopy). In contrast with published studies, we compared the TEM preparation methods using the same specimen blocks as those for the ultramicrotomy and FIB technique. (2) Methods: A further evaluation of TEM sample preparation was obtained by confocal laser scanning microscopy and atomic force microscopy. In addition, ultramicrotome- and focused ion beam-induced artefacts are illustrated. (3) Results: The FIB technique exposed a major difference between non-decalcified enamel and dentine concerning the ultrastructural morphology compared to ultramicrotome-prepared sections. We found that ultramicrotomy was useful for cutting mineralized dentine, with the possibility of mechanical artefacts, but offers limited options for the preparation of mineralized enamel. FIB preparation produced high-quality TEM sections, showing the anisotropic ultrastructural morphology in detail, with minor structural artefacts. Our results show that the solution of artificial saliva and glutardialdehyde (2.5% by volume) is a very suitable fixative for human mineralized tissue. (4) Conclusions: The protocol that we developed has strong potential for the preparation of mineralized biomaterials for TEM imaging and analysis.


  • Open Access

    Influence of artificial aging: mechanical and physicochemical properties of dental composites under static and dynamic compression

    by D. C. Gornig, R. Maletz, P. Ottl, M. Warkentin

    Objective: The aim of the study was to evaluate the influence of filler content, degradation media and time on the mechanical properties of different dental composites after in vitro aging. Materials and Methods: Specimens (1 mm3) of three commercially available composites (GrandioSO®, Arabesk Top®, Arabesk Flow®) with respect to their filler content were stored in artificial aging media: artificial saliva, ethanol (60%), lactic acid (pH 5) and citric acid (pH 5). Parameters (Vickers microhardness, compressive strength, elastic modulus, water sorption and solubility) were determined in their initial state (control group, n = 3 for microhardness, n = 5 for the other parameters) and after 14, 30, 90 and 180 days (n = 3 for microhardness, n = 5 for the other parameters for each composite group, time point and media). Specimens were also characterized with dynamic-mechanical-thermal analysis (compression tests, F = ± 7 N; f = 0.5 Hz, 1 Hz and 3.3 Hz; t = 0–170 °C). Results: Incorporation of fillers with more than 80 w% leads to significantly better mechanical properties under static and dynamic compression tests and a better water sorption behavior, even after chemical degradation. The influence of degradation media and time is of subordinate importance for chemical degradation. Conclusion: Although the investigated composites have a similar matrix, they showed different degradation behavior. Since dentine and enamel occur only in small layer thickness, a test specimen geometry with very small dimensions is recommended for direct comparison. Moreover, the use of compression tests to determine the mechanical parameters for the development of structure-compatible and functionally adapted composites makes sense as an additional standard. Clinical relevance Preferential use of highly filled composites for occlusal fillings is recommended.


  • Open Access

    Surface Characterization and Copper Release of a-C:H:Cu Coatings for Medical Applications

    by Stefan Nißen, Jan Heeg, Marion Wienecke, Detlef Behrend, Mareike Warkentin, Krzysztof Rokosz, Sofia Gaiaschi, Patrick Chapon

    This paper focuses on the surface properties of a-C:H:Cu composite coatings for medical devices and how the release of Cu2+ ions from such coatings can be controlled. The released Cu ions have the potential to act as a bactericidal agent and inhibit bacterial colonization. A PVD–PECVD hybrid process was used to deposit a-C:H:Cu composite coatings onto Ti6Al4V substrates. We examine the layer surface properties using atomic force microscopy and static contact angle measurements. An increasing surface roughness and increasing contact angle of Ringer’s solution was measured with increasing copper mole fraction (XCu) in the coatings. The contact angle decreased when a supplementary bias voltage of −50 V was used during the a-C:H:Cu deposition. These findings are in line with earlier published results regarding these types of coatings. The release of Cu2+ ions from a-C:H:Cu coatings in Ringer’s solution was measured by anodic stripping voltammetry. Different layer structures were examined to control the time-resolved Cu release. It was found that the Cu release depends on the overall XCu in the a-C:H:Cu coatings and that an additional a-C:H barrier layer on top of the a-C:H:Cu layer effectively delays the release of Cu ions.


  • Poster session 31: Modelling and simulation IV

    by Deusch Carolin, Olaf Specht, Heidi Fleischer, Ingolf Beutner, Mareike Warkentin

  • Kunststoffe: Von jedem benutzt – von wenigen gekannt

    by M. Warkentin, D Behrend

    Kunststoffe finden seit geraumer Zeit Anwendung in der Füllungstherapie und stellen durch ihre vielfältigen Anwendungsmöglichkeiten, bedingt durch die Matrix- und Füllstoffkonzepte, eine Alternative zum herkömmlichen Amalgam dar. Dennoch zeigen sie noch Optimierungsbedarf hinsichtlich ihrer mechanischen Eigenschaften, wie z. B. der Härte, die ein Indikator für die Abrasion ist. Darüber hinaus unterliegen sie im oralen Milieu einer Alterung. Neben einer langfristigen Verschlechterung der Materialeigenschaften, kommt es aber ab dem 1. Kontakt mit dem Speichel zum Herausdiffundieren von Matrixbestandteilen. Das allergene Potenzial dieser Materialien ist nachgewiesen, eine verlässliche Prognose möglicher langfristiger lokaler und/oder systemischer Effekte ist beim derzeitigen Stand der Literatur noch nicht möglich. Dennoch sollte bereits über alternative allergiefreie Werkstoffe nachgedacht werden. Erstveröffentlichung in umwelt•medizin•gesellschaft, Ausgabe 3/2015. Nachdruck mit freundlicher Genehmigung.

  • No influence of simultaneous bone-substitute application on the success of immediately loaded dental implants: a retrospective cohort study

    by Sigmar Kopp, Detlef Behrend, Günther Kundt, Peter Ottl, Bernhard Frerich, Mareike Warkentin

    To examine the influence of bone-substitute application during implantation on the success of immediately placed and loaded dental implants. A total of 147 consecutive patients (age, 16.5-80.4 years) were provided with 696 immediately loaded implants. The mean follow-up time was 34.1 months. Of these implants, 50.4% (n=351) were immediately placed into extraction sockets. A total of 119 implants were added by simultaneous bone-substitute application (NanoBone, Artoss GmbH, Rostock Germany), whereas the other implants were placed in healed bone. Univariate and multivariate analysis was performed using IBM SPSS V.20. The overall implant success rate was 96.1%. Implants with simultaneous bone replacement had a hazard ratio of 0.877 (p=0.837); 95% CI, 0.253-3.04). Factors found to be statistically significant modifiers of success on multivariate analysis (p<0.05) included type of superstructure (p<0.001), implant-abutment connection (p<0.001), membrane use (p=0.010), and jaw (p=0.026). None of the other factors investigated were significant modifiers. The present study demonstrates high success rates for immediately loaded implants and their superstructures independent of the simultaneous application of bone substitute. The declared aim of socket preservation, the prevention avoiding bone loss, is achieved in the immediate implant placement scenario under immediate-loading conditions.