SLSonia E. Létant

Sonia E. Létant

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sonia E. Létant has a total of 69 co-authors. Here are the top co-authors by number of shared publications:

  • E. Raber

    Lawrence Livermore National Laboratory, 7000 East Avenue (L-452), Livermore, CA 94550, United States

    2 shared publications
  • G.A. Murphy

    Lawrence Livermore National Laboratory, 7000 East Avenue (L-452), Livermore, CA 94550, United States

    2 shared publications
  • J. Nilsson

    Chemistry & Materials Science Directorate, Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94550, USA

    2 shared publications
  • Staci R. Kane

    Biosciences and Biotechnology Division, Physical and Life Sciences Directorate, Lawrence Livermore National Laboratory, Livermore, CA, USA

    2 shared publications
  • T. V. Ratto

    Chemistry & Materials Science Directorate, Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94550, USA

    2 shared publications
  • T.M. Alfaro

    Lawrence Livermore National Laboratory, 7000 East Avenue (L-452), Livermore, CA 94550, United States

    2 shared publications

Latest Publications

  • Rapid-Viability PCR Method for Detection of Live, Virulent Bacillus anthracis in Environmental Samples

    by Sonia E. Létant, Gloria A. Murphy, Teneile M. Alfaro, Julie R. Avila, Staci R. Kane, Ellen Raber, Thomas M. Bunt, Sanjiv R. Shah

    In the event of a biothreat agent release, hundreds of samples would need to be rapidly processed to characterize the extent of contamination and determine the efficacy of remediation activities. Current biological agent identification and viability determination methods are both labor- and time-intensive such that turnaround time for confirmed results is typically several days. In order to alleviate this issue, automated, high-throughput sample processing methods were developed in which real-time PCR analysis is conducted on samples before and after incubation. The method, referred to as rapid-viability (RV)-PCR, uses the change in cycle threshold after incubation to detect the presence of live organisms. In this article, we report a novel RV-PCR method for detection of live, virulent Bacillus anthracis , in which the incubation time was reduced from 14 h to 9 h, bringing the total turnaround time for results below 15 h. The method incorporates a magnetic bead-based DNA extraction and purification step prior to PCR analysis, as well as specific real-time PCR assays for the B. anthracis chromosome and pXO1 and pXO2 plasmids. A single laboratory verification of the optimized method applied to the detection of virulent B. anthracis in environmental samples was conducted and showed a detection level of 10 to 99 CFU/sample with both manual and automated RV-PCR methods in the presence of various challenges. Experiments exploring the relationship between the incubation time and the limit of detection suggest that the method could be further shortened by an additional 2 to 3 h for relatively clean samples.


  • Most-Probable-Number Rapid Viability PCR method to detect viable spores of Bacillus anthracis in swab samples

    by S.E. Létant, S.R. Kane, G.A. Murphy, T.M. Alfaro, L.R. Hodges, L.J. Rose, E. Raber


  • Rapid, high-throughput, culture-based PCR methods to analyze samples for viable spores of Bacillus anthracis and its surrogates

    by S.R. Kane, S.E. Létant, G.A. Murphy, T.M. Alfaro, P.W. Krauter, R. Mahnke, T.C. Legler, E. Raber


  • Efficient Nanoporous Silicon Membranes for Integrated Microfluidic Separation and Sensing Systems

    by Nazar Ileri, Sonia E. Létant, Jerald Britten, Hoang Nguyen, Cindy Larson, Saleem Zaidi, Ahmet Palazoglu, Roland Faller, Joseph W. Tringe, Pieter Stroeve


  • Ultra-fast Laser Synthesis of Nanopore Arrays in Silicon for Bio-molecule Separation and Detection

    by J W Tringe, N Ileri, S Letant, P Stroeve, M Shirk, S Zaidi, R L Balhorn, C W Siders

    We demonstrate that interference of ultra-fast pulses of laser light can create regular patterns in thin silicon membranes that are compatible with the formation of a uniform array of nanopores. The spacing and size of these pores can be tuned by changing the laser energy, wavelength and number of ultra-short pulses. Short pulses and wavelengths ({approx}550 nm and smaller) are needed to define controllable nanoscale features in silicon. Energy must be localized in time and space to produce the etching, ablation or amorphization effects over the {approx}100 nm length scales appropriate for definition of single pores. Although in this brief study pattern uniformity was limited by laser beam quality, a complementary demonstration reported here used continuous-wave interferometric laser exposure of photoresist to show the promise of the ultra-fast approach for producing uniform pore arrays. The diameters of these interferometrically-defined features are significantly more uniform than the diameters of pores in state-of-the-art polycarbonate track etch membranes widely used for molecular separations.

  • A Multiplexed Diagnostic Platform for Point-of-Care Pathogen Detection

    by J F Regan, S Letant, K L Adams, R C Mahnke, N T Nguyen, J M Dzenitis, B J Hindson, D R Hadley, T J Makarewicz, B D Henderer, et al.

    We developed an automated point-of-care diagnostic instrument that is capable of analyzing nasal swab samples for the presence of respiratory diseases. This robust instrument, called FluIDx, performs autonomous multiplexed RT-PCR reactions that are analyzed by microsphere xMAP technology. We evaluated the performance of FluIDx, in comparison rapid tests specific for influenza and respiratory syncytial virus, in a clinical study performed at the UC Davis Medical Center. The clinical study included samples positive for RSV (n = 71), influenza A (n = 16), influenza B (n = 4), adenovirus (n = 5), parainfluenza virus (n = 2), and 44 negative samples, according to a composite reference method. FluIDx and the rapid tests detected 85.9% and 62.0% of the RSV positive samples, respectively. Similar sensitivities were recorded for the influenza B samples; whereas the influenza A samples were poorly detected, likely due to the utilization of an influenza A signature that did not accurately match currently circulating influenza A strains. Data for all pathogens were compiled and indicate that FluIDx is more sensitive than the rapid tests, detecting 74.2% (95% C.I. of 64.7-81.9%) of the positive samples in comparison to 53.6% (95% C.I. of 43.7-63.2%) for the rapid tests. The higher sensitivitymore » of FluIDx was partially offset by a lower specificity, 77.3% versus 100.0%. Overall, these data suggest automated flow-through PCR-based instruments that perform multiplexed assays can successfully screen clinical samples for infectious diseases.« less

  • Multiplexed Reverse Transcriptase PCR Assay for Identification of Viral Respiratory Pathogens at the Point of Care

    by Sonia E. Létant, Josue I. Ortiz, Lance F. Bentley Tammero, James M. Birch, Robert W. Derlet, Stuart Cohen, Dannelle Manning, Mary T. McBride

    We have developed a nucleic acid-based assay that is rapid, sensitive, and specific and can be used for the simultaneous detection of five common human respiratory pathogens, including influenza virus A, influenza virus B, parainfluenza virus types 1 and 3, respiratory syncytial virus (RSV), and adenovirus groups B, C, and E. Typically, diagnosis on an unextracted clinical sample can be provided in less than 3 h, including sample collection, preparation, and processing, as well as data analysis. Such a multiplexed panel would enable rapid broad-spectrum pathogen testing on nasal swabs and therefore allow implementation of infection control measures and the timely administration of antiviral therapies. We present here a summary of the assay performance in terms of sensitivity and specificity. The limits of detection are provided for each targeted respiratory pathogen, and result comparisons were performed on clinical samples, our goal being to compare the sensitivity and specificity of the multiplexed assay to the combination of immunofluorescence and shell vial culture currently implemented at the University of California-Davis Medical Center hospital. Overall, the use of the multiplexed reverse transcription-PCR assay reduced the rate of false-negative results by 4% and reduced the rate of false-positive results by up to 10%. The assay correctly identified 99.3% of the clinical negatives and 97% of the adenovirus, 95% of the RSV, 92% of the influenza virus B, and 77% of the influenza virus A samples without any extraction performed on the clinical samples. The data also showed that extraction will be needed for parainfluenza virus, which was only identified correctly 24% of the time on unextracted samples.


  • Semiconductor Quantum Dot Scintillation under γ-Ray Irradiation

    by S. E. Létant, T.-F. Wang

    We recently demonstrated the ability of semiconductor quantum dots to convert α radiation into visible photons. In this letter, we report on the scintillation of quantum dots under γ irradiation and compare the energy resolution of the 59 keV line of americium-241 obtained with our quantum dot−glass nanocomposite to that of a standard sodium iodide scintillator. A factor 2 improvement is demonstrated experimentally and interpreted theoretically using a combination of energy-loss and photon-transport models.


  • Pore Conductivity Control at the Hundred‐Nanometer Scale: An Experimental and Theoretical Study

    by Sonia E. Létant, Charlene M. Schaldach, Mackenzie R. Johnson, April Sawvel, William L. Bourcier, William D. Wilson

    We report on the observation of an unexpected mechanism that controls conductivity at the 100-nm scale on track-etched polycarbonate membranes. Transport measurements of positively charged methyl viologen performed by absorption spectroscopy under various pH conditions demonstrate that for 100-nm-diameter pores at pH 2 conductivity is blocked, while at pH 5 the ions move through the membrane according to diffusion laws. An oppositely charged molecular ion, naphthalene disulfonate, in the same membrane, shows the opposite trend: diffusion of the negative ion at pH 2 and very low conductivity at pH 5. The influence of parameters such as ionic strength and membrane surface coating are also investigated. A theoretical study of the system shows that at the 100-nm scale the magnitude of the electric field in the vicinity of the pores is too small to account for the experimental observations; rather, it is the surface trapping of the mobile ion (Cl− or Na+) that gives rise to the observed control of the conductivity. This surprising effect has potential applications for high-throughput separation of large molecules and bio-organisms.


  • Cover Picture: Localized Functionalization of Single Nanopores (Adv. Mater. 4/2006)

    by J. Nilsson, J. R. I. Lee, T. V. Ratto, S. E. Létant

    Single nanopores can be fabricated using a combination of focused‐ion‐beam drilling and local ion‐beam‐assisted oxide deposition. On p. 427, Letant and co‐workers show how a silicon oxide ring can be grown around a single nanopore and how it can be functionalized with single‐stranded DNA using thiol‐terminated linkers. Current–voltage measurements demonstrate the presence of DNA on the pore wall and the open nature of the pore. Future applications include specific detection of whole organisms, ranging in size from bacteria to viruses.