KOKent M. Ogden

Kent M. Ogden

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kent M. Ogden has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Walter Huda

    Department of Radiology and Radiological Science, Medical University of South Carolina (MUSC), Charleston, SC, USA

    3 shared publications
  • Ernest M. Scalzetti

    Department of Radiology, SUNY Upstate Medical University, Syracuse, USA

    2 shared publications
  • Marsha L. Roskopf

    Department of Radiology, SUNY Upstate Medical University, Syracuse, USA

    2 shared publications
  • Robert L. Lavallee

    Department of Radiology, SUNY Upstate Medical University, Syracuse, USA

    2 shared publications
  • Can Aslan

    Department of Biomedical and Chemical Engineering, Syracuse University, 900 S Crouse Ave, Syracuse, NY, 13210, USA

    1 shared publication
  • Dalanda Diallo

    Department of Radiology, University of South Florida, 4202 E. Fowler Avenue, Tampa, FL, 33620, USA

    1 shared publication

Latest Publications

  • Open Access

    3D printed testing aids for radiographic quality control

    by Kent M. Ogden, Kristin E. Morabito, Paul K. Depew

    Quality control testing of radiographic and fluoroscopic imaging systems requires positioning of test objects in the x‐ray beam in a precise and repeatable fashion. In this work we present several three‐dimensional (3D) printed testing aids that improve efficiency, accuracy, and repeatability of quality control testing. We also present a new device for determining the location of the perpendicular ray in radiographic systems. These devices were designed in an open source software program (OpenScad, http://www.openscad.org) and 3D models were saved in .stl format for printing. The models were printed on either a MakerBot Replicator 2 or Replicator Z18 printer (MakerBot Industries, LLC, Brooklyn, NY). The testing aids were printed using polylactic acid (PLA) filament. To investigate the radiographic characteristics of the PLA used, test articles were printed and used to measure the half‐value layer (HVL) thicknesses in mm of PLA and half‐value densities (HVD) in g/cm2 of PLA for two different colors and over a wide range of radiographic beam qualities, using a portable fluoroscopic c‐arm system. HVL thicknesses of clear PLA ranged from approximately 20 mm at 50 kV nominal tube voltage to 27 mm at 120 kV nominal tube voltage. For green PLA, the HVL thickness was 19 mm at 50 kV tube voltage and 25.7 mm at 120 kV tube voltage. The HVD of clear PLA ranged from 2.37 g/cm2 at 50 kV nominal tube voltage to 3.19 g/cm2 at 120 kV nominal tube voltage. For green PLA, the HVD was 2.35 g/cm2 at 50 kV tube voltage and 3.17 g/cm2 at 120 kV tube voltage. The cost of the devices range from under $2 to approximately $20 in materials. The files used to create the models are freely available at https://github.com/Upstate3DLab/3D-Printed-Radiographic-Test-Tools.


  • Open Access

    Factors Affecting Dimensional Accuracy of 3-D Printed Anatomical Structures Derived from CT Data

    by Kent M. Ogden, Can Aslan, Nathaniel Ordway, Dalanda Diallo, Gwen Tillapaugh-Fay, Pranav Soman

    Additive manufacturing and bio-printing, with the potential for direct fabrication of complex patient-specific anatomies derived from medical scan data, are having an ever-increasing impact on the practice of medicine. Anatomic structures are typically derived from CT or MRI scans, and there are multiple steps in the model derivation process that influence the geometric accuracy of the printed constructs. In this work, we compare the dimensional accuracy of 3-D printed constructs of an L1 vertebra derived from CT data for an ex vivo cadaver T-L spine with the original vertebra. Processing of segmented structures using binary median filters and various surface extraction algorithms is evaluated for the effect on model dimensions. We investigate the effects of changing CT reconstruction kernels by scanning simple geometric objects and measuring the impact on the derived model dimensions. We also investigate if there are significant differences between physical and virtual model measurements. The 3-D models were printed using a commercial 3-D printer, the Replicator 2 (MakerBot, Brooklyn, NY) using polylactic acid (PLA) filament. We found that changing parameters during the scan reconstruction, segmentation, filtering, and surface extraction steps will have an effect on the dimensions of the final model. These effects need to be quantified for specific situations that rely on the accuracy of 3-D printed models used in medicine or tissue engineering applications.


  • KERMA ratios in pediatric CT dosimetry

    by Walter Huda, Kent M. Ogden, Robert L. Lavallee, Marsha L. Roskopf, Ernest M. Scalzetti

    Background Patient organ doses may be estimated from CTDI values. More accurate estimates may be obtained by measuring KERMA (Kinetic Energy Released in Matter) in anthropomorphic phantoms and referencing these values to free-in-air X-ray intensity. Objective To measure KERMA ratios (RK) in pediatric phantoms at CT. Materials & methods CT scans produce an air KERMA K in a phantom and an air KERMA KCT at isocenter. KERMA ratios (RK) are defined as (K/KCT), measured using TLD chips in phantoms representing newborns to 10-year-olds. Results RK in the newborn is approximately constant. For the other phantoms, there is a peak RK value in the neck. The median RK values for the GE scanner at 120 kV were 0.92, 0.83, 0.77 and 0.76 for newborns, 1-year-olds, 5-year-olds and 10-year-olds, respectively. Organ RK values were 0.91 ± 0.04, 0.84 ± 0.07, 0.74 ± 0.09 and 0.72 ± 0.10 in newborns, 1-year-olds, 5-year-olds and 10-year-olds, respectively. At 120 kV, a Siemens Sensation 16 scanner had RK values 5% higher than those of the GE LightSpeed Ultra. Conclusion KERMA ratios may be combined with air KERMA measurements at the isocenter to estimate organ doses in pediatric CT patients.


  • In-patient to isocenter KERMA ratios in CT

    by Walter Huda, Kent M. Ogden, Robert L. Lavallee, Marsha L. Roskopf, Ernest M. Scalzetti

    Purpose: To estimate in-patient KERMA for specific organs in computed tomography(CT) scanning using ratios to isocenter free-in-air KERMA obtained using a Rando phantom. Method: A CT scan of an anthropomorphic phantom results in an air KERMA K at a selected phantom location and air kerma KCT at the CTscanner isocenter when the scan is repeated in the absence of the phantom. The authors define the KERMA ratio (RK) as K/ KCT, which were experimentally determined in a Male Rando Phantom using lithium fluoride chips (TLD-100). RK values were obtained for a total of 400 individual point locations, as well as for 25 individual organs of interest in CTdosimetry.CT examinations of Rando were performed on a GE LightSpeed Ultra scanner operated at 80 kV, 120 kV, and 140 kV, as well as a Siemens Sensation 16 operated at 120 kV. Results: At 120 kV, median RK values for the GE and Siemens scanners were 0.60 and 0.64, respectively. The 10th percentile RK values ranged from 0.34 at 80 kV to 0.54 at 140 kV, and the 90th percentile RK values ranged from 0.64 at 80 kV to 0.78 at 140 kV. The average RK for the 25 Rando organs at 120 kV was 0.61 ± 0.08. Average RK values in the head, chest, and abdomen showed little variation. Relative to RK values in the head, chest, and abdomen obtained at 120 kV, RK values were about 12% lower in the pelvis and about 58% higher in the cervical spine region. Average RK values were about 6% higher on the Siemens Sensation 16 scanner than the GE LightSpeed Ultra. Reducing the x-ray tube voltage from 120 kV to 80 kV resulted in an average reduction in RK value of 34%, whereas increasing the x-ray tube voltage to 140 kV increased the average RK value by 9%. Conclusions: In-patient to isocenter relative KERMA values in Rando phantom can be used to estimate organdoses in similar sized adults undergoing CT examinations from easily measured air KERMA values at the isocenter (free in air). Conversion from in-patient air KERMA values to tissuedose would require the use of energy-appropriate conversion factors.


  • The effect of dose reductions on lesion detection in head CT

    by Saeed Elojeimy, Walter Huda, Kent M. Ogden, Ryan Owen, Ehsan Samei, Zoran Rumboldt

    The purpose of this study was to quantitatively evaluate the effect of reducing radiation dose (i.e., mAs) on lesion detection in head CT examinations. We used a simulation package (Syngo Explorer) to reconstruct 5-mm thick CT images of the brain of one patient pertaining to the centrum semiovale, the basal ganglia, and the sella turcica. Lesion detection was measured using two Alternate Forced Choice (2-AFC) experiments that measure the lesion contrast (I92%) corresponding to a detection accuracy of 92%. Two observers performed experiments to investigate detection of low contrast lesions with four sizes ranging from 3 mm to 10 mm and at four x-ray beam intensities ranging from 105 mAs to 300 mAs. Results were plotted as log[I92%] versus log[mAs], and the slopes were measured for each lesion size. Lowering the mAs always reduced lesion detection performance in all images, and for all lesion sizes. Average slopes of the I92% versus mAs curves were -0.23 for 3 mm lesions, -0.16 for 4.5 mm lesions, and ~-0.11 for the 7 and 10 mm lesions. For the smallest lesions investigated (3 mm), doubling the x-ray intensity improved lesion detection performance by ~ 15%, whereas for the largest sized lesions (7 and 10 mm), doubling the tube current improved lesion detection performance by ~ 7%. The observed improvements in detection performance are markedly lower than predicted by the Rose model where a doubling of the tube current would be expected to improve detection performance by 29% at all lesion sizes.


  • Computing effective doses to pediatric patients undergoing body CT examinations

    by Walter Huda, Kent M. Ogden

    Background The computation of patient effective doses to children is of particular interest given the relatively high doses received from this imaging modality, as well as the increased utilization of CT in all areas of medicine. Current methods for computing effective doses to children are relatively complex, and it would be useful to develop a simple method of computing pediatric effective doses for clinical purposes that could be used by radiologists and technologists. Objective To obtain pediatric effective doses for body CT examinations by the use of adult effective doses obtained from effective dose (E) per unit dose length product (DLP) coefficients, and energy imparted to a child relative to an adult. Materials and methods Adult E/DLP coefficients were obtained at 120 kV using the ImPACT CT dosimetry spreadsheet. Patients were modeled as cylinders of water, and values of energy imparted to cylinders of varying radii were generated using Monte Carlo modeling. The amounts of energy imparted to the chest and abdomen of children relative to adults (Ren) were obtained. Pediatric effective doses were obtained using scaling factors that accounted for scan length, mAs, patient weight, and relative energy imparted (Ren). Results E/DLP values were about 16 μSv/mGy cm for males and about 19 μSv/mGy cm for females. Ren at 120 kV for newborns was 0.35 for the chest and 0.49 for the abdomen. At constant mAs, the effective dose to 6-month-old patients undergoing chest CT examinations was found to be about 50% higher than that to adults, and for abdominal examinations about 100% higher. Conclusion Adult effective doses can be obtained using DLP data and can be scaled to provide corresponding pediatric effective doses from body examinations on the same CT scanner.