Vishal Patil
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Vishal Patil has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Glyn Johnson
University of East Anglia
4 shared publications - Jens H. Jensen
Center for Biomedical Imaging Medical University of South Carolina Charleston South Carolina USA
2 shared publications
Latest Publications
- 6 December 2012
- Published by Wiley in NMR in Biomedicine
- Vol. 26 (4) , 392-399
Intravascular contrast agent T2* relaxivity in brain tissue
Dynamic susceptibility‐weighted contrast‐enhanced (DSC) MRI perfusion measurements depend on estimating intravascular contrast agent (CA) concentrations (C) from signal intensity changes in ‐weighted images after bolus injection. Generally, linearity is assumed between relaxation and C, but previous studies have shown that compartmentalization of CA and secondary magnetic field perturbations generate deviations from linearity. Physical phantoms using bulk blood have been used to empirically determine the relationship between relaxation rate and C in large vessels. However, the relaxivity of CA in the microvasculature is not easily measured since constructing appropriate phantoms is difficult. Instead, theoretical relaxivity models have been developed. In this study, we empirically tested a non‐linear expression based on static dephasing regime (SDR) and linear approximation. Signal‐time curves in white (WM) and grey matter (GM) were converted to concentration time curves (CTCs) using both expressions. Parameters for both linear and non‐linear formulations were adjusted to give a best agreement between cerebral blood volumes (CBV) calculated from WM and arterial CTCs in a group of normal subjects scanned at 3T. Optimized parameters were used to calculate blood volume in WM and GM in healthy subjects scanned at 3T and in meningioma patients scanned at 1.5T. Results from this study showed that a non‐linear SDR formulation gave an acceptable functional form for tissue relaxivity, giving reliable CBV estimates at different field strengths and echo times. Copyright © 2012 John Wiley & Sons, Ltd.
- 6 December 2012
- Published by Wiley in NMR in Biomedicine
- Vol. 26 (4) , 392-399
Intravascular contrast agent T2* relaxivity in brain tissue
Dynamic susceptibility‐weighted contrast‐enhanced (DSC) MRI perfusion measurements depend on estimating intravascular contrast agent (CA) concentrations (C) from signal intensity changes in ‐weighted images after bolus injection. Generally, linearity is assumed between relaxation and C, but previous studies have shown that compartmentalization of CA and secondary magnetic field perturbations generate deviations from linearity. Physical phantoms using bulk blood have been used to empirically determine the relationship between relaxation rate and C in large vessels. However, the relaxivity of CA in the microvasculature is not easily measured since constructing appropriate phantoms is difficult. Instead, theoretical relaxivity models have been developed. In this study, we empirically tested a non‐linear expression based on static dephasing regime (SDR) and linear approximation. Signal‐time curves in white (WM) and grey matter (GM) were converted to concentration time curves (CTCs) using both expressions. Parameters for both linear and non‐linear formulations were adjusted to give a best agreement between cerebral blood volumes (CBV) calculated from WM and arterial CTCs in a group of normal subjects scanned at 3T. Optimized parameters were used to calculate blood volume in WM and GM in healthy subjects scanned at 3T and in meningioma patients scanned at 1.5T. Results from this study showed that a non‐linear SDR formulation gave an acceptable functional form for tissue relaxivity, giving reliable CBV estimates at different field strengths and echo times. Copyright © 2012 John Wiley & Sons, Ltd.
- Open Access
- 10 May 2012
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 69 (4) , 1104-1108
ΔR2* gadolinium‐diethylenetriaminepentacetic acid relaxivity in venous blood
The accuracy of perfusion measurements using dynamic, susceptibility‐weighted, contrast‐enhanced MRI depends on estimating contrast agent concentration in an artery, i.e., the arterial input function. One of the difficulties associated with obtaining an arterial input function are partial volume effects when both blood and brain parenchyma occupy the same pixel. Previous studies have attempted to correct arterial input functions which suffer from partial volume effects using contrast concentration in venous blood. However, the relationship between relaxation and concentration (C) in venous blood has not been determined in vivo. In this note, a previously employed fitting approach is used to determine venous relaxivity in vivo. In vivo relaxivity is compared with venous relaxivity measured in vitro in bulk blood. The results show that the fitting approach produces relaxivity calibration curves which give excellent agreement with arterial measurements. Magn Reson Med 69:1104–1108, 2013.
- 10 May 2012
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 69 (4) , 1104-1108
Open AccessΔR2* gadolinium‐diethylenetriaminepentacetic acid relaxivity in venous blood
The accuracy of perfusion measurements using dynamic, susceptibility‐weighted, contrast‐enhanced MRI depends on estimating contrast agent concentration in an artery, i.e., the arterial input function. One of the difficulties associated with obtaining an arterial input function are partial volume effects when both blood and brain parenchyma occupy the same pixel. Previous studies have attempted to correct arterial input functions which suffer from partial volume effects using contrast concentration in venous blood. However, the relationship between relaxation and concentration (C) in venous blood has not been determined in vivo. In this note, a previously employed fitting approach is used to determine venous relaxivity in vivo. In vivo relaxivity is compared with venous relaxivity measured in vitro in bulk blood. The results show that the fitting approach produces relaxivity calibration curves which give excellent agreement with arterial measurements. Magn Reson Med 69:1104–1108, 2013.
- 9 November 2011
- Published by Wiley in Medical Physics
- Vol. 38 (12) , 6380-6383
An improved model for describing the contrast bolus in perfusion MRI
Purpose: Quantification of perfusion measurements using dynamic, susceptibility‐weighted contrast‐enhanced (DSC) MRI depends on estimating the size and shape of the tracer bolus. Typically, the bolus is described as a gamma variate function (GV) fitted to the bolus portion of tracer concentration time curve (CTC). However, the last point to fit is arbitrary which can lead to considerable variation in the fitted curve in the presence of noise. In this technical note, we present a model which takes into account recirculation explicitly and fits robustly to the entire CTC in the presence of noise.Methods: Signal data measurements from ten DSC MRI patients were fitted with our new model and a GV function using four different methods of estimating the end of the bolus. Estimates of the area under the curves (AUC) and first moments (FMs) of the bolus were compared at different noise levels.Results: The new model gave errors similar to or smaller than those of the most effective methods for fitting a GV.Conclusions: The single compartment recirculation (SCR) model is the most robust fitting technique with respect to noise both for bias and variability.
- 9 November 2011
- Published by Wiley in Medical Physics
- Vol. 38 (12) , 6380-6383
An improved model for describing the contrast bolus in perfusion MRI
Purpose: Quantification of perfusion measurements using dynamic, susceptibility‐weighted contrast‐enhanced (DSC) MRI depends on estimating the size and shape of the tracer bolus. Typically, the bolus is described as a gamma variate function (GV) fitted to the bolus portion of tracer concentration time curve (CTC). However, the last point to fit is arbitrary which can lead to considerable variation in the fitted curve in the presence of noise. In this technical note, we present a model which takes into account recirculation explicitly and fits robustly to the entire CTC in the presence of noise.Methods: Signal data measurements from ten DSC MRI patients were fitted with our new model and a GV function using four different methods of estimating the end of the bolus. Estimates of the area under the curves (AUC) and first moments (FMs) of the bolus were compared at different noise levels.Results: The new model gave errors similar to or smaller than those of the most effective methods for fitting a GV.Conclusions: The single compartment recirculation (SCR) model is the most robust fitting technique with respect to noise both for bias and variability.
- Open Access
- 11 August 2009
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 62 (4) , 1002-1006
Robust quantification of contrast agent (CA) concentration with magnetic field correlation (MFC) imaging
Contrast‐enhanced perfusion studies of the brain by means magnetic resonance imaging (MRI) are used to estimate a number of important brain tissue parameters, including cerebral blood flow and volume. In order to calculate these parameters, the contrast agent (CA) concentration must first be estimated. This is usually accomplished by measurement of a nuclear magnetic resonance (NMR) relaxation rate with the assumption of a linear relationship between the rate and the CA concentration. However, such a linear relationship does not necessarily hold in biological tissues due to compartmentalization of the CA in either the intravascular or extracellular spaces. Here we propose an alternative MRI method of CA quantification based on measurement of the magnetic field correlation (MFC), which is theoretically predicted to have a robust quadratic dependence on the CA concentration even when the CA is compartmentalized. In this study, CA concentration estimation by means of MFC is shown to be more accurate than established methods based on relaxation rates in yeast cell suspensions. Magn Reson Med, 2009.
- 11 August 2009
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 62 (4) , 1002-1006
Open AccessRobust quantification of contrast agent (CA) concentration with magnetic field correlation (MFC) imaging
Contrast‐enhanced perfusion studies of the brain by means magnetic resonance imaging (MRI) are used to estimate a number of important brain tissue parameters, including cerebral blood flow and volume. In order to calculate these parameters, the contrast agent (CA) concentration must first be estimated. This is usually accomplished by measurement of a nuclear magnetic resonance (NMR) relaxation rate with the assumption of a linear relationship between the rate and the CA concentration. However, such a linear relationship does not necessarily hold in biological tissues due to compartmentalization of the CA in either the intravascular or extracellular spaces. Here we propose an alternative MRI method of CA quantification based on measurement of the magnetic field correlation (MFC), which is theoretically predicted to have a robust quadratic dependence on the CA concentration even when the CA is compartmentalized. In this study, CA concentration estimation by means of MFC is shown to be more accurate than established methods based on relaxation rates in yeast cell suspensions. Magn Reson Med, 2009.