Weiliang Du
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Weiliang Du has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Rajat J. Kudchadker
Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
3 shared publicationsSong Gao
Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
3 shared publicationsDershan Luo
Departments of Radiation Physics The University of Texas M. D. Anderson Cancer Center Houston TX USA
2 shared publicationsJames Yang
Department of Radiation Physics, The University of Texas M. D. Anderson Cancer Center, Houston, Texas 77030
2 shared publicationsWei Jiang
Yantai Yuhuangding Hospital, Qingdao University School of Medicine, Yantai, Shandong, China
2 shared publicationsAlmon Shiu
Departments of Radiation Physics The University of Texas M. D. Anderson Cancer Center Houston TX USA
1 shared publication
Latest Publications
- Open Access
- 4 February 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (4) , e70000
High‐precision localization of radiation isocenter using Winston‐Lutz test: Impact of collimator angle, phantom position, and field size
Purpose: This study aimed to evaluate the impact of collimator angle, ball bearing (BB) phantom position, and field size on the accuracy of Winston‐Lutz (WL) test–derived radiation isocenters.Methods: WL tests were performed on four TrueBeam linear accelerators. Fifty‐six images (eight gantry angles multiplied by seven collimator angles) were acquired for each WL test. Images with different sets of collimator angles were used to compute the radiation isocenters. The resulting radiation isocenters were correlated with the collimator angles. Then, the BB position and radiation field size were varied for the subsequent WL tests. The calculated BB shifts were compared with the known shifts, and the radiation isocenters were compared between different field sizes.Results: The use of a single collimator angle led to errors of as much as 0.4 mm in the calculated radiation isocenters. Systematic differences were observed between the radiation isocenters derived with collimator angle 0° and those derived with 90° and/or 270°. A commonly used opposing collimator angle pair, 90° and 270°, resulted in a vertical 0.1 mm offset of the radiation isocenters toward the ceiling. Oblique opposite or mixed collimator angles yielded radiation isocenter errors less than 0.1 mm. The BB shifts derived from WL tests were less than 0.1 mm from the known shifts. The radiation isocenters varied by less than 0.1 mm between field sizes ranging from 2 × 2 cm2 to 20 × 20 cm2.Conclusions: Oblique opposing collimator angle pairs should be considered to minimize errors in localizing radiation isocenters. Uncertainty in BB positioning could be eliminated if the BB is used as a static reference point in space. The field size had no significant effect on the radiation isocenters. With careful design of WL test parameters and image processing, it is possible to achieve a precision of 0.1 mm in localizing radiation isocenters using WL tests.
- 4 February 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (4) , e70000
Open AccessHigh‐precision localization of radiation isocenter using Winston‐Lutz test: Impact of collimator angle, phantom position, and field size
Purpose: This study aimed to evaluate the impact of collimator angle, ball bearing (BB) phantom position, and field size on the accuracy of Winston‐Lutz (WL) test–derived radiation isocenters.Methods: WL tests were performed on four TrueBeam linear accelerators. Fifty‐six images (eight gantry angles multiplied by seven collimator angles) were acquired for each WL test. Images with different sets of collimator angles were used to compute the radiation isocenters. The resulting radiation isocenters were correlated with the collimator angles. Then, the BB position and radiation field size were varied for the subsequent WL tests. The calculated BB shifts were compared with the known shifts, and the radiation isocenters were compared between different field sizes.Results: The use of a single collimator angle led to errors of as much as 0.4 mm in the calculated radiation isocenters. Systematic differences were observed between the radiation isocenters derived with collimator angle 0° and those derived with 90° and/or 270°. A commonly used opposing collimator angle pair, 90° and 270°, resulted in a vertical 0.1 mm offset of the radiation isocenters toward the ceiling. Oblique opposite or mixed collimator angles yielded radiation isocenter errors less than 0.1 mm. The BB shifts derived from WL tests were less than 0.1 mm from the known shifts. The radiation isocenters varied by less than 0.1 mm between field sizes ranging from 2 × 2 cm2 to 20 × 20 cm2.Conclusions: Oblique opposing collimator angle pairs should be considered to minimize errors in localizing radiation isocenters. Uncertainty in BB positioning could be eliminated if the BB is used as a static reference point in space. The field size had no significant effect on the radiation isocenters. With careful design of WL test parameters and image processing, it is possible to achieve a precision of 0.1 mm in localizing radiation isocenters using WL tests.
- Open Access
- 29 June 2018
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 19 (5) , 483-490
Independent evaluation of the effectiveness of IsoCal in improving image center accuracy on Varian TrueBeam and Clinac machines
Modern medical linear accelerators (linacs) are often equipped with image guidance systems that are capable of megavolt (MV), kilovolt (kV), planar, or volumetric imaging. On Varian TrueBeam linacs, the isocenter accuracies of the imaging systems are calibrated with a procedure named IsoCal. On Clinac series linacs from Varian, installation of IsoCal is optional and the effects of IsoCal on the imaging systems can be turned on or off after the IsoCal procedure is performed. In this study, we report on the effectiveness of IsoCal in improving the coincidence of the image centers with the radiation isocenter, using an independent Winston‐Lutz (WL) method to locate the radiation isocenter. A ball‐bearing phantom was imaged with 2D MV, 2D kV, and cone beam computed radiography systems on two TrueBeam and two Clinac machines. Using the same phantom, digital WL tests with 16 combinations of gantry and collimator angles were performed to locate the radiation isocenter. The offsets between the IsoCal‐calibrated image centers and the WL radiation isocenter were found to be within 0.4 mm on the four linacs in this study. When IsoCal was turned off, the maximal offsets of the image centers were greater than 1.0 mm on the two Clinac machines. The method developed in this study can be used as a vendor‐independent quality assurance tool to assess the isocentricity of the image centers and radiation central axes.
- 29 June 2018
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 19 (5) , 483-490
Open AccessIndependent evaluation of the effectiveness of IsoCal in improving image center accuracy on Varian TrueBeam and Clinac machines
Modern medical linear accelerators (linacs) are often equipped with image guidance systems that are capable of megavolt (MV), kilovolt (kV), planar, or volumetric imaging. On Varian TrueBeam linacs, the isocenter accuracies of the imaging systems are calibrated with a procedure named IsoCal. On Clinac series linacs from Varian, installation of IsoCal is optional and the effects of IsoCal on the imaging systems can be turned on or off after the IsoCal procedure is performed. In this study, we report on the effectiveness of IsoCal in improving the coincidence of the image centers with the radiation isocenter, using an independent Winston‐Lutz (WL) method to locate the radiation isocenter. A ball‐bearing phantom was imaged with 2D MV, 2D kV, and cone beam computed radiography systems on two TrueBeam and two Clinac machines. Using the same phantom, digital WL tests with 16 combinations of gantry and collimator angles were performed to locate the radiation isocenter. The offsets between the IsoCal‐calibrated image centers and the WL radiation isocenter were found to be within 0.4 mm on the four linacs in this study. When IsoCal was turned off, the maximal offsets of the image centers were greater than 1.0 mm on the two Clinac machines. The method developed in this study can be used as a vendor‐independent quality assurance tool to assess the isocentricity of the image centers and radiation central axes.
- Open Access
- 8 January 2016
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 17 (1) , 167-178
On the selection of gantry and collimator angles for isocenter localization using Winston‐Lutz tests
In Winston‐Lutz (WL) tests, the isocenter of a linear accelerator (linac) is determined as the intersection of radiation central axes (CAX) from multiple gantry, collimator, and couch angles. It is well known that the CAX can wobble due to mechanical imperfections of the linac. Previous studies suggested that the wobble varies with gantry and collimator angles. Therefore, the isocenter determined in the WL tests has a profound dependence on the gantry and collimator angles at which CAX are sampled. In this study, we evaluated the systematic and random errors in the isocenters determined with different CAX sampling schemes. Digital WL tests were performed on six linacs. For each WL test, 63 CAX were sampled at nine gantry angles and seven collimator angles. Subsets of these data were used to simulate the effects of various CAX sampling schemes. An isocenter was calculated from each subset of CAX and compared against the reference isocenter, which was calculated from 48 opposing CAX. The differences between the calculated isocenters and the reference isocenters ranged from 0 to 0.8 mm. The differences diminished to less than 0.2 mm when 24 or more CAX were sampled. Isocenters determined with collimator 0° were vertically lower than those determined with collimator 90° and 270°. Isocenter localization errors in the longitudinal direction (along the axis of gantry rotation) showed a strong dependence on the collimator angle selected. The errors in all directions were significantly reduced when opposing collimator angles and opposing gantry angles were employed. The isocenter localization errors were less than 0.2 mm with the common CAX sampling scheme, which used four cardinal gantry angles and two opposing collimator angles. Reproducibility studies on one linac showed that the mean and maximum variations of CAX during the WL tests were 0.053 mm and 0.30 mm, respectively. The maximal variation in the resulting isocenters was 0.068 mm if 48 CAX were used, or 0.13 mm if four CAX were used. Quantitative results from this study are useful for understanding and minimizing the isocenter uncertainty in WL tests.PACS number: 87.56.Fc
- 8 January 2016
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 17 (1) , 167-178
Open AccessOn the selection of gantry and collimator angles for isocenter localization using Winston‐Lutz tests
In Winston‐Lutz (WL) tests, the isocenter of a linear accelerator (linac) is determined as the intersection of radiation central axes (CAX) from multiple gantry, collimator, and couch angles. It is well known that the CAX can wobble due to mechanical imperfections of the linac. Previous studies suggested that the wobble varies with gantry and collimator angles. Therefore, the isocenter determined in the WL tests has a profound dependence on the gantry and collimator angles at which CAX are sampled. In this study, we evaluated the systematic and random errors in the isocenters determined with different CAX sampling schemes. Digital WL tests were performed on six linacs. For each WL test, 63 CAX were sampled at nine gantry angles and seven collimator angles. Subsets of these data were used to simulate the effects of various CAX sampling schemes. An isocenter was calculated from each subset of CAX and compared against the reference isocenter, which was calculated from 48 opposing CAX. The differences between the calculated isocenters and the reference isocenters ranged from 0 to 0.8 mm. The differences diminished to less than 0.2 mm when 24 or more CAX were sampled. Isocenters determined with collimator 0° were vertically lower than those determined with collimator 90° and 270°. Isocenter localization errors in the longitudinal direction (along the axis of gantry rotation) showed a strong dependence on the collimator angle selected. The errors in all directions were significantly reduced when opposing collimator angles and opposing gantry angles were employed. The isocenter localization errors were less than 0.2 mm with the common CAX sampling scheme, which used four cardinal gantry angles and two opposing collimator angles. Reproducibility studies on one linac showed that the mean and maximum variations of CAX during the WL tests were 0.053 mm and 0.30 mm, respectively. The maximal variation in the resulting isocenters was 0.068 mm if 48 CAX were used, or 0.13 mm if four CAX were used. Quantitative results from this study are useful for understanding and minimizing the isocenter uncertainty in WL tests.PACS number: 87.56.Fc
- 28 March 2012
- Published by Wiley in Medical Physics
- Vol. 39 (4) , 2156-2162
Quantifying the gantry sag on linear accelerators and introducing an MLC‐based compensation strategy
Purpose:: Gantry sag is one of the well‐known sources of mechanical imperfections that compromise the spatial accuracy of radiation dose delivery. The objectives of this study were to quantify the gantry sag on multiple linear accelerators (linacs), to investigate a multileaf collimator (MLC)‐based strategy to compensate for gantry sag, and to verify the gantry sag and its compensation with film measurements.Methods:: The authors used the Winston–Lutz method to measure gantry sag on three Varian linacs. A ball bearing phantom was imaged with megavolt radiation fields at 10° gantry angle intervals. The images recorded with an electronic portal imaging device were analyzed to derive the radiation isocenter and the gantry sag, that is, the superior–inferior wobble of the radiation field center, as a function of the gantry angle. The authors then attempted to compensate for the gantry sag by applying a gantry angle‐specific correction to the MLC leaf positions. The gantry sag and its compensation were independently verified using film measurements.Results:: Gantry sag was reproducible over a six‐month measurement period. The maximum gantry sag was found to vary from 0.7 to 1.0 mm, depending on the linac and the collimator angle. The radiation field center moved inferiorly (i.e., away from the gantry) when the gantry was rotated from 0° to 180°. After the MLC leaf position compensation was applied at 90° collimator angle, the maximum gantry sag was reduced to Conclusions:: The results indicate that gantry sag on a linac can be quantitatively measured using a simple phantom and an electronic portal imaging device. Reduction of gantry sag is feasible by applying a gantry angle‐specific correction to MLC leaf positions at 90° collimator angle.
- 28 March 2012
- Published by Wiley in Medical Physics
- Vol. 39 (4) , 2156-2162
Quantifying the gantry sag on linear accelerators and introducing an MLC‐based compensation strategy
Purpose:: Gantry sag is one of the well‐known sources of mechanical imperfections that compromise the spatial accuracy of radiation dose delivery. The objectives of this study were to quantify the gantry sag on multiple linear accelerators (linacs), to investigate a multileaf collimator (MLC)‐based strategy to compensate for gantry sag, and to verify the gantry sag and its compensation with film measurements.Methods:: The authors used the Winston–Lutz method to measure gantry sag on three Varian linacs. A ball bearing phantom was imaged with megavolt radiation fields at 10° gantry angle intervals. The images recorded with an electronic portal imaging device were analyzed to derive the radiation isocenter and the gantry sag, that is, the superior–inferior wobble of the radiation field center, as a function of the gantry angle. The authors then attempted to compensate for the gantry sag by applying a gantry angle‐specific correction to the MLC leaf positions. The gantry sag and its compensation were independently verified using film measurements.Results:: Gantry sag was reproducible over a six‐month measurement period. The maximum gantry sag was found to vary from 0.7 to 1.0 mm, depending on the linac and the collimator angle. The radiation field center moved inferiorly (i.e., away from the gantry) when the gantry was rotated from 0° to 180°. After the MLC leaf position compensation was applied at 90° collimator angle, the maximum gantry sag was reduced to Conclusions:: The results indicate that gantry sag on a linac can be quantitatively measured using a simple phantom and an electronic portal imaging device. Reduction of gantry sag is feasible by applying a gantry angle‐specific correction to MLC leaf positions at 90° collimator angle.
- 22 July 2011
- Published by Wiley in Medical Physics
- Vol. 38 (8) , 4575-4578
Measuring the wobble of radiation field centers during gantry rotation and collimator movement on a linear accelerator
Purpose: The isocenter accuracy of a linear accelerator is often assessed with star‐shot films. This approach is limited in its ability to quantify three dimensional wobble of radiation field centers (RFCs). The authors report a Winston–Lutz based method to measure the 3D wobble of RFCs during gantry rotation, collimator rotation, and collimator field size change.Methods: A stationary ball‐bearing phantom was imaged using multileaf collimator‐shaped radiation fields at various gantry angles, collimator angles, and field sizes. The center of the ball‐bearing served as a reference point, to which all RFCs were localized using a computer algorithm with subpixel accuracy. Then, the gantry rotation isocenter and the collimator rotation axis were derived from the coordinates of these RFCs. Finally, the deviation or wobble of the individual RFC from the derived isocenter or rotation axis was quantified.Results: The results showed that the RFCs were stable as the field size of the multileaf collimator was varied. The wobble of RFCs depended on the gantry angle and the collimator angle and was reproducible, indicating that the mechanical imperfections of the linac were mostly systematic and quantifiable. It was found that the 3D wobble of RFCs during gantry rotation was reduced after compensating for a constant misalignment of the multileaf collimator.Conclusions: The 3D wobble of RFCs can be measured with submillimeter precision using the proposed method. This method provides a useful tool for checking and adjusting the radiation isocenter tightness of a linac.
- 22 July 2011
- Published by Wiley in Medical Physics
- Vol. 38 (8) , 4575-4578
Measuring the wobble of radiation field centers during gantry rotation and collimator movement on a linear accelerator
Purpose: The isocenter accuracy of a linear accelerator is often assessed with star‐shot films. This approach is limited in its ability to quantify three dimensional wobble of radiation field centers (RFCs). The authors report a Winston–Lutz based method to measure the 3D wobble of RFCs during gantry rotation, collimator rotation, and collimator field size change.Methods: A stationary ball‐bearing phantom was imaged using multileaf collimator‐shaped radiation fields at various gantry angles, collimator angles, and field sizes. The center of the ball‐bearing served as a reference point, to which all RFCs were localized using a computer algorithm with subpixel accuracy. Then, the gantry rotation isocenter and the collimator rotation axis were derived from the coordinates of these RFCs. Finally, the deviation or wobble of the individual RFC from the derived isocenter or rotation axis was quantified.Results: The results showed that the RFCs were stable as the field size of the multileaf collimator was varied. The wobble of RFCs depended on the gantry angle and the collimator angle and was reproducible, indicating that the mechanical imperfections of the linac were mostly systematic and quantifiable. It was found that the 3D wobble of RFCs during gantry rotation was reduced after compensating for a constant misalignment of the multileaf collimator.Conclusions: The 3D wobble of RFCs can be measured with submillimeter precision using the proposed method. This method provides a useful tool for checking and adjusting the radiation isocenter tightness of a linac.
- Open Access
- 2 July 2010
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 11 (4) , 15-26
A quality assurance procedure to evaluate cone‐beam CT image center congruence with the radiation isocenter of a linear accelerator
A quality assurance (QA) procedure was developed to evaluate the congruence between the cone‐beam computed tomography (CBCT) image center and the radiation isocenter on a Varian Trilogy linac. In contrast to the published QA procedures, this method did not require a ball bearing (BB) phantom to be placed exactly at the radiation isocenter through precalibrated room lasers or light field crosshairs. The only requirement was that the BB phantom be in a stationary position near the radiation isocenter during the image acquisition process. The radiation isocenter was determined with respect to the center of the BB using a Winston‐Lutz test. The CBCT image center was found to have excellent short‐term positional reproducibility (i.e., less than 0.1 mm of wobble in each of the x (lateral), y (vertical), and z (longitudinal) directions) in 10 consecutive acquisitions. Measured over a seven‐month period, the CBCT image center deviated from the radiation isocenter by , and . The z displacement of the 3D CBCT image center was highly correlated with that of the 2D kV portal image center. The correlation coefficients in the x and y directions were poor ( and ‐0.35, respectively). Systematic discrepancies were found between the CBCT image center and the 2D MV, kV portal image centers. For the linear accelerator studied, we detected a 0.8 mm discrepancy between the CBCT image center and the MV EPID image center in the anterior‐posterior direction. This discrepancy was demonstrated in a clinical case study where the patient was positioned with CBCT followed by MV portal verification. The results from the new QA procedure are useful for guiding high‐precision patient positioning in stereotactic body radiation therapy.PACS number: 87.55.Qr
- 2 July 2010
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 11 (4) , 15-26
Open AccessA quality assurance procedure to evaluate cone‐beam CT image center congruence with the radiation isocenter of a linear accelerator
A quality assurance (QA) procedure was developed to evaluate the congruence between the cone‐beam computed tomography (CBCT) image center and the radiation isocenter on a Varian Trilogy linac. In contrast to the published QA procedures, this method did not require a ball bearing (BB) phantom to be placed exactly at the radiation isocenter through precalibrated room lasers or light field crosshairs. The only requirement was that the BB phantom be in a stationary position near the radiation isocenter during the image acquisition process. The radiation isocenter was determined with respect to the center of the BB using a Winston‐Lutz test. The CBCT image center was found to have excellent short‐term positional reproducibility (i.e., less than 0.1 mm of wobble in each of the x (lateral), y (vertical), and z (longitudinal) directions) in 10 consecutive acquisitions. Measured over a seven‐month period, the CBCT image center deviated from the radiation isocenter by , and . The z displacement of the 3D CBCT image center was highly correlated with that of the 2D kV portal image center. The correlation coefficients in the x and y directions were poor ( and ‐0.35, respectively). Systematic discrepancies were found between the CBCT image center and the 2D MV, kV portal image centers. For the linear accelerator studied, we detected a 0.8 mm discrepancy between the CBCT image center and the MV EPID image center in the anterior‐posterior direction. This discrepancy was demonstrated in a clinical case study where the patient was positioned with CBCT followed by MV portal verification. The results from the new QA procedure are useful for guiding high‐precision patient positioning in stereotactic body radiation therapy.PACS number: 87.55.Qr
- 28 April 2010
- Published by Wiley in Medical Physics
- Vol. 37 (5) , 2256-2263
A simple method to quantify the coincidence between portal image graticules and radiation field centers or radiation isocenter
Purpose: The aim of this study was to develop a computerized method to quantify the coincidence between portal image graticules and radiation field centers or radiation isocenter. Three types of graticules were included in this study: Megavoltage (MV) mechanical graticule, MV electronic portal imaging device digital graticule, and kilovoltage (kV) on‐board imaging digital graticule.Methods: A metal ball bearing (BB) was imaged with MV and kV x‐ray beams in a procedure similar to a Winston–Lutz test. The radiation fields, graticules, and BB were localized in eight portal images using Hough transform‐based computer algorithms. The center of the BB served as a static reference point in the 3D space so that the distances between the graticule centers and the radiation field centers were calculated. The radiation isocenter was determined from the radiation field centers at different gantry angles.Results: Misalignments of MV and kV portal imaging graticules varied with the gantry or x‐ray source angle as a result of mechanical imperfections of the linear accelerator and its imaging system. While the three graticules in this study were aligned to the radiation field centers and the radiation isocenter within 2.0 mm, misalignments of 1.5–2.0 mm were found at certain gantry angles. These misalignments were highly reproducible with the gantry rotation.Conclusions: A simple method was developed to quantify the alignments of portal image graticules directly against the radiation field centers or the radiation isocenter. The advantage of this method is that it does not require the BB to be placed exactly at the radiation isocenter through a precalibrated surrogating device such as room lasers or light field crosshairs. The present method is useful for radiation therapy modalities that require high‐precision portal imaging such as image‐guided stereotactic radiotherapy.
- 28 April 2010
- Published by Wiley in Medical Physics
- Vol. 37 (5) , 2256-2263
A simple method to quantify the coincidence between portal image graticules and radiation field centers or radiation isocenter
Purpose: The aim of this study was to develop a computerized method to quantify the coincidence between portal image graticules and radiation field centers or radiation isocenter. Three types of graticules were included in this study: Megavoltage (MV) mechanical graticule, MV electronic portal imaging device digital graticule, and kilovoltage (kV) on‐board imaging digital graticule.Methods: A metal ball bearing (BB) was imaged with MV and kV x‐ray beams in a procedure similar to a Winston–Lutz test. The radiation fields, graticules, and BB were localized in eight portal images using Hough transform‐based computer algorithms. The center of the BB served as a static reference point in the 3D space so that the distances between the graticule centers and the radiation field centers were calculated. The radiation isocenter was determined from the radiation field centers at different gantry angles.Results: Misalignments of MV and kV portal imaging graticules varied with the gantry or x‐ray source angle as a result of mechanical imperfections of the linear accelerator and its imaging system. While the three graticules in this study were aligned to the radiation field centers and the radiation isocenter within 2.0 mm, misalignments of 1.5–2.0 mm were found at certain gantry angles. These misalignments were highly reproducible with the gantry rotation.Conclusions: A simple method was developed to quantify the alignments of portal image graticules directly against the radiation field centers or the radiation isocenter. The advantage of this method is that it does not require the BB to be placed exactly at the radiation isocenter through a precalibrated surrogating device such as room lasers or light field crosshairs. The present method is useful for radiation therapy modalities that require high‐precision portal imaging such as image‐guided stereotactic radiotherapy.
- 6 January 2009
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (3) , 555-567
A robust Hough transform algorithm for determining the radiation centers of circular and rectangular fields with subpixel accuracy
Uncertainty in localizing the radiation field center is among the major components that contribute to the overall positional error and thus must be minimized. In this study, we developed a Hough transform (HT)-based computer algorithm to localize the radiation center of a circular or rectangular field with subpixel accuracy. We found that the HT method detected the centers of the test circular fields with an absolute error of 0.037 +/- 0.019 pixels. On a typical electronic portal imager with 0.5 mm image resolution, this mean detection error was translated to 0.02 mm, which was much finer than the image resolution. It is worth noting that the subpixel accuracy described here does not include experimental uncertainties such as linac mechanical instability or room laser inaccuracy. The HT method was more accurate and more robust to image noise and artifacts than the traditional center-of-mass method. Application of the HT method in Winston-Lutz tests was demonstrated to measure the ball-radiation center alignment with subpixel accuracy. Finally, the method was applied to quantitative evaluation of the radiation center wobble during collimator rotation.
- 6 January 2009
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (3) , 555-567
A robust Hough transform algorithm for determining the radiation centers of circular and rectangular fields with subpixel accuracy
Uncertainty in localizing the radiation field center is among the major components that contribute to the overall positional error and thus must be minimized. In this study, we developed a Hough transform (HT)-based computer algorithm to localize the radiation center of a circular or rectangular field with subpixel accuracy. We found that the HT method detected the centers of the test circular fields with an absolute error of 0.037 +/- 0.019 pixels. On a typical electronic portal imager with 0.5 mm image resolution, this mean detection error was translated to 0.02 mm, which was much finer than the image resolution. It is worth noting that the subpixel accuracy described here does not include experimental uncertainties such as linac mechanical instability or room laser inaccuracy. The HT method was more accurate and more robust to image noise and artifacts than the traditional center-of-mass method. Application of the HT method in Winston-Lutz tests was demonstrated to measure the ball-radiation center alignment with subpixel accuracy. Finally, the method was applied to quantitative evaluation of the radiation center wobble during collimator rotation.