MGMichael P. Gorga

Michael P. Gorga

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Michael P. Gorga has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Reliability of Categorical Loudness Scaling and Its Relation to Threshold

    by Sarah C. Al-Salim, Judy G. Kopun, Stephen T. Neely, Walt Jesteadt, Bettina Stiegemann, Michael P. Gorga

    Objective: To further examine the reliability of categorical loudness scaling (CLS) for individual loudness categories and for the slope of the CLS functions. And, to evaluate the relationship between CLS and audiometric threshold. Design: CLS functions were obtained in 74 subjects, 58 with hearing loss and 16 with normal hearing. CLS functions were measured at three frequencies (1, 2, and 4 kHz) in two separate sessions separated by as little as 1 wk and as much as 6 mo. Reliability of mean and median levels within each loudness category was assessed using SDs and correlation coefficients. Lines were fit to the CLS functions, and slopes of the lines were used to assess reliability and the relation between CLS and audiometric threshold. Results: Similar reliability for CLS measurements was observed in both normal-hearing and hearing-impaired subjects at all frequencies. Across both groups of subjects, correlations describing the reliability of mean stimulus level within category exceeded 0.92 at all frequencies. In addition, SDs of the mean stimulus-level difference between visits ranged from 6.6 to 7.8 dB, depending on frequency. The correlation between the slope of a straight line fitted to the entire CLS function and audiometric threshold collapsed across frequencies was 0.72. Two line segments were then fit to the CLS function: one segment was fit to the soft portion of the CLS function (categorical units ≤20) and the other segment to the loud portion (categorical unit >20). Slopes of the line fit to the entire CLS function and of the line fit to the soft portion of the CLS function were both reliable across sessions. The slope of the line fit to the soft portion increased as audiometric threshold increased, with the correlations greater than 0.86 at all frequencies. No relationship was observed between slope of the line fit to the loud portion of the CLS function and audiometric threshold. Iso-loudness contours were constructed from the CLS data and used to determine the gain that would be needed to produce “normal” loudness percepts for hearing-impaired individuals. Conclusions: Within-subject CLS measurements were reliable across sessions both for individual loudness categories and for slope of the CLS functions. In addition, the slope of the low-level portion of the CLS function varied in a predictable manner with audiometric threshold, with slope increasing as audiometric threshold increased. Finally, gain as a function of input level needed to provide loudness percepts for individuals with hearing loss equal to the loudness percepts of normal-hearing individuals can be estimated from audiometric threshold. This finding supports the assumption that audiometric threshold and response growth (loudness) are both determined by the same underlying cochlear mechanisms.


  • Wideband acoustic-reflex test in a test battery to predict middle-ear dysfunction

    by Douglas H. Keefe, Denis Fitzpatrick, Yi-Wen Liu, Chris A. Sanford, Michael P. Gorga


  • Low-frequency and high-frequency distortion product otoacoustic emission suppression in humans

    by Michael P. Gorga, Stephen T. Neely, Darcia M. Dierking, Judy Kopun, Kristin Jolkowski, Kristin Groenenboom, Hongyang Tan, Bettina Stiegemann

    Distortion product otoacoustic emission suppression (quantified as decrements) was measured for f 2 = 500 and 4000 Hz , for a range of primary levels ( L 2 ) , suppressor frequencies ( f 3 ) , and suppressor levels ( L 3 ) in 19 normal-hearing subjects. Slopes of decrement-versus- L 3 functions were similar at both f 2 frequencies, and decreased as f 3 increased. Suppression tuning curves, constructed from decrement functions, were used to estimate (1) suppression for on- and low-frequency suppressors, (2) tip-to-tail differences, (3) Q ERB , and (4) best frequency. Compression, estimated from the slope of functions relating suppression “threshold” to L 2 for off-frequency suppressors, was similar for 500 and 4000 Hz . Tip-to-tail differences, Q ERB , and best frequency decreased as L 2 increased for both frequencies. However, tip-to-tail difference (an estimate of cochlear-amplifier gain) was 20 dB greater at 4000 Hz , compared to 500 Hz . Q ERB decreased to a greater extent with L 2 when f 2 = 4000 Hz , but, on an octave scale, best frequency shifted more with level when f 2 = 500 Hz . These data indicate that, at both frequencies, cochlear processing is nonlinear. Response growth and compression are similar at the two frequencies, but gain is greater at 4000 Hz and spread of excitation is greater at 500 Hz .


  • Low-frequency and high-frequency cochlear nonlinearity in humans

    by Michael P. Gorga, Stephen T. Neely, Darcia M. Dierking, Judy Kopun, Kristin Jolkowski, Kristin Groenenboom, Hongyang Tan, Bettina Stiegemann

    Low- and high-frequency cochlear nonlinearity was studied by measuring distortion product otoacoustic emission input/output (DPOAE I/O) functions at 0.5 and 4kHz in 103 normal-hearing subjects. Behavioral thresholds at both f2 ’s were used to set L2 in dB SL for each subject. Primary levels were optimized by determining the L1 resulting in the largest Ldp for each L2 for each subject and both f2 ’s. DPOAE I/O functions were measured using L2 inputs from −10dB SL (0.5kHz) or −20dB SL (4kHz) to 65dB SL (both frequencies). Mean DPOAE I/O functions, averaged across subjects, differed between the two frequencies, even when threshold was taken into account. The slopes of the I/O functions were similar at 0.5 and 4kHz for high-level inputs, with maximum compression ratios of about 4:1. At both frequencies, the maximum slope near DPOAE threshold was approximately 1, which occurred at lower levels at 4kHz , compared to 0.5kHz . These results suggest that there is a wider dynamic range and perhaps greater cochlear-amplifier gain at 4kHz , compared to 0.5kHz . Caution is indicated, however, because of uncertainties in the interpretation of slope and because the confounding influence of differences in noise level could not be completely controlled.


  • Using a Combination of Click- and Tone Burst–Evoked Auditory Brain Stem Response Measurements to Estimate Pure-Tone Thresholds

    by Michael P. Gorga, Tiffany A. Johnson, Jan R. Kaminski, Kathryn L. Beauchaine, Cassie A. Garner, Stephen T. Neely

    Design: A retrospective medical record review of evoked potential and audiometric data were used to determine the accuracy with which click-evoked and tone burst–evoked auditory brain stem response (ABR) thresholds predict pure-tone audiometric thresholds. Methods: The medical records were reviewed of a consecutive group of patients who were referred for ABR testing for audiometric purposes over the past 4 yrs. ABR thresholds were measured for clicks and for several tone bursts, including a single-cycle, Blackman-windowed, 250-Hz tone burst, which has a broad spectrum with little energy above 600 Hz. Typically, the ABR data were collected because the patients were unable to provide reliable estimates of hearing sensitivity, based on behavioral test techniques, due to developmental level. Data were included only if subsequently obtained behavioral audiometric data were available to which the ABR data could be compared. Almost invariably, the behavioral data were collected after the ABR results were obtained. Because of this, data were included on only those ears for which middle ear tests (tympanometry, otoscopic examination, pure-tone air- and bone-conduction thresholds) indicated that middle ear status was similar at the times of both tests. With these inclusion criteria, data were available on 140 ears of 77 subjects. Results: Correlation was 0.94 between click-evoked ABR thresholds and the average pure-tone threshold at 2 and 4 kHz. Correlations exceeded 0.92 between ABR thresholds for the 250-Hz tone burst and low-frequency behavioral thresholds (250 Hz, 500 Hz, and the average pure-tone thresholds at 250 and 500 Hz). Similar or higher correlations were observed when ABR thresholds at other frequencies were compared with the pure-tone thresholds at corresponding frequencies. Differences between ABR and behavioral threshold depended on behavioral threshold, with ABR thresholds overestimating behavioral threshold in cases of normal hearing and underestimating behavioral threshold in cases of hearing loss. Conclusions: These results suggest that ABR thresholds can be used to predict pure-tone behavioral thresholds for a wide range of frequencies. Although controversial, the data reviewed in this paper suggest that click-evoked ABR thresholds result in reasonable predictions of the average behavioral thresholds at 2 and 4 kHz. However, there were cases for which click-evoked ABR thresholds underestimated hearing loss at these frequencies. There are several other reasons why click-evoked ABR measurements were made, including that they (1) generally result in well-formed responses, (2) assist in determining whether auditory neuropathy exists, and (3) can be obtained in a relatively brief amount of time. Low-frequency thresholds were predicted well by ABR thresholds to a single-cycle, 250-Hz tone burst. In combination, click-evoked and low-frequency tone burst–evoked ABR threshold measurements might be used to quickly provide important clinical information for both ends of the audiogram. These measurements could be supplemented by ABR threshold measurements at other frequencies, if time permits. However, it may be possible to plan initial intervention strategies based on data for these two stimuli.


  • A Validation and Potential Clinical Application of Multivariate Analyses of Distortion-Product Otoacoustic Emission Data

    by Michael P. Gorga, Darcia M. Dierking, Tiffany A. Johnson, Kathryn L. Beauchaine, Cassie A. Garner, Stephen T. Neely

    Objective: To test the generalizability of multivariate analyses of distortion-product otoacoustic emission (DPOAE) data. Previously published multivariate solutions were applied to a new set of data to determine if test-performance improvements, evident in previous reports, are retained. An additional objective was to provide an alternative approach for making multivariate dichotomous decisions of hearing status in the clinic, based on DPOAE measurements. Design: DPOAE level and noise were obtained in 345 ears of 187 subjects. Approximately one third of the subjects had normal hearing, whereas the remainder had hearing loss, ranging from 25 to more than 120 dB HL. DPOAE data were collected at each of nine frequencies. After data collection, clinical decision theory, in combination with univariate (DPOAE level and signal-to-noise ratio [SNR]) and multivariate (logistic regression) analyses, was used to construct relative operating characteristic (ROC) curves and to generate ROC curve areas. In addition, test performance was assessed by fixing the false-alarm rate and comparing different approaches to analyses in terms of their failure rates as a function of magnitude of hearing loss. The DPOAE test results were compared with either single-frequency or multifrequency gold standards. The multivariate solutions were taken from previously published work (Dorn et al., 1999; Gorga, et al., 1999). Results: DPOAE level and SNR resulted in roughly equivalent test performance (ROC curve areas and failure rates among ears with hearing loss), although DPOAE level performed better for frequencies above 1 kHz, and SNR performed better for frequencies at 0.75 and 1 kHz. Multivariate analyses resulted in better test performance for nearly all conditions, compared with the univariate approaches that used either DPOAE level or SNR. The improvements in test performance were greatest for the frequencies at which the univariate analyses performed poorest (0.75 kHz, 1 kHz, and 8 kHz). Less difference was observed between univariate and multivariate approaches when multifrequency gold standards were used; however, even for the multifrequency cases, multivariate analyses generally resulted in better performance. An approach that might facilitate the interpretation of multifrequency DPOAE measurements in the clinic is described. Conclusions: Previously described multivariate analyses were robust in that they improved test performance when applied to an entirely new set of DPOAE data. This, in turn, suggests that the previously described multivariate solutions may have clinical utility in that they are expected to improve test performance at no additional cost in terms of data-acquisition or data-analysis time. In addition to demonstrating that these solutions generalized to new data, an alternative approach to interpreting multifrequency DPOAE measurements is provided that includes the advantages of using multivariate analyses. This new metric may be useful when DPOAEs are used for screening purposes.


  • Determining the Upper Limits of Stimulation for Auditory Steady-State Response Measurements

    by Michael P. Gorga, Stephen T. Neely, Brenda M. Hoover, Darcia M. Dierking, Kathryn L. Beauchaine, Carol Manning

    Objective: To determine the maximum stimulus levels at which a measured auditory steady-state response (ASSR) can be assumed to be a reliable measure of auditory thresholds. Design: ASSR thresholds were measured at octave frequencies from 500 to 4000 Hz in 10 subjects with profound hearing loss. These subjects provided no behavioral responses to sound at the limits of pure-tone audiometers and at the limits of the stimulus levels produced by the ASSR device. Subjects were divided into two groups of five, with repeated measures obtained within the same session in one group and repeated measures obtained in a separate session on a different day in the other group. Results: ASSR thresholds were observed in all 10 subjects at each of four frequencies and in both trials. On average, these ASSR thresholds were observed at 100 dB HL (SD = 5 dB). Because these responses were at least 18 to 22 dB below the limits of the equipment where all subjects had no behavioral responses, it is reasonable to conclude that the ASSRs were not generated by the auditory system. Conclusions: An artifact or distortion may be present in the recording of ASSRs at high levels. These data bring into question the view that there is a wider dynamic range for ASSR measurements compared with auditory brain stem response measurements, at least with current implementation.


  • Distortion product otoacoustic emission suppression tuning curves in normal-hearing and hearing-impaired human ears

    by Michael P. Gorga, Stephen T. Neely, Darcia M. Dierking, Patricia A. Dorn, Brenda M. Hoover, Denis F. Fitzpatrick

    Distortion product otoacoustic emission (DPOAE) suppression measurements were made in 20 subjects with normal hearing and 21 subjects with mild-to-moderate hearing loss. The probe consisted of two primary tones (f2,f1), with f2 held constant at 4 kHz and f2/f1=1.22. Primary levels (L1,L2) were set according to the equation L1=0.4L2+39 dB [Kummer et al., J. Acoust. Soc. Am. 103, 3431–3444 (1998)], with L2 ranging from 20 to 70 dB SPL (normal-hearing subjects) and 50–70 dB SPL (subjects with hearing loss). Responses elicited by the probe were suppressed by a third tone (f3), varying in frequency from 1 octave below to 12 octave above f2. Suppressor level (L3) varied from 5 to 85 dB SPL. Responses in the presence of the suppressor were subtracted from the unsuppressed condition in order to convert the data into decrements (amount of suppression). The slopes of the decrement versus L3 functions were less steep for lower frequency suppressors and more steep for higher frequency suppressors in impaired ears. Suppression tuning curves, constructed by selecting the L3 that resulted in 3 dB of suppression as a function of f3, resulted in tuning curves that were similar in appearance for normal and impaired ears. Although variable, Q10 and QERB were slightly larger in impaired ears regardless of whether the comparisons were made at equivalent SPL or equivalent sensation levels (SL). Larger tip-to-tail differences were observed in ears with normal hearing when compared at either the same SPL or the same SL, with a much larger effect at similar SL. These results are consistent with the view that subjects with normal hearing and mild-to-moderate hearing loss have similar tuning around a frequency for which the hearing loss exists, but reduced cochlear-amplifier gain.


  • Further efforts to predict pure-tone thresholds from distortion product otoacoustic emission input/output functions

    by Michael P. Gorga, Stephen T. Neely, Patricia A. Dorn, Brenda M. Hoover

    Recently, Boege and Janssen [J. Acoust. Soc. Am. 111, 1810–1818 (2002)] fit linear equations to distortion product otoacoustic emission (DPOAE) input/output (I/O) functions after the DPOAE level (in dB SPL) was converted into pressure (in μPa). Significant correlations were observed between these DPOAE thresholds and audiometric thresholds. The present study extends their work by (1) evaluating the effect of frequency, (2) determining the behavioral thresholds in those conditions that did not meet inclusion criteria, and (3) including a wider range of stimulus levels. DPOAE I/O functions were measured in as many as 278 ears of subjects with normal and impaired hearing. Nine f2 frequencies (500 to 8000 Hz in 12 -octave steps) were used, L2 ranged from 10 to 85 dB SPL (5-dB steps), and L1 was set according to the equation L1=0.4L2+39 dB [Kummer et al., J. Acoust. Soc. Am. 103, 3431–3444 (1998)] for L2 levels up to 65 dB SPL, beyond which L1=L2. For the same conditions as those used by Boege and Janssen, we observed a frequency effect such that correlations were higher for mid-frequency threshold comparisons. In addition, a larger proportion of conditions not meeting inclusion criteria at mid and high frequencies had hearing losses exceeding 30 dB HL, compared to lower frequencies. These results suggest that DPOAE I/O functions can be used to predict audiometric thresholds with greater accuracy at mid and high frequencies, but only when certain inclusion criteria are met. When the SNR inclusion criterion is not met, the expected amount of hearing loss increases. Increasing the range of input levels from 20–65 dB SPL to 10–85 dB SPL increased the number of functions meeting inclusion criteria and increased the overall correlation between DPOAE and behavioral thresholds.


  • Cost‐effectiveness and test‐performance factors in relation to universal newborn hearing screening

    by Michael P. Gorga, Stephen T. Neely

    The first portion of this paper reviews current understanding of the cost of universal newborn hearing screening (UNHS), including capital and operating expenses, as well as the costs for follow‐up testing on infants who do not pass the hearing screening test in the perinatal period. Capital expenses include the cost of equipment. Operating expenses include the costs for disposables and personnel. Follow‐up costs relate to the diagnostic testing that must be performed in order to determine hearing status in those infants who do not pass the newborn hearing screening test. This section is followed by a more theoretical approach, in which test performance, prevalence, program costs, and “costs of hearing loss” are combined in a model that includes all costs of hearing loss, including screening, follow‐up testing, and costs (benefits) associated with identifying hearing loss early in life. While some of the model's cost/benefit assumptions may be incorrect, the general approach of taking into account both costs and benefits provides a framework for evaluating the utility of UNHS in a more global manner. Model assumptions (costs, benefits, prevalence, sensitivity, specificity) can be changed to values deemed more appropriate, but the general approach is still informative. With the present assumptions, it is shown that initially, the costs of UNHS exceed its benefits. However, after only four years of operation, UNHS programs will result in a net savings to society. These savings increase rapidly, reaching a maximum annual benefit of seven billion dollars 75 years after initiation of the program, which is also the societal benefit for all years thereafter. MRDD Research Reviews 2003;9:103–108.