SVSusan E. Voss

Susan E. Voss

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Susan E. Voss has a total of 14 co-authors. Here are the top co-authors by number of shared publications:

  • John J. Rosowski

    Eaton-Peabody Laboratory of Auditory Physiology , Massachusetts Eye and Ear Infirmary, 243 Charles Street, Boston, Massachusetts 02114, Department of Otology and Laryngology Boston, Massachusetts 02115 and , Harvard-M.I.T. Division of Health Sciences and Technology, Cambridge, Massachusetts 02139

    3 shared publications
  • Saumil N. Merchant

    Eaton-Peabody Laboratory of Auditory Physiology , Massachusetts Eye and Ear Infirmary, 243 Charles Street, Boston, Massachusetts 02114, Department of Otology and Laryngology Boston, Massachusetts 02115 and , Harvard-M.I.T. Division of Health Sciences and Technology, Cambridge, Massachusetts 02139

    3 shared publications
  • William T. Peake

    Eaton-Peabody Laboratory of Auditory Physiology , Massachusetts Eye and Ear Infirmary, 243 Charles Street, Boston, Massachusetts 02114, Research Laboratory of Electronics Cambridge, Massachusetts 02139, and , Harvard-M.I.T. Division of Health Sciences and Technology, Cambridge, Massachusetts 02139

    3 shared publications
  • Barbara S. Herrmann

    Picker Engineering Program (S.E.V.), Smith College, Northampton, Massachusetts, and Department of Otology and Laryngology (B.S.H), Harvard Medical School, Boston, Massachusetts

    1 shared publication
  • Christopher A. Shera

    Eaton-Peabody Laboratory of Auditory Physiology, Massachusetts Eye and Ear Infirmary, 243 Charles Street Boston, Massachusetts 02114

    1 shared publication
  • John J. Rosowski

    Department of Otolaryngology and Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, 243 Charles Street, Boston, MA 02114, USA

    1 shared publication

Latest Publications

  • Sources of Variability in Reflectance Measurements on Normal Cadaver Ears

    by Susan E. Voss, Nicholas J. Horton, Rebecca R. Woodbury, Kathryn N. Sheffield

    The development of acoustic reflectance measurements may lead to noninvasive tests that provide information currently unavailable from standard audiometric testing. One factor limiting the development of these tests is that normal-hearing human ears show substantial intersubject variations. This work examines intersubject variability that results from measurement location within the ear canal, estimates of ear-canal area, and variations in middle-ear cavity volume. Energy reflectance (ER) measurements were made on nine human-cadaver ears to study three variables. (1) ER was measured at multiple ear-canal locations. (2) The ear-canal area at each measurement location was measured and the ER was calculated with the measured area, a constant area, and an acoustically estimated area. (3) The ER was measured with the middle-ear cavity in three conditions: (1) normal, (2) the mastoid widely opened (large air space), and (3) the mastoid closed off at the aditus ad antrum (small air space). Measurement-location effects are generally largest at frequencies below about 2000 Hz, where in some ears reflectance magnitudes tend to decrease systematically as the measurement location moves away from the tympanic membrane but in other ears the effects seem minimal. Intrasubject variations in reflectance due to changes in either measurement location within the ear canal or differences in the estimate of the ear-canal area are smaller than variations produced by large variations in middle-ear cavity air volume or intersubject differences. At frequencies below 2000 Hz, large increases in cavity volume systematically reduce the ER, with more variable changes above 2000 Hz. ER measurements depend on all variables studied: measurement location, ear-canal cross-sectional area, and middle-ear cavity volume. Variations within an individual ear in either measurement location or ear-canal cross-sectional area result in relatively small effects on the ER, supporting the notion that diagnostic tests (1) need not control for measurement location and (2) can assume a constant ear-canal area across most subjects. Variations in cavity volume produce much larger effects in ER than measurement location or ear-canal area, possibly explaining some of the intersubject variation in ER reported among normal ears.


  • Non-ossicular signal transmission in human middle ears: Experimental assessment of the “acoustic route” with perforated tympanic membranes

    by Susan E. Voss, John J. Rosowski, Saumil N. Merchant, William T. Peake

    Direct acoustic stimulation of the cochlea by the sound-pressure difference between the oval and round windows (called the “acoustic route”) has been thought to contribute to hearing in some pathological conditions, along with the normally dominant “ossicular route.” To determine the efficacy of this acoustic route and its constituent mechanisms in human ears, sound pressures were measured at three locations in cadaveric temporal bones [with intact and perforated tympanic membranes (TMs)]: (1) in the external ear canal lateral to the TM, PTM ; (2) in the tympanic cavity lateral to the oval window, POW ; and (3) near the round window, PRW . Sound transmission via the acoustic route is described by two concatenated processes: (1) coupling of sound pressure from ear canal to middle-ear cavity, HPCAV≡PCAV∕PTM , where PCAV represents the middle-ear cavity pressure, and (2) sound-pressure difference between the windows, HWPD≡(POW−PRW)∕PCAV . Results show that: HPCAV depends on perforation size but not perforation location; HWPD depends on neither perforation size nor location. The results (1) provide a description of the window pressures based on measurements, (2) refute the common otological view that TM perforation location affects the “relative phase of the pressures at the oval and round windows,” and (3) show with an intact ossicular chain that acoustic-route transmission is substantially below ossicular-route transmission except for low frequencies with large perforations. Thus, hearing loss from TM perforations results primarily from reduction in sound coupling via the ossicular route. Some features of the frequency dependence of HPCAV and HWPD can be interpreted in terms of a structure-based lumped-element acoustic model of the perforation and middle-ear cavities.


  • How Does the Sound Pressure Generated by Circumaural, Supra-aural, and Insert Earphones Differ for Adult and Infant Ears?

    by Susan E. Voss, Barbara S. Herrmann

    Objective: To determine how the ear canal sound pressure levels generated by circumaural, supra-aural, and insert earphones differ when coupled to the normal adult and infant ear. Design: The ratio between the sound pressure generated in an adult ear and an infant ear was calculated for three types of earphones: a circumaural earphone (Natus Medical, ALGO with Flexicoupler™), a supra-aural earphone (Telephonics, TDH-49 with MXAR cushion), and an insert earphone placed in the ear canal (Etymo↕tic Research, ER-3A). The calculations are based on (1) previously published measurements of ear canal impedances in adult and infant (ages 1, 3, 6, 12, and 24 months) ears (Keefe et al., 1993, Acoustic Society of America, 94:2617–2638), (2) measurements of the Thévenin equivalent for each earphone configuration, and (3) acoustic models of the ear canal and external ear. Results: Sound-pressure levels depend on the ear canal location at which they are measured. For pressures at the earphone: (1) Circumaural and supra-aural earphones produce changes between infant and adult ears that are less than 3 dB at all frequencies, and (2) insert earphones produce infant pressures that are up to 15 dB greater than adult pressures. For pressures at the tympanic membrane: (1) Circumaural and supra-aural earphones produce infant pressures that are within 2 dB of adult ears at frequencies below 2000 Hz and that are 5 to 7 dB smaller in infant ears than adult ears above 2000 Hz, and (2) insert earphones produce pressures that are 5 to 8 dB larger in infant ears than adult ears across all audiometric frequencies. Conclusions: Sound pressures generated by all earphone types (circumaural, supra-aural, and insert) depend on the dimensions of the ear canal and on the impedance of the ear at the tympanic membrane (e.g., infant versus adult). Specific conclusions depend on the location along the ear canal at which the changes between adult and infant ears are referenced (i.e., the earphone output location or the tympanic membrane). With circumaural and supra-aural earphones, the relatively large volume of air within the cuff of the earphone dominates the acoustic load that these earphones must drive, and differences in sound pressure generated in infant and adult ears are generally smaller than those with the insert earphone in which the changes in ear canal dimensions and impedance at the tympanic membrane have a bigger effect on the load the earphone must drive.


  • Simultaneous measurement of middle-ear input impedance and forward/reverse transmission in cat

    by Susan E. Voss, Christopher A. Shera

    Reported here is a technique for measuring forward and reverse middle-ear transmission that exploits distortion-product otoacoustic emissions (DPOAEs) to drive the middle ear “in reverse” without opening the inner ear. The technique allows measurement of DPOAEs, middle-ear input impedance, and forward and reverse middle-ear transfer functions in the same animal. Intermodulation distortion in the cochlea generates a DPOAE at frequency 2f1−f2 measurable in both ear-canal pressure and the velocity of the stapes. The forward transfer function is computed from stapes velocities and corresponding ear-canal pressures measured at the two primary frequencies; the reverse transfer function is computed from velocity and pressure measurements at the DPOAE frequency. Middle-ear input impedance is computed from ear-canal pressure measurements and the measured Thévenin equivalent of the sound-delivery system. The technique was applied to measure middle-ear characteristics in anesthetized cats with widely opened middle-ear cavities (0.2–10 kHz). Stapes velocity was measured at the incudo-stapedial joint. Results on five animals are reported and compared with a published middle-ear model. The measured forward transfer functions and input impedances generally agree with previous measurements, and all measurements agree qualitatively with model predictions. The reverse transfer function is shown to depend on the acoustic load in the ear canal, and the measurements are used to compute the round-trip middle-ear gain and delay. Finally, the measurements are used to estimate the parameters of a two-port transfer-matrix description of the cat middle ear.


  • Middle-ear function with tympanic-membrane perforations. I. Measurements and mechanisms

    by Susan E. Voss, John J. Rosowski, Saumil N. Merchant, William T. Peake

    Sound transmission through ears with tympanic-membrane (TM) perforations is not well understood. Here, measurements on human-cadaver ears are reported that describe sound transmission through the middle ear with experimentally produced perforations, which range from 0.5 to 5.0 mm in diameter. Three response variables were measured with acoustic stimulation at the TM: stapes velocity, middle-ear cavity sound pressure, and acoustic impedance at the TM. The stapes-velocity measurements show that perforations cause frequency-dependent losses; at low frequencies losses are largest and increase as perforation size increases. Measurements of middle-ear cavity pressure coupled with the stapes-velocity measurements indicate that the dominant mechanism for loss with TM perforations is reduction in pressure difference across the TM; changes in TM-to-ossicular coupling generally contribute less than 5 dB to the loss. Measurements of middle-ear input impedance indicate that for low frequencies, the input impedance with a perforation approximates the impedance of the middle-ear cavity; as the perforation size increases, the similarity to the cavity’s impedance extends to higher frequencies. The collection of results suggests that the effects of perforations can be represented by the path for air-volume flow from the ear canal to the middle-ear cavity. The quantitative description of perforation-induced losses may help clinicians determine, in an ear with a perforation, whether poor hearing results only from the perforation or whether other pathology should be expected.


  • Middle-ear function with tympanic-membrane perforations. II. A simple model

    by Susan E. Voss, John J. Rosowski, Saumil N. Merchant, William T. Peake

    A quantitative model of the human middle ear with a tympanic-membrane (TM) perforation is developed. The model is constrained by several types of acoustic measurements made on human cadaver ears, which indicate that perforation-induced changes in transmission result primarily from changes in driving pressure across the TM and that perforation-induced change in the structure of the TM and its coupling to the ossicles contributes a substantially smaller component. The model represents the effect of a perforation on the pressure difference across the TM by inclusion of a path for sound coupling through the perforation from the ear canal to the middle-ear cavity. The model implies that hearing loss with perforations depends primarily on three quantities: the perforation diameter, sound frequency, and the volume of air in the middle-ear cavity. For the conditions that produce the largest hearing loss (low frequency and large perforation), the model yields a simple dependence of loss on frequency, perforation diameter, and middle-ear cavity volume. Predictions from this model may be useful to clinicians in determining whether, in particular cases, hearing losses are explainable by the observed perforations or if additional pathology must be involved.


    • 1 March 1997
      • Vol. 18  (2) , 139-54

    Analysis of middle ear mechanics and application to diseased and reconstructed ears.

    by S N Merchant, M E Ravicz, S Puria, S E Voss, K R Whittemore, W T Peake, J J Rosowski

    To review current concepts of the mechanical processes of the human middle ear, and to apply them to practical issues in clinical otology and tympanoplasty surgery. The wide range of conductive hearing losses associated with middle ear pathology and reconstruction cannot be adequately explained by simple models of middle ear function. Variables used to describe the system are sound pressure, volume velocity, and acoustic impedance. The relationship between specific middle ear structures and these variables is described such that inferences can be drawn regarding sound conduction in the normal, diseased, and reconstructed middle ear. Sound can be transmitted from the car canal to the cochlea via two mechanisms: the tympano-ossicular system (ossicular coupling) and direct acoustic stimulation of the oval and round windows (acoustic coupling). Acoustic coupling is negligibly small in normal ears, but can play a significant role in some diseased and reconstructed ears. In the normal ear, middle ear pressure gain (which is the result of ossicular coupling) is frequency-dependent and less than generally believed. The severity of conductive hearing loss due to middle-ear disease or after tympanoplasty surgery can be predicted by the degree to which ossicular coupling, acoustic coupling, and stapescochlear input impedance are altered. Hearing after type IV and V tympanoplasty is determined solely by acoustic coupling. The difference in magnitude between the oval- and round-window pressures is more important than the difference in phase in determining cochlear input. In tympanoplasty types I, II, and III, adequate middle-ear and round-window aeration is necessary and the tympanic membrane-ossicular configuration may be less crucial.